• 제목/요약/키워드: Side-Load

검색결과 1,240건 처리시간 0.027초

팁간극이 고선회각 터빈 동익 평면팁 표면에서의 열전달에 미치는 영향 (Effect of Tip Clearance Height on Heat Transfer Characteristics on the Plane Tip Surface of a High-Turning Turbine Rotor Blade)

  • 문현석;이상우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.173-177
    • /
    • 2005
  • The heat/mass transfer characteristics on the plane tip surface of a high-turning first-stage turbine rotor blade has been investigated by employing the naphthalene sublimation technique. The heat/mass transfer coefficient is measured for four tip clearance height-to-chord ratios of h/c = 1.0%, 2.0%, 3.0%, and 4% at the Reynolds number of $2.09{\times}105$. The result shows that at lower h/c, there exists a strong flow separation/re-attachment process, which results in severe thermal load along the pressure-side comer. As h/c increases, the re-attachment is occurred further downstream of the pressure-side comer with lower thermal load. At higher h/c, a pair of vortices on the tip surface near the leading edge are found along the pressure-side and suction-side comers, and the pressure-side tip vortex have significant influence even on the mid-chord local heat transfer.

  • PDF

GHP 난방 모드 운전시 실시간 부하 추정방법에 관한 연구 (A Study on Estimating Real-time Thermal Load During GHP Operation in Heating Mode)

  • 서정아;신영기;오세제;정상덕;지경철;정진희
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.32-37
    • /
    • 2011
  • The present study has been conducted to propose an algorithm regarding real-time load estimation of a gas engine-driven heat pump. In the study, thermal load of an indoor unit is estimated in terms of air-side and refrigerant-side. The air-side estimation is based on a typical heat exchanger model and is found to be in good agreement with experimental data. When it comes to the refrigerant-side load, a pressure difference across a valve must be estimated. For the estimation, it is assumed to be proportional to a bigger pressure difference that is available either by measurement or by estimation. Relative good agreement between the air- and refrigerant-sides suggests that the assumption may be plausible for the load estimation. The summed flow rate of all of indoor units is in good agreement with the throughput of the compressor which are calculated from the manufacturer's software. Accordingly, estimated thermal loads are also in good agreement. The proposed algorithm may be further developed for improved control algorithm and fault diagnosis.

상지 좌우 운동부하 편차방식이 근력 불균형 개선에 미치는 영향 (Effect on Improvement of Muscle Strength Imbalance according to Load Deviation Pattern of Left and Right Arms in Upper Limbs)

  • 강승록;서신배;정구영;배종진;유창호;유미;문동안;정장식;권대규
    • 한국정밀공학회지
    • /
    • 제29권9호
    • /
    • pp.1026-1034
    • /
    • 2012
  • The purpose of this study was to verify the validation of effect on improvement of muscle strength unbalance according to exercise load deviation during rowing exercise. We performed evaluation of muscular activity and joint torque before the test. We recruited twenty subjects who one side's muscle strength is bigger in more 20% than other side. Subjects divided two groups. One is dominant left side and the other was dominant right side. Subjects performed rowing exercise in electric load deviation rowing equipment (Robo.gym, Humonic Co., Ltd., Daegu, Korea). Exercise performed four sets a day including 25 times a set, and three days a week. Measurements consist of evaluation of muscular activity and joint torque. Exercise load deviation adapted that different value of muscle strength in both arms multiplied 1RM% and added 1RM 50%. The results in adapted load deviation showed that the differences of maximal peak torque in 22.75% were getting increase significantly during exercise in 5.72%. This interpreted that rowing exercise with loading deviation types could provide muscle strength and muscular endurance exercise in same time for balance. Our study found out that loading deviation could provide muscle strength and muscular endurance exercise for improving muscle unbalance.

Experimental investigation of inelastic buckling of built-up steel columns

  • Hawileh, Rami A.;Abed, Farid;Abu-Obeidah, Adi S.;Abdalla, Jamal A.
    • Steel and Composite Structures
    • /
    • 제13권3호
    • /
    • pp.295-308
    • /
    • 2012
  • This paper experimentally investigated the buckling capacity of built-up steel columns mainly, Cruciform Columns (CC) and Side-to-Side (SS) columns fabricated from two Universal Beam (UB) sections. A series of nine experimental tests comprised of three UB sections, three CC sections and three SS sections with different lengths were tested to failure to measure the ultimate axial capacity of each column section. The lengths used for each category of columns were 1.8, 2.0, and 2.2 m with slenderness ratios ranging from 39-105. The measured buckling loads of the tested specimens were compared with the predicted ultimate axial capacity using Eurocode 3, AISC LRFD, and BS 5959-1. It was observed that the failure modes of the specimens included flexural buckling, local buckling and flexural-torsional buckling. The results showed that the ultimate axial capacity of the tested cruciform and side-by-side columns were higher than the code predicted design values by up to 20%, with AISC LRFD design values being the least conservative and the Eurocode 3 design values being the most conservative. This study has concluded that cruciform column and side-to-side welded flange columns using universal beam sections are efficient built-up sections that have larger ultimate axial load capacity, larger stiffness with saving in the weight of steel used compared to its equivalent universal beam counterpart.

Effect of construction sequence on three-arch tunnel behavior-Numerical investigation

  • Yoo, C.;Choi, J.
    • Geomechanics and Engineering
    • /
    • 제15권3호
    • /
    • pp.911-917
    • /
    • 2018
  • This paper concerns a numerical investigation on the effect of construction sequence on three-arch (3-Arch) tunnel behavior. A three-arch tunnel section adopted in a railway tunnel construction site was considered in this study. A calibrated 3D finite element model was used to conduct a parametric study on a variety of construction scenarios. The results of analyses were examined in terms of tunnel and ground surface settlements, shotcrete lining stresses, loads and stresses developed in center column in relation to the tunnel construction sequence. In particular, the effect of the side tunnel construction sequence on the structural performance of the center structure was fully examined. The results indicated that the load, thus stress, in the center structure can be smaller when excavating two side tunnels from opposite direction than excavating in the same direction. Also revealed was that no face lagging distance between the two side tunnels impose less ground load to the center structure. Fundamental governing mechanism of three-arch tunnel behavior is also discussed based on the results.

부하특성별 제어로직을 적용한 직접 부하제어 시스템 활용 (An Application of Direct Load Control Using Control Logic Based On Load Properties)

  • 두석배;김정욱;김형중;김희철;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2668-2670
    • /
    • 2004
  • This paper presents an advanced load control method in Direct Load Control(DLC) system. It is important to aggregate a various demand side resource which is surely controllable at the peak power time for a successful DLC system. Because the DLC system use simple On/Off control that may cause a harmful effect on a plant to reduce a peak power load, there are some restriction on deriving a voluntary participation of demand side resource. So it needs a new approach to direct load control method, and this paper describes an advanced load control method using control logic which is based on load properties. This method is easy to take account of a various characteristic of load, it can be use as a dynamic control logic which is good for adaptive control. The suggested control logic method is verified by modeling a control logic for a turbo refrigerator which affects on peak power in summer season.

  • PDF

낙동강 유역에 대한 일별 유달부하량 산정모델개발 I. 모델식의 보정 및 검증 (Development of the Estimation Model on Daily Pollutant Loads for the Watersheds in the Nakdong River Basin I. Correction and Verification for the Model)

  • 윤영삼;김문수;유재정;이혜진;이준배;양상용
    • 한국환경과학회지
    • /
    • 제16권2호
    • /
    • pp.203-210
    • /
    • 2007
  • The delivery load data obtained from Nakdong river basin are used for developing the model estimating the daily delivery load on the main side streams of Nakdong River. The developed model assesses the daily contamination loads of the main thirteen side streams that contribute to the main stream of Nakdong river. It is developed that the model using the simplified equation that can estimate the daily delivery loads on the side main streams of Nakdong river for a period of having no data of the water quality and flow. The developed model for estimating the daily delivery loads from the main side streams in Nakdong river basin on each item such as BOD, TN, and TP is expressed as Daily delivery load ($\frac{kg}{day}$) = Production load $(\frac{kg}{day}){\times}(1-{\alpha}){\times}(\frac{daily\;runoff}{average\;runoff\;per\;year}){\gamma}$. The estimated values obtained by using the model are almost fit to the calculated values (real data) that have been acquired from the thirteen main side streams in Nakdong river basin. The correlation coefficient values, R, that indicate the correlation between the estimated and the calculated show over 0.7 that mean the estimated values from the used model are adapted to the real data except TN values of Nam-river, Hwang-river, Gam-river, We-river. Especially, the correlation of TP values between the estimated and the calculated implies quite a creditable data to use.

직접부하제어 시스템의 새로운 부하 배분 알고리즘 (An New Load Allocation Algorithms of Direct Load Control)

  • 김정욱
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.407-410
    • /
    • 2010
  • This paper presents an advanced load allocation algorithm in Direct Load Control(DLC) system. It is important to aggregate a various demand side resource which is surely controllable at the peak power time for a successful DLC system. Previous load allocation algorithm appropriate for DLC system is based on interchanged information, but, this algorithm can not derive optimal solutions. In this paper, we develop the optimal algorithm and the new load allocation algorithm in polynomial time. The simulation results show that the proposed heuristic algorithm for DLC system is very effective.

차체구조용 박육단면부재의 단면형상변화에 따른 축압궤 특성에 관한 연구 (A Study on the Axial Collapse Characteristics of Thin-Walled Members for Vehicles on the Variation of Section Shapes)

  • 이길성;백경윤;차천석;정진오;양인영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1549-1552
    • /
    • 2003
  • The front-end side members of automobiles absorb most of the energy in a front-end collision. The front-end side members are required to have a high stiffness together with easiness to collapse sequentially to absorb more impact energy. The axial static collapse test (5mm/mim) was conducted by using UTM with respect to the single hat shaped section members which are the standard section shape of the spot welded section members, to the single cap shaped section members, to the double cap shaped section members and to the double hat shaped section members whose section shape are changed in order to give more stiffness. As a result of test, the energy absorbing characteristic was analyzed for different section shapes. That is, it was analyzed that the change of section shape influenced the absorbing energy, the mean collapse load and the maximum collapse load, and that the relation between the change of section shape and the collapse mode.

  • PDF

모터구동 글로브밸브의 Side Flow에 의한 디스크-몸체 마찰부하 평가 (Evaluation of the Disk-to-Body Friction Load by the Side Flow in Motor-Operated Globe Valves)

  • 정래혁;박성근;이도환;송석윤;강신철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.549-554
    • /
    • 2003
  • EPRI PPM (Performance Prediction Methodology), a method used for the prediction of required thrust of valves, can not be applied to unbalanced-disk globe valves operated in the fluid when the fluid temperature is above $150^{\circ}F$ because the thrust increase caused by the friction between the valve disk and body is not considered in the PPM. In order to apply PPM to the valves, EPRI suggested new friction prediction method to be added in the code. This paper analyzes the applicability of the prediction method comparing the disk-to-body friction load predicted from the method with the measured friction load from the field tests. The maximum values from the prediction method and those obtained from the test were 268lbs and about 1500lbs, respectively. It is included that the prediction method should be improved for the realistic prediction of disk-to-body friction load.

  • PDF