• 제목/요약/키워드: Silicone Elastomer

검색결과 26건 처리시간 0.029초

Evaluation of bonding efficiency between facial silicone and acrylic resin using different bonding agents and surface alterations

  • Shetty, Uttam Sadashiv;Guttal, Satyabodh Shesharaj
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.121-126
    • /
    • 2012
  • PURPOSE. The aim of the study was to evaluate the effect of 3 silicone primers and 3 surface characterization of acrylic resin surface on bond strength between silicone elastomer and acrylic resin. MATERIALS AND METHODS. 96 Cosmesil silicones bonded to heat-curing acrylic resin were fabricated with the dimension of $75{\times}10{\times}3$ mm. The 3 primers used in this study were G611 platinum primer, A-330 Gold platinum primer, and cyanoacrylates resin. Specimens without primer were used as control. The 3 types of surface characterization done were retentive holes with 1.5 mm in diameter and 0.5 mm deep, retentive beads of 0.6 mm diameter and the third type which was plain without any characterization. The specimens were then checked for bond strength by subjecting them to $180^{\circ}$ peel test on a universal testing machine. The obtained results were then subjected to statistical analysis using 2-way ANOVA and Scheff$\acute{e}$ multiple post hoc procedures. The statistical significance was set at 5% level of significance. RESULTS. The maximum bond strength was seen for samples in which A-330G primer was used followed by G611 primer. The control group showed the minimum bond strength. Surface characterization of retentive holes increased the bond strength considerably as compared to retentive beads and samples without any surface characterization. CONCLUSION. Within the limitations of the study, A-330G primer was more compatible with Cosmesil M511 silicone and has better bonding of Cosmesil to acrylic resin. Retentive holes made on acrylic surface increased the bond strength considerably than those without any surface characterization.

Color stability of thermochromic pigment in maxillofacial silicone

  • Kantola, Rosita;Lassila, Lippo V.J.;Tolvanen, Mimmi;Valittu, Pekka K.
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.75-83
    • /
    • 2013
  • PURPOSE. Maxillofacial silicone elastomer is usually colored intrinsically with color pigments to match skin colors. The purpose of this study was to investigate the color stability of a maxillofacial silicone elastomer, colored with a thermochromic, color changing pigment. MATERIALS AND METHODS. Disc-shaped maxillofacial silicone specimens were prepared and divided into 3 groups: a conventionally colored control group, one group additionally colored with 0.2 wt% thermochromic pigment, and one group with 0.6 wt% thermochromic pigment. Half of the surface of each specimen was covered with an aluminium foil. All of the specimens were exposed to UV radiation in 6 hour cycles over 46 days. In between the UV exposures, half of the specimens were stored in darkness, at room temperature, and the other half was stored in an incubator, at a humidity of 97% and a temperature of $+37^{\circ}C$. Color measurements were made with a spectrophotometer and registered according to the CIELAB $L^*a^*b^*$ color model system. The changes in $L^*$, $a^*$ and $b^*$ values during artificial aging were statistically analyzed by using paired samples t-test and repeated measures ANOVA. P-values <.05 were considered as statistically significant. RESULTS. The UV exposure resulted in visually noticeable and statistically significant color changes in the $L^*$, $a^*$ and $b^*$ values in both of the test groups containing thermochromic pigment. Storage in the incubator lead to statistically significant color changes in the $a^*$ and $b^*$ values of the specimens containing thermochromic pigment, compared to those stored at room temperature. CONCLUSION. The specimens containing thermochromic pigment were very sensitive to UV radiation, and the thermochromic pigment is not suitable, as such, to be used in maxillofacial prostheses.

유연 복합재료 전극 제조 및 표면조도에 따른 접착 특성에 대한 연구 (A Study on the Fabrication of Flexible Composite Electrodes and Its Bonding Characteristics According to Surface Roughness)

  • 이한영;정경채;한민구;장승환
    • Composites Research
    • /
    • 제27권6호
    • /
    • pp.242-247
    • /
    • 2014
  • 전기활성고분자의 종류 중 하나인 유전성 탄성체의 거동에 대응할 수 있는 유연전극 제조에 대한 연구를 수행하였다. 전도성 고분자(PEDOT:PSS)에 가소제 역할을 하는 자이리톨(Xylitol)을 첨가하여 기계적 특성을 평가하였다. 자이리톨을 첨가한 전극의 유연성을 확인하기 위해 실리콘 시편에 전극을 도포하여 인장시험을 수행하였다. 자이리톨을 70 wt% 첨가한 조건에서 연신률이 크게 증가함을 확인하였고 실리콘 거동에 큰 영향을 미치지 않는 것을 확인하였다. 또한, 전극과 실리콘의 접착성을 향상시키기 위해 표면조도가 다른 실리콘 필름을 제작하였으며 사포 #120으로 처리한 시편에서 실리콘 필름과 전극의 접착성이 향상됨을 확인하였다.

악안면 보철용 실리콘의 물리적 특성 및 색조안정성에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES AND COLOR STABILITY OF MAXILLOFACIAL PROSTHETIC SILICONE MATERIAL)

  • 박찬진;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.330-343
    • /
    • 1997
  • Extraoral maxillofacial prostheses are essential for restoring facial structures that are lost as a result of congenital missing, injuries from accidents, surgical treatments of head and neck cancer. Recently, silicone is the most useful material for this purpose and is more advantageous than other maxillofacial prosthetic materials. However, there are some problems for long-term usage of silicone prostheses due to tear and color change. These are major contributing environmental factors to those problems that are such as ultraviolet light, cleansing agents, changes in humidity and successive adhesion and removal. The aim of this study is to evaluate the physical properties and color changes of maxillofacial prosthetic silicone material by those environmental factors using A-2186 silicone material (Factor II, USA) and two pigments, cadmium yellow medium and cosmetic red. Aluminium molds were fabricated according to the ASTM No. D412 & D624 specifications and resulted specimens from molds were fabicated and treated as follows. Control group and experimental I group were fabricated with 0.1% wt. pigment mixing in silicone elastomer and II-1 group, II-2 group of experimental II group were fabricated with 0.2%, 0.3% wt. pigment mixing in silicone elastomer, respectively. Control group was kept in darkroom at room temperature, I-1 group was kept under natural sunlight during 1week, I-2 group was soaked in 20% soap water during 1wk. I-3 group was successively adhered and removed 200 times on inner region of arm using Daro adhesive-33. Experimental II groups were kept in darkroom at room temperature. Instron universal testing machine was used to measure the % elongation, tensile strength, tear strength of control, experimental I, II groups and reflectance spectrophotometer(COLOR EYE-3000, Macbeth, USA) was used to measure the color differences between control group and experimental I group. The results were as follows : 1. When compared with control group, natural weathering group and 20% soap-water soaking group had no significant differences in % elongation(p>0.05). 2. 200 times successive adhesion and removal group, 0.2% wt. pigment group and 0.3% wt. pigment group had significant decreases in % elongation(p<0.05). 3. Natural weathering group, 20% soap-water soaking group and 200 times successive adhesion and removal group had no significant differences in tensile strength (p>0.05). 4. 0.2%, 0.3% wt. pigment groups had significant decreases in tensile strength(p<0.05). 5. Values of all experimental groups were decreased in tear strength. and 200 times successive adhesion and removal group had significant decrease in tear strength(p<0.05). 6. Natural weathering group and 20% soap-water soaking group had significant color differences(${\Delta}E$) and it could be detectable to naked eye(p<0.05). 7. Color differences between control group and 200 times adhesion and removal group were not detectable to the naked eye (${\Delta}E<1.0$).

  • PDF

레이저에 의해 패터닝 된 바늘과 탄성중합체와의 마찰 효과 (Investigation of friction effects between needles patterned using laser and elastomer)

  • 김재구;노승국;박종권;조성학;황경현
    • 한국레이저가공학회지
    • /
    • 제15권3호
    • /
    • pp.1-6
    • /
    • 2012
  • The friction force of patterned needle in elastomer have been investigated to verify the application for bio and plastic industry. The micro pattern on the needle surface were prepared by 266 nm, 20 ns laser and 800 nm, 220 fs laser, which were able to generate the different surface roughness. The friction force was measured by the load cell of 10 N capacity. As the results, the friction force of no patterned needle is almost constant during the needle penetrates the silicone rubber sample. However, the needle having asperities shows the variation of the friction force. The higher the surface roughness is, the smaller the friction force is until the surface roughness is very high. In our experiment conditions, the reduction of the friction force by 20 % compared to no pattern needle was achieved with straight and $50{\mu}m$ discrete line generated by 266 nm, 20 ns laser.

  • PDF

액체금속과 백금촉매실리콘을 이용한 초탄성 스트레인게이지 (Development of Hyperelastically Stretchable Strain Gauge based on Liquid Metals and Platinum Catalyzed Silicone Elastomers)

  • 김석범;최범규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1235-1236
    • /
    • 2015
  • This paper reports hyperelastically stretchable strain gauges based on liquid metal (eutectic gallium-indium;EGaIn) and a platinum-catalyzed silicone elastomer ($Ecoflex^{TM}$). A custom liquidmetal patterning setup was operated to fabricate liquidmetal straingauge on flexible substrate. The printed strain gauges were tested under cyclic uniaxial stretching, twisting, even bending of human finger. By engineering the orientation of solid wires placed over two terminals of t he printed liquid metal resistor, we stably achieved the stretchability of ~800 % which is the highest value reported so far, to the best of our knowledge.

  • PDF

자외선 차단제가 악안면 실리콘의 색변화에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECT OF UV LIGHT ABSORBER ON THE COLOR CHANCE OF MAXILLOFACIAL SILICONE)

  • 송윤석;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.343-357
    • /
    • 1999
  • The color change of maxillofacial silicone has been attributed to certain environmental factors such as exposure to the UV component of natural sunlight, wetting and drying of the elastomer and surface abrasion resulting from the application and removal of cosmetics. The purpose of this study was to evaluate the color change of maxillofacial silicone (Silastic MDX4-4210) according to type of pigment (cadmium yellow, titanium white, cosmetic red), and UV absorber application method after 200, 400, and 600 hours of 350nm UV light irradiation. The results were as follows. 1. According to type of pigments, after 200 hours cosmetic red showed significantly larger color change than cadmium yellow and titanium white, and after 400 and 600 hours color change significantly decreased in the order of cosmetic red, cadmium yellow, and titanium white (p<0.05). 2. In the cadmium yellow group, after 200 hours, the non-treatment group showed significantly larger color change, but after 400 and 600 hours, color change significantly decreased in the order of non-treatment, surface application and mixed group (p<0.05). 3. In the titanium white group, there was no significant color change difference between the three groups after 200 and 400 hours, but after 600 hours, the mixed group showed significantly smalt or color change than the non-treatment and surface application groups (p<0.05). 4. In the cosmetic red group, there was significant decrease in color change in the order of non-treatment, surface application and mixed group (p<0.05). From the results above, the effect of UV light absorber differed according to the type of pigment, but mixing UV light absorber with maxillofacial silicone is thought to give superior resistance against UV light irradiation in the long run.

  • PDF

고차단성 자동차 부품용 고무소재 (Elastomeric High Barrier Materials for Vehicle)

  • 김진국
    • Elastomers and Composites
    • /
    • 제46권1호
    • /
    • pp.2-9
    • /
    • 2011
  • 가스와 증기에 대한 투과성(Permeability to gases and Vapors)은 고무 제품을 타이어 튜브나 다이아후램(diaphragm)과 같은 제품으로 사용하고자 할 때 아주 중요한 특성이다. 모든 고무는 가스와 증기에 대하여 투과성이 있다. 그러나 그 투과 속도는 고무 재질에 따라 아주 다르다. 일반적으로 실리콘 고무의 투과성이 제일 크고, 그 다음으로 NR, EPDM, SBR, CR, NBR, FPM, ECO, IIR 순이다. 이러한 투과성은 같은 원료고무를 사용해도 사용 배합약품의 종류에 따라 크게 다를 수도 있다. 고무와 기체와의 메커니즘은 발포고무에 매우 중요하게 되어 이에 대한 연구$^{1-7}$는 많이 이루어졌으나 고무의 차단성에 대한 연구는 그리 많지 않다. 고무소재의 투과성 또는 차단성 기능을 주기위하여 나노복합탄성체$^8$의 기술 동향 및 코팅에 의한 기능성 향상$^{9-13}$을 하거나 열가소성탄성체 본문에서 적용하는 기술이 있는데 자동차에 사용되는 액체 및 기체 차단용 고무부품에 대하여 몇가지 소개하여 본다.

실리콘 변성 폴리아크릴졔 Hybrid Elastomer의 제조와 그 특성 (Preparation and Characteristics of Silicone Modified Polyacrylic Hybrid Elastomer)

  • 이병철;강두환
    • 폴리머
    • /
    • 제31권1호
    • /
    • pp.86-91
    • /
    • 2007
  • Polydimethylsiloxane prepolymer와 2-hydroxyethyl methacrylate (HEMA)를 이용하여 Polydimethylsiloxane을 도입한 HEMA(SH)를 제조하였다. 여기에 methacrylic acid (MA), allyl glycidyl ether(AGE) 및 aminopropyltrimethoxysilane (APTS)를 이용하여 실록산 변성 polyacrylate hybrid(SMPA)를 제조하고 이들의 구조를 FTIR 및 $^1H-NMR$로 확인하였다. SMPA에 대한 내열특성을 TGA를 통해 측정한 결과 $400^{\circ}C$에서 무게 잔존율($W_{tr}$, %)은 APTS의 함량이 증가할수록 55에서 63%로 증가하여 나타났다. 제조한 SMPA에 증점제, 가교제 등의 각종 첨가제들을 가하여 SMPA 실란트를 제조하였다. 접착특성을 측정한 결과 SMPA-3를 이용하여 제조한 실란트의 경우 concrete와 금속사이의 최대 하중 신장률은 2.01%. 파괴 하중 신장률은 2.28%로 SMPA-1 및 SMPA-2를 이용하여 제조한 실란트의 1.07, 1.45%와 1.02, 1.35%인 경우보다 증가되었다.

수종의 영구 탄성 이장재와 의치상용 레진간의 인장 결합 강도 (COMPARISON ON TENSILE BOND STRENGTH OF PERMANENT SOFT DENTURE LINERS BONDED TO THE DENTURE BASE RESIN)

  • 김래규;정문규;임순호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.200-211
    • /
    • 1999
  • For many years permanent soft denture liners has been widely used in dental practice directly or indirectly because of its function in absorbing and distributing the impact force. However, it reveals problems such as lack of permanency and decreased bond strength in long term use. The purpose of this study is to measure the bond strength and failure between denture base resin and several permanent liners. Lucitone 199 was used as denture base resin with soft acrylic liners (Triad, Tokuso Rebase) and silicone elastomers (Tokuyama, Ufi Gel C) bonded to measure the tensile strength before and after thermocycling. The thermocycling was done in 2000 cycles at $5^{\circ}C,\;26^{\circ}C\;and\;55^{\circ}C$ and the measured tensile strength values before and after thermocycling were compared. The mode of failure was investigated in the separated specimens. The results are as follows. 1. As to tensile strength, the strongest material is Tokuso Rebase followed by Triad, Tokuyama, Ufi Gel C in before thermocycling and the order of Triad, Tokuso Rebase, Tokuyama, Ufi Gel C in after thermocycling state. There was significant difference between the values of Triad, Tokuso Rebase and Tokuyama, Ufi Gel C(p<0.05). 2. As to degree of displacement, Ufi Gel C showed most displacement with or without thermo-cycling treatment and also the difference was significant with the other materials(p<0.05). 3. As to comparisons before and after thermocycling, Tokuso Rebase and Tokuyama showed significant difference in bond strength, whereas Triad and Tokuso Rebase showed significant difference in the degree of displacement(p<0.05). 4. In debonded specimens, Triad and Ufi Gel C showed adhesion failure and Tokuyama showed cohesion failure. Both failures were observed in Tokuso Rebase with adhesion failure up to 70%. The results of this study showed that degree of bond strength between permanent soft denture liner and denture base resin were variable. There was a significant difference between soft acrylics and silicone elastomers with regard to bond strength. Further research in improving bond strength of widely used silicone elastomers and in developing the method of measuring bond strength between denture base resin and the lining materials is needed.

  • PDF