• Title/Summary/Keyword: Short-circuit line

Search Result 201, Processing Time 0.028 seconds

A Train Position Detection Method by Inductive Radio Line (유도무선에 의한 열차 위치검지 방식)

  • Joung, E.J.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.788-790
    • /
    • 1993
  • In the train position defection for the rail car, which is not able to obtain the short circuit between the track circuit and the wheel, the methods by the inductive radio of non-contact type are applicated. It is represented the principles and the methods of the inductive radio train detection on MLU, Transrapid, HSST, M-Bahn, and People Mover for MAGLEV, on Kobe system for the rubber-tired vehicle, and on ICE for wheel-on-rail.

  • PDF

Study on RF characteristics of voltage-controlled artificial transmission line employing periodically arrayed diodes for application to highly miniaturized wireless communication systems (초소형 무선 통신 시스템에서의 응용을 위한 주기적으로 배열된 다이오드를 이용한 전압제어형 전송선로의 RF 특성에 관한 연구)

  • Kim, Soo-Jeong;Kim, Jeong-Hoon;Jeong, Jang-Hyeon;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • In this paper, we studied the RF characteristics of a voltage-controlled artificial transmission line employing periodically arrayed diodes for application to highly miniaturized wireless communication systems on an MMIC (monolithic microwave integrated circuit). According to the results, the novel voltage-controlled artificial transmission line employing periodically arrayed diodes exhibited a short wave length, which was only 35.2% that of the conventional transmission line, owing to increasing capacitance. In addition, it's effective permittivity and effective propagation constant exhibited considerably higher values than those of the conventional transmission line. Furthermore, attenuation constant of the voltage-controlled artificial transmission line was far higher than that of the conventional transmission line. Using the closed-form equation, we theoretically analyzed the equivalent circuit of the voltage-controlled artificial transmission line.

Transmission Line Based Plucked String Model (전송선로 기반 탄현 모델)

  • Lee, Jingeol;French, Mark
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.361-368
    • /
    • 2013
  • As one way to describe the behavior of a vibrating string, analogies to a transmission line have been made based on the fact that they have oppositely travelling waves on each of them. In such analogies, a rigid end to the string has been represented as an open circuit, and the displacement of the string as the current on the transmission line. However it turns out that the rigid end corresponds to a short circuit, the displacement to the voltage by the theory of the transmission line, and it is confirmed by experiments with circuit simulations. Based on these discoveries, a transmission line based plucked string model comprising a transmission line, two piecewise linear current sources, and switches is proposed. The proposed model is validated by showing that the voltage at the arbitrarily chosen location, and the voltage calculated over an infinitesimal portion at the end of the transmission line are consistent with the displacement at the corresponding location and the force on the rigid end of the string from the well known difference form of a wave equation governing the behavior of the string with its fundamental frequency tuned to that for the proposed model, respectively. Moreover, the applicability of the proposed model to modeling string and wind instruments is presented.

Test of Independence Between Variables to Estimate the Frequency of Damage in Heat Pipe (열수송관 파손빈도 추정을 위한 변수간 독립성 검정)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.61-67
    • /
    • 2023
  • Heat pipes located underground in urban areas and operated under high temperature and pressure conditions can cause large-scale human and economic damage if damaged. In order to predict damage in advance, damage and construction information of heat pipe are analyzed to derive independent variables that have a correlation with frequency of damage, and a simple regression analysis modified model using each variable is applied to the field. However, as the correlation between independent variables applied to the model increases, the independence between variables is harmed and the reliability of the model decreases. In this study, the independence of the pipe diameter, burial depth, insulation level of monitoring system, and disconnection or short circuit of the detection line, which are judged to be interrelated, was tested to derive a method for combining variables and setting categories necessary to apply to the frequency of damage estimation model. For the test of independence, the continuous variables pipe diameter and burial depth were each converted into three categories, insulation level of monitoring system was converted into two categories, and the categorical variable disconnection or short circuit of the detection line status was kept as two categories. As a result of the test of independence, p-value between pipe diameter and burial depth, level of monitoring system and disconnection or short circuit of the detection line was lower than the significance level (α = 0.05), indicating a large correlation between them. Therefore, the pipe diameter and burial depth were combined into one variable, and the categories of the combined variable were set to 9 considering the previously set categories. The insulation level of monitoring system and the disconnection or short circuit of the detection line were also combined into one variable. Since the insulation level is unreliable when the detection line status is disconnection or short circuit, the categories of the combined variable were set to 3.

Fault Diagnosis for Induction Motor Drive System (유도 전동기 구동 시스템의 고장진단)

  • Kim, Ho-Geun;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.154-156
    • /
    • 1993
  • In this paper, fault analysis using simulation method and fault diagnosis scheme are presented for induction motor drive system. Major faults such as inverter 'a' phase open fault, inverter 'a'-'b' phase short circuit fault and inverter 'a' phase ground fault are analyzed and simulated. On-line and off-line fault diagnosis systems are proposed.

  • PDF

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

Non-Resonant Waveguide Technique for Measurement of Microwave Complex Permittivity of Ferroelectrics and Related Materials

  • Jeong, Moongi;Kim, Beomjin;Poplavko, Yuriy;Kazmirenko Victor;Prokopenko Yuriy;Baik, Sunggi
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.7 s.278
    • /
    • pp.449-454
    • /
    • 2005
  • A waveguide method is developed to study the materials with relatively large dielectric constants at microwave range. Basically, the method is similar to the previous waveguide methods represented by short-circuit line and transmission/reflection measurement methods. However, the complex permittivity is not determined by the shift in resonance frequencies, but by numerical analysis of measured scattering parameters. In order to enhance microwave penetration into the specimen with relatively large permittivity, a dielectric plate with lower permittivity is employed for impedance matching. The influences of air gap between the specimen and waveguide wall are evaluated, and the corresponding errors are estimated. The propagation of higher order modes is also considered. Experimental results for several reference ceramics are presented.

Analysis on Reduction Method of Symmetrical Fault Current in a Power System with a SFCL applied into Neutral Line (전력계통의 중성선에 적용된 초전도한류기의 대칭고장전류 저감방안 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.2
    • /
    • pp.148-152
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) applied into the neural line of a power system, which can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault, was reported to be the effective application location of the SFCL in a power system. However, the limiting operation for the symmetrical fault current like the triple line-ground fault is not effective because of properties of the balanced three-phase system. In this paper, the limiting method of the symmetrical fault current in a power system with a SFCL applied into neutral line was suggested. Through the short-circuit experiments of the three-phase fault types for the suggested method, the fault current limiting and recovery characteristics of the SFCL in the neutral line were analyzed and the effectiveness of the suggested method was described.

Thermal Runaway Prevention of MOV and Safety Improvement of Power Line System and Internal Electronic Device Circuit Using a Phosphorous Switching Module (인청동 스위칭 모듈을 이용한 전력계통 및 전자기기 내부회로의 MOV 열폭주 방지와 안전성 개선)

  • Kim, Ju-Chul;Choi, Gyung-Ray;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.75-79
    • /
    • 2011
  • The MOV(Metal Oxide Varistor), a voltage limiting element, has been installed in the SPD(Surge Protective Device) or inside the internal circuit of an electronic appliance for protection of the electric power system and electronic device against electrical surge. Such an MOV is exposed, however, to the risk of the thermal runaway resulting from excessive voltage and deterioration. In this paper, a reciprocal action has been tested and analyzed using a phosphorus bronze switching module and the low-temperature solder. And a short current break characteristic test linked with the circuit breaker has been performed to limit the inrush current when the MOV breaks down. It has been proven that the phosphorus bronze switching module installed inside the internal circuit can improve the safety of the power line system and the electronic device.