• Title/Summary/Keyword: Signal Monitoring

Search Result 1,950, Processing Time 0.035 seconds

Signal Generation for Automatic Control of a Monitoring Camera

  • Kim, Jin-Tae;Oh, Jeong-Su
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.4
    • /
    • pp.551-555
    • /
    • 2009
  • This paper proposes a signal generation method for automatic control of a monitoring camera. Using the control signal, the monitoring camera can track a moving object and keep it near the image center for a longer time. The proposed method is estimated in the experiments that automatically move a maker located at the specified position to the image center.

Tool wear monitoring of end mill in slot machining of titanium alloy (티타늄 합금의 슬롯가공에서 엔드밀 공구마멸 감시)

  • 하건호;구세진;김정석;양순철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.101-104
    • /
    • 1995
  • A acoustic emission (AE) sensor has been used to monitor tool were during milling process. The relation between tool wear and AE RMS (Root mean Square) signal was investigated experimentally. A avaliable monitoring index for monitoring toolwear was newly extracted form AE RMS. And on-line monitoring program was developed. The proposed monitoring system has verified experimentally by roughing end milling titanium alloy with TIN coated HSS tool.

  • PDF

Development of ECG Monitoring System on Mobile Platform (모바일 기반의 심전도 모니터링 시스템 개발)

  • Kim M.H.;Yoon J.H.;Lee T.Y.;Lee S.R.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.265-266
    • /
    • 2006
  • In this paper, the ECG monitoring system on mobile platform was proposed, which is very useful to gather, storage and diagnose ECG signal. The existing ECG monitoring system is for indoor environment but this system is for outdoor environment, especially for automobile system. The developed system consisted of data logger using microprocessor and data server fur diagnosis ECG signal. We develop the data acquisition system hardware and data monitoring system for ECG signal.

  • PDF

GNSS Error Generation Simulator for Signal Quality Monitoring of KASS

  • Ji, Gun-Hoon;Choi, Jong-Yeoun;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.4
    • /
    • pp.341-351
    • /
    • 2021
  • In this paper, a GNSS error generation simulator for Signal Quality Monitoring (SQM) is implemented by using Matlab based on mathematical models derived from the effect of GNSS signal and measurement errors. The GNSS signal measurement errors of interest in this paper include three cases such as Evil Wave Form (EWF), Multipath (MP) and Radio Frequency Interference (RFI). In order to verify the validity of the generated measurement errors, a simple form of metrics for detecting and monitoring GNSS errors is included in the simulator. The GNSS errors generated by the simulator are added to the GNSS measurement data from commercial GNSS receiver in real time, and then, the SQM is tested for various scenarios of each case configured by scenario setting of the user.

Development of Horizontal Attitude Monitoring System for Agricultural Robots (농업 로봇 용 수평 자세 모니터링 시스템 개발)

  • Kim, Sung Deuk;Kim, Cheong Worl;Kwon, Ik Hyun;Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.87-91
    • /
    • 2019
  • In this paper, we have development of horizontal attitude monitoring system for agricultural robots. A two-axis gyro sensor and a two-axis accelerometer sensor are used to measure the horizontal attitude angle. The roll angle and pitch angle were measured through the fusion of the gyro sensor signal and the acceleration sensor signal for the horizontal attitude monitoring of the robot. This attitude monitoring system includes GPS and Bluetooth communication module for remote monitoring. The roll angle and pitch angle can be measured by the error of less than 1 degree and the linearity and the reproducibility of the output signal are excellent.

A Practical Measurement Method of the Occupied Bandwidth for 8-VSB DTV Signal Using Modified ACPR

  • Kim, Young Soo;Lee, Bong Gyou;Song, Kyeongmin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.7
    • /
    • pp.3550-3565
    • /
    • 2019
  • This paper proposes a new measurement method for the effective measurement of the 99% occupied bandwidth (OBW) at monitoring stations. Although the OBW measurement of radio signal is recommended by the International Telecommunication Union Radio (ITU-R) with several methods, there still does not exist a clear measurement recommendation or standard for terrestrial DTV signal on-air environment. Modified adjacent channel power ratio (MACPR), which can be applied to 8-VSB (Vestigial Side Band) DTV (Digital Television) signal, is herein defined to verify the results of measurements obtained using the proposed measurement method. MACPR is a proper measuring parameter for determining the measuring area of a monitoring station. From measurement results obtained in real field environment, it has been found that the OBW of 8-VSB DTV signal can be effectively measured in areas where the MACPR value is over 35 dB and when the measurements are repeated more than 600 times in the same reception site. It also has been verified that measured results are within an error range of +/-0.1% compared to results directly obtained at a transmission station. It is expected that the proposed method is able to be employed in order to determine the proper location of monitoring station and provide a reliable OBW measurement procedure for 8-VSB DTV signal on-air environment.

Alarm System for Sudden Infant Death using Bio-Signals (생체 신호를 활용한 영아 돌연사 알람 시스템)

  • Yun, Su-Jeong;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.197-202
    • /
    • 2016
  • In this paper, a danger signal to tell caregivers when a dangerous situation occurs, the bio-signal analysis in infants to prevent sudden infant death sudden infant death propose a monitoring system. The Sudden infant death (SID) refers to a healthy baby is unexplained deaths between birth year in the month. Sudden infant death proposed monitoring system is composed of a processor unit and the monitoring and alarm part for processing part and the biological signal sensing biological signals. Using the PPG sensor to sense the bio-signal and the processor unit the signal obtained through the sensor by removing the motion artifact was able to alarm and monitoring the parent.The proposed system will send the alarm to monitoring and alerting caregivers if the risk situation by analyzing the heart rate of the infant. With the actual implementation of the system to evaluate the performance of the monitoring system.

A Study on Tool Monitoring for High Speed Tapping using AE Signal (AE센서를 이용한 고속 탭핑용 공구 모니터링에 관한 연구)

  • 김용규;이돈진;김선호;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.315-318
    • /
    • 1997
  • In terms of productivity, the speed of machining process has been increasing in most of engineering part. But the tapping process does not reach at enough level compared with other machining processes because of its complicate cutting mechanism. In the high speed tapping process, the one of important elements is tool monitoring system to prevent tool breakage. This paper describes tool monitoring system by acoustic emission(AE) in the tapping process. We used 2 types of AE sensors in this test. The one is commercial sensor which is used in other machining monitoring system like polishing and the other is a self-fabricated sensor for this test. In this test we purpose to find out the frequency of AE signal in tapping process and verify the possibility of applying AE sensor in in-process tapping monitoring system. Also grasp of characteristic of tapping process by AE signal is handled.

  • PDF

A Study on the Signal Analysis of Loose Parts Monitoring System (LPMS 신호분석 연구)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.839-841
    • /
    • 2014
  • The Nuclear Steam Supply System(NSSS) is designed to provide an integrated approach that includes areas of monitoring relevant to the integrity of the NSSS. LPMS is designed to function as an alarm system by providing sensor channel alarms for the associated subsystems. LPMS is equipped to provide analysis tools for new alarm events, historical events and for historical periodically stored channel data (e.g. waveforms) for most channels. This paper is intended to introduce the diagnosis principle and abnormal symptom of loose parts monitoring system as a monitoring tool in Nuclear Steam Supply System. And also, we are going to introduce signal analysis program in order to perform the actual diagnosis in power plants.

  • PDF

Development of a Non-contact Type Magnetic Signal Monitoring Equipment for Automotive Electric Devices (비접촉식 자동차 전장용 자기신호 측정 장치)

  • Yang, Hyong-Yeol;Yang, Seung-Hak
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.381-386
    • /
    • 2010
  • A non-contact type magnetic signal monitoring equipment for automotive electric devices is proposed in this paper. There are many kinds of actuators in the car like solenoid, relay, motor, injector, etc which are operated by magnetic energy. It is difficult to find out whether the actuators operate well or not because the terminals of the actuators are combined to the connectors. In this paper a non-contact type magnetic signal monitoring equipment using Hall effect sensor is proposed to measure the magnetic signal of the actuators very easily to find out the actuators' operating status. The simulation and experimental results show that the developed equipment is very useful and has good performance.