• Title/Summary/Keyword: Signal to Noise Ratio(SNR)

Search Result 1,129, Processing Time 0.029 seconds

BER Performance Analysis for Adaptive Cooperation Scheme with Decode-and-Forward Relay-Selection (복호 후 전달 릴레이 선택을 이용한 적응형 협력 기법의 BER 성능분석)

  • Vu, Ha Nguyen;Kong, Hyung-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11A
    • /
    • pp.831-843
    • /
    • 2009
  • In this paper, we propose a new adaptive cooperation scheme with multi-relay nodes which achieves higher performance and spectral efficiency than that of some conventional cooperative schemes. The relay-selection is applied to choose the most potential relay among K ones. Afterward, the instantaneous signal-to-noise ratio (SNR) differences between S-D, S-R and R-D channels are considered for adaptive selection between the direct and the cooperation transmission strategy. In the proposed adaptive protocol, if the direct link is of high quality, the source will transmit to destination directly with all power consumption. Otherwise, the source broadcasts the signal with a lower power and requires the help of the chosen relay if it decodes correctly, else the source will transmit again with remaining power. Firstly, the spectral efficiency is derived by calculating the probability of each mode. Subsequently, the BER performance for the adaptive cooperation scheme is analyzed by considering each event that one of K relays is selected and then making the summation of all. Finally, the numerical results are presented to confirm the performance enhancement offered by the proposed schemes.

Performance Analysis of Frame Synchronization and Structure Detection Utilizing Multiple Frames of the DVB-S2 Satellite Broadcasting System (다수개 프레임을 활용한 DVB-S2 위성방송 시스템의 프레임 동기 및 구조 검출 성능 분석)

  • Kim, Sang-Tae;Kang, Seok-Heon;Sung, Won-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2A
    • /
    • pp.139-147
    • /
    • 2008
  • DVB-S2 (Digital Video Broadcasting-Satellite, Version 2) system transmits frames which adapt their structures based on the channel conditions, thus requiring simultaneous detection of the start of the Same (SoF) and the frame structure at the initial acquisition stage of the receiver. Also, a very low value of the minimum operating signal-to-noise ratio (SNR) for the acquisition necessitates a method utilizing multiple received frames to meet the required performance. In this paper, performance of joint time synchronization and frame structure detection methods using multiple DVB-S2 frames is evaluated by deriving the detection error probability. In particular, we evaluate the performance and complexity variations when the soft- and hard-decision values of the signal correlation output are used, present the synchronization parameters to optimize the performance, and verify the analysis results via computer simulations.

AT-DMB Reception Method with Eigen-space Beamforming Algorithm (고유 공간 빔형성 알고리즘을 이용한 AT-DMB 수신 방법)

  • Lee, Jae-Hong;Choi, Seung-Won
    • Journal of Broadcast Engineering
    • /
    • v.15 no.1
    • /
    • pp.122-132
    • /
    • 2010
  • AT-DMB system has been developed to increase data rate up to double of conventional T-DMB in the same bandwidth while maintaining backward compatibility. The AT-DMB system adopted hierarchical modulation which adds BPSK or QPSK signal as enhancement layer to existing DQPSK signal. The enhancement layer signal should be small enough to maintain backward compatibility and to minimize the coverage loss of conventional T-DMB service coverage. But this causes the enhancement layer signal of AT-DMB susceptible to fading effect in transmission channel. A turbo code which has improved error correction capability than convolutional code, is applied to the enhancement layer signal of the AT-DMB system for compensating channel distortion. However there is a need for other solutions for better reception of AT-DMB signal in receiver side without increasing transmitting power. In this paper, we propose adaptive array antenna system with Eigen-space beamforming algorithm which benefits beamforming gain along with diversity gain. We analyzed the reception performances of AT-DMB system in indoor and mobile environments when this new smart antenna system and algorithm is introduced. The computer simulation results are presented along with analysis comments.

Comparison of ICA Methods for the Recognition of Corrupted Korean Speech (잡음 섞인 한국어 인식을 위한 ICA 비교 연구)

  • Kim, Seon-Il
    • 전자공학회논문지 IE
    • /
    • v.45 no.3
    • /
    • pp.20-26
    • /
    • 2008
  • Two independent component analysis(ICA) algorithms were applied for the recognition of speech signals corrupted by a car engine noise. Speech recognition was performed by hidden markov model(HMM) for the estimated signals and recognition rates were compared with those of orginal speech signals which are not corrupted. Two different ICA methods were applied for the estimation of speech signals, one of which is FastICA algorithm that maximizes negentropy, the other is information-maximization approach that maximizes the mutual information between inputs and outputs to give maximum independence among outputs. Word recognition rate for the Korean news sentences spoken by a male anchor is 87.85%, while there is 1.65% drop of performance on the average for the estimated speech signals by FastICA and 2.02% by information-maximization for the various signal to noise ratio(SNR). There is little difference between the methods.

A Beamforming Method for a Perturbed Linear Towed Array (비선형 형상 견인 어레이를 위한 빔형성 기법)

  • 김승일;도경철;오원천;윤대희;이충용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.478-484
    • /
    • 2002
  • Linear towed arrays (LTA) have a nonlinear shape due to tow vessel motion, ocean swells and currents. By reasons of nominally linear shape, various towed array shape estimation techniques have been developed since the perturbed shape cause the error in target detection. In this paper,, we propose the beamforming method for the perturbed LTA with simple structure. The proposed method linearizes a nonlinear phase of steering vector with position information measured by two reference sensors. It can be proved using some properties of Markov transition matrix, and iteration number of linearization process is decided by variance of cross phase difference. As a result of computer simulation in the ocean environment, beampattern of the proposed method is almost same with the ideal case in my type of array shape. In the signal-to-noise ratio (SNR) performance simlation, the DOA estimation performance of the proposed beamforming method is evaluated, and the comparison with Bartlett beamformer of the LTA shows that the proposed method can estimate. the spatial characteristic of sources more accuracy.

An Exact BER Analysis of Dual-Hop MIMO Decouple-and-Forward Relaying with Orthogonal Space-Time Block Codes (직교 시공간 블록 부호를 적용한 듀얼 홉 MIMO Decouple-and-Forward 릴레이에 대한 정확한 비트 에러율 분석)

  • Lee, Jae-Hoon;Kim, Dong-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12A
    • /
    • pp.1147-1155
    • /
    • 2008
  • In this paper, we derive the probability density function (PDF) of end-to-end signal-to-noise ratio (SNR) for t he dual-hop MIMO (Multiple-Input Multiple-Output) DCF (Decouple-and-Forward) system. We also provide the end-to-end bit error ratio (BER) with M-ary PSK constellations for four antenna combinations. These are (1,8,1), (8,1,8), (2,4,2), and (4,2,4). Each number in the parentheses is the number of the transmit antenna at the source, the transmit and receive antenna at the relay and the receive antenna at the destination, respectively. We show t hat the end-to-end BER expression with M-ary PSK constellations makes an exact match with numerical results. We also show that MIMO DCF relay system achieves spatial diversity.

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.

Gadolinium Complexes of Bifunctional Diethylenetriaminepentaacetic Acid (DTPA)-bis(amides) as Copper Responsive Smart Magnetic Resonance Imaging Contrast Agents (MRI CAs)

  • Nam, Ki Soo;Park, Ji-Ae;Jung, Ki-Hye;Chang, Yongmin;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.2900-2904
    • /
    • 2013
  • We present the synthesis and characterization of DTPA-bis(histidylamide) (1a), DTPA-bis(aspartamide) (1b), and their gadolinium complexes of the type $[Gd(L)(H_2O)]$ (2a:L = 1a; 2b:L = 1b). Thermodynamic stabilities and $R_1$ relaxivities of 2a-b compare well with Omniscan$^{(R)}$, a well-known commercial, extracellular (ECF) MRI CA which adopts the DTPA-bis(amide) framework for the chelate: $R_1$ = 5.5 and 5.1 $mM^{-1}$ for 2a and 2b, respectively. Addition of the Cu(II) ion to a solution containing 2b triggers relaxivity enhancement to raise $R_1$ as high as 15.3 $mM^{-1}$, which corresponds to a 300% enhancement. Such an increase levels off at the concentration beyond two equiv. of Cu(II), suggesting the formation of a trimetallic ($Gd/Cu_2$) complex in situ. Such a relaxivity increase is almost negligible with Zn(II) and other endogenous ions such as Na(I), K(I), Mg(II), and Ca(II). In vivo MR images and the signal-to-noise ratio (SNR) obtained with an aqueous mixture of 2b and Cu(II) ion in an 1:2 ratio demonstrate the potentiality of 2 as a copper responsive MRI CA.

LFM Radar Implemented in SDR Architecture (SDR 기반의 LFM 레이다 설계 및 구현)

  • Yoon, Jae-Hyuk;Yoo, Seung-Oh;Lee, Dong-Ju;Ye, Sung-Hyuck
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.308-315
    • /
    • 2018
  • In this paper, we present the basic design results for high-resolution radar development at S-band frequency that can precisely measure the miss distance between two targets. The basic system requirement is proposed for the design of a 3.5 GHz linear frequency-modulated (LFM) radar with maximum detection distance and distance resolution of 2 km and 1 m, respectively, and the specifications of each module are determined using the radar equation. Our calculations revealed a signal-to-noise ratio ${\geq}30dB$ with a bandwidth of 150 MHz, transmission power of 43 dBm for the power amplifier, gain of 26 dBi for the antenna, noise figure of 8 dB, and radar cross-section of $1m^2$ at a target distance of 2 km from the radar. Based on the calculation results and the theory and method of LFM radar design, the hardware was designed using software defined radar technology. The results of the subsequent field test are presented that prove that the designed radar system satisfies the requirements.

Design and Performance Analysis of Current Source for 3.0T MREIT System (3.0T MREIT 시스템을 위한 정전류원의 설계 및 성능검증)

  • 김규식;오동인;백상민;오석훈;우응제;이수열;이정한
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.165-169
    • /
    • 2004
  • In Magnetic Resonance Electrical Impedance Tomography (MREIT), we inject current through electrodes placed on the surface of a subject and measure the induced magnetic flux density distribution using an MRI scanner. This requires a constant current source whose output pulses are synchronized with MR pulse sequences. In this paper, we present a design and performance analysis of a current source used in a 3.0T MREIT system. The developed current source was tested using a saline phantom. We found that its performance is satisfactory for the current MREIT system. We suggest future improvements for better SNR(signal-to-noise ratio).