• Title/Summary/Keyword: Signal sensing circuit

Search Result 111, Processing Time 0.026 seconds

Replica Technique regarding research for Bit-Line tracking (비트라인 트래킹을 위한 replica 기술에 관한 연구)

  • Oh, Se-Hyeok;Jung, Han-wool;Jung, Seong-Ook
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.167-170
    • /
    • 2016
  • Replica bit-line technique is used for making enable signal of sense amplifier which accurately tracks bit-line of SRAM. However, threshold voltage variation in the replica bit-line circuit changes the cell current, which results in variation of the sense amplifier enable time, $T_{SAE}$. The variation of $T_{SAE}$ makes the sensing operation unstable. In this paper, in addition to conventional replica bit-line delay ($RBL_{conv}$), dual replica bit-line delay (DRBD) and multi-stage dual replica bit-line delay (MDRBD) which are used for reducing $T_{SAE}$ variation are briefly introduced, and the maximum possible number of on-cell which can satisfy $6{\sigma}$ sensing yield is determined through simulation at a supply voltage of 0.6V with 14nm FinFET technology. As a result, it is observed that performance of DRBD and MDRBD is improved 24.4% and 48.3% than $RBL_{conv}$ and energy consumption is reduced which 8% and 32.4% than $RBL_{conv}$.

Development of Strain-gauge-type Rotational Tool Dynamometer and Verification of 3-axis Static Load (스트레인게이지 타입 회전형 공구동력계 개발과 3축 정적 하중 검증)

  • Lee, Dong-Seop;Kim, In-Su;Lee, Se-Han;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.72-80
    • /
    • 2019
  • In this task, the tool dynamometer design and manufacture, and the Ansys S/W structural analysis program for tool attachment that satisfies the cutting force measurement requirements of the tool dynamometer system are used to determine the cutting force generated by metal cutting using 3-axis static structural analysis and the LabVIEW system. The cutting power in a cutting process using a milling tool for processing metals provides useful information for understanding the processing, optimization, tool status monitoring, and tool design. Thus, various methods of measuring cutting power have been proposed. The device consists of a strain-gauge-based sensor fitted to a new design force sensing element, which is then placed in a force reduction. The force-sensing element is designed as a symmetrical cross beam with four arms of a rectangular parallel line. Furthermore, data duplication is eliminated by the appropriate setting the strain gauge attachment position and the construction of a suitable Wheatstone full-bridge circuit. This device is intended for use with rotating spindles such as milling tools. Verification and machining tests were performed to determine the static and dynamic characteristics of the tool dynamometer. The verification tests were performed by analyzing the difference between strain data measured by weight and that derived by theoretical calculations. Processing test was performed by attaching a tool dynamometer to the MCT to analyze data generated by the measuring equipment during machining. To maintain high productivity and precision, the system monitors and suppresses process disturbances such as chatter vibration, imbalances, overload, collision, forced vibration due to tool failure, and excessive tool wear; additionally, a tool dynamometer with a high signal-to-noise ratio is provided.

Development of IoT-based PM2.5 Measuring Device (사물인터넷 기반 초미세먼지(PM2.5) 측정 장치 개발)

  • Loh, Byoung Gook;Choi, Gi Heung
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • An IoT-based particulate matter (PM2.5) sensing device (PSD) is developed. The PSD consists of a PM2.5 sensor, signal processing circuit, and wi-fi enabled-microprocessor along with temperature and humidity sensors. The PSD estimates PM2.5 density by measuring light scattered by PM2.5. To gauge performance of the PSD, PM2.5 density of open air was measured with the PSD and compared with that of the collocated-government-certified measuring station. Measurements were taken at a sampling frequency of 100 Hz and moving-averaged to remove measurement noise. When compared to the result of the measuring station, average percentile error of PM2.5 density from the PSD is found to be 31%. A correlation coefficient is found to be 0.72 which indicates a strong correlation. Instantaneous variation, however, may far exceed average errors, leading to a conclusion that the PSD is more suitable for estimating average trend of PM2.5 density variations than estimating instantaneous PM2.5 density.

Air detector using the change of dielectric constant for medical applications (의료분야 응용을 위한 유전상수 변화를 이용한 공기감지 장치)

  • Kim, Kyung-Hwa;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.864-870
    • /
    • 2010
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed air detection system with air control equipment, detection circuit and LabVIEW system for air sensing. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the Tygon tube of the mock system.

A Study on Output Characteristics of the CO2 Laser by DC-DC Converter System (DC-DC Converter System에 의한 CO2 레이저 출력 특성에 대한 연구)

  • Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Kim, Yong-Cheol;Lee, Yu-Soo;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1816-1819
    • /
    • 2002
  • Nowadays, CO2 lasers are used widely in many applications such as materials fabrication, communications, remote sensing and military purpose etc. It is important to control the laser output power in those fields. In this paper, current resonant half-bridge inverter and Cockcraft-Walton circuit are used to vary the laser output power. This laser power supply is designed and fabricated which has less switching losses and compact size. Also we used an IGBT(Insulated Gate Bipolar Transistor) as a switching device of a power supply and PIC one-chip microprocessor are used to control the gate signal of the IGBT precisely. We investigated the output characteristics of this CO2 laser. As a result, the maximum laser output power of 26[W] is obtained at the resonant frequency of about 13[kHz].

  • PDF

Design and fabrication of an optimized Rogowski coil for plasma current sensing and the operation confidence of Alvand tokamak

  • Eydan, Anna;Shirani, Babak;Sadeghi, Yahya;Asgarian, Mohammad Ali;Noori, Ehsanollah
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2535-2542
    • /
    • 2020
  • To understand the fundamental parameters of Alvand tokamak, A Rogowski coil with an active integrator was designed and constructed. Considering the characteristics of the Alvand tokamak, the structural and electrical parameters affecting the sensor function, were designed. Calibration was performed directly in the presence of plasma. The sensor has a high resistance against interference of external magnetic fields. Plasma current was measured in various experiments. Based on the plasma current profile and loop voltage signal, the time evolution of plasma discharge was investigated and plasma behavior was analyzed. Alvand tokamak discharge was divided into several regions that represents different physical phenomena in the plasma. During the plasma discharge time, plasma had significant changes and its characteristic was not uniform. To understand the plasma behavior in each of the phases, the Rogowski sensor should have sufficient time resolution. The Rogowski sensor with a frequency up to 15 kHz was appropriate for this purpose.

Real time control special quality research for $CO_2$ laser's output change rate stability for accumulation style surgical operation rehabilitation of ventriculus that use Photosensor (Photosensor를 이용한 재활 치료형을 위한 $CO_2$ laser 의 출력변동율 안정을 위한 실시간 제어특성 연구)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.1015-1016
    • /
    • 2006
  • The important parameters deciding the fluctuation of Accumulation style surgical operation of ventriculus laser beam are smoothing capacitor, frequency and he characteristics of laser resonator. In this thesis, we control the fluctuation of medical $CO_2C$ laser in realtime by changing Duty-Ratio of IGBT and switching frequency with fixed the smoothing capacitor to improve the fluctuation of laser beam. We detect the light on laser resonator using a CdS photo sensor to improve ripple factor of laser beam and feedback fluctuated signals refined by a band pass filter into the control circuit to stabilize fluctuation actively. There is much to be desired in the realtime controlling technique of the light on Accumulation style surgical operation of ventriculus laser discharge tube in electrical signal. We propose switching control technique with microprocessor and photo sensing technique by controlling switch devices optimum operation and feedback signals detected by a photo sensor into the laser power supply in order to improve ripple factor of the $CO_2$ laser beam.

  • PDF

A Study on Output Characteristics of the CO2 Laser with DC-DC Converter System (DC-DC Converter System에 의한 CO2 레이저 출력 특성에 관한 연구)

  • Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Kim, Yong-Chul;Lee, Yu-Soo;Kim, Hee-Je
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.176-179
    • /
    • 2002
  • Nowadays, CO2 lasers are used widely in many applications such as materials fabrication. communications, remote sensing and military purpose etc. It is important to control the laser output power in those fields. In this paper, current resonant half-bridge inverter and Cockcraft-Walton circuit are used to vary the laser output power. This laser power supply is designed and fabricated which has less switching losses and compact size. Also we used an IGBT(insulated Gate Bipolar Transistor) as a switching device of a power supply and PIC one-chip microprocessor are used to control the gate signal of the IGBT precisely. We investigated the output characteristics of this CO2 laser. As a result. the maximum laser output power of 26 [W] is obtained at the resonant frequency of about 13 [kHz].

  • PDF

A fully UHF-powered smart sensor tag in food freshness monitoring (음식물 신선도 모니터링을 위한 풀 패시브 UHF 스마트 센서 태그)

  • Lam, Binh Minh;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.89-96
    • /
    • 2018
  • This study aims to develop a fully passive smart sensing tag utilizing RF (Radio Frequency) energy harvesting technology at UHF (Ultra High Frequency) band of 915MHz. To optimize the power collected under various radiated conditions, an efficient energy harvesting module exploiting a boost circuit with maximum power point tracking (MPPT) is employed. Specifically, the proposed tag features two orthogonal antennas to enhance its capability of both energy scavenging and data transmissions. The experimental result shows that the developed smart sensor tag can scavenge an RF input power of as low as 0.19mW at a distance of 4 meters for a 3.6Vdc output. Furthermore, the proposed smart sensor tag performs the feasibility of completely autonomous monitoring food freshness at 2 meters with a low-power sensor array.

Sleep Management Pillow System (수면 관리 베개 시스템)

  • Ahn, Dohyun;Tran, Minh;Park, Jaehee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.212-217
    • /
    • 2019
  • In this paper, a sleep management pillow system for snoring detection and respiration measurement is investigated. The sleep management pillow system consists of four force sensing resistor(FSR) sensors, two microphones(MIC), a pillow, a measurement system. Four FSR sensors attached at the bottom part of the pillow are used for respiration measurement and snoring detection. Two microphones located at the middle left and right of the pillow are utilized for only snoring detection. The respiration and the snoring of ten young people were measured using the sleep management pillow system composed of a data acquisition board, interface circuit, and personal computer. The measurement accuracy of the respiration was about 98% and the measurement accuracy of the snoring was about 97%. The experiment results show that the sleep management pillow system can be used for snoring detection and respiration rate measurement during sleeping.