• 제목/요약/키워드: Signal Monitoring

검색결과 1,950건 처리시간 0.033초

Protocol implementation for simultaneous signal continuation acquisition of industrial plant machine condition in wireless sensor networks (산업플랜트 기계상태 동시신호 연속취득을 위한 무선센서 네트워크프로토콜 구현)

  • Lee, Hoo-Rock;Chung, Kyung-Yul;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권7호
    • /
    • pp.760-764
    • /
    • 2015
  • Wireless sensors, installed on machinery, and Time Division Multiple Access (TDMA) transmission make an ideal system for monitoring machine conditions in industrial plants because there is no need for electronic wiring. However, there has not yet been a successful field application of such a system, capable of continuously transmitting data at sample rates greater than 100 Hz. In this research, a TDMA network protocol capable of acquiring data from multiple sensors at sample rates greater than 100 Hz was developed for field application. The protocol was implemented in a single cluster-star topology network, and the system was evaluated based on the node number and transmission distance. Network simulator 2 (ns-2) was used for a real field simulation. Non-TDMA and TDMA protocol cases were compared using four sensor nodes. In the cases of 20-s and 40-s transmission times, there was little difference between the reception rates of the non-TDMA and TDMA systems. However, the difference was much greater when using a 60-s transmission time.

Waveform Sorting of Rabbit Retinal Ganglion Cell Activity Recorded with Multielectrode Array (다채널전극으로 기록한 토끼 망막신경절세포의 활동전위 파형 구분)

  • Jin Gye Hwan;Lee Tae Soo;Goo Yang Sook
    • Progress in Medical Physics
    • /
    • 제16권3호
    • /
    • pp.148-154
    • /
    • 2005
  • Since the output of retina for visual stimulus is carried by neurons of very diverse functional properties, it is not adequate to use conventional single electrode for recording the retinal action potential. For this purpose, we used newly developed multichannel recording system for monitoring the simultaneous electrical activities of many neurons in a functioning piece of retina. Retinal action potentials are recorded with an extra-cellular planar array of 60 microelectrodes. In studying the collective activity of the ganglion cell population it is essential to recognize basic functional distinctions between individual neurons. Therefore, it is necessary to detect and to classify the action potential of each ganglion cell out of mixed signal. We programmed M-files with MATLAB for this sorting process. This processing is mandatory for further analysis, e.g. poststimulus time histogram (PSTH), auto-correlogram, and cross-correlogram. We established MATLAB based protocol for waveform classification and verified that this approach was effective as an initial spike sorting method.

  • PDF

Bleeding characteristics of coupling materials for installation of acoustic emission (AE) sensor (AE 센서 설치를 위한 커플링 재료의 블리딩 특성)

  • Lee, Jong-Won;Kim, Hyunwoo;Kim, Min-Koan;Oh, Tae-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • 제19권4호
    • /
    • pp.635-650
    • /
    • 2017
  • Acoustic emission (AE) sensors have broadly used to monitor the damage of underground structures and tunnels. The reliability of measured signal is determined by the coupling condition of the AE sensors which are embedded in the target underground structure. To secure the reliability of health monitoring results, it is important to understand the characteristics of the coupling materials. In this study, laboratory tests were performed using portland cement, micro cement, and gypsum as coupling materials in order to verify the bleeding characteristics. The effective parameters for bleeding were determined to be water-cement ratio, material type, curing time, and injected volume of coupling materials. As a results of the experimental study, the bleeding rate increases with an increase in a water-cement ratio and an injected volume; for portland cement, water-cement ratio and injected volume effects are larger than the micro cement. However, curing time is not much effective for occurrence of the bleeding phenomenon. It is anticipated that this study may be useful for the selection of suitable coupling materials for installation of acoustic emission sensors.

Endpoint Detection in Semiconductor Etch Process Using OPM Sensor

  • Arshad, Zeeshan;Choi, Somang;Jang, Boen;Hong, Sang Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.237.1-237.1
    • /
    • 2014
  • Etching is one of the most important steps in semiconductor manufacturing. In etch process control a critical task is to stop the etch process when the layer to be etched has been removed. If the etch process is allowed to continue beyond this time, the material gets over-etched and the lower layer is partially removed. On the other hand if the etch process is stopped too early, part of the layer to be etched still remains, called under-etched. Endpoint detection (EPD) is used to detect the most accurate time to stop the etch process in order to avoid over or under etch. The goal of this research is to develop a hardware and software system for EPD. The hardware consists of an Optical Plasma Monitor (OPM) sensor which is used to continuously monitor the plasma optical emission intensity during the etch process. The OPM software was developed to acquire and analyze the data to perform EPD. Our EPD algorithm is based on the following theory. As the etch process starts the plasma generated in the vacuum is added with the by-products from the etch reactions on the layer being etched. As the endpoint reaches and the layer gets completely removed the plasma constituents change gradually changing the optical intensity of the plasma. Although the change in optical intensity is not apparent, the difference in the plasma constituents when the endpoint has reached leaves a unique signature in the data gathered. Though not detectable in time domain, this signature could be obscured in the frequency spectrum of the data. By filtering and analysis of the changes in the frequency spectrum before and after the endpoint we could extract this signature. In order to do that, first, the EPD algorithm converts the time series signal into frequency domain. Next the noise in the frequency spectrum is removed to look for the useful frequency constituents of the data. Once these useful frequencies have been selected, they are monitored continuously in time and using a sub-algorithm the endpoint is detected when significant changes are observed in those signals. The experiment consisted of three kinds of etch processes; ashing, SiO2 on Si etch and metal on Si etch to develop and evaluate the EPD system.

  • PDF

Trace level analysis of Pb in plasma by inductively coupled plasma/mass spectrometry (유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • 제25권3호
    • /
    • pp.190-196
    • /
    • 2012
  • The human exposure of lead has usually detected the amount of lead in the whole blood, however, this method has a shortcoming to give the information on the short-term exposure to lead. In that sense, it is desirable to estimates the level of lead in plasma to draw the chronic bio-marker of lead exposure even though it is difficult to measure lead of several ng/L. An inductively coupled plasma-mass spectrometry (ICP-MS) method was developed for determining lead in plasma as the chronic bio-marker of lead of workers. To minimize the contamination of lead from the environment, we constructed class 1,000 clean room and compared the amount of floating dust before and after the operation of the clean room. The limit of detection (LOD) and the limit of quantification (LOQ) of lead in fetal bovine serum were 4.3 ng/L and 12.2 ng/L by NIOSH method (statistical calculation method) and 7.0 ng/L and 22.1 ng/L by signal/noise ratio, respectively. The accuracy was in a range of 92.3-101.3%, and the precision of the assay was less than 4% in the samples spiked in the concentration of 20 ng/L and 2,000 ng/L. The method was simple, reproducible and sensitive enough to permit reliable analysis of lead to the ng/L level in plasma and/or serum. The method was also useful for the biological monitoring of chronic exposure to lead.

Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan (Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구)

  • Kim, Jung-Yul;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제12권1호
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

Determination of alkylphenol ethoxylate in water by high performance liquid chromatography/electrospray ionization/mass spectrometry (HPLC/ESI/MS를 이용한 물 중의 알킬페놀에톡실레이트 분석)

  • Lee, Jeongae;Park, Song-Ja;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.263-270
    • /
    • 2004
  • A method is described for the analysis of short-chain alkylphenol ethoxylates (APEOs), 4-octylphenol-di-ethoxylate (OP2EO) and 4-nonylphenol-di-ethoxylate (NP2EO), in drinking water or wastewater using reversed phase high-performance liquid chromatography with electrospray ionization mass spectrometry. The solvent system was water and methanol containing $10{\mu}M$ trifluoroacetic acid as an ionization solvent. We acidified 1 L of water samples to less than pH 2 with concentrated $H_2SO_4$ and loaded onto Sep-Pak $C_{18}$, and eluted with acetone. The calibration of OP2EO and NP2EO was performed for the concentration range from 20 to 500 ng/L and the correlation coefficients were 0.999 and 0.990, respectively. The limits of detection were 20 ng/L (OP2EO) and 50 ng/L (NP2EO) at a signal-to-noise ratio of 3. Accuracy and precision of this analytical method were 85.8 ~ 122.1% and 8.2 ~ 18.8%, respectively. The proposed method allowed a sensitive and rapid detection of OP2EO and NP2EO and it could be applied for monitoring of APEOs from environmental samples.

Development of a Raman Lidar System for Remote Monitoring of Hydrogen Gas (수소 가스 원격 모니터링을 위한 라만 라이다 시스템 개발)

  • Choi, In Young;Baik, Sung Hoon;Park, Nak Gyu;Kang, Hee Young;Kim, Jin Ho;Lee, Na Jong
    • Korean Journal of Optics and Photonics
    • /
    • 제28권4호
    • /
    • pp.166-171
    • /
    • 2017
  • Hydrogen gas is a green energy sources because it features no emission of pollutants during combustion. But hydrogen gas is very dangerous, being flammable and very explosive. Hydrogen gas detection is very important for the safety of a nuclear power plant. Hydrogen gas is generated by oxidation of nuclear fuel cladding during a critical accident, and leads to serious secondary damage in the containment building. This paper discusses the development of a Raman lidar system for remote detection and measurement of hydrogen gas. A small, portable Raman lidar system was designed, and a measurement algorithm was developed to quantitatively measure hydrogen gas concentration. To verify the capability of measuring hydrogen gas with the developed Raman lidar system, experiments were carried out under daytime outdoor conditions by using a gas chamber that can adjust the hydrogen gas density. As results, our Raman lidar system is able to measure a minimum density of 0.67 vol. % hydrogen gas at a distance of 20 m.

Detection of m-toluate in Soils using Bioluminescence Producing Recombinant Bacteria (유전자 재조합 발광균주를 이용한 토양 오염원 m-toluate 탐지)

  • Kong, In-Chul;Kim, Myung-Hee;Jung, Yun-Ho;Ko, Kyung-Seok;Kim, Jae-Gon;Shin, Sung-Chun
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제27권5호
    • /
    • pp.507-512
    • /
    • 2005
  • This research focuses on the development and application of a method for the detection of m-toluate in soils using a genetically engineered bioluminescent bacteria, Pseudomonas putida mt-2 KG1206. KG1206 produces light by direct (m-toluate and benzoate) and indirect (toluene analogs) inducers. For detection of m-toluate in soil system, 9.9 mL strain was amended with 0.1 mL soil ethanol extractant. A high correlation ($r^2>0.97$) was observed between bioluminescence and m-toluate concentration. The unknown concentrations of m-toluate in soil samples were pre-determined using a method developed based on bioluminescence activity of strain with extracted inducers. Values between by LC analysis and bioluminescence activity show moderate statistical results. These results demonstrate the feasibility of recombinant bioluminescent microorganism, engineered to generate a quantifiable bioluminescence signal in response to specific pollutants, may serve as combined sensing and reporting tools in environmental monitoring.

A Study on the Propagation Environment for VHF Maritime Digital Communications Operation in South Sea Area (남해안의 VHF 해상디지털통신 운용을 위한 전파환경 연구)

  • Ju, Yang-Ro;Kim, Kab-Ki;Choi, Jo-Cheon;Lee, Seong-Ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제18권6호
    • /
    • pp.1310-1316
    • /
    • 2014
  • The IMO has recommended on VHF digital communications operation for sailing ships from 2017. And ships more than 5 tons is obliged to digital communications by fishing Vessels Act and Vessel Safety Act in domestic. The owner of all vessel is equipped to the automatic position reporting device in accordance with the Notice of the Ministry of Oceans and Fisheries to regulations, It shall be ensure to navigations safety and in order to respond quickly in the event of maritime accidents on all vessels. The info-communications station of fishery is operating the automatic position reporting system using the VHF DSC in east sea from 2012, Continuously, which is underway the install plan in south sea and yellow sea. But this plan is very difficult, because of propagation environment is poor on account of complicated coastline and many islands. This paper has analyzed the propagation coverage for position setting of coast station in south sea and the traffic zone set up by compare with RSSI and methode of navigation tracking by VMS.