• 제목/요약/키워드: Shunt capacitor-reactor bank

검색결과 4건 처리시간 0.02초

분산전원을 포함한 배전계통에서 설치비용과 유지보수 비용을 고려한 병렬 캐패시터-리액터 Bank의 최적 설치 위치 선정 (Optimal Allocation of Shunt Capacitor-Reactor Bank in Distribution System with Dispersed Generators Considering Installation and Maintenance Cost)

  • 허재행;류재근;이우리;박종영;박종근
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1511-1519
    • /
    • 2013
  • This paper proposes the allocation method for capacitor-reactor banks in a distribution system with dispersed generators to reduce the installation costs, the maintenance costs and minimize the loss of electrical energy. The expected lifetime and maintenance period of devices with moving parts depends on the total number of operations, which affects the replacement and maintenance period for aging equipment under a limited budget. In this paper, the expected device lifetimes and the maintenance period are included in the formulation, and the optimal operation status of the devices is determined using a genetic algorithm. The optimal numbers and locations for capacitor-reactor banks are determined based on the optimal operation status. Simulation results in a 69-bus distribution system with the dispersed generator show that the proposed technique performs better than conventional methods.

하이브리드 타입 커패시터 뱅크를 이용한 공급신뢰도 및 전력품질 개선 방안 연구 (A Study on the Service Reliability and Power Quality Improvement Using Hybrid Type Capacitor Bank)

  • 이한상;윤동희
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.313-319
    • /
    • 2014
  • 전력계통운영의 목표는 전력시스템의 안정성과 신뢰성을 유지하여 원활한 전력을 공급하는 것이다. 안정적인 전력 공급을 위하여 무효전력과 모선 전압에 대한 고려를 해야 하는데, 모선의 전압을 일정 범위 이내로 유지하기 위하여 커패시터 뱅크를 비롯한 다양한 방안이 사용되고 있다. 본 논문에서는 계통 안정도와 전력공급 신뢰도를 상시키기 위한 하이브리드 타입의 커패시터 뱅크 설계 과정에 대하여 기술하였다. 설계 과정에는 커패시터 뱅크의 용량 산정, 리액터 타입 결정 및 리액터 용량 산정과정이 포함된다. 기존의 커패시터 뱅크의 설계과정과 같이 정상상태 Q-V 해석이나 상정사고 분석과 같은 방법을 통하여 무효전력 마진을 계산하여 저전압이 발생하는 모선에 무효전력 보상량을 산정한다. 그리고 고조파 실측을 통해 산출된 개별 고조파의 성분 크기를 기반으로 직렬 리액터의 크기를 산정하는 방식으로 설계과정을 제안하였다. 논문에서는 제안된 방법을 통하여 고조파의 크기가 감소함을 증명하였으며, 특히 5차와 7차 고조파의 저감에 효율적임을 보여주었다.

변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구 (A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation)

  • 정기석;장병훈;이현철;이근준;백영식
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.

초고압차단기용 개폐제어기 개발(II) (Development of Controlled Switching Device for High Voltage Circuit Breakers II)

  • 김동현;김연풍;이현두;이수병;김영성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1041-1043
    • /
    • 2005
  • It is expected to reduce stresses to components of high voltage circuit breaker and transferred switching surge from power system by applying controlled switching technique to high voltage system. This technique has already been applied to switch shunt reactor or capacitor bank in advanced countries. In this paper, operating software is installed in developed controlled switching device and HMI(Human-machine Interface) is under developing, In the future, this technique is expected to contribute to S.A(Substation Automation).