• Title/Summary/Keyword: Side Jet

Search Result 135, Processing Time 0.025 seconds

Rotary Veneer Peeling of Some Softwoods and Its Veneer Drying (수종(數種)의 침엽수재(針葉樹材)의 로타리 단판(單板) 절삭(切削)과 건조(乾燥))

  • Jung, Hee-Suk;Lee, Nam-Ho;Yeo, Hwan-Myeong;Lee, June-Ho;Yoo, Tae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.34-47
    • /
    • 1996
  • Veneers of two nominal thicknesses, 1.5 and 2.5mm, were rotary peeled from Japanese larch (Larix leptolepis). Dahurian larch (Larix gmelinei) and Radiata pine (Pinus radiata) bolts unheated and heated in the water vat temperature of $66^{\circ}C$ by rising a final temperature at 10cm core of $60^{\circ}C$ to remain core diameter of 11.4cm. 1.5 and 2.5mm thick veneer cut from the heated Japanese larch were significantly thinner than those of the unheated bolt and 2.5mm thick veneer cut from the heated Dahurian larch were significantly thicker than that of the unheated bolt. 1.5mm thick Dahurian larch veneer and 1.5 and 2.5mm thick Radiata pine veneers showed insignificant difference between the unheated and heated bolts, respectively. Check distance on the loose side of 1.5mm thick veneer cut from the heated Radiata pine was significantly wider than that of the unheated bolt. However check distances on the loose side of 1.5 and 2.5mm thick Japanese larch and Dahurian larch veneers and 2.5mm thick Radiata pine veneers showed insignificant difference between the unheated and heated bolts. Also the depth of check on the loose side of three species showed insignificantly difference between the unheated and heated bolts. Arithmatic mean deviation($R_a$) and maximum height($R_{max}$) of the profile on the loose side of dried veneer by preheating the bolt compared with unheated bolts were different among apecies and between veneer thickness. The preheating treatment slightly affected qualities of these thin veneers such as 1.5 and 2.5mm. The yield of 2.5mm thick veneer from the heated radiata pine was significantly higher than that of the unheated bolt. However the yield of 2.5mm thick veneer for other two species and 1.5mm thick veneer for three species showed insignificant difference between the unheated and heated bolts. The yield of 2.5mm thick veneer for three species were higher than those of 1.5mm thick veneer. The average yields of green veneer of Japanese larch. Dahurian larch and Radiata pine were 57.1, 55.1 and 54.0 percent, respectively. Variables such as initial MC. drying time and veneer thickness had strong effect for Japanese larch veneer, less effect for Radiata pine veneer and nuch less effect on final MC for Dahurian larch veneer in jet drying. Correlation between the current MC and the drying time of Dahurian larch with low variation of initial MC was higher than those of Japanese larch and Radiata pine veneer with high variation of initial MC in high temperature drying. Thickness shrinkages of 2.5mm thick veneer for Japanese larch and Radiata pine were higher than those of 1.5mm thick veneers, but shrinkages of Dahurian larch veneer were similar between two nominal veneer thicknesses.

  • PDF

Methoxychlor Produces Many Adverse Effects on Male Reproductive System, Kidney and Liver by Binding to Oestrogen Receptors

  • Kim, Dae Young
    • Journal of Embryo Transfer
    • /
    • v.28 no.2
    • /
    • pp.157-162
    • /
    • 2013
  • Methoxychlor (MXC) was developed to be a replacement for the banned pesticide DDT. HPTE [2,2-bis (p-hydroxyphenyl)-1,1,1-trichloroethane], which is an in vivo metabolite of MXC, has strong oestrogenic and anti-androgenic effects. MXC and HPTE are thought to produce potentially adverse effects by acting through oestrogen and androgen receptors. Of the two, HPTE binds to sex-steroid receptors with greater affinity, and it inhibits testosterone biosynthesis in Leydig cells by inhibiting cholesterol side-chain cleavage enzyme activity and cholesterol utilisation. In a previous study, MXC was shown to induce Leydig cell apoptosis by decreasing testosterone concentrations. I focused on the effects of MXC on male mice that resulted from interactions with sex-steroid hormone receptors. Sex-steroid hormones affect other organs including the kidney and liver. Accordingly, I hypothesised that MXC can act through sex-steroid receptors to produce adverse effects on the testis, kidney and liver, and I designed our experiments to confirm the different effects of MXC exposure on the male reproductive system, kidney and liver. In these experiments, I used pre-pubescent ICR mice; the puberty period in ICR mice is from postnatal day (PND) 45 to PND60. I treated the experimental group with 0, 100, 200, 400 mg MXC/kg b.w. delivered by an intra-peritoneal injection with sesame oil used as vehicle for 4 weeks. At the end of the experiment, the mice were sacrificed under anaesthesia. The testes and accessory reproductive organs were collected, weighed and prepared for histological investigation. I performed a chemiluminescence immune assay to observe the serum levels of testosterone, LH and FSH. Blood biochemical determination was also performed to check for other effects. There were no significant differences in our histological observations or relative organ weights. Serum testosterone levels were decreased in a dose-dependent manner; a greater dose resulted in the production of less testosterone. Compared to the control group, testosterone concentrations differed in the 200 and 400 mg/kg dosage groups. In conclusion, I observed markedly negative effects of MXC exposure on testosterone concentrations in pre-pubescent male mice. From our biochemical determinations, I observed some changes that indicate renal and hepatic failure. Together, these data suggest that MXC produces adverse effects on the reproductive system, kidney and liver.

The Study on Automatic Temperature Transmission System for the Heating pipe at Home (가정식난방배수관내의자동온도송신장치에대한연구)

  • Park, Chul-Min;Jo, Heung-Kuk;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2641-2646
    • /
    • 2009
  • The more growing on home automation system at automatic control, the more efficiency required for energy consumption and for recycling energy in near future. Heating is essential in general apartment. Heating method is two types in apartment. One uses electricity, and other one uses warm water. If use electricity, is not efficient by rise of electric charges. But, It can reduce much in expense aspect, if use warm water. When use warm water, temperature of warm water is not equal from all pipe parts. Therefore, indoor tempera can be unequal with set point. Solution of these problems is as following. Temperature sensor in warm water attach pipe. The measured temperature transmits by real time. Temperature of warm water controls in receiver side. In this paper, we propose an automatic temperature transmission system for the heating pipe at home, that is a low-power based, and supply the energy source from a small AC motor resided in bottom cement mortal. The proposed system is used in power mechanism from a collision process of water-jet using propeller water-difference and also designed a CPU module by Atmega8 at ATMEL co., Inc. and a communication module by CC1020 at Chipcon co., Inc.

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

Histamine Bronchial Provocation Test -Timed Tidal Breathing Technique- (히스타민 기관지유발 검사 -일정시간 흡입법-)

  • Chung, Yeon-Tae;Won, Kyung-Sook;Park, Hae-Shim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.270-276
    • /
    • 1994
  • Background: The measurement of nonspecific bronchial hyperreactivity is valuable for diagnosis and management of bronchial asthma. Methacholine or histamine is used for the pharmacologic provocation test. Usually a methacholine bronchial provocation test is performed by a dosing technique with counted number of breaths. A dosimeter is indispensable in the dosing technique. Recently a timed tidal breathing technique which dose not need an expensive dosimeter was introduced. We measured the degree of nonspecific bronchial hyperreactivity to histamine using a simple timed tidal breathing technique. Method: Forty two healthy volunteers, 12 patients with bronchial asthma(BA), 10 patients with rhinitis(RH) and 10 patients with upper respiratory infection(URI) participated in the study. The subject's nose was clipped and inhalation continued during tidal breathing for 2 minutes via a face mask. $FEV_1$ was measured at 30 seconds, 90 seconds after inhalation and inhalation of next solution was continued until there was a fall in $FEV_1$ of 20%. Histamine PC20 was defined as the concentration at 20% fall of $FEV_1$ and it was obtained from the log dose-response curve by linear interpolation. Results: Inhalation of serial dilution of histamine could be performed in all patients without significant side effects. The geometric mean${\pm}$standard deviation of histamine PC20 in healthy volunteers is $8.27{\pm}2.22mg/ml$, BA group $0.33{\pm}3.02mg/ml$, RH group $0.85{\pm}3.24mg/ml$, and URI group $1.47{\pm}1.98mg/ml$. Conclusion: Histamine bronchial provocation test using timed tidal breath method is a simple and suitable tool for management of patients with bronchial hyperreactivity.

  • PDF