• 제목/요약/키워드: Signal-to-noise Ratio

검색결과 3,035건 처리시간 0.037초

Superparamagnetic Iron Oxide-Enhanced MRI를 이용한 간섬유화의 평가: 영상의학적 비침습적 간섬유화 지표가 AST/혈소판 비와 상관 관계가 있는가? (Evaluation of Fibrosis in Liver Cirrhosis by Superparamagnetic Iron Oxide (SPIO)-Enhanced MR Imaging: Does the Radiological Non-Invasive Fibrosis Index Correlate with the Laboratory Non-Invasive Fibrosis Index?)

  • 김신기;이창희;김경아;최재웅;이종미;박철민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.115-122
    • /
    • 2008
  • 목적: SPIO-enhanced MRI상에서 얻은 radiological non-invasive hepatic fibrosis index (RNHFI)와 AST/혈소판 비(AST to platelet ratio index, APRI)간의 상관관계를 알아보고자 하였다. 대상 및 방법: 5년동안 SPIO-enhanced MRI를 시행받은 환자들을 대상으로 하였다. 환자들을 간경변 집단과 비(非)간경변 집단으로 분류했다. PACS를 이용, 각 환자의 SPIO-enhanced MRI에서 RNHFI (간실질 신호강도 표준편차의 평균(SD), 잡음교정 변이계수(CV))를 산출했고, 각 환자의 실험실 검사 결과를 이용, APRI를 산출했다. Student's t-test를 이용하여 두 집단간의 RNHFI와 APRI의 차이를 비교했다. 각 집단에서, RNHFI와 APRI간의 이변량 상관분석을 시행했다. 결과: 간경변 집단에서, SD, CV의 평균은 각각 $10.3{\pm}3.7$, $0.19{\pm}0.08$였다. 비간경변 집단에서, SD, CV의 평균은 각각 $6.5{\pm}1.6$, $0.08{\pm}0.05$였다. 두 집단의 평균 APRI는 각각 $2.04{\pm}1.7$, $0.32{\pm}0.32$였다. RNHFI와 APRI는 두 집단 사이에서 의미 있는 차이를 보였다 (p<0.05). 간경변 집단에서, SD와 APRI는 양의 상관관계를 보였다 (r=0.5, p<0.001). 결론: SD값이 간섬유화의 간단하고 유용한 예측 인자가 될 수 있을 것으로 기대된다.

  • PDF

한국인 조현병 환자에서CNR1 유전자의 (AAT)n 삼핵산 반복 다형성과 안구추적운동 이상에 대한 연합 연구 (No Association between (AAT)n Repeat Polymorphisms in the Cannabinoid Receptor 1 Gene and Smooth Pursuit Eye Movement Abnormality in Korean Patients with Schizophrenia)

  • 김민재;김채리;박진완;백두현;신형두;최인근;한상우;황재욱;이연정;우성일
    • 생물정신의학
    • /
    • 제23권4호
    • /
    • pp.148-156
    • /
    • 2016
  • Objectives According to previous studies, the cannabinoid receptor 1 (CNR1) gene could be an important candidate gene for schizophrenia. Some studies have linked the (AAT)n trinucleotide repeat polymorphism in CNR1 gene with the risk of schizophrenia. Meanwhile, smooth pursuit eye movement (SPEM) has been regarded as one of the most consistent endophenotypes of schizophrenia. In this study, we investigated the association between the (AAT)n trinucleotide repeats in CNR1 gene and SPEM abnormality in Korean patients with schizophrenia. Methods We measured SPEM function in 167 Korean patients with schizophrenia (84 male, 83 female) and they were divided according to SPEM function into two groups, good and poor SPEM function groups. We also investigated allele frequencies of (AAT)n repeat polymorphisms on CNR1 gene in each group. A logistic regression analysis was performed to find the association between SPEM abnormality and the number of (AAT)n trinucleotide repeats. Results The natural logarithm value of signal/noise ratio (Ln S/N ratio) of the good SPEM function group was $4.34{\pm}0.29$ and that of the poor SPEM function group was $3.21{\pm}0.70$. In total, 7 types of trinucleotide repeats were identified, each containing 7, 10, 11, 12, 13, 14, and 15 repeats, respectively. In the patients with $(AAT)7$ allele, the distributions of the good and poor SPEM function groups were 18 (11.1%) and 19 (11.0%) respectively. In the patients with $(AAT)_{10}$ allele, $(AAT)_{11}$ allele, $(AAT)_{12}$ allele, $(AAT)_{13}$ allele, $(AAT)_{14}$ allele and $(AAT)_{15}$ allele, the distributions of good and poor SPEM function groups were 13 (8.0%) and 12 (7.0%), 4 (2.5%) and 6 (3.5%), 31 (19.8%) and 35 (20.3%), 51 (31.5%) and 51 (29.7%), 36 (22.2%) and 45 (26.2%), 9 (5.6%) and 4 (2.3%) respectively. As the number of (AAT) n repeat increased, there was no aggravation of abnormality of SPEM function. Conclusions There was no significant aggravation of SPEM abnormality along with the increase of number of (AAT)n trinucleotide repeats in the CNR1 gene in Korean patients with schizophrenia.

Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method (The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method)

  • 최종숙;정우영;류재광
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.102-109
    • /
    • 2009
  • 목적 : Siemens사의 Flash 3D(Pixon(R) method, 3D OSEM)는 검사 시간을 단축하면서 재구성을 통해 영상의 질을 높일 수 있도록 개발된 소프트웨어 프로그램으로써 핵의학 단층 촬영 시 유용하게 적용되고 있는 영상처리기법이다. 그러나 감산된 영상을 Flash 3D로 재구성하여 시행하는 뇌 혈류 부하 검사 시에 영상 획득시간을 짧게 하여 검사를 시행하면 재구성된 감산 영상의 신호 대 잡음비가(SNR, signal to noise ratio) 기저 영상에 비해 낮아지는 문제점이 있었다. 감산 영상의 SNR을 높이기 위해 LEAP 검출기를 사용하였고, 뇌혈관의 해상력보다는 혈관 확장의 예민도에 더 중점을 두었다. 본 실험은 뇌혈관 부하 단층 촬영 시 LEAP 검출기의 적용 가능성을 확인하고, Flash 3D를 이용한 적정 수준의 재구성 매개 변수를 파악하는 데 목적이 있다. 실험재료 및 방법 : (1) 팬텀 평가: $^{99m}Tc$을 넣은 Hoffman 3D Brain $Phantom^{TM}$을 이용하였다. LEAP와 LEHR 검출기로 첫 번째 영상을(부하 영상에 해당) 획득하고 $^{99m}Tc$의 반감기인 6시간 후 동일한 방법으로 두 번째 영상을(기저 영상에 해당) 획득하였다. 또한, 각각의 기저 영상과 감산 영상의 SNR 및 백질과 회백질의 비를 측정하였다. (2) 환자 영상의 평가: 2008년 5월부터 2009년 1월까지 LEAP 검출기로 촬영하여 정상으로 판독된 15명과 LEHR 검출기로 촬영하여 정상으로 판독된 13명의 환자를 대상으로 영상을 정성분석 하였다. Phantom에서 얻은 재구성 매개 변수를 대입하여 평가하였다. 하루 검사 프로토콜로 시행하였으며 기저에서 925 MBq, 부하에서 925 MBq의 $^{99m}Tc$-ECD를 투여하였다. 결과 : (1) 팬텀 평가: 각 검출기에서 획득한 계수치를 측정한 결과 LEHR 기저에서는 41~46 kcount, 부하에서 79~90 kcount, 감산에서 40~47 kcount가 측정되었다. LEAP의 경우 기저에서 102~113 kcount, 부하에서 188~210 kcount, 감산에서 94~103 kcount가 측정되었다. LEHR 감산 영상의 SNR은 LEHR 기저 영상과 비교하면 37% 감소하여 나타났고, LEAP 감산 영상의 SNR은 LEAP 기저 영상과 비교하면 17% 감소하여 나타났다. 회백질과 백질의 비는 LEHR 기저에서 2.2:1 감산에서 1.9:1로 측정되었고, LEAP 기저에서는 2.4:1 감산에서 2:1로 측정되었다. (2) 환자 영상의 평가: LEHR 검출기로 획득한 계수는 기저에서 대략 40~60 kcount, 부하에서 80~100 kcount 사이였다. 기저 및 부하 영상은 FWHM을 7 mm로 (타 장비의 Cutoff에 해당), 감산 영상은 FWHM을 11 mm로 설정하는 것이 적절하였다. LEAP는 기저에서 대략 80~100 kcount, 부하에서 180~200 kcount로 측정되었다. LEAP 영상은 기저 및 부하에서 FWHM을 5 mm로, 감산에서 7 mm로 설정해야 영상의 흐림을 줄일 수 있었다. 기저 및 부하 영상은 LEHR 영상이 LEAP 영상보다 해상력이 우수했다. 그러나 감산 영상의 경우 팬텀 실험과 같이 LEHR 영상의 SNR이 떨어져 영상이 거칠게 보였다. 감산 영상은 LEAP 영상이 LEHR 영상에 비해 SNR 및 예민도가 높게 평가되었다. LEHR과 LEAP 검출기의 모든 영상에서 subset과 iteration은 8회가 적절하였다. 결론 : LEAP 검출기를 이용해 적정 수준의 필터를 사용함으로써 SNR을 높여 보다 선명한 감산 영상을 획득할 수 있게 되었다. 하루 검사 프로토콜을 적용하여 Flash 3D로 재구성하는 경우, 보다 나은 감산 영상을 얻기 위해 LEAP 검출기의 적용을 고려해 볼 수 있을 것으로 판단된다.

  • PDF

하저 지반특성 규명을 위한 전기비저항 탐사 (DC Resistivity method to image the underground structure beneath river or lake bottom)

  • 김정호;이명종;송윤호;조성준;이성곤;손정술
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2002년도 정기총회 및 제4회 특별심포지움
    • /
    • pp.139-162
    • /
    • 2002
  • 수로는 약선대를 따라 형성되는 경우가 많으며, 특히 강을 따라 단층이 발달하는 경우가 많다. 교량과 같은 수상 구조물의 건설을 위하여 탐사의 필요성이 많았음에도 불구하고 육상과는 달리 수상 전기비저항 탐사가 활발하게 적용되지 못한 것은 현장탐사와 해석의 어려움 때문이었다고 볼 수 있다. 그러나 무엇보다도 중요한 것은 양질의 자료 획득이며, 양질의 자료 획득이 육상탐사보다 어려운 것은 영상화하고자 하는 지하구조가 물로 덮여 있다는 점에서 연유한다. 이 연구에서는 이와 같은 점에 중점을 두고 수치 모델링과 현장탐사 사례 분석을 통하여 수상 전기비저항 탐사 자료의 특성, 현장 탐사와 해석 방법에 대하여 논하였다. 수상 전기비저항 탐사는 전극이 물 표면에 혹은 물 바닥에 설치되어 있는가에 따라 탐사자료의 획득방법, 고려사항, 해석 방법이 달라지므로, 전극을 물 표면에 띄운 경우와 바닥에 설치한 경우로 나누어 논의를 전개하였다. 이를 통하여 하상 전기비저항 탐사는 수 층 하부 지반을 정확하게 영상화할 수 있음을 보였다. 또한 수상 전기비저항 탐사에서 전극을 물 바닥에 설치하는 것이 물 표면에 설치하는 것보다 훨씬 더 분해능이 높은 영상을 획득할 수 있으나, 육상탐사에 비하여 지하구조에 대한 민감도는 훨씬 낮고, 유동전위 등에 의하여 전기잡음이 높을 가능성이 높기 때문에 육상탐사보다 훨씬 높은 S/N 비를 갖는 현장 탐사자료의 획득이 필수적이며 가능한 한 높은 분해능을 갖는 전극배열을 선택하여야 하는 것으로 나타났다 전극을 물 바닥에 설치하는 방법은 고분해능 영상을 제공할 수 있기 때문에 지하의 정밀 영상을 획득하기 위한 정밀탐사에 적합하다. 이에 반해 물 표면에 전극을 띄워서 자료를 획득하는 방법은, 특히 이동하면 연속적으로 탐사하는 스트리머 전기비저항 탐사는 매우 빠른 시간에 넓은 지역을 탐사할 수 있기 때문에 개략탐사에 많은 활용이 기대된다.향상을 위해 좀더 적극적인 치료가 필요하다.과 TIMP-2의 발현의 정도는 차이가 있었으며, 각 장기의 특정한 세포에서만 발현이 되었다. TIMP-1의 경우 간과 신장에서는 방사선에 의해 발현이 증가되었으나 폐에서는 발현이 증가되지 않았다. TIMP-2의 경우 폐에서는 방사선에 의해 발현이 증가하였으나 간과 폐에서는 방사선에 의한 발현의 변화는 불규칙적이었다. 방사선 조사 후 경과 시간과 방사선량에 따른 발현의 변화도 일정하지 않았다.EX> 발현의 감소가 관찰되어, Captopril이 조기 폐손상을 억제하는 방사선보호제로서 기전의 일부에 $TNF\alpha$$TGF\beta1$이 관여함을 확인할 수 있었다.주의 정책으로 우리 민족의 정서와 문화를 보존하는 일에 등한시하여 왔다. 이 때문에 우리 민족 고유의 뿌리를 점차 잃어가고 있다. 이러한 시점에서 도시노점상을 정리하기 위한 목적으로 정부에서 도시 5일장을 개장한 것은 역사의 아이러니라 아니할 수 없다. 이렇게 정부주도로 개장된 5일장이 운영되어 온 지 2년이 되어가고 있다. 개장 초기에는 시에서의 지원도 적극적이고 소비자들의 호응도 좋았으나, 최근에 들어 활성화의 속도가 둔화되면서 도시 5일장의 개념을 재정립할 필요성이 제기되고 있다. 정부의 주도로 시작된 5일장이므로 정부의 적극적인 추진하에 풍물시장 번영회와 활성화 방안을 모색해야 한다. 쌍다리 풍물시장의 5일장을 활성화하기 위하여 도시 5일장의 개념을 ${\ulcorner}$국민들의 생활수준이 향상되고 여가를 즐길 수 있는 여건이 형성되고 있으므로 전통문화(향토문화)를 유지하고 시민들의 정서함양에 기여할 수 있는 여가공간 조성${\lrcorner}$으로 규정해야 한다. 이러한 개념 하에 5일장의 주체를 명확히 하기 위해 시청 지역경제과를 중심으로 지자제의 실시에

  • PDF

6 MV 광자빔에 대한 MicroLion 액체이온함의 특성 연구 (A Study of Characteristics of MicroLion Liquid Ionization Chamber for 6 MV Photon Beam)

  • 최상현;허현도;김성훈;지영훈;김금배;김우철;김헌정;신동오;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.216-223
    • /
    • 2011
  • 최근 PTW사에서는 물등가물질로 구성되어 있고, 측정체적(sensitive volume, $0.002cm^3$)이 매우 작은 MicroLion 액체이온함을 내놓았다. 본 연구의 목적은 외부방사선 치료용 광자빔에 대해 MicroLion 액체이온함의 선량선형성, 선량률의존성, 공간분해능, 그리고 출력인수와 같은 선량측정학적 특성을 조사하는 것이다. 이 결과를 Semiflex 이온함($0.125cm^3$), Pinpoint 이온함($0.015cm^3$), 다이오드 검출기($0.0025mm^3$)의 결과와 비교분석하여 소조사면 측정에 적절한지를 평가하고 자 하였다. Varian clinac 2300 C/D의 6 MV 광자빔에서 측정하였으며, MP3 물팬톰(PTW, Freiburg)을 이용하였다. 공간분해능은 반음영(penumbra)을 측정하여 평가하였으며, $0.5{\times}0.5cm^2$에서 $10{\times}10cm^2$까지 다양한 조사면에 대하여 측정하였다. 출력인수는 $0.5{\times}0.5cm^2$에서 $40{\times}40cm^2$에 대하여 측정하였다. 선량에 따른 MicroLion 액체이온함의 측정값은 선형적인 비례성을 보였다. 그러나 선량률은 100 MU/min와 600 MU/min에 의한 측정값의 차이가 최대 5%의 차이를 보였으며, 선량율이 커질수록 출력선량이 작아지는 결과를 보였다. 공간분해능의 경우 조사면 $0.5{\times}0.5cm^2$에서 $10{\times}10cm^2$까지의 측방선량분포 비교에서 Semiflex 이온함을 제외한 다른 모든 검출기들의 경우 2% 이내에서 일치하였다. 출력선량은 $2{\times}2cm^2$에서 $10{\times}10cm^2$ 조사면에서 Semiflex 검출기 대비 모든 검출기가 2% 이내에서 잘 일치하였다. 연구 결과 MicroLion 액체이온함은 물등가물질로 이루어져 있으며, 감응 면적이 매우 작기 때문에 소조사면에서 매우 유용할 것으로 사료된다.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • 윤원섭;이상우
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

움직임 벡터의 시공간 상관성을 이용한 새로운 고속 블럭 정합 움직임 추정 방식 (New Fast Block-Matching Motion Estimation using Temporal and Spatial Correlation of Motion Vectors)

  • 남재열;서재수;곽진석;이명호;송근원
    • 방송공학회논문지
    • /
    • 제5권2호
    • /
    • pp.247-259
    • /
    • 2000
  • 본 논문은 움직임 벡터의 높은 시$\cdot$공간 상관도 정보를 이용하여 계산량을 줄이면서 움직임 추정의 정확도를 높일 수 있는 새로운 블럭 정합 움직임 추정 방식을 제안한다. 제안된 방식은 기존의 고속 움직임 추정 방식들이 이용하는 탐색 영역내의 일관된 첫 번째 탐색 위치에서 움직임 벡터를 찾는 것이 아니라 움직임 벡터의 높은 시$\cdot$공간 상관도 정보를 이용하여 보다 정확한 탐색영역을 찾아 탐색 영역을 보정함으로써 보다 정확한 첫번째 탐색 위치를 중심으로 움직임 벡터를 탐색한다. 즉, 본 논문에서 제안하는 방식의 핵심은 움직임 추정의 정확도를 높이기 위해서 보다 정확한 첫번째 탐색 위치를 찾는 것이다. 따라서 움직임 벡터의 시간적인 상관성을 이용하기 위해서 현재 프레임 블럭과 같은 좌표를 갖는 이전 프레임 블럭의 방향성을 조사한다. 또한 공간적인 상관성을 이용하기 위해서 현재 프레임내의 이웃 블럭들의 방향성을 조사한다. 이러한 블럭들이 갖는 방향성을 바탕으로 움직임 추정을 위한 첫번째 탐색 위치를 결정하게 되고 그 위치를 중심으로 일정한 탐색 패턴에 따라 움직임 벡터를 탐색하는 방식이다. 실험 결과 제안된 방식은 기존의 대표적인 고속 탐색 방식들에 비해 PSNR (Peak-to-Signal Noise Ratio) 값에 있어서 평균적으로 1.7dB 개선되고 영상에 따라 최고 3.6dB 정도 우수한 결과를 나타낸다. 또한 탐색 횟수에서는 기존의 대표적인 고속탐색 알고리즘인 3단계 탐색 알고리즘 (Three-step search algorithm) 보다 평균 50% 이상을 줄일 수 있었고, 정확한 움직임 벡터를 찾는 비교에 있어서도 월등히 우수한 결과를 나타내었다. 또한 제안된 방식은 정량적인 결과뿐만 아니라 부호화 후 복호화한 영상의 화질에 있어서도 다른 고속 탐색 알고리즘 보다 월등히 우수한 화질을 제공한다. 및 상품과율 등이 모두 10:0 양액보다 높게 나타났다. 식물체내의 무기성분은 8:2의 경우 K+ 및 Mg2+는 잎에서 Ca2+은 뿌리에서 많았으며 PO4-은 과실과 줄기에서 많았다. 10:0에서의 무기성분도 8:2에서와 같은 경향을 나타내었으며, 배지간에 무기성분의 차이는 인정되지 않았다. 양액조성에 따른 무기성분 함량의 차이는 K+, Ca2+ 및 Mg2+는 10:0에서, PO4-은 8:2에서 각각 많았다.uage. The major language of calligraphy pattern was Arabic script and often Persian script. Calligraphy pattern was composed of Kufic and Cursive script. The cursive script was developed various forms. The Islamic tenet prohibit depiction of sacred images, the sacred Arabic calligraphy such as ′Alla′ or ′Mohammad′ was substituted of them. And the content of calligraphy pattern was used with Quranic phrases. The aesthetics of Islamic patterns analyzed aesthetic of ′rhythmic lines′, aesthetic of ′unity in multiplicity′, aesthetic of tessellation and aesthetic of harmony. On the textiles of the Islamic culture, the arabesque, floral, geometric and calligraphy patterns were frequently used.의 증가를 나타냈다.". And the

  • PDF

1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성 (The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT)

  • 최진욱;김수미;이형진;김진의;김현주;이재성;이동수
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.94-100
    • /
    • 2011
  • 1-day protocol method는 DIAMOX 영상에서 basal 영상을 감산시키는 방법으로 혈관 예비능을 평가하는데 있어서 매우 유용한 검사지만, 검사시간이 길기 때문에 움직임에 의한 불가피한 재검사율이 높다. 기하학적으로 차이가 있는 fan-beam 콜리메이터와 parallel 콜리메이터 중 임상적으로 1-day protocol method에 가장 효율적인 콜리메이터가 무엇인지 알아보았다. 삼중 헤드 감마카메라인 triad XLT 9 (TRIONIX)와 세 가지 콜리메이터(low energy high resolution-parallel beam: LEHR-par, ultra resolution-fan beam: LEUR-fan, super fine-fan beam: LESR-fan)를 사용하였다. PET/SPECT performance phantom, Hoffman 3D phantom, volunteer 실험을 실시하여 세 가지 콜리메이터의 감도, 대조도, 해상력, 영상의 질을 비교 측정하였다. Pixel size를 fan-beam 콜리메이터와 동일하게 하기 위하여 parallel 콜리메이터 실험 시 zoom factor를 2.0으로 변경하였다. Scan time은 50 kcounts/frame을 만족하게 하였으며 filtered back projection (FBP)의 재구성 방법을 사용하였고 각 콜리메이터 별 최적의 영상을 위하여 cut off 값을 변화하면서 비교 측정하였다. 총 획득 계수가 동일한 조건에서 해상력과 percent background variability는 LESR과 LEUR이 LEHR보다 우수한 결과를 나타내었고, 영상의 육안평가에서 선호도는 LESR, LEUR, LEHR 순이었다. 영상 획득 시간은 LESR이 낮은 감도로 인하여 LEUR과 LEHR보다 약 2배 더 길게 소요됐다. Volunteer 실험의 결과 LESR을 사용할 때보다 LEUR 또는 LEHR을 사용 할 때 약 10-14분 정도 시간이 감소했다. 1-day protocol method는 단 한 번의 움직임에도 재검사가 불가피하기 때문에 적절한 분해능뿐만 아니라 높은 감도의 유지를 위해 적절한 검사 방법의 확립이 중요하다 할 수 있다. 본 연구에서 동일한 계수를 획득할 경우 LEUR은 LESR보다 2배의 시간을 감소시킬 수 있었고 영상의 육안평가나 해상력도 LESR과 임상적으로 큰 차이를 보이지 않았으므로 Brain SPECT의 1-day protocol method에 가장 적합할 것으로 사료된다.

  • PDF

알렌 마우스 브레인 아틀라스를 이용한 반자동 신경섬유지도 분석 : 여기수와 신호대잡음비간의 DTI 획득 비교 (Semi-automated Tractography Analysis using a Allen Mouse Brain Atlas : Comparing DTI Acquisition between NEX and SNR)

  • 임상진;백현만
    • 한국방사선학회논문지
    • /
    • 제14권2호
    • /
    • pp.157-168
    • /
    • 2020
  • 자기공명영상(Magnetic Resonance Image)을 이용한 구조적 연구 방법에서 뇌 구조 세분화 방법은 최근 빠르게 발전하여 구조 이미지의 자동 분할을 위한 유능한 방법론이 되었다. 특히 아틀라스 정보를 이미지에 등록해 피사체의 이미지로 전달하는 분할(Segmentation) 방법은 아틀라스(Atlas)의 정확도에 편향되기 때문에 높은 정확도를 갖고 있는 아틀라스가 필요하게 된다. 알렌 마우스 뇌 아틀라스(Allen Mouse Brain Atlas)는 마우스의 아틀라스 중에서 높은 정확도를 갖고 있어 다양한 분야에서 사용되고 있으며, 신경섬유지도(Tractography)에 필수적인 마우스 뇌구조의 정확한 좌표와 분할 정보를 제공할 수 있다. 또한 기능적 연구 방법인 뇌의 백질 경로를 재구성하는 확산텐서영상(Diffusion Tensor Image)에 대한 확률론적 신경섬유지도를 사용하여 포괄적인 뉴런 네트워크를 매핑 하였다. 인간의 뇌 연구 결과와 마우스의 뇌 연구 결과는 비교분석 할 수 있어 인간에게 적용하기 어려운 실험들을 질환이 모델링된 마우스를 통해 결과를 얻어 임상적으로 이용이 가능하기 때문에 마우스 실험의 중요성이 올라가고 있다. 하지만 마우스를 이용한 연구에서 인간과 마우스의 뇌 크기 차이로 인한 문제가 있어 동등한 영상의 질을 달성하려면 다양한 조건이 필요하게 되며, 그중 대표적으로 충분히 긴 스캔시간이 필요하게 된다. 충분히 긴 스캔시간을 확보하기 위해 본 연구에서는 마우스의 뇌를 샘플화시켜 Ex-vivo 실험이 진행되었으며, 마우스 커넥톰(Connectome) 매핑에 대한 참조를 제공하기 위해 이 연구는 아틀라스 정규화 도구인 ANTx와 확산 텐서 영상을 분석할 도구인 FSL을 사용하여 마우스 뇌의 반자동 분할 및 신경섬유지도 분석 파이프라인을 제시하여 다양한 마우스 모델에 적용하고자 했다. 또한, 신경섬유지도 분석을 위해 획득하는 확산텐서영상의 유용한 신호대 잡음비를 결정하기 위해 다양한 여기수의 영상을 획득해 비교분석하였다.

중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구 (A Study of Optimized MRI Parameters for Polymer Gel Dosimetry)

  • 조삼주;정영립;이상훈;허현도;최진호;박성일;심수정;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.71-80
    • /
    • 2012
  • 최신 방사선 치료 및 수술 기법에는 복잡한 3차원적 선량분포를 정확히 측정하는 실용적 선량분석 기기 및 기술이 필요하다. 본 연구에서는 실험실에서 제작한 겔을 방사선 치료 영역에서 선량계로 활용하기 위해 최적화된 자기공명영상 변수 조건에 대해 연구하였다. 이를 위해 각 자기공명영상 획득 조건에서 TE 시간 TR 시간, 영상 두께, 코일 등을 달리하여 조건 별로 획득한 영상을 이용하여 비교 평가하였고, 선량불확도 및 선량 분해능을 도입하여 본 연구에서 찾은 조건에 대해 평가하였다. 8% 젤라틴(300 bloom, Sigma-Aldrich, USA), 8% MAA (Metaacrylic acid, Sigma-Aldrich, USA), 10 mM THPC (tetrakis hydroxymethyl phosphonium, Sigma-Aldrich, USA), 그리고 0.05 mM HQ (Hydroquinone, Sigma-Aldrich, USA) 농도의 조성비를 가진 정상산소 중합체 겔을 실험실에서 합성하였다. 방사선 선량 전달은 Co-60 감마선 조사기 (Theratron-780; AECL, Ottawa, Canada)를 사용하였고 고체 팬텀을 사용하여 중합체 겔에 각각 0, 2, 4, 6, 8, 10, 12, 14 Gy의 선량을 전달하였다. 자기공명영상 장치의 특성상 T2 시간을 얻기 위해서는 fast spin echo 파형을 사용하였다. 일반적으로 Head Coil이 SNR이 Body coil 보다 낮아 선량 불확도가 우수할 것으로 예측하였으나, 일부 문헌에서는 Body coil이 영상 균일도가 우수하다고 하였다. 하지만 본 연구에서는 Head coil이 선량 불확도 및 선량 분해능이 모든 선량 영역에서 Body coil 보다 우수한 것을 확인하였다. TR 시간 연구에서 TR 1,500 ms와 TR 2,000 ms 간의 차이는 선량분해능에서 모두 큰 차이가 없으나 TR 1,500 ms가 조금 낮은 선량 불확도 값을 갖는 것을 보았다. MR 영상 두께가 2.5 mm일 경우 모든 TE 시간에 대해 4 Gy에서 가장 낮은 선량 불확도 값을 가졌다. 특히 TE 12 ms 경우 4 Gy 이후에는 가장 낮은값의 결과를 얻었다. 선량 불확도의 경우 6 Gy까지는 TE 시간에 따른 차이는 없으나 이후에는 TE 12 ms가 가장 나은 결과를 얻었다. 선량 불확도의 겨우 6 Gy까지는 모든 TE 시간에 대해 차이가 미미하나 8 Gy 이상에는 20 ms가 가장 우수한 선량 분해능 값을 가졌다. 선량 분해능 값 역시 NEX 3에서 가장 우수한 값을 가졌고 2 NEX일 때 가장 높은 분해능 값을 가졌다. 본 연구 결과 영상 두께와 NEX의 결과는 영상 두께가 얇은 경우 NEX가 높을수록 우수한 결과를 얻었고 영상 두께가 두꺼워 질수록 NEX가 낮아야 함을 확인했다.