• Title/Summary/Keyword: Shrinkage Reduction agent

Search Result 60, Processing Time 0.027 seconds

Study on Properties of Dry Shrinkage according to Amount of Shrinkage Reduction Agent (수축저감제 혼입량에 따른 건조수축 특성 검토)

  • Seo, Tae Seok;Lee, Hyun Seung;Kim, Kang Min;Yoon, Seob
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.209-210
    • /
    • 2021
  • This study aims to develop ultra-low-shrinkage high-quality concrete. Therefore, the concrete drying shrinkage characteristics according to the type and amount of the shrinkage reducing agent were reviewed. As a result, the performance of Hexylene Glycol(HG) and Polyol was superior to that of PolyEthylene Glycol(PEG), which is most widely used in Korea. In addition, the shrinkage reduction effect was improved as the amount of PEG was increased, but the disadvantage of the strength reduction when excessive use was confirmed.

  • PDF

Prediction Model on Autogenous Shrinkage of High Performance Concrete Used Material for Shrinkage Reduction (수축저감재료의 영향을 고려한 고성능 콘크리트의 자기수축 예측 모델)

  • Koh Kyoung-Taek;Kang Su-Tae;Yoo Sung-Won;Kim Do-Gyeong;Han Cheon-Goo;Lee Jang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.285-288
    • /
    • 2004
  • Generally, the autogenous shrinkage of high performance concrete is important in that it can lead the early cracks in concrete structures. In the previous study, The. autogenous shrinakge of HPC was found to decrease with incresing expansive additive and shrinakge reduction agent. In case of combined use, the autogenous shrinakge was more reduction than in case separate use. The purpose of this study is to derive a realistic equation to estimate the autogenous shrinakge model of high performance concrete with exapnsive agent and shrinakge reduction agent. investigated the durability of high performance concrete using expansive additive and shrinkage reducing agent. The proposed equation showed reasonably good correlation with test data on autogenous shrinakge of high performance concrete with material for shrinkage reduction.

  • PDF

Drying Shrinkage Reduction of Redispersible Polymer Powder-Modified Mortars Using Powdered Shrinkage-Reducing Agent (분말수축저감제를 이용한 제유화형 분말수지 혼입 폴리머 시멘트 모르터의 건조수축 저감효과)

  • ;Ohama, Yoshihiko
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.231-236
    • /
    • 1998
  • In general, the drying shrinkage of polymer-modified mortars using redispersible polymer powders is much higher than that of unmodified mortar. The purpose of this study is to reduce the drying shringkage of polymer-modified mortars using a redispersible poly(ethylene-vinyl acetate) (EVA) powder, which is widely used for the manufacture of prepackaged-type polymer-modified mortar products at present. Polymer-modified mortars using the redispersible EVA powder with powdered shrinkage-reducing agent were prepared with various polymer-cement ratios and shrinkage-reducing agent contents, and tested for drying shrinkage and strength. From the test results, the drying shrinkage of the redispersible EVA powder-modified mortars with a powdered shrinkage agent is remarkably reduced with increasing shrinkage-reducing agent content, and becomes approximately a half of that of the redispersible EVA powder-modified mortars with the same polymer-cement ratios and without the shrinkage-reducing agent at a shrinkage-reducing agent content of 6%.

  • PDF

Study on Drying Shrinkage Properties of HPC Infilled Concrete Mixing Shrinkage Reducing Agent and Expansive Agent (수축저감제 및 팽창재를 혼입한 HPC 충전용 콘크리트의 건조수축 특성 검토)

  • Park, Ji-Woong;Ji, Woo-Ram;Shin, Ki-Don;Gao, Shan;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.9-10
    • /
    • 2017
  • In case of the concrete is poured into the HPC(Hollow Precast Concrete) column, the shrinkage condition of the HPC surface and the infilled concrete may be different, causing an interfacial space and deteriorating the integration performance. In this study, manufacturing HPC column mold and and the drying shrinkage properties with the charging concrete were examined. As a result, case of the shrinkage reducing agent showed the best drying shrinkage reduction effect. In the case of the expansive agent, the length change was lower than that of plain, but the difference from the shrinkage reducing agent was large, so it is considered that mixing condition of expansion mixing condition should be improved.

  • PDF

Shrinkage Properties of High Performance Concrete Used Expansive Additive and Shrinkage Reducing Agent (팽창재와 수축저감제를 사용한 고성능 콘크리트의 수축 특성)

  • Koh, Kyung Taek;Park, Jung Jun;Ryu, Gum Sung;Kang, Su Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.787-794
    • /
    • 2006
  • Generally, high performance concrete has characteristics such as low water-cementitious material ratio, lots of unit binder powder, thus the heat of hydration, autogenous shrinkage are tend to be increased. This study is to investigated the effect of the expansive additive and shrinkage reducing agent on the shrinkage properties of high performance concrete as a study to develop the reduction technology of the concrete shrinkage. Test results showed that the expansive additive and shrinkage reducing agent were effective the reduction of shrinkage of high performance concrete. Especially, the using method in combination with expansive additive and shrinkage reducing agent was more effective than the separately using method of that. Also, it analyzed that the combination of expansive additive of 5% and shrinkage reducing agent of 1% was the most suitable mixture, considering to the fluidity, strength and shrinkage properties.

A Study of the Shrinkage Reduction in High Performance Concrete according to the Adding Ratio of Anti-Shrinkage Agent (수축저감제 혼입률 변화에 따른 고성능 콘크리트의 수축저감에 관한 연구)

  • 한천구;김호림;문학용;강수태;고경택;김도겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.473-476
    • /
    • 2003
  • This study discusses the use of anti-shrinkage agent as the method to reduce autogenous and drying shrinkage. According to results, as for the fundamental properties of high performance concrete, fluidity and strength decrease with an increase of the adding ratio of anti-shrinkage agent, but air content increases. Compared with plain concrete, autogenous and drying shrinkage are reduced by 12~52% and 4~22% respectively upto the adding rario of anti-shrinkage agent of 2.0%. When expansive additive is added by 5.0%, they are also reduced by 38~95% and 15~50% respectively. Therefore, as expansive additive of 5.0% and anti-shrinkage agent of 1.0% are added to high performance concrete of around W/B 30%, it is considered that fluidity and strength are hardly influenced, and in addition, crack by shrinkage can be prevented effectively.

  • PDF

An Experiment Study on Drying Shrinkage Reduction of Concrete Slab (슬래브 구조물용 콘크리트의 건조수축 저감에 관한 연구)

  • Sohn Yu Shin;Lee Seung Hoon;Park Chan Kyu;Kim Gyu Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.592-595
    • /
    • 2004
  • This Study discusses the properties of drying shrinkage of concrete slab with W/B, water content, fiber and anti-shrinkage agent. According to results, drying shrinkage is reduced with decrease of water content and W/B. Also, compared with plain concrete, drying shrinkage is reduced by using of fiber, anti-shrinkage agent and adding ratio of anti - shrinkage agent. Therefore, in the range of workability if water content and W/B are reduced and using of fiber and anti-shrinkage agent are performed properly, crack by drying shrinkage can be prevented effectively.

  • PDF

Drying Shrinkage Characteristics of the Concrete Incorporated Shrinkage Reducing Agent According to Mixed Proportion of Concrete (콘크리트 배합조건에 따른 수축저감제의 건조수축 특성)

  • Kim, Young-Sun;Kim, Kwang-Ki;Park, Soon-Jeon;Kim, Jung-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.3
    • /
    • pp.245-252
    • /
    • 2017
  • Recently, structures such as large retailers, outlets and warehouses have been increasing in accordance with changes in consumption patterns. Since these structures include ultra-flat slab members, they are thoroughly managed to control slab cracking by the plastic and drying shrinkage. In order to control the cracking of the slab member, a chemical crack reduction method is used. In particular, the use of the shrinkage reducing agent has been examined. However, domestic research results are limited. In this study, the shrinkage properties of concrete using shrinkage reducing agent and the drying shrinkage properties according to the mixing factors were investigated. The performance of domestic shrinkage reducing agent was appeared similar to that of overseas high-grade shrinkage reducing agent. As the shrinkage reducing agent usage increased, the drying shrinkage reduction effect increased. At the age of 100 days, the dry shrinkage rate of specimen with the shrinkage reducing agent of 1.5%was shown about half that of the specimen without the shrinkage reducing agent. The shrinkage reducing agent was gound to have no specific performance change for the use of the admixture.

Reduction of Drying Shrinkage Cracking of Box Culvert for Power Transmission with Shrinkage Reducing Agent (수축저감제 혼입에 따른 전력구 박스구조물의 건조수축균열 저감)

  • Woo, Sang-Kyun;Kim, Ki-Jung;Lee, Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.102-108
    • /
    • 2016
  • The purpose of this study is to examine the reduction effect of shrinkage reducing agent for drying shrinkage induced cracking and suggest the method of controlling the cracking in concrete box culvert for power transmission. Based on drying shrinkage cracking mechanism, it is necessary to perform the numerical analysis, which involves shrinkage reducing effect of shrinkage reducing agent. From the numerical results, it is found that cracking behavior for longitudinal direction and transverse direction due to differential drying shrinkage of box culvert can occur and the experimental observation of concrete cracks support the numerical predictions. The shrinkage reducing agent reduced the concrete cracking by 40~50%, which shows the methodology of controlling of drying shrinkage cracks in box culverts in real construction site.

Evaluating Shrinkage Characteristic of Ternary Grout for PSC Bridge Using Expansive Additive and Shrinkage Reducing Agent (팽창재 및 수축저감제를 이용한 PSC 교량용 3성분계 그라우트의 수축특성 평가)

  • Yuan, Tian-Feng;An, Gi-Hong;Ryu, Gum-Sung;Koh, Kyoung-Taek;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.519-525
    • /
    • 2016
  • This paper reports on analyzing the free and restrained shrinkage characteristic of ternary grout used cementitious admixture. In this study, the cementitious admixture was used such as fly ash, ziricania silica fume by combination of expansive additive (a, b) and shrinkage reducing agent. And a number of basic performance tests were conducted to investigate bleeding, volume change, fluidity and compressive strength behavior. According to the results, within appropriate mixing ratio, even the fluidity is not influenced by expansive additive and shrinkage reducing agent, the resistant properties of bleeding, volume change, shrinkage and compressive strength are increased. Comparing with plain grout, the free shrinkage reduced by a minimum of 29% which specimens are added expansive additive and shrinkage reducing agent. The combination of expansive additive a and shrinkage reducing agent is the most effective for reduction of shrinkage. And increasing the mixing ratio of expansive additive and shrinkage reducing agent extended cracking time. Nevertheless, combined addition of expansive additive a 2.0% and shrinkage reducing agent 0.50% has best shrinkage reduction behavior and not appeared cracking. From the above, the mixing ratio of 2.0% of expansive additive a and 0.50% of shrinkage reducing agent is high performance ternary grout for PSC bridge.