• 제목/요약/키워드: Simulation code

검색결과 2,962건 처리시간 0.031초

Determination of Exposure during Handling of 125I Seed Using Thermoluminescent Dosimeter and Monte Carlo Method Based on Computational Phantom

  • Hosein Poorbaygi;Seyed Mostafa Salimi;Falamarz Torkzadeh;Saeid Hamidi;Shahab Sheibani
    • Journal of Radiation Protection and Research
    • /
    • 제48권4호
    • /
    • pp.197-203
    • /
    • 2023
  • Background: The thermoluminescent dosimeter (TLD) and Monte Carlo (MC) dosimetry are carried out to determine the occupational dose for personnel in the handling of 125I seed sources. Materials and Methods: TLDs were placed in different layers of the Alderson-Rando phantom in the thyroid, lung and also eyes and skin surface. An 125I seed source was prepared and its activity was measured using a dose calibrator and was placed at two distances of 20 and 50 cm from the Alderson-Rando phantom. In addition, the Monte Carlo N-Particle Extended (MCNPX 2.6.0) code and a computational phantom with a lattice-based geometry were used for organ dose calculations. Results and Discussion: The comparison of TLD and MC results in the thyroid and lung is consistent. Although the relative difference of MC dosimetry to TLD for the eyes was between 4% and 13% and for the skin between 19% and 23%, because of the existence of a higher uncertainty regarding TLD positioning in the eye and skin, these inaccuracies can also be acceptable. The isodose distribution was calculated in the cross-section of the head phantom when the 125I seed was at two distances of 20 and 50 cm and it showed that the greatest dose reduction was observed for the eyes, skin, thyroid, and lungs, respectively. The results of MC dosimetry indicated that for near the head positions (distance of 20 cm) the absorbed dose rates for the eye lens, eye and skin were 78.1±2.3, 59.0±1.8, and 10.7±0.7 µGy/mCi/hr, respectively. Furthermore, we found that a 30 cm displacement for the 125I seed reduced the eye and skin doses by at least 3- and 2-fold, respectively. Conclusion: Using a computational phantom to monitor the dose to the sensitive organs (eye and skin) for personnel involved in the handling of 125I seed sources can be an accurate and inexpensive method.

Evaluation of the CNESTEN's TRIGA Mark II research reactor physical parameters with TRIPOLI-4® and MCNP

  • H. Ghninou;A. Gruel;A. Lyoussi;C. Reynard-Carette;C. El Younoussi;B. El Bakkari;Y. Boulaich
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4447-4464
    • /
    • 2023
  • This paper focuses on the development of a new computational model of the CNESTEN's TRIGA Mark II research reactor using the 3D continuous energy Monte-Carlo code TRIPOLI-4 (T4). This new model was developed to assess neutronic simulations and determine quantities of interest such as kinetic parameters of the reactor, control rods worth, power peaking factors and neutron flux distributions. This model is also a key tool used to accurately design new experiments in the TRIGA reactor, to analyze these experiments and to carry out sensitivity and uncertainty studies. The geometry and materials data, as part of the MCNP reference model, were used to build the T4 model. In this regard, the differences between the two models are mainly due to mathematical approaches of both codes. Indeed, the study presented in this article is divided into two parts: the first part deals with the development and the validation of the T4 model. The results obtained with the T4 model were compared to the existing MCNP reference model and to the experimental results from the Final Safety Analysis Report (FSAR). Different core configurations were investigated via simulations to test the computational model reliability in predicting the physical parameters of the reactor. As a fairly good agreement among the results was deduced, it seems reasonable to assume that the T4 model can accurately reproduce the MCNP calculated values. The second part of this study is devoted to the sensitivity and uncertainty (S/U) studies that were carried out to quantify the nuclear data uncertainty in the multiplication factor keff. For that purpose, the T4 model was used to calculate the sensitivity profiles of the keff to the nuclear data. The integrated-sensitivities were compared to the results obtained from the previous works that were carried out with MCNP and SCALE-6.2 simulation tools and differences of less than 5% were obtained for most of these quantities except for the C-graphite sensitivities. Moreover, the nuclear data uncertainties in the keff were derived using the COMAC-V2.1 covariance matrices library and the calculated sensitivities. The results have shown that the total nuclear data uncertainty in the keff is around 585 pcm using the COMAC-V2.1. This study also demonstrates that the contribution of zirconium isotopes to the nuclear data uncertainty in the keff is not negligible and should be taken into account when performing S/U analysis.

전산유체역학을 이용한 Fischer-Tropsch 마이크로채널 반응기의 채널 구조 영향 분석 (Computational Fluid Dynamics Study of Channel Geometric Effect for Fischer-Tropsch Microchannel Reactor)

  • 나종걸;정익환;;박성호;박찬샘;한종훈
    • Korean Chemical Engineering Research
    • /
    • 제52권6호
    • /
    • pp.826-833
    • /
    • 2014
  • 해양 중소규모 가스전의 경제성에 대한 화두가 던져진 이후 전통 석유의 가격변동과 세계적인 환경규약 등에 맞물려 석유화학관련 산업계에서는 이를 효과적으로 대처하고 천연가스를 활용할 수 있는 공정을 개발하고자 하였다. 이에 Fischer-Tropsch 반응을 기반으로 하는 해상 GTL 공정(offshore gas-to-liquid process)이 제안되었고 부유시스템 platform으로 공정을 적용시키고자 마이크로채널 반응기가 떠오르고 있다. 본 논문에서는 단일 마이크로채널 반응기를 Fischer-Tropsch 반응을 기반으로 하여 Matlab과 ASPEN Hysys를 연동하여 모사하고 이로 얻어진 반응열을 도입해 상용 전산유체역학(computational fluid dynamics, CFD) 소프트웨어인 ANSYS fluent로 멀티 마이크로채널 반응기 모델을 제작하였다. 그리고 4가지의 설계변수인 냉각채널 넓이, 높이, 냉각채널과 반응채널의 간격, 냉각채널 간의 간격을 설정하고 이들의 변화에 따른 열유동을 3가지의 변수인 열유속, 냉각 및 반응채널의 최대온도의 변화를 시각화하여 그 경향성을 확인하였다. 경향성 분석 결과, 냉각채널의 넓이와 높이는 짧을수록 총 열유속이 높아졌으며 최대온도 역시 높아졌으나 냉각채널과 반응채널의 간격은 열유동에 거의 영향을 미치지 못하였다. 냉각채널 간의 간격은 짧을수록 총 열유속이 높아졌으며 최대온도는 낮아졌다. 따라서 적절한 냉각채널의 넓이와 높이를 제안하고 짧은 간격의 냉각채널 구조를 도입하여 반응채널의 열량을 충분히 제거할 수 있는 반응기설계에 대한 휴리스틱을 제안할 수 있었다. 이처럼 멀티채널 반응기의 모델을 설계하고 이로부터 적절한 변수를 선택해 그 경향성을 확인할 수 있는 방법을 통해 설계 단계에서부터 적절한 반응기 구조에 대한 제안을 하는데 도움을 줄 것이다.

천연방사성물질(NORM)을 함유한 가공제품 내 토륨계열 방사능 평가를 위한 간단/신속 분석법 개발 (Development of Simple and Rapid Radioactivity Analysis for Thorium Series in the Products Containing Naturally Occurring Radioactive Materials (NORM))

  • 유재룡;박세영;윤석원;하위호;이재국;김광표
    • Journal of Radiation Protection and Research
    • /
    • 제41권1호
    • /
    • pp.71-79
    • /
    • 2016
  • 연구배경: 생활주변방사선 안전관리법에 의한 가공제품의 방사선학적 안전성 평가를 위해서는 가공제품에 함유된 천연방사성핵종의 정량적 평가가 필요하다. 기존 분석법을 위한 파괴적 전처리는 높은 수준의 기술과 많은 시간이 소요되고, 측정 후 가공제품의 재사용을 불가능하게 하는 단점이 있다. 본 연구에서는 가공제품에 함유된 천연방사성핵종인 토륨계열의 방사능을 평가하기 위해 전처리 과정이 생략되거나 최소화된 방법인 간단/신속 분석법을 개발하였다. 재료 및 방법: 개발된 분석법은 감마분광분석 시스템을 이용하여 전처리 없이 가공제품의 방사능을 간단하고 신속하게 측정하고, 시료의 구성물질, 밀도, 기하학적 형태에 대한 보정을 통하여 방사능을 정확하게 평가할 수 있는 방법이다. 상기 요소에 대한 보정을 위해 변환상수 개념을 도입하였으며, 방사선수송 전산모사를 통해 변환상수를 도출하였다. 본 연구의 대상으로는 일반인이 흔하게 사용하고, 인체에 착용하거나 인체 접촉이 많은 가공제품, 즉 일반인에게 상대적으로 높은 피폭방사선량을 초래할 수 있는 대표적인 가공제품이 선정되었다. 본 연구에서 선정된 가공제품은 건강목걸이, 건강팔찌, 남성용 건강보조기구, 매트 형태의 가공제품에 장착된 타일이었다. 결과 및 고찰: 상기 제품에 대한 변환상수를 Monte Carlo N-Particle eXtended (MCNPX)를 이용하여 도출하였으며, 도출된 변환상수는 0.31-0.47의 범위에 분포하였다. 전처리 없이 가공제품 원형을 그대로 측정한 단순 측정 분석법의 경우 가공제품에 함유된 토륨계열의 방사능은 실제보다 약 2.8배까지 과대평가 되었다. 본 연구에서 개발한 간단/신속 분석법을 사용하는 경우에는 전처리를 통한 정밀분석법과 비교하여 그 차이가 3-24% 정도로 크게 줄어들었다. 결론: 본 연구에서 개발한 분석법은 향후 추가적인 가공제품의 재질 및 형태에 대한 변환상수의 개발을 통해 다양한 가공제품의 방사선학적 안정성 평가에 활용될 수 있을 것이다.

프라이버시 보호 상황인식 시스템 개발을 위한 쌍방향 P3P 방법론 (A Mutual P3P Methodology for Privacy Preserving Context-Aware Systems Development)

  • 권오병
    • Asia pacific journal of information systems
    • /
    • 제18권1호
    • /
    • pp.145-162
    • /
    • 2008
  • One of the big concerns in e-society is privacy issue. In special, in developing robust ubiquitous smart space and corresponding services, user profile and preference are collected by the service providers. Privacy issue would be more critical in context-aware services simply because most of the context data themselves are private information: user's current location, current schedule, friends nearby and even her/his health data. To realize the potential of ubiquitous smart space, the systems embedded in the space should corporate personal privacy preferences. When the users invoke a set of services, they are asked to allow the service providers or smart space to make use of personal information which is related to privacy concerns. For this reason, the users unhappily provide the personal information or even deny to get served. On the other side, service provider needs personal information as rich as possible with minimal personal information to discern royal and trustworthy customers and those who are not. It would be desirable to enlarge the allowable personal information complying with the service provider's request, whereas minimizing service provider's requiring personal information which is not allowed to be submitted and user's submitting information which is of no value to the service provider. In special, if any personal information required by the service provider is not allowed, service will not be provided to the user. P3P (Platform for Privacy Preferences) has been regarded as one of the promising alternatives to preserve the personal information in the course of electronic transactions. However, P3P mainly focuses on preserving the buyers' personal information. From time to time, the service provider's business data should be protected from the unintended usage from the buyers. Moreover, even though the user's privacy preference could depend on the context happened to the user, legacy P3P does not handle the contextual change of privacy preferences. Hence, the purpose of this paper is to propose a mutual P3P-based negotiation mechanism. To do so, service provider's privacy concern is considered as well as the users'. User's privacy policy on the service provider's information also should be informed to the service providers before the service begins. Second, privacy policy is contextually designed according to the user's current context because the nomadic user's privacy concern structure may be altered contextually. Hence, the methodology includes mutual privacy policy and personalization. Overall framework of the mechanism and new code of ethics is described in section 2. Pervasive platform for mutual P3P considers user type and context field, which involves current activity, location, social context, objects nearby and physical environments. Our mutual P3P includes the privacy preference not only for the buyers but also the sellers, that is, service providers. Negotiation methodology for mutual P3P is proposed in section 3. Based on the fact that privacy concern occurs when there are needs for information access and at the same time those for information hiding. Our mechanism was implemented based on an actual shopping mall to increase the feasibility of the idea proposed in this paper. A shopping service is assumed as a context-aware service, and data groups for the service are enumerated. The privacy policy for each data group is represented as APPEL format. To examine the performance of the example service, in section 4, simulation approach is adopted in this paper. For the simulation, five data elements are considered: $\cdot$ UserID $\cdot$ User preference $\cdot$ Phone number $\cdot$ Home address $\cdot$ Product information $\cdot$ Service profile. For the negotiation, reputation is selected as a strategic value. Then the following cases are compared: $\cdot$ Legacy P3P is considered $\cdot$ Mutual P3P is considered without strategic value $\cdot$ Mutual P3P is considered with strategic value. The simulation results show that mutual P3P outperforms legacy P3P. Moreover, we could conclude that when mutual P3P is considered with strategic value, performance was better than that of mutual P3P is considered without strategic value in terms of service safety.

선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션 (Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields)

  • 정동혁;이정옥;강정구;김수곤;김승곤;문성록
    • Radiation Oncology Journal
    • /
    • 제16권2호
    • /
    • pp.195-202
    • /
    • 1998
  • 목적 : 방사선수술의 치료계획에 필요한 기본자료를 얻기 위하여, 6 MV X-선의 소형 조사면을 측정하고, 동일 조사면에 대한 몬테칼로 계산을 수행하여 그 결과를 측정한 자료와 비교하였다. 재료 및 방법 : 연구에 사용한 조사면은 SSD 100 cm에서 직경 1.0, 2.0, 그리고 3.0 cm인 원형의 소형 조사면이며, 각 조사면에 대한 심부선량백분율 (PDD)과 빔측면도 (Beam profile)를 구하였다. 측정에는 소형 반도체검출기, 물팬텀 그리고 원격조정 장치를 이용하였다. 몬테칼로 계산은 EGS4를 이용하여 수행하였으며, 계산에는 6 MV X-선의 에너지 분포와 확산빔 (divergent beam), 원형 조사면 그리고 물팬텀을 고려하였다. 결과 : 심부선량백분율의 경우, 계산값은 측정간에 비하여 낮은 경향을 보였으며, 모든 조사면에 대하여 물팬텀속 깊이 2.0-20.0 cm에서 차이는 0.3-5.7%의 범위로 평가 되었고, 표면 영역에서는 0.0-8.9%로 나타났다. 물팬텀속 깊이 10.0 cm에서 90% 선량폭은 몬테칼로 계산과 잘 일치하였으나, 반음영의 계산값은 모든 조사면에 대하여 측정값보다 0.1 cm 작게 나타났다. 결론 : 측정한 소형 조사면에 대한 심부선량백분율과 빔측면도는 몬테칼로 계산과 근사적으로 일치하였다. 팬텀 표면영역과 반음영 영역에서 측정값과 계산값의 차이가 많이 발생하였으며, 이러한 이유는 몬테칼로 계산 수행시 단순한 기하구조를 가정했기 때문이다. 따라서 실제의 기하구조와 조사면에 대한 보다 정확한 자료를 적용 할 수 있도록, 지속적인 연구를 해야 할 것이며, 몬테칼로 계산은 측정과 검증이 어려운 경우에 대하여 정확한 정보를 얻을 수 있는 유용한 도구로서 많이 이용 될 것이다

  • PDF

신장 방사선 섭취량 결정을 위한 Conjugate View 방법에 대한 평가 (Evaluation of a Conjugate View Method for Determination of Kidney Uptake)

  • 봉정균;윤미진;이종두;김희중;손혜경;권윤영;박해정;김유선
    • 대한핵의학회지
    • /
    • 제39권3호
    • /
    • pp.191-199
    • /
    • 2005
  • 목적: 본 연구의 목적은 신장의 정확한 방사능 섭취량을 얻기 위해서 기하학적 평균 감쇠보정을 이용한 conjugate view 방법(CVM)을 평가하고 Gate 방법과 비교하는 것이다. 대상 및 방법 : 본 연구는 신장의 방사능 섭취량을 시뮬레이션하기 위해서 몬테칼로 코드, SIMIND와 Zubal 팬텀을 사용하였다. 또한 이중 감마카메라를 이용하여 직경 5cm인 팬텀들을 직경 20cm인 실제 팬텀에 삽입하여 실험을 하였다. CVM 방법을 평가하기 위해서 산란과 감쇠가 없는 이상적 데이터와 비교되었다. 또한, CVM 방법을 Gate 방법과 비교하였고, 산란보정의 적용 또는 비적용으로 나누어 CVM 방법을 실행하였다. Gate 방법은 임상에서 사용하는 것처럼 산란보정을 적용하지 않았으며, $0.12cm^{-1}$$0.15cm^{-1}$ 감쇠계수들을 적용하였다. 관심영역 내에 있는 평균계수, 신장영상 위에서 얻어진 프로파일, 선형회귀분석을 이용하여 데이터를 분석하였고, 이상적 데이터와의 상관계수를 계산하였다. 결과: 컴퓨터 시뮬레이션의 경우, 이상적 데이터, CVM 방법, Gate 방법으로부터 얻어진 평균계수들은 각각 (오른쪽: $998{\pm}209$, 왼쪽: $896{\pm}249$), (오른쪽: $911{\pm}207$, 왼쪽: $815{\pm}265$), (오른쪽: $1065{\pm}267$, 왼쪽 $1546{\pm}267$)이었다. CVM 방법은 이상적 데이터와 좋은 상관관계를 보여주었고, 이상적 데이터와 대한 CVM 방법, Gate방법의 상관계수는 각각 (오른쪽: 0.91, 왼쪽: 0.93)와 (오른쪽: 0.85, 왼쪽 0.90)이었다. 결론: 기하학적 평균 감쇠보정을 이용한 CVM 방법은 Gate 방법보다 정량적으로 더 정확한 값을 제공하였다. 결론적으로, 신장 깊이에 영향을 받지 않는 CVM 방법으로 더욱 정확하게 신장의 방사능 섭취량을 측정할 수 있을 것으로 생각된다.

붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구 (Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy)

  • 이동한;지영훈;이동훈;박현주;이석;이경후;서소희;김미숙;조철구;류성렬;유형준;곽호신;이창훈
    • Radiation Oncology Journal
    • /
    • 제19권1호
    • /
    • pp.66-73
    • /
    • 2001
  • 목적 : 붕소-중성자 포획치료법(Boron Neutron Capture Therapy, BNCT)을 위해 원자력병원 싸이클로트론에서 발생되는 최대에너지 34.4 MeV의 속중성자(Fast neutron)를 70 cm 파라핀으로 감속시킨 후 선량 특성을 조사하였다. 그 결과를 토대로 열외중성자(Epithermal neutron) 선량 측정법에 대한 프로토콜을 확립하여 원자로에서 방출되는 열외 중성자 선량 특성 평가의 기초를 삼고, 가속기를 이용한 BNCT 연구에 대한 타당성 여부를 조사하고자 한다. 대상 및 방법 : 공기 중 선량 및 물질 내 선량 분포 측정을 위해 Unidos 10005 (PTW, Germany) 전기계와 조직 등가 물질인 A-150 플라스틱으로 제작된 IC-17 (Far West, USA) 및 IC-18, ElC-1 이온함을 사용하였고, 감마선의 측정을 위해서는 마그네슘으로 제작된 IC-l7M 이온함을 이용하였으며 조직등가 기체와 아르곤 기체를 분당 5cc 씩 주입하며 측정하였다. 중성자, 광자, 전자가 혼합된 장의 모의 수송 해석을 위해 이용되는 Monte Carlo N-Particle (MCNP) transport code를 사용하여 2차원적 선량 분포 및 에너지 분포를 계산하였으며 이 결과를 측정값과 비교하였다. 결과 : BNCT에서의 유효 치료 깊이인 물 팬텀 4 cm에서의 선량은 치료기 1 MU 당 $6.47\times10^{-3}\;cGy$로 미세하였으며, 이때 감마 오염도(contamination)는 $65.2{\pm}0.9\%$로 중성자보다는 감마선에 의한 선량 기여분이 우세하였다. 깊이에 따른 선량 분포 특성에서는 중성자 선량은 선형적으로 감쇠 되었고, 감마선량은 지수적으로 보다 급격히 감쇠되는 경향을 보였으며 전체 선량의 $D_{20}/D_{10}$은 0.718 이었다. MCNP에 의한 에너지 분포 전산 계산의 결과 2.87 MeV 이하에서 중성자 피크가 나타났으며, 저에너지 영역에서는 감마선이 연속적으로 분포되는 양상을 보였다. 결론 : 벽 물질이 서로 다른 두 개의 이온함을 사용한 직접 선량 측정과 MCNP 전산 시뮬레이션을 이용한 공간 선량분포 계산으로 미세 속중성자 빔에 대한 선량 특성을 파악할 수 있었으며, 원자로 열외중성자 주(Epithermal neutron column)에 대한 선량 평가 자료로 확보하였다. 아울러 가속기에 대한 연구가 진행되어 고전압, 고전류를 발생시키는 전원 공급장치와 표적핵(Target) 물질이 개발되고 비스무스나 납 등에 의해 감마 오염도를 줄일 경우, 싸이크로트론에 의한 보론-중성자 포획치료도 가능해질 것으로 판단된다.

  • PDF

에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가 (Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device)

  • 주은빈;안소현;조삼주;금기창;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.31-36
    • /
    • 2016
  • 본 연구에서는 이중에너지 영상을 획득하는 방법으로, 구리판을 이용한 에너지 변조 필터를 사용하였을 때의 선량을 계산 및 측정하였고, 기존의 다른 방법들과 선량을 비교하였다. 몬테칼로 전산모사를 이용하여 에너지 변조 필터에 의한 선량 변화를 평가하기 위하여 MCNPX를 사용하였다. 두경부, 흉부, 복부 촬영에 주로 사용되는 관전압인 80, 120 kVp에 대한 스펙트럼을 SPEC78 프로그램으로 생성하여 선원을 모사하였고, 구리 물질로 이루어진 에너지 변조 필터(밀도: $8.96g/cm^3$)는 두께를 0.5 mm부터 2.0 mm까지 0.5 mm 간격으로 변화시켜가면서 선원으로부터 20.0 cm 거리에 X-선 창을 절반만 가리도록 모델링 하였다. 몬테칼로 전산모사 값과 실제 선량 값을 비교하기 위해서는 교정 상수가 필요하므로, Gafchromic EBT3 필름에 알고 있는 선량을 조사한 후 판독하여 선량 교정 곡선을 획득하였다. 실험과 동일한 조건으로 MCNPX의 f6 tally로 획득한 결과값과 측정값 간의 선량 환산 인자는 $7.2*10^4cGy/output$으로 구해졌으며, 관전압 80 kVp과 관전류 6 mA의 조건으로 콘빔 CT 촬영 시, 평균 10.1 cGy (표준편차 2.7 cGy) 조사됨을 알 수 있었다. 에너지 변조 필터에 기반한 이중 에너지 영상 획득 기술을 적용한 본 연구에서는 이중 에너지 콘빔 CT 시스템의 선량이 단일 에너지 CT 시스템의 선량보다 33~40% 감소함을 알 수 있다. 또한, 에너지 변조 필터에서 발생한 산란선에 의한 선량 증가 효과는 거의 없었다. 따라서, 인체 내 물질 분별력이 우수하여 임상에 널리 응용되었던 기존 이중 에너지 CT 시스템의 상대적으로 피폭선량이 높다는 단점을 효과적으로 개선할 수 있다.

식도암 치료용 $^{166}Ho$-Stent 개발 (Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer)

  • 박경배;김영미;김경화;신병철;박응우;한광희;정영주;최상무;이종두
    • 대한핵의학회지
    • /
    • 제34권1호
    • /
    • pp.62-73
    • /
    • 2000
  • 목적: 식도암은 종양자체 혹은 주위조직의 침범으로 인한 식도 내강의 협착으로 음식물 섭취가 곤란하고 이에 따른 영양결핍, 면역력 약화등으로 생존율이 매우 낮은 것으로 보고되고 있다. 본 연구에서는 좁아진 식도 내강을 넓혀줄 뿐만 아니라 종양에 방사선 치료도 병행할 수 있는 새로운 형태의 식도암 치료용 방사성 stent를 개발하고자 한다. 대상 및 방법: ${\ulcorner}$하나로${\lrcorner}$ 연구로를 이용하여 금속 stent 외부를 $^{166}Ho$ 동위원소가 함유된 원통형의 방사성슬리브로 덮어 씌운 방사성 stent 어셈블리($^{166}Ho$-SA)를 전 방사능화법과 후 방사능화법에 의하여 제조하였다. 결과: 폴리우레탄 :매트릭스 내에 함유되어 있는 $^{165}Ho(NO_3)_3$$^{166}Ho(NO_3)_3$의 분포도를 전자현미경 사진과 자가방사기록법으로 확인한 결과 이들 화합물이 균일하게 분포되어 있음을 알 수 있었다. 식도의 구조적 특성을 고려한 전산용 기하학적인 모델을 개발하여 식도벽에 전달되는 흡수선량을 평가하였다. 본 연구에서 개발된 방사성 stent를 황견을 대상으로 식도부위에 삽입한 결과 육안적으로 점막층의 함몰이 일어나 식도내강이 넓어짐을 확인할 수 있었다. 결론: 금속 stent 외부에 $^{166}Ho$ 동위원소가 함유된 얇은 원통형 sleeve를 덮어씌워 균일한 방사선을 방출할 수 있는 방사성 stent를 개발하였으며, 이를 좁아진 식도부위에 삽입하면 물리적 압력에 의한 식도 내강의 확장과 함께 서서히 방사선 효과에 의해 종양괴사를 유도함으로 시간이 지남에 따라 종양 크기의 증대에 의한 이차적 폐쇄를 현저히 감소시킬 수 있을 것으로 기대된다.

  • PDF