Development and Validation of an HPLC Method for the Pharmacokinetic Study of Pentoxifylline in Human Serum (체내동태 연구를 위한 혈청 중 펜톡시필린의 HPLC 정량법 개발 및 검증)
-
- Journal of Pharmaceutical Investigation
- /
- v.36 no.2
- /
- pp.89-95
- /
- 2006
A selective and sensitive reversed-phase HPLC method for the determination of pentoxifylline in human serum was developed, validated, and applied to the pharmacokinetic study of pentoxifylline. Pentoxifylline and internal standard, chloramphenicol, were extracted from the serum by liquid-liquid extraction with dichloromethane and analyzed on a Luna CI8(2) column with the mobile phase of acetonitrile-0.034 M phosphoric acid (25:75, v/v, adjusted to pH 4.0 with 10 M NaOH). Detection wavelength of 273 nm and flow rate of 0.8 mL/min were used. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of the serum was 10 ng/mL, which was sensitive enough for pharmacokinetic studies of pentoxifylline. The overall accuracy of the quality control samples ranged from 89.3 to 92.7% for pentoxifylline with overall precision (% C.V.) being 4.1-9.2%. The relative mean recovery of pentoxifylline for human serum was 105.8%. Stability (stock solution, short and long-term) studies showed that pentoxifylline was not stable during storage. But three freeze-thaw cycles and extracted serum samples were stable. This method showed good ruggedness (within 15% C.V.) and was successfully applied for the analysis of pentoxifylline in human serum samples for the pharmacokinetic studies of orally administered
This study concerns the transmission of energy and data using induced electromotive force. Due to the requirements of weapon systems, most arms are kept in an armory for a very long time before being used. During this time, the reserve battery, which serves mostly as a power supply for the electronic fuze, can be degraded, thus causing problems when it is actually needed. We attempt to solve the various problems associated with the old fuze system caused by long-term storage by using the 'induction power' transmitted from another device just before its operation, instead of using 'built-in power'. We tried to find the best carrier frequency to communicate with the system by induced electromotive force. Also, we changed the communication method for transmitting the 'induction power' from 'FM/AM modulation' to 'Duty ratio modulation', which can transmit a large amount of data in a short time. Through experiments, it was demonstrated that the induction coil can replace the reserve fuze's battery without any problem, thus confirming the possibility of using an induction coil as the power supply source of the electronic fuze.
It is common that in the vegetable cultivation areas, the farmers tend to continue the heavy fertilization to maximize the crop yields in short term. This results in the accumulation of fertilizer elements in the soil and increase in the electrical conductivity of soil. Disregarding these, farmers continue to apply heavy doses of fertilizers. A field experiment was conducted to find out on such a soil whether fertilizer application taking the quantity of nutrients accumulated in the soil into account would save the fertilizer without losing the yield of crop, using Chinese cabbage and spinach as test crops. The findings of the experiment is summarized as following. 1. The yield of Chinese cabbage was not affected by reduction of
In the present study we verified performance of feed-forward control algorithm using short term prediction of ship motion information by taking advantage of developed numerical simulation model of FPSO motion. Up until now, various studies have been conducted about thrust control and allocation for dynamic positioning systems maintaining positions of ships or marine structures in diverse sea environmental conditions. In the existing studies, however, the dynamic positioning systems consist of only feedback control gains using a motion of vessel derived from environmental loads such as current, wind and wave. This study addresses dynamic positioning systems which have feedforward control gain derived from forecasted value of a motion of vessel occurred by current, wind and wave force. In this study, the future motion of vessel is forecasted via Brown's Exponential Smoothing after calculating the vessel motion via a selected mathematical model, and the control force for maintaining the position and heading angle of a vessel is decided by the feedback controller and the feedforward controller using PID theory and forecasted vessel motion respectively. For the allocation of thrusts, the Lagrange Multiplier Method is exploited. By constructing a simulation code for a dynamic positioning system of FPSO, the performance of feedforward control system which has feedback controller and feedforward controller was assessed. According to the result of this study, in case of using feedforward control system, it shows smaller maximum thrust power than using conventional feedback control system.
In contrast to the short-term nature of lunar missions in the past, lunar missions in new space era aim to extend the presence on the lunar surface and to use this capability for the Mars exploration. In order to realize extended human presence on the Moon, production and use of consumables and fuels required for the habitation and transportation using in-situ resources is an important prerequisite. The Global Exploration Roadmap presented by the International Space Exploration Coordination Group (ISECG), which reflects the space exploration plans of participating countries, shows the phases of progress from lunar surface exploration to Mars exploration and relates in-situ resource utilization (ISRU) capabilities to each phase. Based on the ISRU Gap Assessment Report from the ISECG, ISRU technology is categorized into in-situ propellant and consumable production, in-situ construction, in-space manufacturing, and related areas such as storage and utilization of products, power systems required for resource utilization. Among the lunar resources, leading countries have prioritized the utilization of ice water existing in the permanent shadow region near the lunar poles and the extraction of oxygen from the regolith, and are preparing to investigate the distribution of resources and ice water near the lunar south pole through unmanned landing missions. Resource utilization technologies such as producing hydrogen and oxygen from water by hydroelectrolysis and extracting oxygen from the lunar regolith are being developed and tested in relevant lunar surface analogue environments. It is also observed that each government emphasizes the use and development of the private sector capabilities for sustainable lunar surface exploration by purchasing lunar landing services and providing opportunities to participate in resource exploration and material extraction.
Pexa-Vec (JX-594) is a specific cancer-targeted oncolytic and immunotherapeutic vaccinia virus. The purpose of this study was to develop methods to maximize the stability of Pexa-Vec. In short-term instability testing, viral activity was rapidly decreased both at 4℃ and at room temperature (RT), but it was completely restored after sonication followed by vortex. Long-term stability testing of Pexa-Vec in the following liquid formulations was performed: (A) 30 mM Tris/pH 7.6, (B) 30 mM Tris/pH 8.6, (C) 30 mM Tris/pH 7.6, 150 mM NaCl, 15% sucrose, (D) 30 mM Tris/pH 7.6, 15% sucrose, and (E) 30 mM Tris/pH 8.6, 15% sucrose. Viral activity decreased less than 2 log10 at 4℃, and RT was observed in 3 days in B, while viral activity was not decreased even after 4–8 weeks at 4℃ and at 1 week in RT in A, suggesting that neutral pH may be essential to maintain virus stability. The addition of 15% sucrose into A (D) significantly increased viral stability at −20℃, 4℃, or RT, and it was also observed at pH 8.6 (E). The addition of 150 mM NaCl into D (C) significantly increased viral stability in addition to the sucrose effect at 4℃ or RT. Accordingly, the viral activity in formulation C was maintained for 1.5 years at 4℃, and for 1-2 weeks in RT. In conclusion, we propose that formulation C can provide the most adequate condition for the proper storage of vaccinia oncolytic virus.
It has been reported that trans fat (tFA) may have adverse or beneficial effect depending upon the position and number of double bonds. The presence of tFA in human tissues and fluids is related to dietary intake, intestinal absorption, metabolism and storage, exchanges among compartments. This study investigated the effect of breads containing tFA, soybean or rice on postprandial plasma fatty acid and lipid composition. 33 healthy volunteers were divided into 3 groups and fed soybean bread, rice bread or wheat bread groups containing equivalent amounts of tFA (elaidic acid rich, 3.75 g/day), respectively. Postprandial lipid profiles at 0, 1, 2, 3 and 4 hours after a respective meal were studied. Plasma fatty acid was extracted by the method of Folch and methyl ester of fatty and prepared by acid transmethylation and analyzed by Gas Chromatography. Peaks were identified using pure reference compounds and quantified. Postprandial data indicated that consumption of soybean and rice breads with 3.75 g tFA retarded the appearance of C18:1 and C18:2 tFA in plasma lipid compared to that of wheat bread. Futhermore, soybean and rice bread groups showed lower plasma saturated fatty acid levels than wheat bread group. Postprandial TG level was significantly lowered in soybean bread group compared to that of rice and wheat bread groups. These results imply that soybean bread with high dietary fiber content and biologically active substances may inhibit or delay lipid absorption.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70