• Title/Summary/Keyword: Simulated waste water

Search Result 90, Processing Time 0.023 seconds

Simulation of Water Pollution Accident with Water Quality Model (수질모형을 이용한 수질오염사고의 모의분석)

  • Choi, Hyun Gu;Park, Jun Hyung;Han, Kun Yeun
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.3
    • /
    • pp.177-186
    • /
    • 2014
  • Depending on the change of lifestyle and the improvement of people's living standards and rapid industrialization, urbanization of recent, demand for water is increasing rapidly. So emissions of domestic wastewater and various industrial waste water has increased, and water quality is worsening day by day. Therefore, in order to provide a measure against the occurrence of water pollution accident, this study was tried to simulate water pollution accident. This study simulated 2008 Gimcheon phenol accident using 1,2-D model, and analyze scenario for prevent of water pollution accident. Consequently the developed 1-D model presents high reappearance when compared with 2-D model, and has been able to obtain results in a short simulation run time. This study will contribute to the water pollution incident response prediction system and water quality analysis in the future.

Analysis of the sludge thickening characteristics in the thickener using CFD Model (CFD를 이용한 농축조 슬러지의 유출흐름특성 해석)

  • Park, No-Suk;Moon, Yong-Taik;Kim, Byung-Goon;Kim, Hong-Suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.

Study on Utilizing Resources in Ecopolis - Evaluation of Energy floors of Sewage for Enhanced energy system of residence - (생태도시에서의 자원활용에 관한 연구 - 주택 에너지 시스템 개선을 위한 하수 에너지흐름 분석 -)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.911-919
    • /
    • 2003
  • When the city water was heated for the optimum use of unused energy, the energy flows and losses were calculated and evaluated to improve the value of heated water systems at dwelling side. To obtain this purpose, it was simulated on heat flows under two conditions like with heat pumps or not and calculated the energy sayings. Furthermore, recycling water system was suggested for enhancing the value of heated water system. From this results, the energy flows without heat pumps showed that it was 3-4 percents of heat losses from pipes, 62 percents of energy savings from hot water uses and 34 percents of unutilized heat. When the heated water system adopt the recycling water system at dwelling side, it was improved 12 percents of total energy sayings.

Water Gas Shift Reaction Using the Commercial Catalyst Pellets from the Gases by Waste Plastic Gasification (폐플라스틱 가스화에 의한 가스로부터 상용 촉매 펠릿을 이용한 수성가스 전환 반응)

  • JI-MIN YUN;YOUNG-SUB CHOI;JIN-BAE KIM;JIN-BAE KIM;GAB-JIN HWANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.4
    • /
    • pp.327-333
    • /
    • 2023
  • The water gas shift reaction was carried out using the commercial catalyst pellet and the simulated gases expected to occur from waste plastic gasification. In the water gas shift reaction, the high temperature shift reaction and the low temperature shift reaction were continuously performed with CO:H2O ratio of 1:2, 1:2.5, and 1:3, and the CO conversion and H2 increase rate were evaluated. The H2 increase rate increased in order to CO:H2O ratio of 1:3 > CO:H2O ratio of 1:2.5 > CO:H2O ratio of 1:2. The CO conversion showed a high value of more than 97% at each CO:H2O ratio. The water gas shift reaction at a CO:H2O ratio of 1:3 showed the highest H2 increase rate and CO conversion.

Nitrification efficiency of biofilters containing different filter media in simulated seawater aquaculture system

  • Lei Peng;Jo, Jae-Yoon
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2003.05a
    • /
    • pp.203-204
    • /
    • 2003
  • Ammonia in aquaculture system may lead to suppression of fish growth, sublethal histopathological changes, and even death thus ammonia is considered toxic to fish. Tricking filter and submerged filter have many advantages include: low construction cost, easy management and maintenance, and well adaptation to different water and waste loading rates. (omitted)

  • PDF

Feasibility Study and Optimization of Organic Rankine Cycle to Recover Waste Heat of Marine Diesel Engine (유기 랜킨 사이클을 이용한 선박 주기관 폐열회수 시스템의 적용성과 최적화)

  • Lee, Hoki;Lee, Dongkil;Park, Gunil
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2013.12a
    • /
    • pp.103-109
    • /
    • 2013
  • The Present work focuses on application of Organic Rankine Cycle - Waste heat Recovery System (ORC-WHRS) for marine diesel engine. ORC and its combined cycle with the engine were simulated and its performance was estimated theoretically under the various engine operation conditions and cooling water conditions. The working fluid, R245fa, was selected for the consideration of the heat source temperature, system efficiency and safety issues. According to the thermodynamic analysis, ~13.1% of system efficiency of the cycle was performed and it is about 4% of the mechanical power output of the considering Marine Diesel Engine. Also, addition of evaporator and pre-heater were studied to maximize output power of Organic Rankine Cycle as a waste heat recovery system of the marine diesel engine.

  • PDF

Source identification and Pathway analysis of Nitrate contamintation in "Cultural village", Jeungpyeong

  • 전성천;이강근;배광옥;정형재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.254-257
    • /
    • 2002
  • The purposes of this research are to identify the source and to analyze the pathway of nitrate contamination in "cultural village", Jeungpyeong. In order to examine recharge processes and flow pattern that closely related to the influent of nitrate contaminant, the flow field was simulated and the oxygen and hydrogen stable isotopes were analyzed. The nitrogen isotope was used to delineate contaminant sources. The shallow groundwater was mainly composed of precipitation, but leakage of domestic water and sewage contributed to the recharge. Nitrate contaminants were possibly from the leakage of sewage and animal waste. The nitrate concentration decreased due to dilution by low concentration water.ion water.

  • PDF

Electrical Resistivity Variations of Contaminated Soils (오염토양의 전기 비저항치 변화 연구)

  • 윤길림;이용길
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

Study on Current and Water Quality Characteristics in Yongil Bay (영일만내의 유동과 수질특성에 관한 연구)

  • 김헌덕;김종인;류청로
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.28-37
    • /
    • 2001
  • The water quality in Yongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex. The study aims to simulate the current system that is necessary to build ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D model baroclinic model which considers tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most applicable on appearing the current system of the stratificated Yongil Bay difference of density. Form the results of simulation considered tidal current only, it can be clarified that the water body flows in the inner bay through the bottom layer and flows out the outer bay through the surface layer in Yongil Bay. And the fresh water from the Hyongsan river and the thermal discharge form POSCO have a little effect on the current system in Yongil Bay, but the diffusion of heat and salt has an important effect upon the formation of the density stratification of the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system in Yongil Bay.

  • PDF

Study on Current and Water Quality Characteristics in Yongil Bay (영일만내의 유동과 수질특성에 관한 연구)

  • 김헌덕;김종인;류청로
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.246-252
    • /
    • 2000
  • The water quality in Yeongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex The study aims to simulate the current system that is necessary to built ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D baroclinic model considered tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most appliable on the Yongil Bay where current flows slowly and the flow direction is varied by depths. From the results of simulation considered tidal current only, It am be clearly said the water in Yongil Bay flows in through the surface layer and flows out through the bottom layer. And the fresh water from the Hyongsan river and the heated discharge from POSCO have little effect on the current structure in Yonggil Bay, but have and important effect upon the density structure by diffusion of heat and salt. And the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system.

  • PDF