• Title/Summary/Keyword: Signal Equipment

검색결과 958건 처리시간 0.184초

DC 궤도회로의 효율적인 운용방법에 대한 연구 (A study on efficient operation of DC track circuit)

  • 장동완;전태현
    • 조명전기설비학회논문지
    • /
    • 제28권2호
    • /
    • pp.70-75
    • /
    • 2014
  • A track circuit is a critical piece of equipment that allows the existence of the trains on the track to be detected. Train detection is very important for the signal safety equipment. It allows for the confirmation of a train's location, the locking of switch points, the coordination of safe distance between trains, and the advance notice of a train's arrival. Track circuits can be powered by AC or DC. The DC track circuits are usually used on non-electrified tracks. On these tracks, many signal errors can be caused by lightning or problems with the power source. These problems can also cause damages to the rectifiers which must be repaired or replaced, promptly. This issue is especially problematic in the summer because of the higher frequency of thunderstorms. Issues with track circuits also cause problems for other equipment, such as railroad crossings and switch points. This further disrupts the safe operation of trains. This study aims to enhance maintenance efficiency and improve safety by utilizing parallel operation and multiplexing of a DC track circuit as well as installing an external surge protector. The experimental results on the operation of the proposed method is also presented.

RS-170a 영상 신호에 대한 EMI 및 낙뢰 간접영향 보호 설계 (Protection Design for EMI and Indirect Lightning Effect for RS-170a Video Signal)

  • 조성진;심용기;김성훈;박준현
    • 한국항행학회논문지
    • /
    • 제23권5호
    • /
    • pp.444-451
    • /
    • 2019
  • 본 논문에서는 항공기 탑재장비의 RS-170a 영상 신호에 대한 EMI 및 낙뢰 간접영향에 대한 보호 대책을 설명한다. 항공기 탑재장비는 외부 환경으로부터 발생하는 전자파 간섭과 항공기 낙뢰 피격시 발생하는 낙뢰 간접영향으로 부터 발생하는 서지 전압에 의해 장비의 오작동이나 물리적 손상의 위험에 노출되어있다. 이러한 위험으로부터 장비를 보호하기 위해서는 전자파 간섭 및 간접 낙뢰 효과에 대한 보호 설계를 장비에 적용해야 하는데, 신호의 전압이 낮고 주파수 대역이 높을수록 보호 회로에 의한 신호 왜곡이 문제가 된다. 따라서 본 논문에서는 EMI 및 낙뢰 간접영향에 대한 일반적인 보호 설계 방법과, RS-170a 신호를 기준으로 보호 설계 적용에 따른 영상 신호 왜곡 현상을 최소화하기 위한 고려 사항을 소개한다. 그리고 이 과정에서 논한 고려 사항을 적용해 실제 장비 설계를 개선한 사례를 소개한다.

전력기기의 아크 플래시 진단 알고리즘에 관한 연구 (A Study on the Diagnostic Algorithm for Arc Flash of Power Equipment)

  • 이덕진
    • 한국전기전자재료학회논문지
    • /
    • 제29권7호
    • /
    • pp.449-453
    • /
    • 2016
  • The amount of electrical energy has been increased with the rapid development of the industrial society. Accordingly, operating voltage of the power equipment and facility capacity are continuously increasing. Development trends of recent high-voltage electrical equipment are ultra high-voltage, large-capacity and compact. Early diagnosis of a failure of the power plant has been emerging as an important task as to supply high quality power to users. In this study, we have tried to develope an algorithm for distinguishing an arc fault signal generated in the power plant by using UV sensor.

한국형 컨테이너 터미널 자동화를 위한 RF 시스템 개발 (Development of RF system for Automatic Container Terminal)

  • 윤현성;이창호;변건식
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2000년도 추계종합학술대회논문집
    • /
    • pp.41-44
    • /
    • 2000
  • 본 논문에서는 동아대학교 RRC에서 개발한 게이트 자동화 시스템에 적용된 DSRC(Dedicated Short Range Communication) 시스템을 항만 내 야드 자동화에서도 이용하기 위해 이동 수송 차량에 장착되는 OBE(On-Board Equipment)와 야드에 설치되는 RSE(Road Side Equipment)간의 통신 소프트웨어 알고리즘을 제안하였다. 컨테이너 야드와 하역 시스템의 자동화를 구현하기 위해 OBE와 RSE간을 DSRC 방식으로 통신할 때 통신 대상에 따른 송수신 정보의 분류, 통신 대상의 분류 및 특성을 분석하였다.

  • PDF

범용 DSP를 이용한 RRS 기반 기지국 통신 플랫폼 구현 (Implementation of RRS-based Base station Communication platform using General-Purpose DSP)

  • 김호일;안흥섭;최승원
    • 디지털산업정보학회논문지
    • /
    • 제14권4호
    • /
    • pp.87-92
    • /
    • 2018
  • One of the problems with the base station equipment is that there is a large difference between the replacement time of the hardware equipment such as the base station equipment and the radio access equipment, and the evolution period of the communication standard. Therefore, the base station communication platform must be flexible enough to handle the evolving communication standards after purchase. Recent research on reconfigurable communications platforms has focused on the efficient architecture of the communications platform to meet these requirements through software downloads while still using existing hardware. This paper presents a prototype of a base station communications platform based on the ETSI standard reconfigurable architecture. The communication platform presented in this paper is implemented as an ETSI standard reconfigurable architecture using a general-purpose DSP (Digital Signal Processor). In the implemented prototype, we verify the real-time feasibility of communication protocol updates through software reconfiguration.

최적의 케이블 모뎀 PHY 성능 구현 및 케이블 망 측정 시스템 개발 (Developing the Measurement System with Establishing the PHY Performance of Best Proper Cable Modem)

  • 이경문;고재평;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제14권2호
    • /
    • pp.205-211
    • /
    • 2008
  • This paper describes the method aimed at establishing the equipment measuring the parameter of Cable Network by Best proper Cable Modem and PDA through RS232 interface. In this paper, we propose our creative experimental configuration and develope the Cable Modem (DOCSIS 2.0) superior more performing than the referred Cable Modem (DOCSIS 1.0, 1.1) and the measuring equipment of HFC network compositing of Cable Modem and PDA through RS232 interface. This equipment analyzes Upstream (U/S) and Downstream (D/S) Signal quality and generates the signal of Upstream by CW signal. The paper also provides the experimental results to check the Best Proper Cable Modem and the displayed screen for parameters for SNR, BER and the demodulated IQ diagram of 256QAM through LCD of PDA. Henceforth, it'll be possible to support a variety of the functions for E-mail, Internet, the speed test of WEB connection and the transmission of the measured result real time by PDA.

공압을 이용한 자동포장장치 (Auto packer with pneumatic equipment)

  • 김장호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.335-339
    • /
    • 1987
  • In this report, automatic packing equipment for dairy milk is presented. For food industry, Pneumatic System is widely applied because of it's environments. So, for the actuation, signal processing and sensing of this auto-packer, all pneumatic equipments was applied.

  • PDF

도시철도역사의 저압선로 및 기기에서의 지락사고 방지 방안에 관한 검토 (A Study on ground fault at low voltage line and apparatus in urban railway station)

  • 민경윤;김진호;한학수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.699-704
    • /
    • 2005
  • In the station of the railway and the subway various illumination equipment and a general power equipment for a passenger convenience, the signal equipment and the communication equipment which is necessary to the train operation provided. At the all of like this equipment from the electric room which is established in each station by changing from high voltage to low voltage and it supplies from the illumination transformer, the power transformer and the signal transformer. If it supplies to the equipment from the high voltage to the low voltage, it must be established to contact protection device in between the high voltage coil and the low voltage coil. Also it must do the grounding faulting device at the low voltage lines, the earthing devices at apparatus for the protection of an electric shock and an electric fire by the electric relation law. Compared the related regulations between the facilities which require protective functions such as grounding fault or earthing in public utilities like subway stations, and the facilities which do not require line earthing or protective functions such as electricity supplied for signalling the train. Also, will describe a countermeasure for the accident from a grounding fault.

  • PDF

소형 굴삭기의 원격제어를 위한 주행 알고리즘 및 통신특성에 관한 연구 (A Study on Driving Algorithm and Communication Characteristics for Remote Control of Mini Excavator)

  • 정진범;김경수
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.81-90
    • /
    • 2018
  • Indoor construction site such as building demolition sites, tunnel, vinyl house, and cattle shed are subject to various risk factors such as falling stones, soot and bad odors. However, most of the mini excavators have no cabin that can protect the driver from such risk factors. Therefore, researches on remote control technology of construction equipment are actively conducted as a method for protecting the driver from the risk factors occurring in the working environment. For effective remote control, it is necessary to be able to control the travelling and work using a portable small transmitter. However, due to the limitation of the size of the transmitter, complex operation control is required to control two or more actuators with a single joystick. Also, it is essential to check how remote control characteristics change in various environments such as distance, signal strength, obstacle. Therefore, in this study, an algorithm that can control two actuators simultaneously with a single joystick signal was developed, and a communication method suitable for indoor and outdoor mini construction equipment by analyzing experimentally how the remote control characteristics vary according to various work environments and telecommunication methods proposed.