• Title/Summary/Keyword: Simplified correlation method

Search Result 58, Processing Time 0.025 seconds

Stability analysis of closely-spaced tunnel using RFEM (확률유한요소 해석에 의한 근접터널 안정성 분석)

  • Kim, Sang-Gyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.349-360
    • /
    • 2008
  • In this paper, the modeling procedure of random field with an elasto-plastic finite element algorithm and probability of failure on closely-spaced tunnel were investigated. Local average subdivision (LAS) method which can generate discrete random variables fast and accurately as well as change the resolution in certain region was used. And correlated value allocating and weighted average method were suggested to implement geometrical characteristics of tunnel. After the probability of failure on the test problem was thoroughly investigated using random finite element method, the results were compared with the deterministic strength reduction factor method and single random variable method. Of particular importance in this work, is the conclusion that the probability of failure determined by simplified probabilistic analysis, in which spatial variability is ignored by assuming perfect correlation, can be estimated from the safety factor determined by strength reduction factor method. Also, single random variable method can lead to unconservative estimates of the probability of failure.

  • PDF

Development of an Agar Diffusion Method to Measure Elastase Inhibition Activity Using Elastin-Congo Red

  • Jung Kyung-Hwan;Kim Hyun-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.8
    • /
    • pp.1320-1324
    • /
    • 2006
  • The pancreatic and neutrophil elastases are associated with several illnesses including lung and vascular diseases, various cancers, and pancreatitis. The development of a potent and specific inhibitor to the elastases could lead to new therapies. In this study, an agar diffusion method was modified to include a substrate-dye conjugate (Elastin-Congo red) as a substrate of elastase and an indicator of elastase inhibitory activity. The Elastin-Congo red agar plates consisted of 0.1 % Elastin-Congo red and 2.5% agar. The elastase and elastase inhibitors were simultaneously loaded into wells, ultimately resulting in halo formations in which the halo diameter decreased as the concentration of elastase inhibitor increased. The concentration of elastase inhibitor in the samples, therefore, was inversely proportional to the halo diameters. This simplified method provided an excellent correlation with the standard microplate technique, which uses a chromogenic substrate. The concentration of elastase inhibitor obtained from the culture supernatant of a recombinant elastase inhibitor produced by the yeast Pichia pastoris was easily determined. This study has established a simple modified and inexpensive agar diffusion method that is potentially useful for the identification, quantification, and screening of new elastase inhibitors.

The On-Line Measuring of Dissipation Factor on pole Transformer (주상 변압기의 절연유 유전정접 활선 측정 기법)

  • Lee, Su-Kil;Kim, Jae-Chul;Yoon, Yong-Han;Lee, Bo-Hoo;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.853-855
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on the operating transformer by using digital signal processing. After applying voltage to the electrodes which is installed In a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques. we can check the dissipation factor of insulating oil. To Improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Research of $tan{\delta}$ Measurement on Pole Transformer Using DSP (DSP를 이용한 주상변압기 $tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Yoon, Yong-Han;Rim, Sung-Jung;Kim, Oun-Seok;Lee, Su-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.462-463
    • /
    • 1996
  • This study describes the dissipation factor measuring techniques of insulating oil on the operating, transformer by using digital signal processing. After applying voltage to the sensor which is installed in a transformer, acquiring source voltage and current of sensor and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as fast cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by computer simulation, and compared the simplified measuring devices with Schering Bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Research of $Tan{\delta}$ Measurement on pole Transformer Using DSP (DSP를 이용한 주상변압기 $Tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Lee, Su-Kil;Yoon, Yong-Han;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.270-272
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformer by using digital signal processor. After applying voltage to the electrodes which is installed in a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross-correlation techniques and rectangular window techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Iris Segmentation and Recognition

  • Kim, Jae-Min;Cho, Seong-Won
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.3
    • /
    • pp.227-230
    • /
    • 2002
  • A new iris segmentation and recognition method is described. Combining a statistical classification and elastic boundary fitting, the iris is first segmented robustly and accurately. Once the iris is segmented, one-dimensional signals are computed in the iris and decomposed into multiple frequency bands. Each decomposed signal is approximated by a piecewise linear curve connecting a small set of node points. The node points represent features of each signal. The similarity measture between two iris images is the normalized cross-correlation coefficients between simplified signals.

SWIR/VIS Reflectance Ratio Over Korea for Aerosol Retrieval

  • Lee, Kwon-Ho;Li, Zhangqing;Kim, Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Relatively simplified method for determination of surface reflectance has been used by using the ratio between SWIR and VIS band reflectance over land surface. The surface reflectance ratios (SWIR/VIS) were estimated over land in Korea from Terra Moderate Resolution Imaging Spectre-radiometer (MODIS) L1 data. The ratios by using the minimum reflectance technique were lower than those by MODIS operational aerosol retrieval algorithm. Although the comparison between MODIS and sunphotometer Aerosol Optical Thickness (AOT) has a good correlation coefficient (R=0.84), slightly overestimated MODIS AOTs were shown with a slope of linear regression line of 0.89. The comparison between the ratio and AOT dearly exhibit that the error of MODIS AOT could be originated from the underestimated surface reflectances by MODIS operational algorithm.

Design of Lateral Force Estimation Model for Rough Terrain Mobile Robot and Improving Estimation Reliability on Friction Coefficient (야지 주행 로봇을 위한 횡 방향 힘 추정 모델의 설계 및 마찰계수 추정 신뢰도의 향상)

  • Kim, Jiyong;Lee, Jihong;Joo, Sang Hyun
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.3
    • /
    • pp.174-181
    • /
    • 2018
  • For a mobile robot that travels along a terrain consisting of various geology, information on tire force and friction coefficient between ground and wheel is an important factor. In order to estimate the lateral force between ground and wheel, a lot of information about the model and the surrounding environment of the vehicle is required in conventional method. Therefore, in this paper, we are going to estimate lateral force through simple model (Minimal Argument Lateral Slip Curve, MALSC) using only minimum data with high estimation accuracy and to improve estimation reliability of the friction coefficient by using the estimated lateral force data. Simulation is carried out to analyze the correlation between the longitudinal and transverse friction coefficients and slip angles to design the simplified lateral force estimation model by analysing simulation data and to apply it to the actual field environment. In order to verify the validity of the equation, estimation results are compared with the conventional method through simulation. Also, the results of the lateral force and friction coefficient estimation are compared from both the conventional method and the proposed model through the actual robot running experiments.

A Guide on the Use of Factor Analysis in the Assessment of Construct Validity (구성타당도 평가에 있어서 요인분석의 활용)

  • Kang, Hyuncheol
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.5
    • /
    • pp.587-594
    • /
    • 2013
  • Purpose: The purpose of this study is to provide researchers with a simplified approach to undertaking exploratory factor analysis for the assessment of construct validity. Methods: All articles published in 2010, 2011, and 2012 in Journal of Korean Academy of Nursing were reviewed and other relevant books and articles were chosen for the review. Results: In this paper, the following were discussed: preliminary analysis process of exploratory factor analysis to examine the sample size, distribution of measured variables, correlation coefficient, and results of KMO measure and Bartlett's test of sphericity. In addition, other areas to be considered in using factor analysis are discussed, including determination of the number of factors, the choice of rotation method or extraction method of the factor structure, and the interpretation of the factor loadings and explained variance. Conclusion: Content validity is the degree to which elements of an assessment instrument are relevant to and representative of the targeted construct for a particular assessment purpose. This measurement is difficult and challenging and takes a lot of time. Factor analysis is considered one of the strongest approaches to establishing construct validity and is the most commonly used method for establishing construct validity measured by an instrument.

Visible Assessment of Earthquake-induced Geotechnical Hazards by Adopting Integrated Geospatial Database in Coastal Facility Areas (복합 공간데이터베이스 적용을 통한 해안 시설영역 지진 유발 지반재해의 가시적 평가)

  • Kim, Han-Saem;Sun, Chang-Guk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.171-180
    • /
    • 2016
  • Earthquake event keeps increasing every year, and the recent cases of earthquake hazards invoke the necessity of seismic study in Korea, as geotechnical earthquake hazards, such as strong ground motion, liquefaction and landslides, are a significant threat to structures in industrial hub areas including coastal facilities. In this study, systemized framework of integrated assessment of earthquake-induced geotechnical hazard was established using advanced geospatial database. And a visible simulation of the framework was specifically conducted at two coastal facility areas in Incheon. First, the geospatial-grid information in the 3D domain were constructed with geostatistical interpolation method composed of multiple geospatial coverage mapping and 3D integration of geo-layer construction considering spatial outliers and geotechnical uncertainty. Second, the behavior of site-specific seismic responses were assessed by incorporating the depth to bedrock, mean shear wave velocity of the upper 30 m, and characteristic site period based on the geospatial-grid. Third, the normalized correlations between rock-outcrop accelerations and the maximum accelerations of each grid were determined considering the site-specific seismic response characteristics. Fourth, the potential damage due to liquefaction was estimated by combining the geospatial-grid and accelerations correlation grid based on the simplified liquefaction potential index evaluation method.