• Title/Summary/Keyword: Silicone

Search Result 1,466, Processing Time 0.03 seconds

Effect of Fiber Dispersion on Mechanical Strength of SiCf/SiC Composites (강화 섬유의 분산도가 SiCf/SiC 복합소재의 기계적 강도에 미치는 영향)

  • Ji Beom Choi;Soo-Hyun Kim;Seulhee Lee;In-Sub Han;Hyung-Joon Bang;Seyoung Kim;Young-Hoon Seong
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.180-185
    • /
    • 2023
  • This paper investigates the impact of fiber dispersion on the internal structure and mechanical strength of SiCf/SiC composites manufactured using spread SiC fibers. The fiber volume ratio of the specimen to which spread SiC fiber was applied decreased by 9%p compared to the non-spread specimen, and the resin slurry impregnated between the fibers more smoothly, resulting in minimal matrix porosity. In order to compare the fiber dispersion of each specimen, a method was proposed to quantify and evaluate the separation distance between fibers in composite materials. The results showed that the distance between fibers in the spread specimen increased by 2.23 ㎛ compared to the non-spread specimen, with a significant 42.6% increase in the distance between fiber surfaces. Furthermore, the 3pt bending test demonstrated a 49.3% higher flexural strength in the spread specimen, accompanied by a more uniform deviation in test data. These findings highlight the significant influence of SiC fiber dispersion on achieving uniform densification of the SiCf/SiC matrix and increasing mechanical strength.

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

  • Eun-Bin Bae;Won-Tak Cho;Do-Hyun Park;Su-Hyun Hwang;So-Hyoun Lee;Mi-Jung Yun;Chang-Mo Jeong;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.155-170
    • /
    • 2023
  • PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 ㎛ but there was no statistically significant difference within the groups (P > .05). CONCLUSION. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 ㎛ in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.

Reproducibility Evaluation of Shear Wave Elastography According to the Depth of the Simulated Lesion in Breast Ultrasonography (유방초음파 검사에서 모조 병소의 깊이에 따른 전단파 탄성초음파의 재현성 평가)

  • Jin-Hee Kim;In-Soo Kim;Cheol-Min Jeon;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.919-927
    • /
    • 2023
  • Elastography utilizes the fact that the tissue of a malignant tumor is harder than that of a benign tumor and increases the specificity of diagnosis according to the elastic modulus of the tumor, helping to reduce unnecessary biopsies. However, the reliability of elastography can be influenced by the equipment used and the examiner's skills. In this study, the researchers analyzed the reproducibility of elastography by evaluating phantom images when measuring the elasticity values repeatedly. Phantoms were created using silicone and gelatin with different levels of stiffness, and they were inserted at varying depths from the surface. The elasticity values were measured using shear wave elastography. The study aimed to determine whether the reproducibility of elasticity values remains consistent depending on the stiffness and depth of the lesions. The experimental results showed that there was no statistically significant correlation between the elasticity values obtained through shear wave elastography and the depth or stiffness of the lesions. However, in the lesions with the lowest stiffness, the elasticity values were statistically significant (p<0.001) and showed a high correlation with the depth of the lesions. Although there were variations in the measured elasticity values based on the differences in lesion stiffness and depth, these differences did not significantly impact the diagnosis. Therefore, shear wave elastography remains a reliable diagnostic method, and it is suggested that it can be helpful in the diagnosis of breast lesions.

24 Hour Esophageal PH Monitoring in Preterm Infants (미숙아에서의 24시간 식도 PH 검사)

  • Park, Jeung-Hyun;Park, Beom-Soo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.133-141
    • /
    • 2001
  • Purpose: Gastroesophageal reflux (GER) has been found to be the causative factors of apnea, stridor, feeding intolerance, poor weight gain, and sudden infants death syndrome (SIDS) in infants. GER is a well-described in infants and children, but only scant mention of the premature infants with GER can be found in the literature. Methods: Esophageal pH was measured during 24 hour in 21 healthy preterm infants, using a silicone microelectrode with an external reference electrode connected to a portable recorder. The mean age of the patients was $29{\pm}8$ days, mean gestational age was $30^{+5}{\pm}2^{+0}$ weeks, mean birth weight was $1,468{\pm}329$ g, mean postconceptional age was $34^{+6}{\pm}1^{+4}$ weeks and mean weight was $1,750{\pm}329$ g. We evaluated the following reflux parameters; number of acid reflux, number of long acid reflux, longest acid reflux minutes, and reflux index. Results: Pathologic GER was detected in 12 (57%) subjects and most interesting parameters are reflux index and number of episodes with a pH<4 during 24 hour (high correlation with postprandial reflux index). Reflux was not correlated to gestational age, birth weight, age, postconceptional age, weight, sex and medication of the theophylline. Conclusion: Gastroesophageal reflux is common in preterm infants, but it is usually not apparent, even with severe reflux.

  • PDF

A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD (침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구)

  • Kay, Kee-Sung;Chung, Chae-Heon;Kang, Dong-Wan;Kim, Byeong-Ok;Hwang, Ho-Gil;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF

Progress of Composite Fabrication Technologies with the Use of Machinery

  • Choi, Byung-Keun;Kim, Yun-Hae;Ha, Jin-Cheol;Lee, Jin-Woo;Park, Jun-Mu;Park, Soo-Jeong;Moon, Kyung-Man;Chung, Won-Jee;Kim, Man-Soo
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.3
    • /
    • pp.185-194
    • /
    • 2012
  • A Macroscopic combination of two or more distinct materials is commonly referred to as a "Composite Material", having been designed mechanically and chemically superior in function and characteristic than its individual constituent materials. Composite materials are used not only for aerospace and military, but also heavily used in boat/ship building and general composite industries which we are seeing increasingly more. Regardless of the various applications for composite materials, the industry is still limited and requires better fabrication technology and methodology in order to expand and grow. An example of this is that the majority of fabrication facilities nearby still use an antiquated wet lay-up process where fabrication still requires manual hand labor in a 3D environment impeding productivity of composite product design advancement. As an expert in the advanced composites field, I have developed fabrication skills with the use of machinery based on my past composite experience. In autumn 2011, the Korea government confirmed to fund my project. It is the development of a composite sanding machine. I began development of this semi-robotic prototype beginning in 2009. It has possibilities of replacing or augmenting the exhaustive and difficult jobs performed by human hands, such as sanding, grinding, blasting, and polishing in most often, very awkward conditions, and is also will boost productivity, improve surface quality, cut abrasive costs, eliminate vibration injuries, and protect workers from exposure to dust and airborne contamination. Ease of control and operation of the equipment in or outside of the sanding room is a key benefit to end-users. It will prove to be much more economical than normal robotics and minimize errors that commonly occur in factories. The key components and their technologies are a 360 degree rotational shoulder and a wrist that is controlled under PLC controller and joystick manual mode. Development on both of the key modules is complete and are now operational. The Korean government fund boosted my development and I expect to complete full scale development no later than 3rd quarter 2012. Even with the advantages of composite materials, there is still the need to repair or to maintain composite products with a higher level of technology. I have learned many composite repair skills on composite airframe since many composite fabrication skills including repair, requires training for non aerospace applications. The wind energy market is now requiring much larger blades in order to generate more electrical energy for wind farms. One single blade is commonly 50 meters or longer now. When a wind blade becomes damaged from external forces, on-site repair is required on the columns even under strong wind and freezing temperature conditions. In order to correctly obtain polymerization, the repair must be performed on the damaged area within a very limited time. The use of pre-impregnated glass fabric and heating silicone pad and a hot bonder acting precise heating control are surely required.

Effects of Methylprednisolone on TGF-${\beta}1$, Apoptosis and Renal Scarring in Experimental Acute Pyelonephritic Weaning Rats (실험적 급성 신우신염이 유발된 이유기 백서에서 methylprednisolone이 TGF-${\beta}1$, 세포고사 및 신반흔에 미치는 영향)

  • Whang, Soo-Ja;Sung, Soon-Hee;Lee, Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.6 no.1
    • /
    • pp.75-84
    • /
    • 2002
  • Purpose Acute pyelonephritis of growing kidneys may result in renal scarring. TGF-${\beta}1$, inflammatory cytokine, has been suggested to play an important role in promoting renal scarring through apoptosis, suppression of cellular proliferation and fibrosis. We observed the effects of a potent anti-inflammatory agent, methylprednisolone on apoptosis and renal scarring in experimentally induced acute pyelonephritic weaning rats. Materials and Methods: To induce ascending pyelonephritis a saline solution containing Escherichia coli type ATCC No. 25922, pili- form (107 bacteria/mL) was infused into the bladder through the 16-guage silicone cannula for 48 hours to 102 three-week-old Sprague-Dawley rats (50-60g). Experimental groups were divided into three groups according to the treatment protocols, group I (ceftriaxone only, n=3l), group II (methylprednisolone+ceftriaxone n=28), control group (n=43) was not treated. Histopathologic scores of inflammatory changes, fibrosis and tubular atrophy, the apoptosis index and TGF-${\beta}1$ expression score were observed at post-infection 1 and 3 week. Datas were analysed using ANOVA test and P value below 0.05 was interpreted as significant. Results: The mortality rate ($21.4\%$) of group II was not different to the control group ($41.9\%$) and group I ($32.3\%$). The inflammatory score of group II ($0.8{\pm}0.87$) at week 1 was significantly lower than those of the control group ($2.3{\pm}0.87$) and Group I ($1.7{\pm}0.79$) (P<0.05). Apoptosis index of group II ($2.9{\pm}2.15$) at week 1 was significantly lower than those of the control group ($10.0{\pm}1.95$) and group 1 ($8.3{\pm}2.53$) (P<0.05). TCF-${\beta}1$ expression score of group II ($0.8{\pm}0.72$) at week 1 was significantly lower than those of the control group ($1.9{\pm}0.68$) and group I ($1.8{\pm}0.60$) (P<0.05). The fibrosis score of group II ($1.1{\pm}1.10$) at week 3 was significantly lower than that of the group I ($1.8{\pm}0.83$) (P<0.05) Conclusion: Conclusion Combined treatment with methylprednisolone and ceftriaxone reduced inflammation, fibrosis, apoptosis and TGF-${\beta}1$ expression in acute pyelonephritic weaning rats, compared to ceftriaxone alone. Anti-inflammatory agent supplemented to antibiotics could prevent renal scarring more effectively. (J Korean Soc Pediatr Nephrol 2002 ; 6 : 75-84)

  • PDF

The Short Term and Intermediate Term Results of using a T-tube in Patients with Tracheal Stenosis (기관 협착 환자에서의 T-튜브의 중단기 결과)

  • Sa, Young Jo;Moon, Seok-Whan;Kim, Young-Du;Jin, Ung;Park, Jae-Kil;Kim, Jae Jun;Kim, Chi-Kyung;Jo, Keon Hyon;Park, Chan Beom;Yim, Hyeon Woo
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • Background: The treatment of tracheal stenosis includes less invasive bronchoscopic intervention and more invasive segmental resection & anastomosis. Depending on the patient's clinical features, sometimes all these methods are inappropriate. Silicone T-tube stenting has recently been used as an alternative, safe management of tracheal stenosis. We studied the short term and Intermediate term results of using T-tubes in patients with tracheal stenosis, and this tracheal stenosis was caused by various underlying diseases. Material and Method: We retrospectively reviewed 57 patients with tracheal stenosis and who were treated with T-tubes between Jan 1997 and Apr 2007. Based on the patient's medical records and the imaging studies, we evaluated the clinical findings and status of T-tube removal. Result: There was no T-tube related morbidity or mortality in this series. On follow-up, one patient underwent sleeve resection and end-to-end anastomosis. The T-tube could be successfully removed from 13 patients (13/57, 22.8%) without additional interventions. For another four patients, a T-tube was again inserted after removal of the first T-tube due to tracheomalacia or recurrent stenosis. Four patients died of underlying disease and cancer. The patients' gender and previous tracheostomy significantly affected T-tube removal. By contrast, multiple logistic regression analysis identified gender as a predictor of successfully removing a T-tube. Gender (p=0.033) and previous tracheostomy (p=0.036) were the two factors for success or failure of T-tube removal. Conclusion: A T-tube provided reliable patency of a stenotic airway that was caused by any etiology. We have proven that using a T-tube is safe and effective therapy for patients with tracheal stenosis for the short term or the intermediate term.

A study on the reduction on magnetic susceptible artifacts through the usage of silicon (실리콘을 이용한 자화율 인공물의 감소에 관한 연구)

  • Choi, Kwan-Woo;Lee, Ho-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5937-5942
    • /
    • 2012
  • This study used silicon that is similar to the density of the tissue of the human body to compensate for the uneven areas that are in contact with air in order to reduce susceptible artifacts. The subjects of the study were 16 normal people and the areas of the human body in which there are a lot of uneven areas with complicated structure and a lot of susceptible artifacts were formed since the surface area that comes into contact with the air is large were the areas that were chosen to be examined. A 3.0T superconducting magnetic resonance device was used as the test equipment and SPIR images that are sensitive to magnetic differences were obtained as sagittal planes on a line that extended the metatarsal and the phalanges, including the middle of the longitudinal arc and the 5 distal phalanxes. The method of analysis was to reduce the susceptibility between the tissue and the air to discover the reduction of susceptible artifacts by comparing the SNR and CNR before and after applying silicon. A statistical analysis was utilized for the sample matching T examination. The results of the study revealed that the susceptible artifacts were reduced in the images of the uneven areas that were compensated and applied with silicon. The SNR increased in significant amount in correlation from $3.91{\pm}1.33$ before application to $21.69{\pm}4.52$ after application and the CNR decreased in significant amount in correlation from $28.97{\pm}8.20$ before application to $4.88{\pm}2.14$. In conclusion, this study did not affect the voxel but it was an innovative method of improvement that compensated for the fundamental issue of the difference in susceptibility between the air and the body. The application is simple and the study has great significance in that it proposed a method to reduce susceptible artifacts in a low cost and highly efficient manner.

Contact Lens Prescribing Pattern in Korean During 2010 to 2013 (대한민국의 최근 4년간(2010-2013) 콘택트렌즈 처방 추세)

  • Lee, Jong-Ha;Lee, Ki-Seok;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.323-329
    • /
    • 2014
  • Purpose: To understand the pattern of prescribing contact lenses in Korea from 2010 to 2013. Methods: Four hundred survey questionnaires were randomly posted to Korean Optometric clinics for 4 years. The questionnaire was the same form as a form used for International Contact Lens Prescribing Trend. It was also designed to collect information about the contact lenses prescribed to the first 10 patients after its receipt. Results: 1937 fits were used for the analysis among the four hundred survey questionnaires. The average patient age was $26.2{\pm}7.0$ in 2010, $26.1{\pm}7.6$ in 2011, $24.7{\pm}6.6$ in 2012 and $24.8{\pm}7.2$ in 2013. The patients were mainly women (75%). Of all the soft contact lenses, silicon hydrogel lenses were 18% of fits (17% in 2010, 10% in 2011, 20% in 2012, 24% in 2013). By degine, the percentage of toric design lenses accounted for 17% of soft lenses fits and had increased during 4 years (10% in 2010, 18% in 2011, 16% in 2012, 22% in 2013), and cosmetic contact lens made up for 29% (15% in 2010, 20% in 2011, 40% in 2012, 41% in 2013). Conclusions: The contact lenses wearers were mostly women and the average patient age becomes slightly younger. In relation to the increase in the mumber of younger female contact lens wearers,the percentage of cosmetic lenses prescription was much higher (29%) than the global average (7%), and it has gradually increased for last 4 years. This trend could be related to the growth of beauty market in Korea. By emphasizing on toric lens marketing in manufactures, the prescription rate has been gradually increased.