• Title/Summary/Keyword: Significant peak

Search Result 2,034, Processing Time 0.027 seconds

A Study on the Kinematic Variables in Different Safety Shoes and Applying Insole During Walking (안전화 형태와 인솔착용 유무에 따른 보행동작시 하지부위에 대한 운동학적 부하 분석)

  • Kim, Jung-Jin;Choi, Sang-Bock;Cha, Sang-Eon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.1
    • /
    • pp.35-45
    • /
    • 2008
  • This study was performed to compare the kinematics among three different safety shoes(type 1: ergonomically designed and high quality shoes, 2: curved and cushioned safety shoes, and 3: regular safety shoes) and to find the effect of insole during walking. Ten healthy subjects were recruited for this study. The range of motion of knee and ankle joint, angle of rear foot and angle of heel contact were measured using a three dimensional motion analysis system. In the second peak, the angle of heel contact showed statistically significant difference between safety shoes and insole, however, there was no statistical significance among three different safety shoes. The angle of ankle increased significantly at initial contact, first peak, the second peak and the toe off phase compared with type 1 and 2 safety shoes, and the angle of ankle showed statistically significant difference between with and without applying the insole. During the first peak, the second peak and the toe off phase, the angle of knee was statistical significance between safety shoes and insole. In heel contact, the angles of Achilles' tendon showed statistically significant difference between safety shoes and insole. The rear foot angles showed statistically significant difference between safety shoes and insole during heel contact and early heel contact. These results suggest that the type 1 safety shoes were superior to others in the statistics, and applying insole could be a possible method to prevent fatigue of lower extremity and musculoskeletal disorders. Further studies are needed to find the effect of ergonomically designed safety shoes and insole on practical value in prevention of musculoskeletal disorder, fatigue and satisfaction of workers.

The effects of kinesio taping of thigh muscle on isokinetic muscular function during closed kinetic chain exercise of lower extremity (하지의 닫힌 사슬 운동시 대퇴부 테이핑 적용이 등속성 근기능에 미치는 영향)

  • Kim, Sang-Yeup;Yoon, Young-Ieoi;Choi, Won-Jye
    • PNF and Movement
    • /
    • v.8 no.3
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate effects of kinesio taping of thigh muscle on isokinetic muscular function during closed kinetic chain exercise of lower extremity. Methods : Twenty healthy males were participated in this study. The isokinetic muscular function of closed kinetic chain were measured for peak torque, peak torque % body weight, average power, max rep tot work before and after application of kinesio taping on thigh muscles. Results : At $60^{\circ}/s$ peak force and peak force % body weight were significant increased in both extension(p<0.01) and flexion(p<0.001) after applying kinesio taping. At $180^{\circ}/s$ average power was significant increased in both extension and flexion after applying taping(p<0.001). At $240^{\circ}/s$ max rep tot work was significant increased in both extension(p<0.001) and flexion(p<0.05). Conclusion : This study suggests that application of kinesio taping on thigh muscle was more effective to improve isokinetic muscular function in closed kinetic chain exercise of lower extremity.

  • PDF

The Scientific Research of Rehabilitation Training Program Participants in Stroke Patients (재활운동에 참가한 뇌졸중환자의 운동과학적 연구)

  • Jin, Young-Wan
    • Journal of Life Science
    • /
    • v.20 no.11
    • /
    • pp.1704-1710
    • /
    • 2010
  • The purpose of this study was to describe the biomechanical characteristics of stroke patients. These characteristics were obtained during walking on a Zebris system, cinematography system and EMG system. Seven female stroke patients participated in this study. The magnitude of the profiles (joint peak angle, joint peak moments, foot pressure COP, EMG data) correlated with rehabilitation training duration using t-test. The significance level selected for this study was p<0.05, t-test. Joint analysis identified significant differences in hip joint peak angle and hip joint peak moment. Foot pressure verified significant differences in gait line length of COP. The EMG signal proved significant differences in rectus femoris and vastus lateralis.

Correlation between Metabolite Peak Area Ratios on the Influence of Poor Shimming by $^1H$ MR Spectroscopy

  • Baik, Hyun-Man;Choe, Bo-Young;Suh, Tae-Suk;Lee, Hyuong-Koo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.3 no.2
    • /
    • pp.140-148
    • /
    • 1999
  • Using 1H magnetic resonance spectroscopy (MRS), we quantitatively evaluated correlation representing linear relationship between the metabolite peak area ratios associated with poor shimming conditions. The inadequate shimming due to linear shim offsets directly affected overall MR spectral quality as well as peak area for each metabolite. Three major peaks such as N-acetylaspartate (NAA), creatine (Cr,) choline (Cho) were used as a reference for data analysis. Despite considerable variations of metabolite peak area, a significant correlation between the metabolite peak area ratios relative to Cr was established while the correlation between the peak area ratios relative to Cho and NAA was not. The present study suggested that metabolite peak area ratios based on the metabolite of Cr could be an acceptable quantification method even under the poor shimming in clinical MRS examination.

  • PDF

A Study on Estimate Model for Peak Time Congestion

  • Kim, Deug-Bong;Yoo, Sang-Lok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.3
    • /
    • pp.285-291
    • /
    • 2014
  • This study applied regression analysis to evaluate the impact of hourly average congestion calculated by bumper model in the congested area of each passage of each port on the peak time congestion, to suggest the model formula that can predict the peak time congestion. This study conducted regression analysis of hourly average congestion and peak time congestion based on the AIS survey study of 20 ports in Korea. As a result of analysis, it was found that the hourly average congestion has a significant impact on the peak time congestion and the prediction model formula was derived. This formula($C_p=4.457C_a+29.202$) can be used to calculate the peak time congestion based on the predicted hourly average congestion.

Texture Profile Analysis of Acorn Flour Gels (도토리묵의 물리적 특성)

  • Kim, Young-A;Rhee, Hei-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.345-349
    • /
    • 1985
  • The textural properties of acorn flour gels were investigated with the variations in the concentraction, storage time and storage temperature by the use of Instron Universal Testing Machine. The experimental design was $3^3$ factorial experiment. TPA curves of acorn flour gels showed two sharp peaks in the first bite and no negative peak. The hardness and brittleness of acorn flour gels were very significantly affected by concentration, storage time and storage temperature. For the height difference between first peak and second peals, the main effects for concentration and storage temperature were very significant and the main effect for storage time was not negligible. For bend, the effect of concentration was more significant than the effect of storage temperature, and storage time effect was negligible. Springiness was affected only by the concentration.

  • PDF

Characteristics of Foot Pressure Distribution with or without Partial Prosthetic Foot in Transmetartarsal Amputee (경중족 절단 환자의 의족지 착용에 따른 족저압력 분포 특성)

  • Seong, Woo-Sung;Yang, Hee-Seung;Sung, Hong-Kee;Kim, Hak-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • Purpose: This study was designed to evaluate characteristics of foot pressure distribution with or without partial prosthetic foot in transmetatarsal amputee. Materials and Methods: The subjects were 9 transmetatarsal amputees. Foot pressures were measured at hallux, the $1^{st}-5^{th}$ metatarsal head (MTH), mid-foot, condyle area by F-scan system in amputated or contralateral foot during active walking. Results: In amputated foot, mean peak pressure was greatest in midfoot without prosthetic foot but it was greatest in hindfoot with prosthetic foot. In unaffected foot, although mean peak pressure was higher in hallux, and $1-5^{th}$ MTH compared to amputated foot, it was greatest in hind foot both with and without prosthetic foot. However, in unaffected foot, mean peak pressure significantly decreased in hallux and $5^{th}$ MTH after wearing the prosthetic foot. There was a significant difference in mean peak pressure in hallux and $5^{th}$ MTH between amputated and unaffected foot after wearing prosthetic foot. However, other region had no significant difference with or without prosthetic foot between feet. Conclusions: The use of partial prosthetic foot tends to shift weight bearing from the heel area to forefoot and could significantly reduce hind foot peak pressure and redistributed to peak pressure. The partial prosthetic foot can also offer the peak pressure to reduction both amputated foot and unaffected foot and help to toe off during walking.

  • PDF

Characteristics of Transmittance Spectrum of Korean Red Ginseng Using VIS/NIR (가시광선 및 근적외선을 이용한 홍삼의 투과스펙트럼 특성)

  • 손재룡;이강진;최규홍;김기영;강석원;최동수;장익주
    • Journal of Biosystems Engineering
    • /
    • v.29 no.4
    • /
    • pp.329-334
    • /
    • 2004
  • This study was conducted to investigate the characteristics of transmittance spectrum of Korean red ginseng using VIS/NIR spectroscopy. The results of this study were as follows; Light intensity affected the characteristics of the spectrum. For over 40% light intensity, the first and second peaks appeared at 700nm and 1,100nm, respectively. For the 20% light intensity, the first and second peaks appeared at 800nm and 1,100nm, respectively. Thus, the typical color characteristics of halogen lamp were similar to each other if over 40% of maximum light intensity power, otherwise it was not. Transmittance spectrum showed different characteristics at different portions of red ginseng. Normal red ginseng showed strong intensity at the first peak around 700nmbecause of reddish internal tissue. However, an internal white core red ginseng showed weak peak-intensity due to whitish internal tissue. There was no significant difference in the second peak at 800nm for the different internal qualities. Third peak at 900nm showed somewhat difference by internal qualities but it was difficult to find significant trend. To separate the differences of the internal qualities, intensity differences between peaks were used. It was possible to classify normal red ginseng by the differences of "peak 1 -peak 2" and "peak 1 - peak 3". In addition, shift of the first and the third peaks in the spectrum could separate normal red ginseng from others.ginseng from others.

Effects of Abdominal Functional Electrical Stimulation on Peak Cough Flow and Forced Vital Capacity in Patients with Cervical Spinal Cord Injury (복부 기능적전기자극이 목척수손상환자의 최대기침유량과 노력성폐활량에 미치는 효과)

  • An, Hyein;Ko, Youngbum;Youn, Sunhwa;Cha, Suhwan;Jeon, Yongjin
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.85-93
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the effects of abdominal functional electrical stimulation on peak cough flow and forced vital capacity in patients with cervical spinal cord injury. Methods : The study examined 20 patients with cervical spinal cord injury. The subjects were randomly divided into two groups. All subjects performed conservative physical therapy for 30 minutes. The experimental group also underwent abdominal functional electrical stimulation for at least 20 minutes per day. Abdominal functional electrical stimulation was applied to the rectus abdominis muscle twice each day, three times a week, for four weeks. In all subjects, the peak cough flow was measured using a peak flow meter and forced vital capacity was assessed using a spirometer. Results : The experimental group showed a significant increase in peak cough flow and forced vital capacity in pre-post measurements (p<.05), while the control group showed a significant increase only in peak cough flow. Conclusion : These findings suggest that conservative physical therapy in combination with the abdominal functional electrical stimulation can improve peak cough flow and forced vital capacity in patients with cervical spinal cord injury.

A study of calculate a time to peak enhancement of contrast level by using blood flow (혈류에 의한 조영제 peak time의 산출에 관한 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong;Lee, Ho-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2315-2321
    • /
    • 2013
  • This study attempt to develope and suggest a new, minimize side effects process for calculate a time to peak enhancement of contrast level by using blood flow instead of current mathematical process. We conducted a studies 127 patients who performed the CE MRA by using test-contrast inject way. We used measurements of a contrast inflow time and time to peak enhancement of contrast level of each cerebrovascular branch for similarity of witch cerebrovascular branch calculate a time to peak enhancement of contrast level by using blood flow in image compared with calculation a time to peak enhancement of contrast level by using current mathematical process after contrast enhancement. In this study, confidence interval were used if the variable is continuous variable; there is differences between 4 groups exist but in group 1, there is no difference with time in peak enhancement of contrast level by using mathematical method to inflow time in sinus sigmoideus. it was significant statistically, in addition there was significant low heterogeneity in Bland Altman plot. Thus, apply a new calculate a time to peak enhancement of contrast level by using blood flow method will minimize damage caused by side effect, maintain quality of image, easy and fast access. It should provide a space for the exchange of current calculate a time to peak enhancement of contrast level by using mathematical process.