• Title/Summary/Keyword: SiPMs

Search Result 22, Processing Time 0.018 seconds

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

Chemical Properties and Source Profiles of Particulate Matter Collected on an Underground Subway Platform

  • Ma, Chang-Jin;Lee, Kyoung-Bin;Kim, Shin-Do;Sera, Koichiro
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.165-172
    • /
    • 2015
  • Under a very tough situation that there has been increasing concern to the air quality in underground subway spaces, this study set sights on the thorough estimation of the chemical properties and source apportionment of particulate matter (PM) collected on an underground subway platform by a cooperative approach of semi-bulk and single particle analyses. The size-resolved PMs were intensively collected on the platform of Miasageori station on the Seoul Subway Line-4, and then, they were semibulkily analyzed by a PIXE and the TOR$^{(R)}$ method, and individually analyzed by a SEM-EDX. Overwhelmingly enriched iron was a notable feature of elemental concentration of $PM_{2.5}$. Source classification of iron in $PM_{10-2.5}$ and $PM_{2.5}$ performed along with their elemental concentrations, indicates that the railway originated iron accounts for 95.71% and 66.39% of total iron in $PM_{10-2.5}$ and $PM_{2.5}$, respectively. Via a stoichiometric categorization, $Fe_2O_3$, $CaAl_2Si_2O_8$, $Al_2O_3$, and $CaCO_3$ show more than 85% abundance ratio in individual coarse particles. The result of theoretical estimation of the subway derived organic carbon ($OC_{Subway}$) suggests that $OC_{Subway}$ in $PM_1$ and $PM_{2.5-1}$ account for 75.86% and 51.88% of total organic carbon, respectively.