• Title/Summary/Keyword: Side step

Search Result 578, Processing Time 0.033 seconds

The Effects of Scapular Stabilization Exercising on Dynamic Standing Balance in Stroke Patients (견갑골 안정화 운동이 뇌졸중 환자의 동적 서기 균형에 미치는 영향)

  • Kim, Goon-Ha;Choe, Han-Seong;Lee, Hyeong-Il;Shin, Hwa-kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • Purpose: We investigate to evaluate the effects of scapular stabilization exercise on dynamic standing balance in stroke patients. Methods: Thirty hemiplegic patients participated was divided into control group and training group randomly. Control group(n=15) had only general rehabilitation training and training group (n=15) had both the general rehabilitation training and intensive scapular stabilization exercise. They were treated for 15minute/5 times/4 week. We measured PALM (palpation meter) to measure affected side's distances from spine to scapular. We measured FRT (functional reach test), FSST (four squared step test), and BPM (balance performance monitering) to evaluate dynamic standing balance. Results: Training group showed a significant difference in the distances from spine to scapular, FRT, FSST, and variables of BPM comparing control group (p<0.05). But control group was not significant difference. Conclusion: These results suggest that scapular stabilization exercises have positive effects on dynamic standing position.

A Study on Input Current Waveform Analysis for Step Up-Down AC-DC Converter of High Power Factor added Electric Isolation (고역률 스텝 업-다운 절연형 AC-DC 컨버터의 입력전류 파형분석에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Choon-Sam;Lee, Bong-Seob;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.34-36
    • /
    • 2008
  • This paper is given a full detail of mathematical analyses of input current for novel active type power factor correction(PFC) AC-DC converter of step up-down added electric isolation. These are compared with harmonics components of input current for a conventional PFC converter of electric isolation type. The proposed PFC converter is constructed in using a new loss-less snubber circuit to achieve a soft switching of control device. Also the proposed converter for discontinuous conduction mode(DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity and the control method is simple. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of a conventional PFC converter. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

  • PDF

Voltage Feedforward Control with Time-Delay Compensation for Grid-Connected Converters

  • Yang, Shude;Tong, Xiangqian
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1833-1842
    • /
    • 2016
  • In grid-connected converter control, grid voltage feedforward is usually introduced to suppress the influence of grid voltage distortion on the converter's grid-side AC current. However, owing to the time-delay in control systems, the suppression effect of the grid voltage distortion is seriously affected. In this paper, the positive effects of the grid voltage feedforward control are analyzed in detail, and the time-delay caused by the low-pass filter (LPF) in the voltage filtering circuits and digital control are summarized. In order to reduce the time-delay effect on the performance of the feedforward control, a voltage feedforward control strategy with time-delay compensation is proposed, in which, a leading correction of the feedforward voltage is used. The optimal leading step used in this strategy is derived from analyzing the phase-frequency characteristics of a LPF and the implementation of digital control. By using the optimal leading step, the delay in the feedforward path can be further counteracted so that the performance of the feedforward control in terms of suppressing the influence of grid voltage distortion on the converter output current can be improved. The validity of the proposed method is verified through simulation and experiment results.

The Clinical Effects of Gamipaimo-tang (Jiaweibeimu-tang) in Asthmatic Patients Based on Severity (가미구모탕의 기관지천식환자의 중증도에 따른 임상효과)

  • 정승기;황우석;이재성;최준용;정희재;이형구
    • The Journal of Korean Medicine
    • /
    • v.24 no.3
    • /
    • pp.155-164
    • /
    • 2003
  • Objective : Recently questionnaires that reflect the quality of life (QOL) in asthma patients were developed. We aimed to identify the clinical effects of Gamipaima-tang and the side effects of Gamipaimo-tang in asthmatic patients. Materials and Methods : The subjects are consisted of 34 patients with asthma who had been treated with Gamipaimo-tang for four weeks. Gamipaima-tang is an herbal decoction which has been used as a traditional therapeutic agent for asthma. Pulmonary function test (PFT) was checked before and after 4-week treatments. Quality of Life Questionnaire for Adult Korean Asthmatics (QLQAKA) was checked before and after 2 weeks and 4 weeks of treatment. Results : Treatment with Gamipaima-tang for four weeks resulted in significant increase in FVC%, $FEV_{1.0}%$, PEFR%, and QLQAKA. The total efficacy rate in the patient group was 52.9% after 4 weeks. The total efficacy rate of the step 4 group (n=18, 55.6%) classified by Global Initiative for Asthma (GINA) was higher than that of the step 3 group (n=13, 46.2%) classified by GINA. Conclusion : This study shows that Gamipaima-tang has the effects of improvement of pulmonary function and quality of life in asthmatic patients. Obviously further research concerning this is still necessary.

  • PDF

A Study on the Evaluation Consulting Methodology of Important Information Communication Base Facility (주요 정보통신기반시설의 평가컨설팅 방법론에 대한 연구)

  • Lee, Young-Ro;Cho, Jae-Wan
    • Journal of Digital Convergence
    • /
    • v.5 no.1
    • /
    • pp.55-68
    • /
    • 2007
  • It soaks but 2001 July information communication base step law enforcement and the Enforcement Ordinance are published to follow, in order to support the establishment of evaluation and protective measure in order the vulnerability analysis against the facility of the agency which manages an important information communication base hour opinion to designate information protection specialty enterprise. As information protection specialty enterprise being revealed evacuation laboratory back 12 enterprises from information communication department become designation as the consulting enterprise and they do an enterprise activity actively. It follows in diffusion of the IT and information reconciliation level the other side where our country belongs in the world-wide first group, the research against the disfunction plan of preparation comparison the fact that law it is come negligently all actuality. The network as it will give management coat fatal effect even at obstacle occurrence hour of instant for of case and IT facility of the cyber transactions which leads, in the future there to be to corporate management, there is a possibility the stable civil official of information Facilities for communications very seeing in the portion which is important. Present condition and important propulsion contents of information communication base step law enforcement after, against a vulnerability analysis of information protection relation field and evaluation consulting methodological application situation to sleep it researches from the dissertation which it sees consequently and it does.

  • PDF

A Study on Input${\cdot}$Output Waveform Solutions and Harmonics Analyses for a Novel PFC Step-up Converter (새로운 PFC 스텝-업 컨버터의 입출력 파형해석 및 고조파분석에 관한 연구)

  • Kwak Dong-Kurl
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.622-628
    • /
    • 2005
  • This paper is given a full detail of mathematical analyses of input current and output voltage for a novel active type power factor correction (PFC) converter. These are compared with harmonics components of input current for a conventional PFC converter. The proposed PFC converter is constructed in using a new loss-less snubber circuit to achieve a soft switching of control device. Also the proposed converter for discontinuous conduction mode (DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity and the control method is simple. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of conventional PFC converter. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

Sequential Formation of Multiple Gap States by Interfacial Reaction between Alq3 and Alkaline-earth Metal

  • Kim, Tae Gun;Kim, Jeong Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.129.2-129.2
    • /
    • 2013
  • Electron injection enhancement at OLED (organic light-emitting diodes) cathode side has mostly been achieved by insertion of a low work function layer between metal electrode and emissive layer. We investigated the interfacial chemical reactions and electronic structures of alkaline-earth metal (Ca, Ba)/Alq3 [tris(8-hydroxyquinolinato)aluminium] and Ca/BaF2/Alq3 using in-situ X-ray & ultraviolet photoelectron spectroscopy. The alkaline-earth metal deposited on Alq3 generates two energetically separated gap states in sequential manner. This phenomenon is explained by step-by-step charge transfer from alkali-earth metal to the lowest unoccupied molecular orbital (LUMO) states of Alq3, forming new occupied states below Fermi level. The BaF2 interlayer initially prevents from direct contact between Alq3 and reactive Ca metal, but it is dissociated into Ba and CaF2. However, as the Ca thickness increases, the Ca penetrates the interlayer to directly participate in the reaction with underlying Alq3. The influence of the multiple gap state formation by the interfacial chemical reaction on the OLED performance will be discussed.

  • PDF

A Study on the Stress Simulation for the Body Design of a PFA-lined Plug Valve (PFA 라이닝 플러그 밸브 설계를 위한 밸브 본체의 응력 시뮬레이션)

  • Kang, Shin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.500-506
    • /
    • 2009
  • This study, is aimed to support the valve design engineer by a CAE simulation on the body of a PFA-lined plug valve, and focuses on static stress analysis, location of the weak point on bending and stiffness of the valve body. To determine whether the valve body can resist being transformed by loads, 1 simulated the stress distribution using CAD/CAE softwares. The 'step' file converted by CAD software after solid modeling is imported to the CAE software. Through simulation procedure, it is shown that the designed-solid-model fur a valve body has stiffness on bending and torsion but has weakness for side bending moment. Also, it is expected that the valve design engineer will understand the basic process of CAE and will be able to apply on his task.

Thermal Behavior Analysis on the Cylinder Block of an Automotive Gasoline Engine (자동차용 가솔린 기관의 실린더 블록에 대한 열적 거동 해석)

  • 손병진;김창헌
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.211-221
    • /
    • 1998
  • Thermal behavior on the cylinder block of a 4-cylinder, 4-stroke 2.0L SOHC gasoline engine was numerically and experimentally analyzed. The numerical calculation was performed using the finite element method. The cylinder block was modelled as a three dimensional finite element by considering its geometry. The physical domain was devided into hexahedron elements. 16 thermocouples were installed at points of 2mm inside from cylinder wall near top ring of piston in cylinder block, which points have suffered major thermal loads and suggested as proper measurement points for engine design by industrial engineers. Under full load and 9$0^{\circ}C$ coolant temperature condition, temperature behavior of cylinder block according to engine speed were analyzed. The results showed that temperature rose gradually to conform to a function of 2nd~4th order of engine speed at intake side, exhaust and siamese side, respectively. As engine load was changed from 100 to 50% by 25% step, temperature curve also conformed to 2nd~7th order function of engine speed. Temperature differences by load condition were similar among 100, 75% and 50%. Under full load and coolant temperature of 11$0^{\circ}C$, temperature behavior were also analyzed and the result also showed conformance to 2n d~7th order function of engine speed. Temperature curve was transferred in parallel upwards corresponding coolant temperature rise.

  • PDF

A Medium-Voltage Matrix Converter Topology for Wind Power Conversion with Medium Frequency Transformers

  • Gu, Chunyang;Krishnamoorthy, Harish S.;Enjeti, Prasad N.;Zheng, Zedong;Li, Yongdong
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1166-1177
    • /
    • 2014
  • A new type of topology with medium-frequency-transformer (MFT) isolation for medium voltage wind power generation systems is proposed in this paper. This type of converter is a high density power conversion system, with high performance features suitable for next generation wind power systems in either on-shore or off-shore applications. The proposed topology employs single-phase cascaded multi-level AC-AC converters on the grid side and three phase matrix converters on the generator side, which are interfaced by medium frequency transformers. This avoids DC-Link electrolytic capacitors and/or resonant L-C components in the power flow path thereby improving the power density and system reliability. Several configurations are given to fit different applications. The modulation and control strategy has been detailed. As two important part of the whole system, a novel single phase AC-AC converter topology with its reliable six-step switching technique and a novel symmetrical 11-segment modulation strategy for two stage matrix converter (TSMC) is proposed at the special situation of medium frequency chopping. The validity of the proposed concept has been verified by simulation results and experiment waveforms from a scaled down laboratory prototype.