• Title/Summary/Keyword: SiPM

Search Result 855, Processing Time 0.032 seconds

Comparison of Metal Contents in Respirable Particulate Mass by Particle Size and Season in Seoul and Asan City (서울.아산지역 호흡성먼지의 금속함량에 관한 연구)

  • Choi, Yun-Na;Jeon, Yong-Taek;Jang, Bong-Ki;Yang, Won-Ho;Yom, Yoon-Ki;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.1
    • /
    • pp.33-48
    • /
    • 2008
  • The purpose of this study was to characterize background mass concentration of $PM_{10},\;PM_{2.5}$ and metallic composition from June 2004 to June 2005 in comparison with Seoul and Asan city. The results were as follows: 1. Annual mean of $PM_{10}$ concentrations in Seoul and Asan were $56.95({\pm}25.63){\mu}g/m^3,\;57.02({\pm}27.22){\mu}g/m^3$ respectly. 2. Annual mean of $PM_{2.5}$ concentrations in Seoul and Asan were $46.97({\pm}40.36){\mu}g/m^3,\;42.16({\pm}21.79){\mu}g/m^3$ respectly. 3. The average $PM_{2.5}/PM_{10}$ ratio was 0.82 in Seoul and 0.74 in Asan city. 4. The concentration of $PM_{10},\;PM_{2.5}$ were the highest in spring and the lowest in summer. Asan was higher than Seoul in spring and summer. 5. The results showed that average $PM_{10}$ composition order as Si>Fe>Pb>Zn>Mn in Seoul and Si>Fe>Zn>Pb>Mn in Asan. The concentration of metals in $PM_{10}$ of Seoul that Cr, Cu, Fe, Mn were high in spring and Zn was low in Fall. Fe, Mn were high in spring of Asan. 6. The results showed that average $PM_{2.5}$ composition order as Si>Pb>Fe>Zn>Mn in Seoul and Si>Fe>Pb>Zn>Cr in Asan. The concentration of metals in $PM_{2.5}$ of Seoul that Cr was high in spring. 7. The result showed that relation between Cr and Cu, Cu and Fe, Fe and Mn, Mn and Zn, Zn and Si in Seoul, Cr and Zn, Cu and Pb, Zn and Pb, Pb and Mn in Asan. The result showed that $PM_{10}$ concentration exceeding $50{\mu}g/m^3$(US-EPA Standard) and $PM_{2.5}$ concentration exceeding $15{\mu}g/m^3$(US-EPA Standard). In urban area, the monitoring of $PM_{2.5}$ permits the anthropogenic sources and the interference of natural sources with respect to $PM_{10}$ measurements.

The Characterization of PM, PM10, and PM2.5 from Stationary Sources (고정배출원의 먼지 크기별 (PM, PM10, PM2.5) 배출 특성 연구)

  • Kim, JongHo;Hwang, InJo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.6
    • /
    • pp.603-612
    • /
    • 2016
  • The objective of this study was to estimate the emission characteristics for PM, $PM_{10}$, and $PM_{2.5}$ in the various stationary sources. The particulate matters collected in the various stationary sources such as power plants (Coal and B-C oil), incinerators(municipal and industrial waste), and glass furnaces. The PM and $PM_{10}$, PM and $PM_{2.5}$, $PM_{10}$ and $PM_{2.5}$ samples were collected using the cyclone type $PM_{10}$, $PM_{2.5}$ samplers and 30 species(19 inorganic species, 9 ionic species, OC and EC) were analyzed by ICP, IC, and TOR/IMPROVE methods. The mass concentrations of PM, $PM_{10}$, $PM_{2.5}$ from nine stationary sources ranged $0.63{\sim}9.58mg/Sm^3$, $0.26{\sim}7.47mg/Sm^3$ and $0.13{\sim}6.34mg/Sm^3$, respectively. The level of $PM_{10}$, $PM_{2.5}$ portion in PM calculated 0.63~0.99, 0.38~0.94, respectively. In the case of emission trend for species, power plant showed high concentrations for Al, Mg, Na, Si, V and $SO_4{^{2-}}$, respectively. Also, Ca, Fe, K, Si, $Cl^-$, and $K^+$ showed high in incinerator. In the case of glass furnace, Na, Pb, K, Si, $Na^+$ and $SO_4{^{2-}}$ represented high concentrations. Power plant showed higher EC/OC concentrations than other sampling sites. These results suggest the possible role for complement establishment process of emission inventory and emission management for PM.

Development of PET Detector Module Measuring DOI using Multiple Reflectors (여러 반사체를 사용한 양전자방출단층촬영기기의 반응 깊이 측정 검출기 모듈 개발)

  • Kim, Neung Gyun;Kim, Gu;Kwak, Jong Hyeok;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.825-830
    • /
    • 2019
  • A detector module measuring a depth of interaction was developed using silicon photomultiplier (SiPM) and two layers of scintillation crystal array treated with multiple reflectors. When reconstructing an image based on a signal obtained by using different types of reflector of each layer, the interaction positions of scintillation pixels and gamma rays could be tracked by utilizing the feature that all scintillation pixels were recorded at different positions. The bottom layer uses a specular reflector, and the top layer uses a diffuse reflector to differently process the size of the signal obtained from the SiPM. The optical grease was used to recude the sharp refractive index change between the layers of scintillator and the SiPM. The signals obtained from the 16 SiPMs were reduced to four signals using the Anger equations, and the images were reconstructed using them. All the scintillation pixels composed of the two layers appeared in the reconstructed image, which distinguished the layer where the scintillation pixels and gamma rays interacted. If the detectors, which measure the interaction depth of two layers using different reflectors, will be applied to preclinical positron emission tomography, the degradation of spatial resolution appearing outside the field of interest could be solved.

Chemical Composition of Respirable PM2.5 and Inhalable PM10 in Iksan City during Fall, 2004 (익산지역 가을철 대기 중 호흡성 및 흡입성 먼지입자의 화학조성)

  • Kang, Gong-Unn
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.1
    • /
    • pp.61-71
    • /
    • 2010
  • Intensive measurements of airborne respirable $PM_{2.5}$ and inhalable $PM_{2.5}$ were conducted in the downtown area of Iksan city. The $PM_{2.5}$ and $PM_{2.5}$ samples were collected twice a day in the Iksan city of Korea from October 17 to November 1, 2004. The purpose of the study was to determine the inorganic water-soluble components and trace elements of $PM_{2.5}$ and $PM_{2.5}$ in the atmospheric environment and estimate the contribution rate of major chemical components from a mass balance of all measured particulate species. The chemical analysis for PM samples was conducted for water-soluble inorganic ions using ion chromatography and trace elements using PIXE analysis. The mean concentrations of respirable $PM_{2.5}$ and inhalable $PM_{2.5}$ were $51.4{\pm}29.7$ and $79.5{\pm}39.6\;{\mu}g/m^3$, respectively, and the ratio was 0.62. The ion species of $NO_3$, $SO_4^2$, and $NH_4^+$ were abundant in both $PM_{2.5}$ and $PM_{2.5}$. These components predominated in respirable $PM_{2.5}$ fraction, while $Na^+$, $Mg^{2+}$, $Ca^{2+}$ mostly existed in coarse particle mode. Elemental components of S, Cl, K, and Si were abundant in both $PM_{2.5}$ and $PM_{2.5}$. These elements, except for Si, were considered to be emitted from anthropogenic sources, while Si, Al, Fe, Ca existed mainly in coarse particle mode and were considered to be emitted from crustal materials. The averaged mass balance analysis showed that ammonium nitrate, ammonium sulfate, crustal component, and other trace elements were composed of 18.4%, 13.2%, 4.8%, 3.5% for PM2.5 and 17.0%, 11.6%, 13.7%, 4.4% for $PM_{2.5}$, respectively.

Effect of Si-Wu-Tang and Si-Jun-Zi-Tang on the Survival of Jejunal Crypt Cells and Hematopoietic Cells in Irradiated Mice (방사선조사 마우스에서 소장움세포 및 조혈세포 생존에 미치는 사물탕 및 사군자탕의 영향)

  • Kim, Sung-Ho;Oh, Heon;Lee, Song-Eun;Jo, Sung-Kee;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.888-894
    • /
    • 1998
  • In order to investigate the radioprotective effect of Si-Wu-Tang (Korean name: Sa-Mul-Tang), a kind of traditional Oriental medicine as a blood-building decoction (Oriental medical concept: Bu-Xie), and Si-Jun-Zi-Tang (Korean name: Sa-Gun-Ja-Tang), one of the widely used Oriental herbal medicines as an energy tonic (Chinese medical concept: Bu-Qi). the jejunal crypt survival, endogenous spleen colony formation, and apoptosis in jejunal crypt cells were observed in irradiated mice. Jejunal crypts were protected by Si-Wu-Tang pretreated both per os (2 mg/mL of drinking water for 7 days, p<0.05) and intraperitoneally (1 mg/head, single injection at 24 hours before irradiation). Si-Wu-Tang adminstration before irradiation(1 mg/head, single injection at 24 hours before irradiation) resulted in an increase of the formation of endogenous spleen colony (p<0.005). The frequency of radiation-induced apoptosis in intestinal crypt cells was also reduced by pretreatment of Si-Wu-Tang (p<0.01). However, the radioprotective effect of Si-Jun-Zi-Tang was not as significant as that of Si-Wu-Tang. These results suggest that Si-Wu-Tang may be a useful radioprotective food, especially since it is a relatively nontoxic natural product.

  • PDF

Preparation and Crystallization Kinetics of Glasses with Ferroelectric Fresnoite Crystal (강유전체 Fresnoite 결정을 갖는 유리의 제조 및 결정화 거동)

  • Lee, Hoi-Kwan;Chae, Su-Jin;Kang, Won-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.2 s.35
    • /
    • pp.161-166
    • /
    • 2005
  • Glass formation, thermal property and crystallization behavior were investigated in $xK_2O-(33.3-x)BaO-16.7TiO_2-50SiO_2(mole\%)$ with fresnoite($Ba_2TiSi_2O_8$) crystal by replacement BaO for $K_2O$. As x(0$\le$x$\le$20) contents increased, glass formation became easy, and crystallization temperature moved on to the low temperature. Crystal phase of the $Ba_2TiSi_2O_8$ was confirmed by XRD, and the replaced x was not effected on the formation of new crystals. The kinetics of crystallization of fresnoite were studied by applying the DTA measurements carried out at different heating rates. The average avrami exponent(n) and activation energy were changed $2.26 {\pm}0.1,\;2.03 {\pm}0.1,\;1.93{\pm}0.15$, $279 {\pm}12kJ/mole,\;302{\pm}7kJ/ mole,\;319{\pm}1kJ/mole$ according to x contents, respectively. The replaced x improved the orientation of crystal growth.

  • PDF

Development of Superior Fe-Si Sintered Magnetic Cores Equivalent to Wrought Si-steels

  • Hamano, Aya;Isihara, Chio;Asaka, Kazuo
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.799-800
    • /
    • 2006
  • Wrought Si-steels are generally used for electromagnetic valves, which are needed good response. To date, Hitachi Powdered Metals Co., Ltd. have produced Fe-Si base sintered magnetic material, EU-52, which shows a magnetic flux density of more than 1.25T at 2000A/m and a maximum permeability of more than 3500. However these magnetic properties are lower than that of wrought Si-steels. Because EU-52 has a low density of $7.2Mg/m^3$. For improving the magnetic properties, it is necessary to increase the density of sintered cores. To increase density, a new mixing method of coating fine Si powders on atomized iron powders was developed, for avoiding the Kirkendall effect. As the result, developed P/M Fe-Si magnetic cores shows higher density of $7.38Mg/m^3$, higher magnetic flux density of 1.48T at 2000A/m and higher maximum permeability of 6800.

  • PDF

Efficient design of a ∅2×2 inch NaI(Tl) scintillation detector coupled with a SiPM in an aquatic environment

  • Kim, Junhyeok;Park, Kyeongjin;Hwang, Jisung;Kim, Hojik;Kim, Jinhwan;Kim, Hyunduk;Jung, Sung-Hee;Kim, Youngsug;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1091-1097
    • /
    • 2019
  • After the Fukushima accident in 2011, there has been increased public concern about radioactive contamination of water resources through fallout in neighboring countries. However, there is still no available initial response system that can promptly detect radionuclides. The purpose of this research is to develop the most efficient gamma spectrometer to monitor radionuclides in an aquatic environment. We chose a thallium-doped sodium iodide (NaI(Tl)) scintillator readout with a silicon photo multiplier (SiPM) due to its compactness and low operating voltage. Three types of a scintillation detector were tested. One was composed of a scintillator and a photomultiplier tube (PMT) as a reference; another system consisted of a scintillator and an array of SiPMs with a light guide; and the other was a scintillator directly coupled with an array of SiPMs. Among the SiPM-based detectors, the direct coupling system showed the best energy resolution at all energy peaks. It achieved 9.76% energy resolution for a 662 keV gamma ray. Through additional experiments and a simulation, we proved that the light guide degraded energy resolution with increasing statistical uncertainty. The results indicated that the SiPM-based scintillation detector with no light guide is the most efficient design for monitoring radionuclides in an aquatic environment.

Study on the Estimation of Selection Index in Broiler Breeder I. Estimation of Genetic Parameters in Broiler (육용종계의 선발지수 추정에 관한 연구 I. 육용종계 부계통과 모계통의 유전적 모교추정)

  • 김기경;손시환;오봉국
    • Korean Journal of Poultry Science
    • /
    • v.11 no.2
    • /
    • pp.86-92
    • /
    • 1984
  • Present study was carried out to estimate phenotypic and genetic parameters influencing body weight (BW) at 4 weeks of age egg breadth (EB), egg length(EL), egg shape index (SI) and egg weight (EW) at 32 weeks of age and egg numbers (EN) up to 38 weeks of age in broiler male and female lines. The data were collected from closed White Plymouth Rock (female line; G) and Cornish (male line; C) flocks involving 1193 pullets from 211 dams and 48 sires in 1982. The results obtained are summarized as follow: 1. General performance for various trails of lines C and G. The means and standard deviations of BW, EB, EL, SI, EW and EN were 668.34${\pm}$47.18, 4.23${\pm}$0,11, 5.49 ${\pm}$0.19, 77.06${\pm}$2.98, 55.73${\pm}$3.54 and 59.72${\pm}$13.39 in line C, respectively and 487.89${\pm}$ 41.43, 4.22${\pm}$0.11, 5.51${\pm}$0.19, 76.72${\pm}$3.20, 55.43${\pm}$3.26 and 76.93${\pm}$12.17 in line G, respectively. 2. Heritability Heritabilities were estimated from sire, dam and combined components. Estimates for BW, EB, EL, SI, EW and EN from combined components were 0.30, 0.29, 0,40, 0.22, 0.45 and 0.60 in line C, respectively and 0.33, 0.23, 0.28, 0.13, 0.49 and. 0.33 in line G, respectively. 3. Correlation Genetic and phenotypic correlations showed similar trend in line C and G. Genetic correlations, estimated EW with EB and EL, were high and positive (line C; 0.99, 0.75, respectively and line G; 0.94, 0.82, respectively), also correlation of EB with EL was 0.58 (both lines; 0.58). High and negative genetic correlations were shown between SI and EL in line C and G (-0.70, -0.65, respectively). Genetic correlations between SI and EW were relatively low and negative in line C and G (-0.11, -0.19, respectively) and between SI and EN were relatively low and positive in line C and G (0.25, 0.17, respectively). Between other traits, low genetic correlations were shown in both lines, High and positive correlation was estimated between hatchability and egg shape index and polynomial regression of egg shape index on hatchability was estimated; Y=-216.77+7.6216X-0.0146939X$^2$.

  • PDF

Deep Levels in Semi-Insulating GaAs : Cr and Undoped GaAs (SI GaAs : Cr과 Undoped GaAs의 깊은 준위)

  • Rhee, Jin-Koo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.11
    • /
    • pp.1294-1303
    • /
    • 1988
  • Electron and hole traps in semi-insulating GaAs with activation energies ({\Delta}E_r) ranging from 0.16 $\pm$ 0.01 to 0.98 $\pm$ 0.01 eV, have been detected and characterized by photo-induced current transient measurements. SI undoped GaAs has fewer deep levels than SI GaAs: Cr. The thermal capture cross section and density of the traps have been estimated and some of the centers have been related to native defects. In particular, the activation energy of the compensating Cr, and "0" levels in semi-insulating GaAs were accurately measured. The transient measurements were complemented by Hall measurements at T > 300K and photocurrent spectra measurements. The transition energies for the deep compensating levels obtained by the analyses of data from these measurements, when compared with those from the transient measurements, indicate negligible lattice-coupling of these centers. Analysis of the transport data also indicates that neutral impurity scattering plays a significant role in semi-insulating materials at high temperatures.

  • PDF