• Title/Summary/Keyword: SiPM

Search Result 856, Processing Time 0.028 seconds

Nutrition Intake according to Food and Exercise Habits in Female College Students of Yang-Ju si (경기도 양주시 여대생의 식습관, 운동습관, 건강관련행동이 영양섭취수준에 미치는 영향)

  • Rha, Young Ah;Kang, Min Jeong;Lee, Sun Ho;Kim, Jung Yun
    • Culinary science and hospitality research
    • /
    • v.21 no.4
    • /
    • pp.284-293
    • /
    • 2015
  • This study was intended to investigate food, exercise habits, perception of health status and the effects of nutrient intake of female college students. Food habits such as regularity of meal time, repast of breakfast, numbers of night snack per week and duration of meal were assessed via a self reporting questionnaire, and 24hrs recall method for nutrient intake was obtained from 155 female college students in Yangju-si. The mean height and weight of the subjects were $161.25{\pm}3.52cm$ and $52.26{\pm}4.52kg$, respectively. The average intakes of energy and nutrients were below the Korea recommended dietary allowance(RDA). Especially, The nutrient intakes(energy, protein, fat, fiber, calcium, iron, phosphorus, zinc, sodium, potassium, vitamin B6, niacin, vitamin C, folate, vitamin E, cholesterol) of the group in which the regularity of meal time per week was 5~7 days was significantly higher than the group in which the regularity of meal time was < 3 days (p<0.005). The nutrient intakes influenced by the food habit such as the regularity of meal time, skipping breakfast, and the numbers of night snack per week but did not differ in accordance with the regular exercise habits and perception of health status. These findings suggest that nutritional education based on female college students' food habits(regularity of meal time, skipping breakfast and night snacks per week, and duration of meal) may be required to improve dietary variety. It is considered that the improvement in dietary habits will contribute to the improvement of nutrition.

Aqueous Spray-dried Green Tea Extract Regulates Body Weight and Epididymal Fat Accumulation in Mice (열수 녹차추출물이 생쥐의 체중 및 부고환 지방축적 조절에 미치는 영향)

  • Park, Pil-Joon;Kim, Chae-Wook;Cho, Si-Young;Rha, Chan-Su;Seo, Dae-Bang;Lee, Sang-Jun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.103-108
    • /
    • 2010
  • To obtain the best yield of the beneficial ingredients in green tea, such as catechins, green tea powder is most often prepared by ethyl alcohol extraction. However, the taste, cost and composition of ethyl alcohol extract is different from aqueous spray-dried green tea extract (aq-GTE). Specifically, aq-GTE has a better flavor, lower production costs and higher purity when compared to ethyl alcohol extract. In this study, we elucidated the effect of aq-GTE on diet-induced obesity in male C57BL/6J mice following dose-dependent oral administration of aq-GTE. After eight weeks, the body weight was reduced by 13-17% in mice fed 200 mg/kg bw aq-GTE ($12.468{\pm}0.45\;g$; p<0.05) and 20-25% in mice fed 400 mg/kg bw aq-GTE ($11.259{\pm}0.61\;g$; p<0.05) when compared with the high-fat diet (HFD) control group mice ($14.714{\pm}0.95\;g$; p<0.05). The correlation between epididymal fat accumulation and body weight also decreased by approximately 26.6% (p<0.05) in mice fed a HFD with aq-GTE 400 mg/kg bw. Finally, serum parameters such as the triglyceride, glucose and cholesterol levels in the HFD groups were reduced by the aq-GTE 400 mg/kg bw diet. Analysis on glutamic-pyruvic transaminase, blood urea nitrogen and development of hepatic steatosis revealed no histologic evidence of hepatotoxicity in HFD mice fed aq-GTE. Overall, our results imply that aq-GTE is able to regulate body weight and fat accumulation in mice.

Studies on the Dietary Fiber of Brown Rice and Milled Rice (현미와 백미의 식이섬유에 관한 연구)

  • Lee, Hee-Ja;Byun, Si-Myung;Kim, Hyong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.576-584
    • /
    • 1988
  • Neutral detergent fiber(NDF) were extracted from the Nampung, Milyang #23, Whasung and Jinhung varieties of rice by neutral detergent fiber method. To determine the properties of NDF three factors were measured : water-binding capacity(WBC), Fe-binding capacity and sodium taurocholate binding with NDF. The average WBC of NDF was $5.60{\pm}0.87gH_2O/g$ NDF, and the average Fe-binding capacity ranged from 24.63% at pH 5.0 to 19.6% at pH 6.0 and 48.98% at pH 7.0. Binding of sodium taurocholate with NDF was determined in vitro using C-14 labeled sodium taurocholate at 100M sodium taurocholate concentrations. NDF binding of Jinhung was 27.87 while Nampung, Milyang #23 and Whasung measured 32% each. When sodium taurocholate concentrations were raised from $40{\mu}M\;to\;240{\mu}M$ the tendency of binding increased as the concentrations increased, but not linearly.

  • PDF

Establishment of a Single Dose Radiation Model of Oral Mucositis in Mice (일회 방사선조사를 이용한 마우스 구강점막염 모델의 확립)

  • Ryu, Seung-Hee;Moon, Soo-Young;Choi, Eun-Kyung;Kim, Jong-Hoon;Ahn, Seung-Do;Song, Si-Yeol;Park, Jin-Hong;Noh, Young-Ju;Lee, Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.257-262
    • /
    • 2008
  • Purpose: Oral mucositis induced by radiotherapy to the head and neck area, is a common acute complication and is considered as the most severe symptom for cancer patients in the early stages of treatment. This study was proposed to establish the oral mucositis mouse model induced by a single dose of radiation for the facility of testing therapeutic candidates which can be used for the oral mucositis treatments. Materials and Methods: Fifty-five BALB/c mice were divided into four groups: control, 16 Gy, 18 Gy, and 20 Gy. Oral mucositis was induced by a single dose of radiation to the head and neck using 6 MV x-Ray from linear accelerator. After irradiation, body weight and physical abnormalities were checked daily. Tongue tissues from all groups were taken on days 1, 2, 3, 5, 7, 9, and 14, respectively and H&E staining was conducted to examine morphological changes. Results: Body weight dramatically decreased after day 5 in all irradiated mice. In the 16 Gy treatment group, body weight was recovered on day 14. The histology data showed that the thickness of the epithelial cell layer was decreased by the accumulated time after radiation treatment, up to day 9. Severe ulceration was revealed on day 9. Conclusion: A single dose of 16 Gy is sufficient dose to induce oral mucositis in Balb/C mice. Significant changes were observed in the Balb/C mice on days 7 and 9 after radiation. It is suggested that this mouse model might be a useful standard tool for studying oral mucositis induced by radiation.

Early Results of Aortic Valve-sparing Procedures in Patients with Annuloaortic Ectasia (대동맥륜대동맥확장(Annuloaortic Ectasia) 환자에서 대동맥판막을 보존하면서 시행된 대동맥근부 및 상행대동맥 치환술의 단기 성적)

  • Sung Kiick;Park Kay-Hyun;Lee Young Tak;Jun Tae-Gook;Yang Ji-Hyuk;Kim Su Wan;Kim Jin Sun;Cho Sung Woo;Kim Si Wook;Choi Jin Ho;Park Pyo Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.483-488
    • /
    • 2005
  • Aortic valve-sparing procedures could reduce valve-related morbidity, but may increase operative risks; therefore, these procedures could not be performed routinely. We attempted to find out the early results while focusing on the operative risks associated with these procedures in our hospital. Material and Method: From May 1996 to July 2003, 26 patients underwent these procedures including 15 patients with Marfan syndrome and 1 patient with Behcet disease. There were 17 men and 9 women with mean age of $37.9\pm19.2$ years (range: 6 months-74 years). Ten patients had ascending aortic dissection, 18 patients had more than moderate degree of aortic valve insufficiency (AI). Two types of valve-sparing procedures were performed: valve reimplantation in 14 and root remodeling in 12 patients. Associated procedures were performed as follows: aortic valve plasty in 6, mitral valve plasty in 5, hemi-arch replacement in 4, total arch replacement in 2, coronary artery bypass surgery in 1 and Maze procedure in 1 patient(s). Result: In four patients, valve-sparing procedures were converted to Bentall procedures during operation. Including these patients, there was no operative deaths, 3 patients underwent re-operation due to bleeding, 1 patient had permanent pacemaker. The median duration of ICU stay was 45.5 hours, the median duration of hospital stay was 10.5 days. In 22 patients excluding 4 converted patients, intraoperative transesophageal echocardiogram (TEE) showed less than mild degree of AI in all except one who had not received intra-operative TEE in the beginning and showed moderate degree of AI at discharge. The mean duration of follow-up was $21.2\pm27.4$ months. All patients were alive except one who died during other departmental surgery. In 3 patients, more than moderate degree of AI was recurred, but there were no reoperation. Conclusion: Aortic valve-sparing procedures could be performed relatively safely in selected patients who had annuloaortic ectasia.

Continuous Positive Airway Pressure during Bronchoalveolar Lavage in Patients with Severe Hypoxemia (심한 저산소혈증 환자에서 기관지폐포세척술 시 안면마스크를 이용한 지속성 기도양압의 유용성)

  • An, Chang Hyeok;Lim, Sung Yong;Suh, Gee Young;Park, Gye Young;Park, Jung Woong;Jeong, Seong Hwan;Lim, Si Young;Oui, Misook;Koh, Won-Jung;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.1
    • /
    • pp.71-79
    • /
    • 2003
  • Background : A bronchoalveolar lavage(BAL) is useful in diagnosing the etiology of bilateral pulmonary infiltrations, but may worsen the oxygenation and clinical status in severely hypoxemic patients. This study assessed the safety and efficacy of the continuous positive airway pressure(CPAP) using a conventional mechanical ventilator via a face mask as a tool for maintaining the oxygenation level during BAL. Methods : Seven consecutive patients with the bilateral pulmonary infiltrates and severe hypoxemia ($PaO_2/FIO_2$ ratio ${\leq}200$ on oxygen 10 L/min via mask with reservoir bag) were enrolled. The CPAP 5-6 $cmH_2O(F_IO_2\;1.0)$ was delivered through an inflatable face mask using a conventional mechanical ventilator. The CPAP began 10 min before starting the BAL and continued for 30 min after the procedure was completed. A bronchoscope was passed through a T-adapter and advanced through the mouth. BAL was performed using the conventional method. The vital signs, pulse oxymetry values, and arterial blood gases were monitored during the study. Results : (1) Median age was 56 years(male:female=4:3). (2) The baseline $PaO_2$ was $78{\pm}16mmHg$, which increased significantly to $269{\pm}116mmHg$(p=0.018) with CPAP. After the BAL, the $PaO_2$ did not decrease significantly but returned to the baseline level after the CPAP was discontinued. The $SpO_2$ showed a similar trend with the $PaO_2$ and did not decrease to below 90 % during the duration of the study. (3) The $PaCO_2$ increased and the pH decreased significantly after the BAL but returned to the baseline level within 30 min after the BAL. (5) No complications directly related to the BAL procedure were encountered. However, intubation was necessary in 3 patients(43 %) due to the progression of the underlying diseases. Conclusion : In severe hypoxemic patients, CPAP using a face mask and conventional mechanical ventilator during a BAL might allow minimal alterations in oxygenation and prevent subsequent respiratory failure.

Patient Satisfaction with Cancer Pain Management (암성통증관리 만족도)

  • Lee, So-Woo;Kim, Si-Young;Hong, Young-Seon;Kim, Eun-Kyung;Kim, Hyun-Sook
    • Journal of Hospice and Palliative Care
    • /
    • v.6 no.1
    • /
    • pp.22-33
    • /
    • 2003
  • Purpose : The purpose of this study was to evaluate the present status of patients' satisfaction and the reasons for any satisfaction or dissatisfaction in cancer pain management Methods : A cross-sectional survey was used to obtain the feedback about pain management. The results of the survey were collected from 59 in- or out-patient who had cancer treatment at two of the teaching hospitals in Seoul from July, 2002 to November, 2002. The data was obtained by a structured questionnaire based on the American Cancer Society Patient Outcome Questionnaire(APS-POQ) and other previous research. The clinical information for all patients were compiled by reviewing their medical records. Resuts : 1) The subjects' mean score of the worst pain was 6.77, the average pain score was 3.80, and the pain score after management was 2.93 for the past 24 hours. The mean score of total pain interference was $25.03{\pm}12.82$. Many of the subjects had false beliefs about pain such as 'the experience of pain is a sign that the illness has gotten worse', 'pain medicine should be 'saved' in case the pain gets worse' and 'people get addicted to pain medicine easily'. 2) 66.1% of the subjects were properly medicated with analgesics. 33.9% of the subjects reported use of various methods in controlling pain other than the prescribed medication. Only 33.9% of the subjects had a chance to be educated about pain management by doctors or nurses. 3) The mean score of patients' satisfaction with pain management was $4.19{\pm}1.14$. 72.9% of the subjects answered 'satisfied' with pain management. The reasons for dissatisfaction were 'the pain was not relieved even after the pain management', 'I was not quickly and promptly treated when I complained of pain', 'doctors and nurses didn't pay much attention to my complaints of pain.', and 'there was no appropriate information given on the methods of administration, effect duration and side effects of pain medicine.' The reasons for satisfaction were: 'the pain was relieved after the pain management.', 'doctors and nurses quickly and promptly controlled my pain.', 'doctors and nurses paid enough attention to my complaints of pain.' and 'trust in my physician'. 4) In pain severity or pain interference, no significant difference was found between the satisfied group and dissatisfied group. On the belief 'good patients avoid talking about pain', a significant difference was found between the satisfied group and dissatisfied group. Conclusions : The patients' satisfaction with cancer pain management has increased over the years but still about 30% of patients reported to be 'not satisfied' for various reasons. The results of this study suggest that patients' education should be done to improve satisfaction in the pain management program.

  • PDF

Plasma Etching Process based on Real-time Monitoring of Radical Density and Substrate Temperature

  • Takeda, K.;Fukunaga, Y.;Tsutsumi, T.;Ishikawa, K.;Kondo, H.;Sekine, M.;Hori, M.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.93-93
    • /
    • 2016
  • Large scale integrated circuits (LSIs) has been improved by the shrinkage of the circuit dimensions. The smaller chip sizes and increase in circuit density require the miniaturization of the line-width and space between metal interconnections. Therefore, an extreme precise control of the critical dimension and pattern profile is necessary to fabricate next generation nano-electronics devices. The pattern profile control of plasma etching with an accuracy of sub-nanometer must be achieved. To realize the etching process which achieves the problem, understanding of the etching mechanism and precise control of the process based on the real-time monitoring of internal plasma parameters such as etching species density, surface temperature of substrate, etc. are very important. For instance, it is known that the etched profiles of organic low dielectric (low-k) films are sensitive to the substrate temperature and density ratio of H and N atoms in the H2/N2 plasma [1]. In this study, we introduced a feedback control of actual substrate temperature and radical density ratio monitored in real time. And then the dependence of etch rates and profiles of organic films have been evaluated based on the substrate temperatures. In this study, organic low-k films were etched by a dual frequency capacitively coupled plasma employing the mixture of H2/N2 gases. A 100-MHz power was supplied to an upper electrode for plasma generation. The Si substrate was electrostatically chucked to a lower electrode biased by supplying a 2-MHz power. To investigate the effects of H and N radical on the etching profile of organic low-k films, absolute H and N atom densities were measured by vacuum ultraviolet absorption spectroscopy [2]. Moreover, using the optical fiber-type low-coherence interferometer [3], substrate temperature has been measured in real time during etching process. From the measurement results, the temperature raised rapidly just after plasma ignition and was gradually saturated. The temporal change of substrate temperature is a crucial issue to control of surface reactions of reactive species. Therefore, by the intervals of on-off of the plasma discharge, the substrate temperature was maintained within ${\pm}1.5^{\circ}C$ from the set value. As a result, the temperatures were kept within $3^{\circ}C$ during the etching process. Then, we etched organic films with line-and-space pattern using this system. The cross-sections of the organic films etched for 50 s with the substrate temperatures at $20^{\circ}C$ and $100^{\circ}C$ were observed by SEM. From the results, they were different in the sidewall profile. It suggests that the reactions on the sidewalls changed according to the substrate temperature. The precise substrate temperature control method with real-time temperature monitoring and intermittent plasma generation was suggested to contribute on realization of fine pattern etching.

  • PDF

마그네트론 스퍼터링법을 이용하여 증착한 Sn doped IZO 박막의 열전 특성

  • Byeon, Ja-Yeong;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.253-253
    • /
    • 2016
  • 최근 세계적으로 대체 에너지는 중요한 이슈가 되고 있으며 그 중 열전 재료는 유망한 에너지 기술로서 주목 받고 있다. 특히 고 직접화 전자 소자의 발열 문제를 해결하기 위해, 소형화와 정밀 온도 제어가 가능한 박막형 열전 소자에 연구가 주목 받고 있다. 박막형 열전소자 중 산화물 반도체계에 대한 연구가 활발히 진행되고 있으며, 이러한 산화물 반도체계 중 In2O3는 BiTe, PbTe 등의 기존의 재료에 비해 독성이 낮을 뿐만 아니라 내 산화성 및 고온에서 열적 안정성이 우수하여 고온에서 적용 불가능한 금속계 열전 재료의 한계를 극복 할 수 있다는 장점을 가진다. 우수한 성능 가장 낮은 캐리어 밀도를 가지기 때문에 의 열전 재료는 높은 전기 전도도 및 제백 계수 그리고 낮은 열전도도 특성을 가져야만 한다. IZO:Sn(Zn 10 wt.%, Sn 800 ppm) 박막의 경우, 높은 전기 전도성을 가지면서 비정질 구조를 가진다. 이와 같이 비정질 구조를 가지는 박막 열전 재료는 격자에 의한 열 전도도가 낮기 때문에 결정질 구조에 비해 전체 열 전도도 값이 낮을 것으로 기대된다. 따라서 높은 전기 전도도를 가지면서 동시에 낮은 열 전도도를 가지게 되어 우수한 열전 특성을 가질 것이라 예상된다. 이러한 특성을 바탕으로 본 연구에서는 비정질 구조를 갖는 Zn와 미량의 Sn을 동시에 첨가한 In2O3박막의 전기적 특성및 열전 특성을 관찰하고자 한다. 본 연구에서는 magnetron sputtering법으로 IZO:Sn(Zn 10 wt.%, Sn 800 ppm) 타깃을 이용하여 기판 가열없이 DC Power 70 W, 작업 압력 0.7 Pa으로 SiO2 기판 위에 $400{\pm}20nm$ 두께의 박막을 증착하였다. 이러한 공정으로 만들어진 박막은 대기 중 후 열처리를 각각의 200, 300, 400, 500, $600^{\circ}C$ 온도에서 진행하였다. 박막의 미세 구조는 XRD를 통해 관찰하였다. 그리고 박막의 전기적 특성은 Hall effect measurement을 통해 측정하였고, 열전 특성은 Seebeck 상수의 측정을 통하여 평가하였다. XRD 확인 결과 RT에서 증착한 박막과 후 열처리 200, 300, 400, $500^{\circ}C$ 결과 비정질 구조를 보였고, 후열처리 $600^{\circ}C$에서는 결정의 회절 피크를 보였다. 전기적 특성의 경우, 후 열처리 온도가 증가함에 따라 전기 전도도는 감소한다. 이는 공기중의 산소가 박막에 침투하여 oxygen vacancy를 막아 캐리어 밀도가 감소한것에 기인 된 것으로 판단된다. 열전 특성의 경우 제백상수는 후 열처리 $600^{\circ}C$에서 가장 높은 제백상수를 나타낸다. 제백 상수는 수식에 따라 캐리어 밀도의 -2/3승에 비례하게 된다. 수식에 따라 후 열처리 $600^{\circ}C$에서 가장 낮은 캐리어 밀도를 가지기 때문에 가장 높은 제백 상수를 가지게 된다. 열전 성능 척도인 Power factor는 제백 상수의 제곱과 전기전도도의 곱으로 나타내는데, 후 열처리 $200^{\circ}C$에서 가장 높은 Power factor를 보인다. 이는 캐리어 밀도 감소에 따라 전기 전도도는 감소하였지만 이로 인해 제백상수는 증가하였고, 또한 캐리어 밀도 감소에 따라 이온화 불순물 산란의 감소에 의해 이동도의 증가에 의한 것으로 판단된다. 박막의 경우 기판의 영향으로 인해 열 전도도 측정이 어려워 열전 성능 지수(ZT)를 계산을 할 수 없지만, 마그네트론 스퍼터링법으로 증착한 IZO:Sn 박막은 비정질 구조를 가지므로 격자진동에 의한 열 전도도가 낮아 전체 열 전도도가 결정질에 비해 낮을 것이며 이는 높은 열전 성능 지수를 가질 것으로 예상된다.

  • PDF

Irradiation enduced In-plane magnetization in Fe/MgO/Fe/Co multilayers

  • Singh, Jitendra Pal;Lim, Weon Cheol;Song, Jonghan;Kim, Jaeyeoul;Asokan, K.;Chae, Keun Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.188.1-188.1
    • /
    • 2015
  • For present investigation Fe/MgO/Fe/Co multilayer stack is grown on Si substrate using e-beam evaporation in ultrahigh vacuum. This stack is irradiated perpendicularly by 120 MeV $Ag^{8+}$ at different fluences ranging from $1{\times}10^{11}$ to $1{\times}10^{13}ions/cm^2$ in high vacuum using 15UD Pelletron Accelerator at Inter University Accelerator Centre, New Delhi. Magnetic measurements carried out on pre and post irradiated stacks show significant changes in the shape of perpendicular hysteresis which is relevant with previous observation of re-orientation of magnetic moment along the direction of ion trajectory. However increase in plane squareness may be due to the modification of interface structure of stacks. X-ray reflectivity measurements show onset of interface roughness and interface mixing. X-ray diffraction measurements carried out using synchrotron radiation shows amorphous nature of MgO and Co layer in the stack. Peak corresponding body centered Fe [JCPDS-06-0696] is observed in X-ray diffraction pattern of pre and post irradiated stacks. Peak broadening shows granular nature of Fe layer. Estimated crystallite size is $22{\pm}1nm$ for pre-irradiated stack. Crystallite size first increases with irradiation then decreases. Structural quality of these stacks was further studied using transmission electron microscopic measurements. Thickness from these measurements are 54, 36, 23, 58 and 3 nm respectively for MgO, Fe, MgO, Fe+Co and Au layers in the stack. These measurements envisage poor crystallinity of different layers. Interfaces are not clear which indicate mixing at interface. With increase fluence mixing and diffusion was increased in the stack. X-ray absorption spectroscopic measurements carried out on these stacks show changes of Fe valence state after irradiation along with change of O(2p)-metal (3d) hybridized state. Valence state change predicts oxide formation at interface which causes enhanced in-plane magnetization.

  • PDF