• Title/Summary/Keyword: Short-baseline

Search Result 272, Processing Time 0.026 seconds

Glycemic control of type 2 diabetic patients after short-term zinc supplementation

  • Oh, Hyun-Mee;Yoon, Jin-Sook
    • Nutrition Research and Practice
    • /
    • v.2 no.4
    • /
    • pp.283-288
    • /
    • 2008
  • This study was carried out to determine whether a short-tenn zinc supplementation contributes to beneficial changes in glycemic control among type 2 diabetic patients. Seventy-six diabetic subjects and 72 normal adults participated in this study. Subjects were divided into supplemented and control groups. Forty-four diabetic patients and 34 normal subjects were supplemented with 50 mg zinc daily as zinc gluconate for 4 weeks. Zinc status was assessed from fasting plasma levels and urinary excretion. The effects of zinc supplementation on fasting blood glucose, $HbA_{1c}$, insulin, and C-peptide were measured at the beginning of the study and after 4 weeks of supplementation. The changes in glycemic control indicators were compared between diabetic groups, classified by baseline $HbA_{1c}$ levels, and by diabetic duration. At baseline, the incidence of marginal zinc deficiency in the diabetic group, as determined by plasma zinc level, was approximately twice as high as in the normal adult group. The changes of $HbA_{1c}$ concentration, and fasting blood glucose following supplementation were not statistically significant in diabetic subjects. In normal subjects, a significant decrease of $HbA_{1c}$ occurred only in the zinc supplemented group. No significant changes were observed for serum insulin and C-peptide in diabetic as well as normal subjects. However, when the changes were compared by baseline $HbA_{1c}$ level, we found that diabetic subjects with $HbA_{1c}\;{\geq}\;7.5%$ showed significantly improved levels of $HbA_{1c}$ and fasting glucose after Zn supplementation. While such improvement in fasting blood glucose was significant among diabetics with shorter diabetic duration, significant levels of increase in serum insulin and C-peptide were observed in zinc supplemented subjects with longer diabetic duration. Fasting blood glucose was significantly decreased, whereas serum insulin and C-peptide were increased in diabetics with marginal zinc status. Therefore, we suggest that Zn supplementation for a short-term period may improve glycemic control in diabetic patients with higher $HbA_{1c}$ levels and marginal zinc status.

Short- and Long-term Effects of a Physical Exercise Intervention on Work Ability and Work Strain in Symptomatic Menopausal Women

  • Rutanen, Reetta;Luoto, Riitta;Raitanen, Jani;Mansikkamaki, Kirsi;Tomas, Eija;Nygard, Clas-Hakan
    • Safety and Health at Work
    • /
    • v.5 no.4
    • /
    • pp.186-190
    • /
    • 2014
  • Background: Physical exercise during leisure time is known to increase physical capacity; however, the long-term effects on work ability and work strain are inconclusive. The aim of this study was to investigate the effects of a 6-month physical exercise program on work ability and work strain after 6 months and 30 months, among women with menopausal symptoms at baseline. Methods: A questionnaire including questions on work ability and work strain was mailed in the beginning, at 6 months and after 30 months after the intervention to occupationally active women participating in a randomized controlled study on physical exercise and quality of life. The intervention included aerobic exercise training 4 times per week, 50 minutes per session. Work ability was measured with the Work Ability Index (WAI) and with questions about physical and mental work strain. Results: Women aged 47-62 years (N=89) who were occupationally active at baseline were included in the analyses. The increase in WAI from baseline to the end of the exercise intervention (6 months) was statistically significantly greater among the intervention group than among the control group (regression coefficient 2.08; 95% confidence interval 0.71-3.46). The difference between the groups persisted for 30 months. No significant short- or long-term effects on physical and mental work strain were found. Conclusion: A 6-month physical exercise intervention among symptomatic menopausal women had positive short-term as well as long-term effects on work ability.

Long-baseline single-layer 2nd-order $high-T_c$ SQUID gradiometer (긴기저선을 가진 단일층 고온초전도 SQUID 2차미분기)

  • Lee Soon-Gul;Kang Chan Seok;Kim In-Seon;Kim Sang-Jae
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.6-10
    • /
    • 2005
  • We have studied feasibility of single-layer second-order $high-T_c$ SQUID gradiometers in magnetocardiography. We have measured human cardiomagnetic signals using a short-baseline (5.8 mm) single-layer second-order YBCO gradiometer in partially shielded environments. The gradiometer has an overall size of $17.6\;mm{\times}6\;mm$ and contains three parallel-connected pickup coils which are directly coupled to a step-edge junction SQUID. The gradiometer showed an unshielded gradient noise of $0.84\;pT/cm^2/Hz^{1/2}$ at 1 Hz, which corresponds to an equivalent field noise of $280\;fT/Hz^{1/2}$. The balancing factor was $10^3$. Based on the same design rules as the short-baseline devices, we have studied fabrication of 30 mm-long baseline gradiometers. The devices had an overall size of $70.2\;mm{\times}10.6\;mm$ with each pickup coil of $10\;mm{\times}10\;mm$ in outer size. As Josephson elements we made two types of submicron bridges, which are variable thickness bridge (VTB) and constant thickness bridge (CTB), from $3\;{\mu}m-wide$ and 300 nm-thick YBCO lines with a thin layer of Au on top by using a focused ion beam (FIB) patterning method. VTB was 300 nm wide, 200 nm thick, 30 nm long with Au removed and CTB 100 nm wide and 30 nm long. In temperature-dependent critical currents, $I_c(T)$, VTB showed an nonmetallic barrier-type behavior and CTB an SNS behavior. We believe that those characteristics are ascribed to naturally formed grain boundaries crossing the bridges.

  • PDF

The Improved Success Rate of Integer Ambiguity Resolution by Using Many Visible GPS/GNSS Satellites

  • Kondo, Kentaro
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.243-246
    • /
    • 2006
  • This study investigates the improvement in the theoretical success rate of the integer ambiguity resolution in GPS/GNSS carrier-phase positioning by using many visible satellites. It estimates the dependence of the rate on the baseline length in relative positioning under the condition of the use of double/triple-frequency navigation signals. The calculation results show that the use of 14 navigation satellites (i.e., seven GPS and seven Galileo ones) remarkably improves the success rate under the condition of very short baseline length, compared with the use of seven GPS ones. The numerical reliability of the calculated success rates is strictly tested by examining the tightness of the union and minimum-distance bounds to the rate. These bounds are also shown to be effective to investigate the realization of the high success rates.

  • PDF

Covariance-based source localization performance improvement for underwater ultra-short baseline systems (공분산 기반 수중 ultra-short baseline 시스템의 위치 추정 성능 개선 기법)

  • Sangman Han;Minhyuk Cha;Haklim Ko;Hojun Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.89-94
    • /
    • 2024
  • Since Ultra-Short BaseLine (USBL) uses an array with narrow sensor spacing, precise synchronization is required to improve source localization performances. However, in the underwater environment, synchronization errors occur due to relatively strong noise and underwater acoustic channels such as multipath and Doppler, which deteriorates the source localization performances. This paper proposes a covariance-based synchronization compensation method to improve the source localization performances of the underwater USBL systems. The proposed method arranges the received signals through cross-correlation and calculates the covariance of the arranged signals. The synchronization error is related to the phase difference in the covariance. Thus, the phase difference is estimated as the covariance and compensated. Computer simulations demonstrate that the proposed method has better source localization performances than the conventional cross-correlation method.

AN EFFECTIVE SEGMENT PRE-FETCHING FOR SHORT-FORM VIDEO STREAMING

  • Nguyen Viet Hung;Truong Thu Huong
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.3
    • /
    • pp.81-93
    • /
    • 2023
  • The popularity of short-form video platforms like TikTok has increased recently. Short-form videos are significantly shorter than traditional videos, and viewers regularly switch between different types of content to watch. Therefore, a successful prefetching strategy is essential for this novel type of video. This study provides a resource-effective prefetching technique for streaming short-form videos. The suggested solution dynamically adjusts the quantity of prefetched video data based on user viewing habits and network traffic conditions. The results of the experiments demonstrate that, in comparison to baseline approaches, our method may reduce data waste by 21% to 83%, start-up latency by 50% to 99%, and the total time of Re-buffering by 90% to 99%.

The Effects of Short Term Schroth Exercise on the Cobb Angle, Angle of Trunk Rotation, Cosmetic Appearance, and Quality of Life in Idiopathic Scoliosis (단기간 슈로스(Schroth) 운동이 특발성 척추측만증 환자의 척추측만각도(Cobb Angle), 몸통회전도, 외형 그리고 삶의 질에 미치는 영향)

  • Kim, Ji-Seon;Lee, Sook;Lim, Dong-Hwan;Cho, Eun-Woo;Seo, Dong-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.1
    • /
    • pp.93-101
    • /
    • 2017
  • PURPOSE: The purpose of this study was to describe the effects of short term Schroth exercise on the Cobb angle, angle of trunk rotation (ATR), cosmetic appearance, and quality of life (QOL) in idiopathic scoliosis patients. METHODS: Five subjects with idiopathic scoliosis, (female, 3; male, 2) curvature type: thoracic, 2; lumbar, 3 underwent short term Schroth exercise for seven days. The exercise was performed for 3 h long sessions per day. The Cobb angle and QOL were measured before and after the intervention. ATR and cosmetic appearance were measured once. Sessions consisted of one baseline, seven intervention and three follow-up phases. The sessions were conducted with a one day interval. RESULTS: After the intervention, the Cobb angle was found to be significantly improve (p <.05), while the QOL did not differ (p>.05). The ATR showed decreased trends in the intervention phase. Data points during the intervention and follow-up phases showed a decrease in comparison with data points at the baseline, indicating that Schroth exercise might be effective in reducing the ATR and that these effects can be maintained after the intervention. Cosmetic appearance did not showed changed trends during the Schroth exercise intervention phase. CONCLUSION: Our results suggest that short term Schroth exercise may be valuable in improving the Cobb angle and ATR in patients with idiopathic scoliosis.

Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading

  • Alan, Raif;Marakoglu, Ismail;Haliloglu, Seyfullah
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.5
    • /
    • pp.169-177
    • /
    • 2015
  • Purpose: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and mini dental implants with regard to associated clinical parameters and peri-implant crevicular fluid (PICF) levels of cathepsin-K (CTSK), RANK ligand (RANKL), and osteoprotegerin (OPG), after prosthodontic loading. Methods: A total of 78 non-submerged implants (Euroteknika, $Aesthetica^{+2}$, Sallanches, France) were installed in 30 subjects (13 male, 17 female; range, 26-62 years) who visited the clinic of the Periodontology Department, Faculty of Dentistry, Selcuk University. Sampling and measurements were performed on the loading date (baseline) and 2, 14, and 90 days after loading. Assessment of the peri-implant status for the implant sites was performed using the pocket probing depth (PPD), modified plaque index, modified gingival index, modified sulcular bleeding index, and radiographic signs of bone loss. PICF samples collected from each implant were evaluated for CTSK, RANKL, and OPG levels using the ELISA method. Keratinized tissue and marginal bone loss (MBL) were also noted. Results: Clinical parameters statistically significantly increased in each group but did not show statistical differences between groups without PPD. Although implant groups showed a higher MBL in the upper jaw, only the standard dental group demonstrated a statistically significant difference. At 90 days, the OPG:sRANKL ratio and total amounts of CTSK for each group did not differ from baseline. Conclusions: Within the limitations of this study, both short and mini dental implants were achieving the same outcomes as the standard dental implants in the early period after loading.

Development of GPS-RTK Algorithm for Improving Geodetic Performance in Short Baseline (단기선 측지 성능 향상을 위한 GPS-RTK 알고리즘 개발)

  • Choi, Byung-Kyu;Lee, Sang-Jeong;Park, Jong-Uk;Baek, Jeong-Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.4
    • /
    • pp.461-467
    • /
    • 2009
  • Relative positioning technique by GPS that can obtain the high positioning accuracy has been used for generation of high precision positioning with elimination or the reduction of the common errors. This paper gives some algorithms for RTK and considers the filter to estimate the positioning information and integer ambiguities at each epoch in the whole algorithms. The extended kalman filter has been employed to estimate the state parameters and the modified LAMBDA to resolve the integer ambiguities. The data processing was performed by GPS single frequency and dual frequency in short baseline. The verification procedure of these positioning compared with results from Bernese 5.0 software. We presented some statistic values on positioning errors and the rates of integer ambiguity resolution.

A hybrid navigation system of underwater vehicles using fuzzy inferrence algorithm (퍼지추론을 이용한 무인잠수정의 하이브리드 항법 시스템)

  • 이판묵;이종무;정성욱
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.170-179
    • /
    • 1997
  • This paper presents a hybrid navigation system for AUV to locate its position precisely in rough sea. The tracking system is composed of various sensors such as an inclinometer, a tri-axis magnetometer, a flow meter, and a super short baseline(SSBL) acoustic position tracking system. Due to the inaccuracy of the attitude sensors, the heading sensor and the flowmeter, the predicted position slowly drifts and the estimation error of position becomes larger. On the other hand, the measured position is liable to change abruptly due to the corrupted data of the SSBL system in the case of low signal to noise ratio or large ship motions. By introducing a sensor fusion technique with the position data of the SSBL system and those of the attitude heading flowmeter reference system (AHFRS), the hybrid navigation system updates the three-dimensional position robustly. A Kalman filter algorithm is derived on the basis of the error models for the flowmeter dynamics with the use of the external measurement from the SSBL. A failure detection algorithm decides the confidence degree of external measurement signals by using a fuzzy inference. Simulation is included to demonstrate the validity of the hybrid navigation system.

  • PDF