• 제목/요약/키워드: Simulation Result

검색결과 10,003건 처리시간 0.04초

슬라이딩 모드 제어를 이용한 3축 안정화 위성의 자세 제어및 강건성 해석 (Robust attitude control and analysis for 3-axis stabilized spacecraft using sliding mode control)

  • 신동준;김진호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.692-695
    • /
    • 1997
  • Nonlinear robust attitude controller for 3-axis stabilized spacecraft is designed. Robust stability analysis for nonlinear spacecraft system with disturbance is conducted. External disturbances and parametric uncertainties decrease Spacecraft's attitude pointing accuracy. Sliding Mode Control(SMC) provides stability of system in the face of these disturbances and uncertainties. The concept of quadratic boundedness and quadratic stability are applied to the robust analysis for the nonlinear spacecraft system subject to bounded disturbance torques. Numerical simulation is conducted to compare the analysis result and actual nonlinear simulation. The simulation show that analysis result is valid.

  • PDF

자동차용 에어컨 튜브 커넥터의 성능 해석 (Performance Analysis of Automobile Type Air Conditioner Tube Connector)

  • 장성철;김남경
    • 한국기계가공학회지
    • /
    • 제6권2호
    • /
    • pp.52-58
    • /
    • 2007
  • This study shows a numerical method to predict automobile type air conditioner tube connector in the forming process. The simulation approach with 3-D FEM program(ABAQUS) for forming process, forming process simulation is in good agrement with it in tendency. Finally, we compared the forming result with simulation. The result of research showed thai forming process technology is promising to produce automobile type air conditioner tube connector.

  • PDF

유압 브레이커의 리턴 라인의 압력 맥동 감소에 관한 연구 (A Study on the Reducing the Return Line Pressure Fluctuation of the Hydraulic Breaker System)

  • 성원준;노태봉;송창섭
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.70-76
    • /
    • 2003
  • In this study, the hydraulic breaker system was analyzed and simulated using. The simulation result was certified comparing with the experimental result. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the method to reduce the return line pressure fluctuation was presented.

병렬 DEVS 시뮬레이션 환경(P-DEVSIM ++) 성능 평가 (Performance Evaluation of a Parallel DEVS Simulation Environment of P-DEVSIM ++)

  • 성영락
    • 한국시뮬레이션학회논문지
    • /
    • 제2권1호
    • /
    • pp.31-44
    • /
    • 1993
  • Zeigler's DEVS(Discrete Event Systems Specification) formalism supports formal specification of discrete event systems in a hierarchical , modular manner. Associated are hierarchical, distributed simulation algorithms, called abstract simulators, which interpret dynamics of DEVS models. This paper deals with performance evaluation of P-DEVSIM ++, a parallel simulation environment which implements the DEVS formalism and associated simulation algorithms in a parallel environment. Performance simulator has been developed and used to experiment models of parallel simulation executions in different conditions. The experimental result shows that simulation time depends on both the number of processors in the parallel system and the communication overheads among such processors.

  • PDF

시장위험에 대한 금융자산의 종합적 위험관리(VaR모형 중심) (A study on synthetic risk management on market risk of financial assets(focus on VaR model))

  • 김종권
    • 산업경영시스템학회지
    • /
    • 제22권49호
    • /
    • pp.43-57
    • /
    • 1999
  • The recent trend is that risk management has more and more its importance. Neverthless, Korea's risk management is not developed. Even most banks does gap, duration in ALM for risk management, development and operation of VaR stressed at BIS have elementary level. In the case of Fallon and Pritsker, Marshall, gamma model is superior to delta model and Monte Carlo Simulation is improved at its result, as sample number is increased. And, nonparametric model is superior to parametric model. In the case of Korea's stock portfolio, VaR of Monte Carlo Simulation and Full Variance Covariance Model is less than that of Diagonal Model. The reason is that VaR of Full Variance Covariance Model is more precise than that of Diagonal Model. By the way, in the case of interest rate, result of monte carlo simulation is less than that of delta-gamma analysis on 95% confidence level. But, result of 99% is reversed. Therefore, result of which method is not dominated. It means two fact at forecast on volatility of stock and interest rate portfolio. First, in Delta-gamma method and Monte Carlo Simulation, assumption of distribution affects Value at Risk. Second, Value at Risk depends on test method. And, if option price is included, test results will have difference between the two. Therefore, If interest rate futures and option market is open, Korea's findings is supposed to like results of other advanced countries. And, every banks try to develop its internal model.

  • PDF

A Study on the Effectiveness and Improvement of Simulation Training for Apprentice Officers

  • Lee, Myoung-ki;Park, Young-Soo;Ha, Weon-Jae
    • 해양환경안전학회지
    • /
    • 제24권3호
    • /
    • pp.311-318
    • /
    • 2018
  • In accordance with the stipulations of the STCW Convention, simulation training has been enforced in order to develop practical skills so as to prevent accidents by predetermining the risks in special marine environments. Simulation training is a useful way to acquire navigation abilities, and can continuously measure the ability of a trainee by applying an appropriate evaluation. However, the result of training is evaluated by the instructor's subjective judgment without quantitative criteria. Therefore, this study aims to quantitatively evaluate the effectiveness of simulation training. For this purpose, evaluation items were derived by analyzing legal standards, earlier studies, and the current status of MET institutions. The simulations were then performed three times in the same scenarios and analyzed the results. As a result, it has been shown that the objectively analyzed ability to keep the route and to make safe passage with other vessel, as well as subjectively evaluated ability by the apprentice officer has been improved as training progressed. Through the evaluation of simulation training results, it can be derived that simulation education needs supplementation, and can be provided as a basic form of data to quantify the evaluation results of the simulation training in the future.

복수 표면피로균열의 성장합체거동과 시뮬레이션에 관한 연구 (Fatigue Crack Growth, Coalescence Behavior and Its Simulation on Multi-Surface Cracks)

  • 서창민;황남성;박명규
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.716-728
    • /
    • 1994
  • In this paper, fatigue tests were carried out to study the behavior of growth and coalescence of multi-surface cracks which were initiated at the semi-circular surface notches, and a simulation program was developed to predict their growth and coalescence behavior. By comparing the experimental result with those of the simulation based on SPC(surface point connection), ASME and BSI(British Standards Institution) conditions, we tried to enhance the reliance and integrity of structures. This shows that the simulation result has utility for fatigue life prediction.

초음파 시뮬레이션을 이용한 최적의 탐상조건 (Optimal Test Condition by Ultrasonic Simulation)

  • 허선철;박영철;부명환;강정호
    • 한국해양공학회지
    • /
    • 제13권4호통권35호
    • /
    • pp.45-54
    • /
    • 1999
  • Non destructive test is applied to revise mechanical strength and assume material strength or defect of material, equipment and structure, instead of fracture test. Especially, ultrasonic test has the characteristics such as an excellent permeability high-sensitiveness to fine defect and an almost exact measurement for position, size and direction of inner defect which differ from other non destructive tests. In this study, the program is developed to evaluate optimal testing condition, to distinguish obstacle echo and defect position. This program on the basic of Ray-Tracing model shows generation and processing of ultrasonic pulse. The simulation is compared with testing in the 3 cases of an oblique angle transducer like $45^{\circ},\;60^{\circ}\;and\;70^{\circ}$. The test result for all conditions is well compared with simulation result when relative not is within $0.1{\sim}7.2%$. And the course of several echos is simply assumed through simulation.

  • PDF

조명공식을 이용한 시뮬레이션도구의 정확성에 관한 연구 - 점조도 공식과 Lightscape 결과 비교를 중심으로 - (A Study on the exactitude of simulation tool by using Illuminate formula - Focused on the comparing result of Point method and Lightscapet -)

  • 김철훈;이정욱
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.240-243
    • /
    • 2006
  • This thesis is a study on the exactitude of Simulation Tool by using illuminate formula. Lightscape looks like general 3d program, but is a lighting simulation program that set up the properties of materials and light-sources about the model. This thesis calculates illuminance by a formula and simulates a light simulation using Lightscape for two luminaires data in space of ideal environment. As then each value was compared. As a result we got an error under 1% on the whole.

  • PDF

Sensitive analysis of design factor for the optimum design of PVT system

  • Jeong, Yong-Dae;Nam, Yujin
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.5-11
    • /
    • 2015
  • Purpose: Recently, renewable energy system has been widely used to reduce the energy consumption and CO2 emission of building. A photovoltaic/thermal(PVT) system is a kind of efficient energy uses, which is combined with photovoltaic module and solar thermal collector. PVT system removes heat from PV module by through thermal fluid to raise the performance efficiency of the PV system. However, though PVT system has the merit of the improved efficiency in theoretical approach, there have been few performance analysis for PVT system using the dynamic energy simulation. In this study, in order to establish the optimum design method of this system, simulation was conducted by using individual system modules. Method: For the dynamic simulation, TRNSYS17 was used and local weather data was utilized. Furthermore, the system performance in various installation condition was calculated by case studies. Result: As a result, the amount of electric generation and heat production in each case was found by the simulation. The gap of system performance was also evident according to the installation condition.