• Title/Summary/Keyword: Signal Location

Search Result 1,293, Processing Time 0.03 seconds

A Study on the Multi-Layer of Religious Inertia Represented in Sense of Place and Cultural Remains at Mt. Bak-wha (장소성과 문화경관으로 해석한 태안 백화산의 다층적 종교 관성)

  • Rho, Jae-Hyun;Park, Joo-Sung;Goh, Yeo-Bin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.4
    • /
    • pp.36-48
    • /
    • 2010
  • The objectives of this study are to research and analyze the positioning of Mt. Back Hwa(白華山) and the characteristics of its neighboring cultural scenery based on the Two Seated Buddah Temple, a small Buddhist temple of Taeul in Taean and to view both landscape geographic codes and religious attractions over Mt. Back Hwa by discussing its expression and meaning for the scenery scattered or nested over this districts. The panoramic view of west shows the character of Mt. Back Hwa as a magnanimity of Buddhist Goddess of Mercy which is viewed as a view point field no less than its location as a landscape target and its singularity as a rocky mountain. The ancient castle, signal beacon post and the small Buddhist temple of Taeul to be read importantly in the old map and SinjeungDongkukyeojiseungram(新增東國輿地勝覽) form the core of place identity, and a number of carve(engrave) letters such as Eopungdae(御風臺), Youngsadae(永思臺), etc. show the prospect of this mountain and monumentality derived from place characteristics. In addition removing of Taeiljeon, a portrait scroll of Dangun, national ancestor makes possible to guess the national status hold by Mt. Back Hwa in advance and to know that it has symbiotic relationship with indigenous religion and shares with the universal locality which have been continued for a long time through a portrait scroll of Dangun enshrined in Samsunggak. More than anything else, however the Rock-carved Buddha Triad in Taean, Giant Buddha of Baekjae era enshrined in the small Buddhist temple of Taeul is not only why Mt. Back Hwa, magnanimity of Buddhist Goddess of Mercy exists but also a signifier. In spite of such a placity, the union ideas of confucianism, buddhism and doctrinism of buddhism prevailed in the Late Joseon Dynasty allows the cultural phenomenon of taoism to be read in the same weight through Ilsogae(一笑溪) and Gammodae(感慕臺) which are mountain stream and pond area respectively centered in the carve letter, 'Taeeuldongcheon(太乙洞天)' constructed in front of the small Buddhist temple of Taeul, the Baduk board type of rock carvings engraved over them and a number of traces of carve letters made by confucian scholars since the Middle of Joseon Dynasty. The reason such various cultural sceneries are mixed in Mt. Back Hwa is in the results of inheritance of religious places and fusion of sprit of the times, and the various type of cultural scenery elements scattered in Mt. Back Hwa are deemed as unique geographic code to understand the multi-layered placity and the characteristics of scenery of Mt. Back Hwa in Taean.

DC Resistivity method to image the underground structure beneath river or lake bottom (하저 지반특성 규명을 위한 전기비저항 탐사)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon;Son Jeongsul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.139-162
    • /
    • 2002
  • Since weak zones or geological lineaments are likely to be eroded, weak zones may develop beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. Dc resistivity surveys, however, have seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of case histories, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing at the water bottom, since the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the dc resistivity method can provide the fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio data as well as the high resolving power. The method installing electrodes at the water bottom is suitable to the detailed survey because of much higher resolving power, whereas the method floating them, especially streamer dc resistivity survey, is to the reconnaissance survey owing of very high speed of field work.

  • PDF

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF