• Title/Summary/Keyword: Silk suture material

Search Result 10, Processing Time 0.031 seconds

The Effect of Indwelling Silk Suture Material Following Aspiration in the Treatment of Chronic Prepatellar Bursitis (흡인 후 견 봉합사 거치를 통한 만성 슬개골전 점액낭염의 치료)

  • Lee, Bong-Jin;Lee, Sung-Rak;Kim, Chung-Hyun;Kim, Seong-Tae
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.1
    • /
    • pp.55-59
    • /
    • 2005
  • Purpose: To evaluate the drainage effect of silk suture material following aspiration of the bursa as an early treatment of chronic prepatellar bursitis. Materials and Methods: Twelve cases, which have over two weeks of history and over one year of follow-up, were investigated. The average duration of follow-up was 18.3 months. The average symptom duration before introduction into this study was 2.2 months. With an aseptic technique, the aspiration of the bursa was done with spinal needle or injection needle and syringe and then the insertion of silk suture material through the aspiration needle was performed. Over one year follow-up, recurrence, infection, pain, and limitation of range of motion were investigated by telephone interview. Results: Redness around the insertion site of silk suture material was found in all cases, but there was no development of active infection in eleven cases. At five days after procedure, a supprative infection was developed in one case. The results were considered satisfactory in 92% of cases and the average duration of treatment is 14.5 days. Conclusion: The drainage with silk suture material following aspiration of the bursa is effective and less invasive method in the early treatment of chronic prepatellar bursitis.

  • PDF

AN EXPERIMENTAL STUDY OF TISSUE REACTION OF ABSORBABLE SUTURE MATERIALS (수종(數種)의 흡수성(吸收性) 봉합사(縫合絲)가 조직반응(組織反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Song, Sun-Chul;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.381-390
    • /
    • 1991
  • The purpose of this study was to select the absorbable suture material with the lowest level of foreign body reaction in the extraoral field. The absorbable sutures tested were polyglactin 910(Vicryl), polyglycolic acid(Dexon), and chromic gut. Black silk served as to control suture. Eighteen domestic rabbits served as the animal model for testing purposes. After shaving the fur, A six centimeter incision was made in the hind quarter of all eighteen animals. Each wound was then closed wit two Vicryl, two Dexon, and two chromic gut sutures. All wounds were closed in the same manner. A similar wound was made on the oppsite side and closed with black silk suture. Three rabbits were then sacrificed on postoperative day one, three, seven fourteen, twenty-one, and twenty-eight. The surgical sites were then examined histologically. 1. On days one, three, and seven all suture materials as a similar severe level of inflammatory response. On the fourteenth day the inflammatory reaction of Vicryl was minimal, chromic gut was moderate, and Dexon was severe, Black silk control groups demosnstrated the most severe levels of inflammation of all sutures tested from day fourteen to twenty-eight. 2. On the fourteenth day all absorbable suture materials demonstrated similar minimal levels of resorption. At twenty-eight days Vicryl demonstrated a greater amount of resorption than Dexon or cromic gut suture. There was no resorption noted in the black silk control groups through day twenty-eight. 3. Due to its decreased level of inflammatory response in the animal model, Vicryl might be expected to as a decreased level of response in humans. It is felt that Vicryl is preferred to Dexon or chromic gut for extraoral suturing.

  • PDF

Membranes for the Guided Bone Regeneration

  • Lee, Sang-Woon;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.6
    • /
    • pp.239-246
    • /
    • 2014
  • Many kinds of membrane have been used for the guided bone regeneration (GBR) technique. However, most membranes do not fulfill all requirements for the ideal membrane for the GBR technique. Among them, collagen membrane has been most widely used. However, its high price and weak tensile strength in wet condition are limitations for wide clinical application. Synthetic polymers have also been used for the GBR technique. Recently, silk based membrane has been considered as a membrane for the GBR technique. Despite many promising preclinical data for use of a silk membrane, clinical data regarding the silk membrane has been limited. However, silk based material has been used clinically as vessel-tie material and an electrospun silk membrane was applied successfully to patients. No adverse effect related to the silk suture has been reported. Considering that silk membrane can be provided to patients at a cheap price, its clinical application should be encouraged.

A Case of Bronchial Stump Aspergillosis (기관지 단단 국균증 1예)

  • Lee, Hee-Seung;Ryu, Jung-Cheol;Park, Tae-Koon;Park, Tae-Joon;Yang, Eun-Soo;Choi, Soo-Jeon;Kwak, Young-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.299-301
    • /
    • 1994
  • Bronchial stump aspergillosis(BSA) is an infrequent disease developing on the bronchial stump after lobectomy with the silk as a suture material. The silk induces inflammatory reaction, granuloma formation, secondary infection of the bronchial stump and leads to BSA. If a patient complains of cough, hemoptysis, expectoration of suture material several months or years after lobectomy with the silk, BSA should be considered as one of causative mechanisms. Bronchoscopic identification of silk thread with aspergillosis and its removal is necessary. We report a case of BSA in a 59-year-old man with review of the literature.

  • PDF

Reliability of Early Ambulation after Intradural Spine Surgery : Risk Factors and a Preventive Method for Cerebrospinal Fluid Leak Related Complications

  • Lee, Subum;Cho, Dae-Chul;Kim, Kyoung-Tae;Lee, Young-Seok;Rhim, Seung Chul;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.799-807
    • /
    • 2021
  • Objective : Cerebrospinal fluid leakage related complications (CLC) occasionally occur after intradural spinal surgery. We sought to investigate the effectiveness of early ambulation after intradural spinal surgery and analyze the risk factors for CLC. Methods : For this retrospective cohort study, we enrolled 314 patients who underwent intradural spinal surgery at a single institution. The early group contained 79 patients who started ambulation after 1 day of bedrest without position restrictions, while the late group consisted of 235 patients who started ambulation after at least 3 days of bed rest and were limited to the prone position after surgery. In the early group, Prolene 6-0 was used as the dura suture material, while black silk 5-0 was used as the dura suture material in the late group. Results : The overall incidence rate of CLC was 10.8%. Significant differences between the early and late groups were identified in the rate of CLC (2.5% vs. 13.6%), surgical repair required (1.3% vs. 7.7%), and length of hospital stay (2.99 vs. 9.29 days) (p<0.05). Logistic regression analysis revealed that CLC was associated with practices specific to the late group (p=0.011) and the revision surgery (p=0.022). Conclusion : Using Prolene 6-0 as a dura suture material for intradural spinal surgery resulted in lower CLC rates compared to black silk 5-0 sutures despite a shorter bed rest period. Our findings revealed that suture - needle ratio related to dura defect was the most critical factor for CLC. One-day ambulation after primary dura closure using Prolene 6-0 sutures appears to be a costeffective and safe strategy for intradural spinal surgery.

A Study on Sterilization of Medical Products by Gamma-irradiation. (Gamma선 조사에 의한 의류제품의 멸균연구)

  • 정해원;정문식;문석형
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1978
  • Biological safety, physico-chemical and microbiological experiments were carried out in order to study the possibility of radiation sterilization on medical products, such as polyethylene and polystyrene bottles, gauze sponges and surgical silk suture. Results are as follows: 1. Biological test on plastic samples as to acute systemic toxicity, eye irritation, skin irritation, pyrogen, haemolysis showed satisfactory results. But physico-chemically, the oxidizable matter, nonvolatile residues, residue on ignition seemed to be increased slightly in irradiated samples, though the experimental results were within the range of U.S.P. 19, N.F. and K.P. III. 2. After irradiation, both plastic and gauze sponges showed considerable decrease in pH. 3. Most medical products were sterilized by 1.5 Mard. For the sterilization of the suigical silk suture, 4.5 Mrad is required dul to its radiation resistant micro-organisms. 4. Biologically, total dose of 2.5 Mrad was safe enough to sterilize the medical products, and physico-chemically the results are acceptable according to U.S.P. 19 and K.P. III. However, better results may be expected when the quality of material and additives are improved.

  • PDF

TISSUE HEALING RESPONSE OF INCISED WOUND SUTURED BY STAPLES AND VARIOUS SUTURE MATERIALS (Staple과 수종의 봉합물의 봉합부위 창상치유 조직반응)

  • Suh, Min-Jung;Lee, Jae-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.500-514
    • /
    • 1996
  • The purpose of this study was to observe the tissue response in applying staples and various suture materials to both scalp and buccal mucosa in rabbits. 18 rabbits were divided into 6 groups. The incised wounds of both scalp and buccal mucosa were sutured with staples, polyglactin 910, chromic catgut, mer silk and nylon. The experimental animals were sacrificed after 1, 3, 5, 7, 10, 14 days posto peratively 3 animals at one time. The tissue was stained with Hematoxylin and eosin, and Masson's Trichrom. In light microscopic examinations, the sutured sites were examined histologi cally according to 6 degrees about inflammation and collagen deposit. The results were obtained as follows, 1. The chromic catgut, an absorbable suture material, was absorbed by 7 days, whereas polyglactin 910 and mersilk began to get absorbed after 7 days. 2. Mersilk manifested a broad range of inflammation in the scalp, and both staple and nylon showed a severe inflammatory reaction in the buccal mucosa. 3. With polyglactin 910, both tissue samples showed only minor foreign body reaction, however in the scalp, the process of fibrosis took place compara tively slowly, whereas in the buccal mucosa, it occurred promptly and manifested active fibrosis by 7 days. 4. Mersilk showed widespread a matrix formation in both scalp and buccal mucosa, and showed the most severe inflammatory reaction by 3 days, which did not seem to decrease even after 7 days. 5. Both staple and nylon showed relatively a severe inflammatory reaction, however fibrosis took place rather promptly compared to the other groups. 6. Generally, in the buccal mucosa fibrosis occurred more promptly than in the scalp in both control and experimental groups. 7. Retention of the suture material and stability of the knot were the best with the staple, and better stability was manifested by the multi-stranded poly glactin 910 and mersilk than singlestranded chromic catgut and nylon. From above results, in the buccal mucosa absorbable suture materials especially polyglactin 910 showed better response in the aspect of inflammatory reaction, while in the scalp monofilament suture materials such as staple and nylon manifested a early fibrosis and collagen formation.

  • PDF

Pain and quality of life related to suture removal after 3 or 7 days at the extraction sites of impacted lower third molars

  • Rodanant, Pirasut;Wattanajitseree, Kannika;Shrestha, Binit;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.2
    • /
    • pp.131-136
    • /
    • 2016
  • Background: This study aimed to evaluate the patient's pain and quality of life after suture removal at either 3 or 7 days following the bilateral surgical extraction of impacted lower third molars. Methods: This study was a prospective, randomized controlled clinical trial carried out in 30 patients, who acted as their own control. Each patient required the bilaterally impacted mandibular third molars to be extracted. The impacted teeth were removed and the wound margins were approximated and sutured with black braided silk. The suture material was removed on day 3 on one side and on day 7 on the other. Each participant was asked to complete a questionnaire after the removal of the suture material on each designated day. Results: Regarding overall clinical symptoms, the mean VAS scores of male and female participants on day 3 were not significantly different from those on day 7. A significant difference was found in female participants, in that overall daily activity was better on day 7. There were significant differences in the ability to smile and laugh in both sexes and the ability to chew in the male participants was better on day 7. Conclusions: There were no significant differences in the patient's pain and quality of life between suture removal on day 3 or on day 7 following surgery to remove impacted lower third molars.

A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

  • Bektas, Cem Inan;Kankaya, Yuksel;Ozer, Kadri;Baris, Ruser;Aslan, Ozlem Colak;Kocer, Ugur
    • Archives of Plastic Surgery
    • /
    • v.40 no.6
    • /
    • pp.711-714
    • /
    • 2013
  • Background The most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds. Methods Between March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm). First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion. Results The mean follow-up was 7 months (range, 2-10 months) in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent. Conclusions In our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

Uptake of Fibroin Microspheres by 3T3 Cells (3T3 세포에 의한 피브로인 마이크로스피어의 흡수)

  • Lee, Jin Sil;Go, Nam Kyung;Lee, Shin Young;Hur, Won
    • KSBB Journal
    • /
    • v.29 no.5
    • /
    • pp.328-335
    • /
    • 2014
  • Vehicle toxicity is one of the main obstacles for intracellular delivery of bioactive compounds. Silk fibroin is a natural polymer proven to have high biocompatibility since being used as suture material. In this report, fibroin microspheres were prepared without any chemical modification or cross-linking not to affect its biocompatibility. The microspheres were taken up by more than 90% of 3T3 cells. Cellular uptake continued after medium replenishment with a different-colored fluorescent microsphere, suggesting that simultaneous ingestion and exocytosis occurred. Cellular uptake of fibroin microspheres did not affect cell viability. Intracellular trafficking of the microspheres using lysosome-specific fluorescent dye revealed that fibroin microspheres were localized both in the cytoplasm and in the lysosome. Accordingly, fibroin microspheres can be a potential vehicle for intracytoplasmic delivery of large cargos, such as mixtures of proteins, nutrients or artificial organelles.