발전기 모델링 정도에 의한 고유치 감도계수에 미치는 영향해석 (Analysis of the first order eigenvalue sensitivity affected by generator model)

  • 조언중;이군재;김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.119-121
    • /
    • 2003
  • In small signal stability analysis of power systems, eigenvalue analysis is the most useful method and the detailed modeling of generator gives an important effect to the eigenvalues. Generator full model is used for precise dynamic analysis of generators and controllers while two-axis model is used for multimachine systems because of the reduced order of the state matrix. Also, the eigenvalue sensitivity coefficients are used for optimization of controller parameters to improve system stability. This paper compare the first order eigenvalue sensitivity coefficients of controllers in case of generator full model with those of two-axis model. As a result of an example the estimated eigenvalues using sensitivity coefficients in case of generator full model is very close to those of state matrix within 1% error ratios.

  • PDF

Power System Oscillations Damping Using UPFC Based on an Improved PSO and Genetic Algorithm

  • Babaei, Ebrahim;Bolhasan, Amin Mokari;Sadeghi, Meisam;Khani, Saeid
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권1호
    • /
    • pp.135-142
    • /
    • 2012
  • In this paper, optimal selection of the unified power flow controller (UPFC) damping controller parameters in order to improve the power system dynamic response and its stability based on two modified intelligent algorithms have been proposed. These algorithms are based on a modified intelligent particle swarm optimization (PSO) and continuous genetic algorithm (GA). After extraction of UPFC dynamic model, intelligent PSO and genetic algorithms are used to select the effective feedback signal of the damping controller; then, to compare the performance of the proposed UPFC controller in damping the critical modes of a single-machine infinite-bus (SMIB) power system, the simulation results are presented. The comparison shows the good performance of both presented PSO and genetic algorithms in an optimal selection of UPFC damping controller parameters and damping oscillations.

Low-Band Type 능동형 현가제어를 위한 직동식 전자비례 감압밸브의 개발 (Development of a Direct-Operated Proportional Pressure Reducing Valve for Low-Band Type Active Suspension Control)

  • 홍예선;류시복;김영식
    • 한국자동차공학회논문집
    • /
    • 제2권3호
    • /
    • pp.75-84
    • /
    • 1994
  • In general direct-operated pressure reducing valves have been gardly applied to a dynamic control system such as active suspension control because of their poor control stability. But they are more robust than pilot-operated type and do not need pilot control flow. In this paper development of a new direct-operated proportional pressure reducing valve for low-band type active suspension control is reported. By means of a special damper directly linked to the valve spool, the control stability could be effectively improved without drawback in response time. The linearity error was less than $\pm$3.5%. Applied to an experimental active suspension system the new valve showed the $-90^{\circ}$ phase delay at 4Hz with 20% sinusoidal signal input and could control the suspension system with almost same performance as that with a pilot-operated type valve.

  • PDF

터-빈 발전기의 견실성 제어를 위한$H_\infty$제어 시스템 설계 ($H_\infty$Control Synthesis for Robust Control of a Turbo-Generator)

  • 정대원;김건중
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.622-628
    • /
    • 1999
  • This paper presented to design a robust turbo-generator control system using {{{{ { H}_{$\infty$ } }}}} control synthesis for improving small-signal stability. Application study of{{{{ { H}_{$\infty$ } }}}} control synthesis is more appropriate in this system since a turbo-generator system is usually operated under circumstance of unmeasurable modelling uncertainty and external disturbance. The{{{{ { H}_{$\infty$ } }}}} control theory was briefly reviewed for good understanding and the reasonable approach. The design results are simulated for a case study and to check the system performance in comparison with currently operating Lead/Lag filtered PSS performance.

  • PDF

피드백 요소를 고려한 전류모드 제어기의 안정도해석 (The stability analysis of current mode controller considering feedback element)

  • 김철진;송요창;진용선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.239-241
    • /
    • 2001
  • Recently the power supply equipments have tendency to take multiple feedback loop paths. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$, is nearly 1/5 of switching frequency $f_s$, from the experimental result with frequency response analyzer.

  • PDF

탐색기의 주사루프 모델링과 LQG/LTR보상기 설계 (Modelling and LQG/LTR Compensator Design of the Seeker Scan-Loop)

  • 황홍연;이호평
    • 대한기계학회논문집
    • /
    • 제17권11호
    • /
    • pp.2730-2741
    • /
    • 1993
  • A mathematical model of the seeker scan-loop which is composed of a spin-stabilized gyroscope and its driving signal processors is derived. The derived model has a transmission zero pair on the imaginary axis near to the required bandwidth. The LQG/LTR design methodology is evolved for the derived scan-loop model. To implement the designed LQG/LTR compensator to the actual plant, the compensator order is reduced using the internally balanced realization method. The performances of the LQG/LTR compensator are tested and compared with those of the P-control. Especially, stability-robustnessexperiments for model uncertainties represented in the form of time-delays are performed. It is demonstrated that the LQG/STR compensator is actually very robust to model uncertainties.

최적 변조 제어기를 이용한 교류-직류계통의 안정화에 관한 연구 (A Study for the Stabilization of A.C.-D.C. Power Systems Using Optimal Modulation Controllers)

  • 왕용필;허동렬;정형환;김해재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.123-126
    • /
    • 1996
  • In this paper, optimal modulation controller is designed to improve the stability of A.C. and A.C.-D.C. power system, and optimal theory is applied to select optimal modulation controller input signal Optimal modulation controller for speed governor and exciter controller system is constructed in A.C. power system, while the controller is constructed to the both control systems like AC. power system, considering ACR-AVR, APR-$A{\gamma}R$ as the control method of direct current system. It is considered that the stability of A.C. power system only and A.C.-D.C. power system against load fluctuations and disturbances under case of optimal modulation control.

  • PDF

전류제어형 DC-DC컨버터의 안정도 향상에 관한 연구 (A Study on the stability improvement of current-mode controlled DC-DC Converter)

  • 김철진;송요창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.365-367
    • /
    • 2000
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$ from the experimental result with frequency response analyzer.

  • PDF

Calculation and Comparison of Maximum Lyapunov Exponent in Different Direction: An Approach to human Gait Stability

  • Dinesh, Paudel
    • 한국운동역학회지
    • /
    • 제31권1호
    • /
    • pp.24-29
    • /
    • 2021
  • Objective: The goal of this study is to calculate and compare the Maximum Lyapunov Exponent (MLE) for the anteroposterior, mediolateral and vertical displacement of the markers attached to bony land marks of the trunk and foot. Method: Ten young and healthy male subjects (age: 26.5±3.27 years, height: 167.44±5.12 cm, and weight 69.5±7.36) participated in the study. Three-dimensional positional coordinate of eight different trunk and foot marker during walking on tread mill were analysed. Results: MLE values for anteroposterior displacement of the marker were found to be significantly different with MLE values for mediolateral and vertical displacement whereas MLE values for mediolateral displacement of the marker shows no significant difference with the MLE values for vertical displacement of the markers at significance level 0.05. Conclusion: Finding of this study suggest that it is essential to consider the displacement in all three direction to examine the real characteristic of a gait signal.

수중 음향 채널의 해저 광케이블 간섭 효과 분석 (Interface Effect Analysis between Undersea Fiber Optic Cable and Underwater Acoustic channel)

  • 임요웅;임필섭;이정구;김천석
    • 한국전자통신학회논문지
    • /
    • 제10권9호
    • /
    • pp.979-986
    • /
    • 2015
  • 광케이블을 이용한 보안 솔루션의 기술들은 아직까지 확실한 기술적 안정성을 확보하지 못한 상태이며, 그중 음향 감지를 통한 보안 시스템 역시 여러 가지 변수에 따른 오 경보 및 감지 실패 등의 완벽한 방어 기술을 확보하지 못한 상태이다. 본 논문에서는 수중 음향 통신의 수중 음향통신 채널에 대한 4가지 특성을 조사한다. 또한 수중에서 음향 신호 분석을 통한 광케이블을 이용한 감지 시스템 구축 방안으로서 감지 시스템을 구축한다. 또한 해저 광케이블의 신호 특성 분석과 잡음 분석을 수행한 후 이를 실제 적용 가능성을 확인한다.