• 제목/요약/키워드: Shunt Capacitor Bank

검색결과 16건 처리시간 0.024초

배전계통 전압/무효전력조정을 위한 새로운 전압/무효전력제어 방식 (A New Volt/Var Control of Substation for Distribution Volt/Var Regulation)

  • 최준호;김재철;손학식;임태훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.285-288
    • /
    • 2001
  • In this paper we proposed the on line volt/var control schemes of the load Tap Changer (LTC) transformer and shunt capacitor bank for distribution volt/var regulation. In the existing volt/var control of the distribution substation, the voltage of feeders and var of distribution systems is mainly controlled by the LTC transformer tap position and on/off status of the shunt capacitor. The LTC and shunt capacitor bank has discrete operation characteristics and therefore it is very difficult to control volt/var at the distribution networks within the satisfactory levels. Also there is limitation of the operation times of the LTC and shunt capacitor bank because it is affects on their functional lifetime. The proposed volt/var control algorithm determine an optimal tap position of LTC and on/off status of shunt capacitors at a distribution network with the multiple feeders. The mathematical equations of the proposed method are introduced. Simple case study was performed to verify the effectiveness of the proposed method.

  • PDF

배전계통 전압/무효전력 보상을 위한 LTC변압기와 SC의 협조운전 알고리즘 (Cooperation Algorithms of LTC and SC for Distribution Volt/Var Regulation)

  • 최준호;김재철;남해곤;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.399-402
    • /
    • 2003
  • In this paper, the on line volt/var control algorithms of the food Load Tap Changer (LTC) transformer and Shunt Capacitor(SC) are proposed for distribution volt/var regulation. In the existing volt/var control of the distribution substation, the voltage of feeders and var of distribution systems is mainly controlled by the LTC transformer tap position and on/off status of the shunt capacitor. The LTC and shunt capacitor bank has discrete operation characteristics and therefore it is very difficult to control volt/var at the distribution networks within the satisfactory levels. Also there is limitation of the operation times of the LTC and shunt capacitor bank because it is affects on their functional lifetime. The proposed volt/var control algorithm determine an optimal tap position of LTC and on/off status of shunt capacitors at a distribution network with the multiple feeders. The mathematical equations of the proposed method are introduced. Simple case study was performed to verify the effectiveness of the proposed method.

  • PDF

23kV급 Capacitor Bank 보호 알고리즘 (A Protection Algorithm of 23kV Shunt Capacitor Banks)

  • 임정욱;권영진;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.443-445
    • /
    • 2004
  • 본 논문에서는 22.9kV급 Shunt Capacitor Bank 내부 고장으로 인한 불평형 요소를 검출하기 위하여 기존의 차동전압의 크기만을 이용한 보호 방식을 검토하고, 이 보호 방식에서 발생되는 여러 문제점들을 해결하기 위한 개선 방안을 제안한다. 기존의 차동전압의 크기를 이용한 보호 방식에서는 인입단 근처에서의 고저항 아크 고장이나 접지단 근처에서의 지락 고장 등에 의해 Capacitor 소자에 손상을 입을 수 있지만, 이에 대한 고장 판정이 용이하지 않다. 따라서 이를 해결하기 위하여 본 논문에서는 차동전압의 주파수 계전 방식 및 접지단 전압 등을 도입하였다. 특히, 주파수 계전 요소를 도입할 경우에 비선형 부하 둥으로부터 발생되는 고조파의 영향이 없다는 것을 입증하여 부하의 종류와는 무관하게 본 논문에서 제안한 방법이 적용될 수 있음을 보였다 본 논문에서 제안한 알고리즘은 사례 연구를 통하여 그 타당성이 입증되었다.

  • PDF

분산전원을 포함한 배전계통에서 설치비용과 유지보수 비용을 고려한 병렬 캐패시터-리액터 Bank의 최적 설치 위치 선정 (Optimal Allocation of Shunt Capacitor-Reactor Bank in Distribution System with Dispersed Generators Considering Installation and Maintenance Cost)

  • 허재행;류재근;이우리;박종영;박종근
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1511-1519
    • /
    • 2013
  • This paper proposes the allocation method for capacitor-reactor banks in a distribution system with dispersed generators to reduce the installation costs, the maintenance costs and minimize the loss of electrical energy. The expected lifetime and maintenance period of devices with moving parts depends on the total number of operations, which affects the replacement and maintenance period for aging equipment under a limited budget. In this paper, the expected device lifetimes and the maintenance period are included in the formulation, and the optimal operation status of the devices is determined using a genetic algorithm. The optimal numbers and locations for capacitor-reactor banks are determined based on the optimal operation status. Simulation results in a 69-bus distribution system with the dispersed generator show that the proposed technique performs better than conventional methods.

The Coordinate Control Method of LTC Transformer and Capacitor Banks at Distribution Substation

  • Choi, Joon-Ho;Ahn, Seon-Ju;Nam, Hae-Kon;Kim, Jae-Chul;Moon, Seung-Il;Jung, Won-Wook;Song, Il-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.320-329
    • /
    • 2012
  • The Load Tap Changing (LTC) transformer and Shunt Capacitor (SC) bank are major devices for voltage and reactive power control in a distribution substation. Thus, the coordination operation of a LTC transformer and a SC bank is required to achieve better voltage and reactive power compensation at a distribution substation in the same time. This paper proposes coordinate control method of LTC transformer and SC bank to achieve better voltage and reactive power compensation and operation times of these two devices in the same time. The mathematical formulations of the proposed coordinate control method are introduced. Sample case studies are shown to verify the effectiveness of the proposed coordinate control method.

비접지 분로 콘덴서 뱅크의 투입제어방식에 대한 시뮬레이션 검증 (Verification of Controlled Closing Method for Unearthed Shunt Capacitor Banks by Simulation)

  • 이우영;박경엽;정진교;김희진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.448-453
    • /
    • 2003
  • In this paper the controlled closing algorithm of the circuit breaker for isolated capacitor banks is proposed. The characteristics of circuit breakers such as RDDS(rate of decrease of dielectric strength) and a mechanical operating tolerance should be also taken into account to locate contact touch instants around voltage zero. The analysis results on the voltages across circuit breaker terminals upon closing operation play an important roles to describe the suggested method. The simulations carried out in order to verify the performance of this method show that the closing instants obtained from the proposed method provide a good suppression effect on the closing transients for both single and back-to-back capacitor banks.

하이브리드 타입 커패시터 뱅크를 이용한 공급신뢰도 및 전력품질 개선 방안 연구 (A Study on the Service Reliability and Power Quality Improvement Using Hybrid Type Capacitor Bank)

  • 이한상;윤동희
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.313-319
    • /
    • 2014
  • 전력계통운영의 목표는 전력시스템의 안정성과 신뢰성을 유지하여 원활한 전력을 공급하는 것이다. 안정적인 전력 공급을 위하여 무효전력과 모선 전압에 대한 고려를 해야 하는데, 모선의 전압을 일정 범위 이내로 유지하기 위하여 커패시터 뱅크를 비롯한 다양한 방안이 사용되고 있다. 본 논문에서는 계통 안정도와 전력공급 신뢰도를 상시키기 위한 하이브리드 타입의 커패시터 뱅크 설계 과정에 대하여 기술하였다. 설계 과정에는 커패시터 뱅크의 용량 산정, 리액터 타입 결정 및 리액터 용량 산정과정이 포함된다. 기존의 커패시터 뱅크의 설계과정과 같이 정상상태 Q-V 해석이나 상정사고 분석과 같은 방법을 통하여 무효전력 마진을 계산하여 저전압이 발생하는 모선에 무효전력 보상량을 산정한다. 그리고 고조파 실측을 통해 산출된 개별 고조파의 성분 크기를 기반으로 직렬 리액터의 크기를 산정하는 방식으로 설계과정을 제안하였다. 논문에서는 제안된 방법을 통하여 고조파의 크기가 감소함을 증명하였으며, 특히 5차와 7차 고조파의 저감에 효율적임을 보여주었다.

22.9kV급 병렬 커패시터 뱅크 내부의 아크 고장 판별을 위한 전압차동 보호 알고리즘의 개선 방안 (Improvement of the Protection Algorithm Based on Voltage Difference Method for Detecting Arcing Faults within 22.9kV Shunt Capacitor Banks)

  • 임정욱;권영진;강상희;육유경
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권2호
    • /
    • pp.61-66
    • /
    • 2005
  • This paper presents a refined protection algorithm of the unfused 22.9kV shunt capacitor banks in grounded wye connection to improve the existing algorithm using the voltage difference method. It is difficult to detect ground faults with arc near the input points or ground faults near the grounding point by the existing algorithm using only the voltage balanced relay. This paper shows that ground faults with arc near the input point can be detected by harmonics analysis of the differential voltage and that it has no impact of harmonics out of nonlinear loads which have the quantitative influence on capacitor banks. Thus the proposed method using harmonics analysis can be a proper detection method. In case of ground faults near the grounding point, an OVGR is being added recently and its validity is verified in this paper. The proposed method is applied to a 22.9kV example system and is verified that the proposed algorithm can detect clearly faults which are not easy to detect by the existing method.

154kV SC Bank의 써지 응답특성과 써지전류 저감에 관한 연구 (Study on Surge Response Characteristics and Surge Current Reduction for 154kV Shunt Capacitor Bank)

  • 허용호;최명국;이상일;정재기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.329-334
    • /
    • 2002
  • 우리나라 전력계통의 특성상 남부의 전원단과 수도권의 부하중심단과의 거리가 존재하여 안정적인 계통전압제어에 어려움이 존재한다. 이러한 계통전압제어의 어려움을 극복하기 위해 154kV 계통에 SC Bank를 설치 운용중에 있다. 운전 환경상 차단기의 투입과 차단이 잦은 154kV SC Bank에 리액터가 소손되는 등의 문제점이 발생하고 있어 154kV SC Bank의 써지응답특성을 규명하고 차단기의 투입차단시 발생하는 써지전류의 저감에 대한 연구의 필요성이 대두되고 있다. 본 연구에서는 154kV SC Bank를 대상으로하여 현장조사와 현장실증을 통해 써지전류를 측정하고, 모의를 통해 써지응답특성을 규명하였다. 그 결과, 차단기의 접점의 상태와 피뢰기의 동작여부에 의해 써지전류가 크게 영향을 받는다는 점을 확인하였다. 154kV SV Bank를 대상으로 한 현장시험과 서지응답특성의 분석결과를 기본으로 하여 피뢰기의 영향과 차단기의 투입차단 영향을 최소화하는 방안으로 피뢰기의 분리운전으로 전류재단현상을 막아 급준써지전류의 발생을 억제하고 저항투압방식의 차단기로 써지전류를 30%이하로 억제할 수 있음을 실증과 모의로 확인하였다.

  • PDF

변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구 (A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation)

  • 정기석;장병훈;이현철;이근준;백영식
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.