• Title/Summary/Keyword: Simultaneous Absorption

Search Result 124, Processing Time 0.025 seconds

Dyeing of Wool and Nylon Fabrics with Chinese Scholar Tree Extract (괴화 추출물에 의한 모와 나일론직물의 염색성)

  • 배정숙;허만우
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.2
    • /
    • pp.107-121
    • /
    • 2003
  • This study was discussed the dyeing of wool and nylon fabrics with Chinese Scholar Tree extract. The extracts of Chinese Scholar Tree was prepared in the condition of heating at $95{\pm}5C$, for 1 hour and cooling to 40C. And then the extracts of color matter treate with vacuum concentration at $60{\pm}2^{\circ}C$, 30mmHg and dried with spray dryer. The dyeing of wool and nylon fabric in this experiment was also employed the mordant dyeing method such as pre-mordant, post-mordant and simultaneous mordant method. The mordanting agents used in this study were as followings ; aluminium potassium sulfate, copper(II) acetate monohydrate, chromium potassium sulfate$.$$7H_2O$, Tin(II) chloride dihydrate, iron(II)sulfate $7H_2O$. For an evaluation of the dyeing property of the mordanting agents, the pre-mordant method, the repeat dyeing and the fastness of the light, dry cleaning, washing and rubbing measured respectively. From the results of the dye absorption, the optimum dyeing condition of the wool and nylon fabrics with Chinese Scholar Tree extract is at 80C dyeing temperature for 60 minutes. The optimum concentration of mordanting agent is Al, Cr, Sn 1%, Fe, Cu 2% solution. In general, the fastness property of the dyed wool and nylon fabrics had a comparatively high grade.

Controlled Release Properties of Ketoprofen from Methacrylate Polymer Gels (메타크릴레이트 폴리머로 제조한 겔 제제로부터 케토프로펜의 제어 방출특성)

  • Han, Kun;Park, Jeong-Sook;Kim, Nak-Seo;Chung, Youn-Bok;Cha, Cheol-Hee
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 1991
  • Hydrogels containing ketoprofen were prepared by adding NaOH or $Ca(OH)_2$ solution to Eudragit L, S and Eudispert hv at various concentration. And xerogels were prepared by drying hydrogels. On the other hand, organogels containing ketoprofen were prepared by mixing Eudragit L or S and propylene glycol. Effects of polymer content and base on drug release were investigated using KP V dissolution method. The release rate of ketoprofen from Eudragit L & S hydrogel decreased with increasing in polymer content. And the drug release rate from cal. hydroxide based gels were more decreased than that from sod. hydroxide based gels. At pH 7.2 dissolution medium, e release of ketoprofen from Edispert hv hydrogel followed apparent zero order kinetics. The release of ketoprofen from xerogel involved in simultaneous absorption of water and desorption of ketoprofen via a pH-dependant swelling controlled mechanism. The release of ketoprofen from Eudragit S organogels followed apparent zero order kinetics, providing strong evidence for a surface erosion mechanism.

  • PDF

A NUMERICAL ANALYSIS OF CZOCHRALSKI SINGLE CRYSTAL GROWTH OF SILICON WITH MISALIGNED CUSP MAGNETIC FIELDS (Misaligned된 비균일자장이 인가된 초크랄스키 실리콘 단결정성장에 대한 수치적 해석)

  • Kim, Chang Nyung
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.4 no.1
    • /
    • pp.121-131
    • /
    • 2000
  • Melt flow, heat and mass transfer of oxygen have been analyzed numerically in the process of Czochralski single crystal growth of silicon under the influence of misaligned cusp magnetic fields. Since the silicon melt in a crucible for crystal growth is of high temperature and of highly electrical-conducting, experimentation method has difficulty in analyzing the behavior of the melt flow. A set of simultaneous nonlinear equations including Navier-Stokes and Maxwell equations has been used for the modelling of the melt flow which can be regarded as a liquid metal. Together with the melt flow which forms the Marangoni convection, a flow circulation is observed near the comer close both to the crucible wall and the free surface. The melt flow tends to follow the magnetic lines instead of traversing the lines. These flow characteristics helps the flow circulation exist. Mass transfer characteristics influenced by the melt flow has been analyzed and the oxygen absorption rate to the crystal has been calculated and turned out to be rather uniform than in the case of an aligned magnetic field.

  • PDF

Reduction of Nitrotoluenes and Simultaneous Removal of Hydrogen Sulfide and Nitrotoluenes by Co3+-centered Hematoporphyrin (포피린의 촉매작용에 의한 니트로톨루엔의 환원 및 니트로톨루엔과 황화수소의 동시 제거)

  • Cho, Jeong-Guk;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.37-43
    • /
    • 1994
  • Mononitrotoluenes were reduced to aminotoluenes using porphyrin as a catalyst in the presence of several types of reductants including hydrogen sulfide and 1, 4-dithiothreitol(DTT). Intermediates and final products of porphyrin-catalyzed reduction of mononitrotoluenes were identified and a pathway for the reduction of the nitro group to the corresponding amino group was proposed. The optimum pH for the reduction was determined. The catalytic activity of the porphyrin was confirmed by UV/VIS absorption spectra and basic kinetics of porphyrin-catalyzed reduction were studied. Of several types of reductants tested, DTT sodium hydrosulfite, and hydrogen sulfide were seen to give significant reduction of nitrobodies. When hydrogen sulfide was used as a reductant hydrogen sulfide and nitrotoluenes were removed simultaneously.

  • PDF

The Hydrogenation Behaviors of V-xAl (x=1, 5wt.%) Composites by Mechanical Alloying (기계적 합금화법으로 제조한 V-xAl (x=1, 5wt.%) 복합재료의 수소화 반응 거동)

  • Kim, Kyeong-Il;Hong, Tae-Whan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.458-464
    • /
    • 2011
  • Recently, one of the hydrogen production methods has attracted using dense metallic membrane. It has high hydrogen permeation and selectivity which hardly could adopt industrial product because of high cost, hydrogen embrittlment and thermal stability. Meanwhile, vanadium has high hydrogen solubility and it use to instead of Pd-Ag amorphous membrane. Aluminum carried out blocking hydrogen diffusion on grain boundary therefore protecting hydrogen embrittlement. Most of dense metallic membrane is solution diffusion mechanism. The solution diffusion mechanism was very similar hydrogen storing steps such as steps of metal hydride. Thus, V-Al composites were fabricated to use hydrogen induced mechanical alloying. The fabricated V-Al composites were characterized by XRD, SEM, EDS and simultaneous TG/DSC analyses. The hydrogenation behaviors were evaluated using a Sievert's type automatic PCT apparatus. The hydrogenation behaviors of V-Al composites was evaluated too low hydrogen stored capacity and fast hydrogenation kinetics. In PCI results, V-Al composites had low hydrogen solubility, in spite of that, hydrogen kinetics was calculated very fast and hydrogen absorption/desorption contents were same capacity.

Growth and Characterization of Lithium Potassium Phthalate (LiKP) Single Crystals for Third Order Nonlinear Optical Applications

  • Sivakumar, B.;Raj, S. Gokul;Kumar, G. Ramesh;Mohan, R.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3755-3760
    • /
    • 2012
  • Single crystals of lithium potassium phthalate (LiKP) were successfully grown from aqueous solution by solvent evaporation technique. The grown crystals were characterized by single crystal X-ray diffraction. The lithium potassium phthalate $C_{16}\;H_{12}\;K\;Li_3\;O_{11}$ belongs to triclinic system with the following unit-cell dimensions at 298(2) K;$a=7.405(5){\AA}$;$b=9.878(5){\AA}$;$c=13.396(5){\AA}$;${\alpha}=71.778(5)^{\circ}$;${\beta}=87.300(5)^{\circ}$;${\gamma}=85.405(5)^{\circ}$; having a space group P1. Mass spectrometric analysis provides the molecular weight of the compound and possible ways of fragmentations occurs in the compound. Thermal stability of the crystal was also studied by both simultaneous TGA/DTA analyses. The UV-Vis-NIR spectrum shows a good transparency in the whole of Visible and as well as in the near IR range. Third order nonlinear optical studies have also been studied by Z-scan technique. Nonlinear absorption and nonlinear refractive index were found out and the third order bulk susceptibility of compound was also estimated. The results have been discussed in detail.

Characteristics of Gas-liquid Mass Transfer and Interfacial Area in a Bubble Column

  • Lim, Dae Ho;Yoo, Dong Jun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.3
    • /
    • pp.315-320
    • /
    • 2015
  • Characteristics of gas-liquid mass transfer and interfacial area were investigated in a bubble column of diameter and height of 0.102 m and 2.5 m, respectively. Effects of gas and liquid velocities on the volumetric gas-liquid mass transfer coefficient ($k_La$), interfacial area (a) and liquid side true mass transfer coefficient ($k_L$) were examined. The interfacial area and volumetric gas-liquid mass transfer coefficient were determined directly by adopting the simultaneous physical desorption of $O_2$ and chemical absorption of $CO_2$ in the column. The values of $k_La$ and a increased with increasing gas velocity but decreased with increasing liquid velocity in the bubble column which was operated in the churn turbulent flow regime. The value of $k_L$ increased with increasing gas velocity but did not change considerably with increasing liquid velocity. The liquid side mass transfer was found to be related closely to the liquid circulation as well as the effective contacting frequency between the bubbles and liquid phases.

Comparison of Gastrointestinal Permeability of Caffeine, Propranolol, Atenolol, Ofloxacin, and Quinidine Measured Using Ussing Chamber System and Caco-2 Cell Monolayer

  • Song, Im-Sook;Choi, Young A;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.34-38
    • /
    • 2017
  • The purpose of this study was to develop a cocktail approach for the measurement of the permeability of marker compounds, caffeine and propranolol (high permeability), ofloxacin (intermediate), atenolol (low), and quinidine (P-glycoprotein substrate), simultaneously. Then we compared the permeability in Caco-2 cells with that in rat intestinal segments. The difference between individual measurement and cocktail approach was less than 20 %, and the permeabilities of these compounds were similar to those previously reported, suggesting that the cocktail transport study and simultaneous drug analysis were successfully developed and validated in this study. Additionally, in the application of this cocktail method, the permeability of five drugs in rat jejunum was similar to that in ileum but different from that in colon, which was measured using the Ussing chamber system. Moreover, permeability in jejunum and ileum was similar to that in Caco-2 cells. In conclusion, the permeability in Caco-2 cells was equivalent to the permeability in rat jejunum and ileum determined with the Ussing system. Therefore, this newly developed cocktail assay and its application to the Ussing system can be a useful tool for robust and rapid screening for site-specific permeability in rat intestine, thus accelerating the prediction of absorption of new chemical entities.

Simultaneous Preconcentration and Determination of Trace Elements in Water Samples by Coprecipitation-Flotation with Lanthanum Hydroxide $[La(OH)_3]$

  • 김영상;김기찬
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.7
    • /
    • pp.582-588
    • /
    • 1995
  • The preconcentration and determination of trace Cd(Ⅱ), Cu(Ⅱ), Pb(Ⅱ), Mn(Ⅱ) and Zn(Ⅱ) in water samples were studied by the precipitate flotation using La(OH)3 as a coprecipitant. The analytes were quantitatively coprecipitated by adding 3.0 mL of 0.1 M La(Ⅲ) solution in a 1,000 mL water sample and adjusting the pH to 9.5 with NaOH solution. After the addition of the 1:8 mixed surfactant solution of each 0.1% sodium oleate and sodium lauryl sulfate, the solution was stirred with a magnetic stirrer for 10 minutes. The precipitates were floated to the surface by bubbling with nitrogen gas and collected in a small sampling bottle. The precipitates were dissolved in nitric acid and then the solutions were diluted to 25.00 mL with a deionized water. The analytes were determined by flame atomic absorption spectrometry. This procedure was applied to the waste water analysis. This technique was simple, convenient and especially rapid for the analysis of a large volume of sample. And also, from the recoveries of better than 92% which were obtained from real samples, this method could be judged to be applicable to the preconcentration and quantitative determination of trace elements in water samples.

Experimental and numerical study about seismic retrofitting of corrosion-damaged reinforced concrete columns of bridge using combination of FRP wrapping and steel profiles

  • Afshin, Hassan;Shirazi, Mohammad R. Nouri;Abedi, Karim
    • Steel and Composite Structures
    • /
    • v.30 no.3
    • /
    • pp.231-251
    • /
    • 2019
  • In the present study, a numerical and experimental investigation has been carried out on the seismic behavior of RC columns of a bridge which damaged under corrosive environments and retrofitted by various techniques including combined application of CFRP sheets and steel profiles. A novel hybrid retrofitting procedure, including the application of inner steel profiles and outer peripheral CFRP sheets, has been proposed for strengthening purpose. Seven large-scale RC columns of a Girder Bridge have been tested in the laboratory under the influence of simultaneous application of constant axial load and the lateral cyclic displacements. Having verified the finite element modeling, using ABAQUS software, the effects of important parameters such as the corrosion percentage of steel rebars and the number of CFRP layers have been evaluated. Based on the results, retrofitting of RC columns of the bridge with the proposed technique was effective in improving some measures of structural performance such as lateral strength degradation and higher energy absorption capability. However, the displacement ductility was not considerably improved whereas the elastic stiffness of the specimens has been increased.