• 제목/요약/키워드: Simple radiography

검색결과 122건 처리시간 0.032초

응급환자의 방사선영상검사 분포 및 Patient Care (The Distribution and Patient Care in Radiography for Emergency Outpatients)

  • 이환형;강원한
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권1호
    • /
    • pp.55-74
    • /
    • 1996
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distribution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 761 emergency outpatients who visit during JAN, 1994 at ER of the general hospital in Pusan city. The results is as follows: Emergency radiography rate of simple radiography was 61.1 %, special radiography 2.5 %, CT 12.6 %, and ultrasonography 6.7 %. In simple radiography rate, a high rate was distributed on male(63.6 %), thoracicsurgery part(90.0%), admission patient(74.9 %), and long stayed patient at ER. In special raiography rate, a high rate was observed in urologic part(28.6%), and in CT rate, observed neurosurgery part(49.2 %) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8 %) and internal medicine part(15.9 %). There are distributed regional radiography rate in radiographic type that chest(55.3 %) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0 %) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neurosurgery, chest(90.0%) in thoracic-surgery, abdomen(58.0%) in general-surgery, spine (40.0% ) in neuro-surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic-surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiographic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transfered patient(2.7) in patient type, and on neurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional part was highly distributed on chest(499 case number). Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, radiographer should know well about dealing with contrastmedia administration and related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography, Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always silted with CT room and monitoring-patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiography should be established in ER area, and the radiographer of this room should be stationed radiologic technician who is career and can implement emergency patient care.

  • PDF

한 대학병원 응급실 내원환자의 방사선촬영 실태 (Radiographic Status of the Visited Patients at University Hospital Emergency Room)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제5권2호
    • /
    • pp.81-92
    • /
    • 2011
  • 응급상황에서 방사선 촬영 분포 분석 및 문헌을 토대로 응급상황 대처 및 서비스 효율성을 개선시키기 위하여 연구를 하였다. 2010년 12월, 광주 광역시 한 대학병원에 응급실을 내원한 1270명 응급 외래환자를 분석하여 방사선 촬영 분포 데이터를 분석하였다. 결과는 다음과 같다. 응급 방사선 촬영은 56.6% 일반 방사선 촬영, 2.5% 특수촬영, CT 34.2%, 초음파 6.7%였으며, 일반 방사선 촬영에서 남성은 51.7%, 흉부외과의 촬영률 90.0%, 입원환자 77.9% 및 응급실에서 머무르는 시간이 긴 환자에게서 촬영하였다. 특수 촬영의 비율은, 비뇨기계 28.6%, CT에서는 신경외과 49.2%, 신경과 36.7%의 높은 비율을 나타냈다. 초음파의 경우 여성이 8.8%, 내과가 15.9% 비율을 나타냈다. 방사선 촬영의 분포도를 분석하면, 일반 방사선 촬영에서 흉부촬영 55.3%, 특수 촬영에서는 1.2%의 비뇨기계, CT에서는 두부 검사가 40.0%로 높은 비율을 차지했다. 일반 촬영의 진료과의 분포도에 따르면, 두부가 64.6% 신경외과, 흉부검사는 흉부외과는 90.9%, 복부가 58.0% 일반외과, 척추는 신경외과 40.0%, 골반 및 상하지는 정형외과가 15.9%, 20.5%, 31.8%를 차지하였다. 일반 촬영의 환자 1인당 평균검수는 전체 인원을 고려하여 성별, 연령별, 전원 여부별 모두에서 유의한 차이를 나타냈다(p<0.05). 촬영만을 고려한 경우에는 성별에서 남자가 2.2건 높았으며, 연령대에서는 30대에서 2.7건이, 진단부분에서는 신경외과가 3.4건이 더 높게 차지하였다. 전체 촬영 부위 건수에서는 흉부가 998건으로 가장 많았다. 결과를 고려해보면, 응급실에서 근무하는 방사선사는 응급 촬영에서 노년층을 돌봐야 하며, 촬영동안에 가능한 2차 손상을 특수 촬영인 비뇨기계 계통이 기구와 관련이 되어 있기 때문이다. 줄이기 위한 부상응급 환자를 검사하는 모든 방사선사는 방사선 촬영하는 동안에 긴급 상황에 대처해야 한다. 방지 대처가 필요하다. 왜냐하면, 특히 야간에 CT 촬영하는 두부 손상 환자는 환자 처치가 매우 중요하다. 담당 의사는 언제나 CT실에 상주하여 환자를 지켜봐야 한다. 응급실에서 방사선 촬영은 여러 진료과에서 관여 한다. 일반 방사선 촬영의 높은 비율, 응급 방사선 촬영에 대한 특수 촬영실이 응급실 내에 설치하여만 하고, 능력이 있는 응급 환자 처치를 할 수 있는 방사선사가 필요로 하고 응급환자 증가로 적절한 인원배치가 필요하다.

치과위생사의 방사선 촬영업무의 확대에 대한 문헌적 고찰 (A literature review on expansion of dental hygienists' radiography operations)

  • 최영숙;김진경;장종화;박용덕
    • 한국치위생학회지
    • /
    • 제9권2호
    • /
    • pp.111-124
    • /
    • 2009
  • This study analyzes through the review of literature and laws the exposure time, clinical frequency, and radiation exposure of intraoral and extraoral radiography as well as of panoramic radiography performed by dental hygienists in dental clinics, compares the dental radiology curriculums of radiological science and dental hygiene departments, and proposes the expansion of dental hygienists' radiography operations. The radiology curriculums were compared between the radiological science and dental hygiene departments of colleges. For new analysis by radiography for dental diagnosis, the exposure time, radiation absorbed dose, effective dose, and number of days of natural radiation were compared by the type of oral radiation films and radiographical techniques proposed by domestic and international studies. The exposure time of panoramic radiography is 15 seconds and it takes about two minutes for completion, whereas the exposure time of the standard radiography is 0.2~0.8 seconds and it takes 10 times longer for completion of the radiography of full mouth than the panoramic radiography. The standard radiography can cause distortions of radiation at severely curved parts of dental arch and palatopharyngeal reflex. However, panoramic radiography can be performed even for lock jaw patients, causes less inconvenience to patients and is much simpler than the standard radiography. The percentage of dental clinics where radiography is performed by dental hygienists was 92.0%, and the percentage of standard film radiography by dental hygienists was 98% whereas the percentage of panoramic radiography by dental hygienists was 92%. For the absorbed dose which is an indicator of radiation exposure, the When the effective dose which is an indicator of the danger of radiation exposure was converted to the number of days of natural radiation, it was 3.3 days for panoramic radiography, but 13.9 days for the full mouth standard radiography by bisecting angle technique which was 4.2 times longer than the panoramic radiography. There were two colleges that had a dental radiology course with two credits in the departments of radiological science. The credits for dental radiology courses in the department of dental hygiene ranged varied by college, ranging from 3 to 8; on average, the theory course was 2.2 credits and the practice course was 2.02 credits. To summarize the above results, the percentage of dental clinics where panoramic radiography is performed by dental hygienists under the guidance of dentists is high. Panoramic radiography has become an essential facility for dental clinics. It is faster than standard film radiography and less dangerous due to low radiation exposure. Panoramic radiography is a simple mechanical job that does not require training of oral radiography by radiotechnologist. Because panoramic radiography is one of major operations which must be performed at all times in dental clinics, it must be designated as intraoral technique rather than extraoral technique, or legalized for inclusion in the scope of operations of dental hygienists.

  • PDF

성인 늑골에 생긴 단순성 골낭종 $^{18}F$-FDG섭취의 조직학적 근거: 증례보고 및 여러 영상검사 소견과의 비교검토 (Histologic Base of Mild $^{18}F$-FDG Uptake in Simple Bone Cyst of Adult Rib: A Case Report with Multi-image Correlation)

  • 박용휘;강유미;김성훈;오주현
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권4호
    • /
    • pp.328-332
    • /
    • 2008
  • Simple bone cyst (SBC) is very rare in adult ribs. The diagnosis basically relies on conventional radiography and occasionally on a. There has been no earlier publication on PET/CT diagnosis of SBC. We report a case of adult costal SBC diagnosed by positive $^{18}F$-fluorodeoxyglucose (FDG) uptake. Histology showed the FDG uptake to be associated with reactive woven bone formation and nonspecific chronic inflammation. Correlation of PET, CT, plain radiography and sonography are also described.

담도 스텐트 시술 후 장천공 증례보고 및 장천공에 대한 고찰 (A case report of gastrointestinal perforation in patient after biliary stent insertion and the overview of gastrointestinal perforation)

  • 이가영;박찬란;조정효;손창규;이남헌
    • 대한한의학회지
    • /
    • 제43권3호
    • /
    • pp.195-203
    • /
    • 2022
  • Objectives: This study aimed to emphasize the importance of accurate and timely diagnosis of acute abdominal pain with simple radiography by reporting a case of gastrointestinal perforation. Methods: We closely observed the diagnosis and progress of acute abdominal pain after biliary stent and reviewed the outline of gastrointestinal perforation. Results: Patient diagnosed with urethral cancer metastasis to lung and peritoneum was treated with complex Korean medicinal treatments to deal with anorexia, abdominal pain, jaundice and oliguria. During hospitalization, the patient's acute abdominal pain after biliary stent was diagnosed with gastrointestinal perforation by using plain chest and abdominal radiography. Conclusion: Using simple radiography to find out the emergency diseases such as perforation in acute abdominal pain is important clinically.

복부 단순 X선검사시 피복 선량에 관한 연구 (A study on the Radiation exposure of simple abdomen x-ray in Radiography)

  • 고인호;이경성;신동용
    • 대한방사선협회지
    • /
    • 제27권2호
    • /
    • pp.57-65
    • /
    • 2001
  • 본 연구는 복부 단순 X선 검사시 발생하는 피폭선량에 대하여 실험을 수행하였다. 피폭선량을 심부선량 백분율,표면선량,산란선량율으로 각각 측정하였다. 그결과는 다음과 같았다. 1. 관전압이 $60\~85kV$증가시 표면선량은 증가하고, 촬영거리를 50\~150cm$로 20cm씩 증가함에 mAs도 증가시킨 결과 표면선량은 감소되었다. 2. 심부선량 백분율은 $60kV\~75kV$에서는 4cm깊이에서

  • PDF

Impaction of a continuous glucose monitoring sensor

  • Park, Kyong Chan;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • 제48권4호
    • /
    • pp.392-394
    • /
    • 2021
  • A 33-year-old man presented to the plastic surgery department for foreign body removal 1 month after the insertion of a continuous glucose monitoring (CGM) sensor (Dexcom G5) in the left upper arm. The patient had used the CGM system for 5 years, and the insertion was done in the usual manner. The entire sensor wire was visible on simple radiography and ultrasonography. In the operating room, and the sensor wire was identified in the intermuscular septum and removed. No foreign body reaction or inflammatory signs were found around the CGM, and the extracted wire measured 2.5 cm. Thus, it was assumed that the whole sensor wire was detached from the transmitter, not fractured. No remnant foreign body was observed on follow-up simple radiography.

문 개폐 여부와 차폐체 설치 유무에 따른 공간산란선량 측정 : X선 촬영 시 피폭선량 감소방안에 대한 연구 (Measurement of the Spatial Scattering Dose by Opening, Closing Door and Installing Shielding : A Study on the Reduction of Exposure Dose in Radiography)

  • 윤홍주;이용기;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.477-482
    • /
    • 2019
  • Recently, due to the increased use of medical radiation, the radiation exposure of radiation workers should be considered as well as medical exposure of patients. And it is recommended to close the door during radiography. however, In this study, when the door was inevitably opened for radiography, the proposed method was to install the shield as a method of reducing the exposure dose. And its efficiency was analyzed. In simple chest radiography, the measurement point was changed according to the measurement location. Dose rate were measured 10 times for each condition using a dosimeter. And the average value was derived. Using this, the change of dose according to the opening and closing of the door and the installation of the shield was analyzed. Using this, we compared and analyzed the dose change according to the door opening and closing and the installation of the shield, and significance was verified through the SPSS ver. 24. Depending on whether the door was opened or closed, 11,215.35%, 159.0%, 101.9% increased in front of the door in the consol room, behind the wall and behind the lead glass. Depending on the installing of the shield, the 49.2%, 29.6%, 19.9%, 30.6% decrease in front of the door in the examination and consol room, behind the wall and lead glass. In addition, statistical analysis was showed that there were significant differences in both the results according to whether the door was opened or closed and shielding(p<.05). Close the door during radiography. However, when the door should be opened, it was confirmed that the dose rate were reduced by installing the shield. Therefore, to optimize radiation protection, it is recommended to install shields when opening the door.

A pilot study of half-value layer measurements using a semiconductor dosimeter for intraoral radiography

  • Shun Nouchi;Hidenori Yoshida;Yusaku Miki;Yasuhito Tezuka;Ruri Ogawa;Ichiro Ogura
    • Imaging Science in Dentistry
    • /
    • 제53권3호
    • /
    • pp.217-220
    • /
    • 2023
  • Purpose: This pilot study was conducted to evaluate half-value layer (HVL) measurements obtained using a semiconductor dosimeter for intraoral radiography. Materials and Methods: This study included 8 aluminum plates, 4 of which were low-purity (less than 99.9%) and 4 high-purity (greater than 99.9%). Intraoral radiography was performed using an intraoral X-ray unit in accordance with the dental protocol at the authors' affiliated hospital: tube voltage, 60 kVp and 70 kVp; tube current, 7 mA; and exposure time, 0.10 s. The accuracy of HVL measurements for intraoral radiography was assessed using a semiconductor dosimeter. A simple regression analysis was performed to compare the aluminum plate thickness and HVL in relation to the tube voltage (60 kVp and 70 kVp) and aluminum purity (low and high). Results: For the low-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the thickness of the aluminum plate (X), with Y=1.708+0.415X (r=0.999, P<0.05) and Y=1.980+0.484X (r=0.999, P<0.05), respectively. Similarly, for the high-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the plate thickness(X), with Y=1.696+0.454X (r=0.999, P<0.05) and Y=1.968+0.515X (r=0.998, P<0.05), respectively. Conclusion: This pilot study examined the relationship between aluminum plate thickness and HVL measurements using a semiconductor dosimeter for intraoral radiography. Semiconductor dosimeters may prove useful in HVL measurement for purposes such as quality assurance in dental X-ray imaging.

Simple bone cyst recurred in adjacent areas: A case report

  • Jin-Soo Kim
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.383-388
    • /
    • 2023
  • Simple bone cyst is a pseudocyst that typically occurs in patients during their second and third decades of life. This benign entity is an empty or fluid-filled cavity that lacks a true epithelial lining. Simple bone cysts are often asymptomatic and are commonly found in mandibular body, predominantly in the posterior region. The treatment of simple bone cysts can be influenced by factors such as the patient's age, the size of the lesion, and the presence or absence of symptoms. In the case of a simple bone cyst in the mandible that is small and symptomless, a watchful waiting approach may be appropriate. However, if the cyst is large and symptomatic, surgical treatment is recommended. This report presents a radiological examination of a simple bone cyst that developed around the root of the mandibular first molar in a 36-year-old female patient. The cyst recurred in adjacent areas despite surgical treatment.