• 제목/요약/키워드: Short-Circuit Current

검색결과 1,004건 처리시간 0.032초

500MVA급 단락발전기 여자시스템의 특성개선 (A study of excitation system of 500MVA short-circuit generator)

  • 정흥수;김선구;노창일;김원만;이동준;김선호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.989-990
    • /
    • 2007
  • The excitation system of 500 MVA short-circuit generator is very important because of operation of various condition, for example, (over) load switching, short-time withstand current, short-circuit making and breaking current, etc. This paper introduces a feature of excitation system of 500MVA short-circuit generator and the function and construction.

  • PDF

$CO_2$ 용접의 천이이행 조건에서 스패터 발생과 파형인자와의 관계 (Relationship between Spatter Generation and Waveform Factors in Transitional Condition of $CO_2$ Welding)

  • 강봉용;이창한;김희진;장희석
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 1998
  • $CO_2$ gas shielded arc welding has been characterized with its harsh arc compared to Ar-based shielding gases and with its high level of spattere specially in welding current range of 250~300 amperes. In this range of welding current, the metal transfer mode showed to be changed from short circuit to globular with the increase of welding voltage resulting in so-called the transitional mode in which both modes of transfer appeared together. To characterize the transitional mode, the short circuit events were divided into two groups, i.e. normal short circuit (N.S.C) which has short circuit time $(t_s)$ over 2msec and instantaneous short circuit (I.S.C) of $t_s$$\leq$2msec. The experimental results showed that the number of N.S.C decreased almost linearly with the increase of welding voltage and appeared to be not related with spatter generation rate. However I.S.C became to be pronounced in the transitional condition and its number reached the maximum value at around 29.0 volts. Considering the relation with the spatter generation rate, it was found that the number of I.S.C had a very strong correlation with the spatter generation rate of the transitional condition. It was further demonstrated that spatter generation rate decreased quite linearly with the decrease of I.S.C frequency. It implies that I.S.C is the most important waveform factor controlling the spatter generation of the transitional mode, i.e. in the middle range of welding current. Based on these results, It was discussed that in the transitional mode the basic concept of waveform control for suppressing spatter generation would be different from the one applied for typical short circuit transfer mode of low welding current.

  • PDF

GMAW 공정에서 아크 안정성의 실시간 측정 (Real-time estimation of arc stability in GMAW process)

  • 원윤재;부광석;조형석
    • Journal of Welding and Joining
    • /
    • 제8권1호
    • /
    • pp.31-42
    • /
    • 1990
  • Arc must be stable during welding first of all other factors for obtaining sound weldment, especially in the automation of welding process. Arc stability is somewhat sophisticated phenomenon which is not clearly defined yet. In consumable electrode welding, the voltage and current variation due to metal transfer enables to assess arc stability. Recently, statistical analyses of the voltage and current waveform factors are performed to assess the degress of arc stability which is assessed and controlled by operator's own experience by now. But, considering the increasing need and the trend of automation of welding process, it is necessary to monitor arc stability in real-time. In this sutdy, the modified stability index composed of two voltage and current wvaeform factors (arc time and short circuit time) reduced from four factors (arc time, short circuit time, average arc current and average short circuit current) in Mita's index by the welding electrical circuit modeling is proposed and verified by experiments to be well estimating arc stability in the static sense. Also, the recursive calculation form estimating present arc stability in the dynamic sense is developed for real-time estimation. The results of applying the recursive index during welding show good estimation of arc stability in real-time. Therefore, the results of this study offers the mean for real-time control arc stability.

  • PDF

Couette 흐름현상을 이용한 초고압변압기의 유동대전 기구 연구 (A Study on the Electrification Mechanism in UHV Transformer by Couette Flow)

  • 곽희로;정용기;권동진
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권4호
    • /
    • pp.93-102
    • /
    • 1995
  • The purpose of this paper is to analyze the streaming electrification mechanism (SEM) generated in UHV transformer. This experiment used Couette Charger and interpreted the mechanism hydromechanically and electromagnetically. This work estimated the turbulent core density ($\rho$o) by measuring the short circuit current (isc) and the open circuit voltage (νoc) generated in Couette Charger and also studied the changes of the short circuit (isc), the open circuit voltage (νoc), the turbulent core density ($\rho$o) and the conductivity ($\sigma$) with adding BTA to restrain streaming electrification. as a result adding BTA increased the conductivity of oil and decreased the turbulent core density($\rho$o).

  • PDF

2.5 mm2 HIV에 일반화염 및 DC 단락 전류를 인가하여 생성된 기공의 정량적 분포 해석 (Quantitative Distribution of Created Voids by Applying General Flame and DC Short-circuit Current to 2.5 mm2 HIV)

  • 김승삼;최충석
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.38-42
    • /
    • 2013
  • This study performed the quantitative distribution analysis of created voids to an insulator when applying general flame and DC short-circuit current to 2.5 $mm^2$ HIV (600 V Grade Heat-Resistant Polyvinyl Chloride Insulated Wires). The diameter of cross-section of HIV normal product and the radius of conductor were measured to be 3.3 mm and 1.8 mm. The exterior of HIV exposed to general flame showed severe carbonization and its interior exhibited voids created by dechlorination reaction. This study observed the characteristics that, when the shortcircuit current applied for 2 seconds from a DC 12 V lead battery, the conductor and neighboring insulator were melted, causing the insulator adhering to the conductor. On average, 87 voids were created on 10 mm of the HIV. The average diameter of voids was 0.25 mm. In addition, it was found that, when the short-circuit current applied for 4 seconds, the interior of insulator in contact with conductor severely carbonized and showed exfoliation phenomenon. On average, 47 voids were created, with more voids at the bottom. The average diameter of voids was 0.20 mm. When the short-circuit current for 6 seconds, most parts of upper part of conductor was carbonized, 20 voids were created. The average diameter of voids was measured to be 0.24 mm. It could be seen that the created voids received little influence by the type of energy source and the number of created voids was reduced as the energy supply time increased.

구동코일의 단락환 형상변경에 따른 아크전류와 자속간의 위상차 특성 (Characteristics of the Phase Difference Between Arc-current and Magnetic Field Due to the Shape Variation of the Short-Circuit Ring of the Driving Coil)

  • 정진교;박경엽;신영준;조현호;최승현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.34-36
    • /
    • 1998
  • In these days the hybrid interrupters are widely used for medium voltage class circuit breakers. In the design of the hybrid interrupter, the shape of the short-circuit ring is one of the most important design parameters. Recently the investigation into the phase difference between arc current and magnetic field due to the shape variation of the short circuit ring has been conducted. In this paper, the results of eddy current analyses in the hybrid interrupter and test result are presented.

  • PDF

IEC 표준에 의한 고장전류 계산과 보호협조 (Fault Current Calculation and Coordination by IEC Standards)

  • 손석금
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

고휘도 Short-Arc 램프용 전자식 안정기 설계 및 제작 (The Design and Fabrication of an Electronic Ballast for High Intensity Short-Arc Lamps)

  • 김일권;박대원;이성근;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.304-309
    • /
    • 2005
  • This paper presents an electronic ballast using a step down converter, a low frequency inverter for high intensity short-arc discharge lamp. The proposed ballast is composed of a full-wave rectifier, a step down converter operated as a current source with power regulation and a low frequency inverter with external ignition circuit. The ignition circuit generates high voltage pulse of $3{\sim}5[kV]$ peak, 130[Hz] periodically. Moreover, it is able to reignite at regular intervals by protective circuit. As experimental results on the test, acoustic resonance phenomenon is eliminated by operating the low frequency square wave voltage and current. Lamp voltage, current and consumption power are measured 123.8[V], 8.1[A] and 1,002[W], respectively. It was confirmed that the designed ballast operate the lamp with a constant power.

  • PDF

개구리 피부(皮腐)의 막전위(膜電位) 및 단락전류(短絡電流)에 미치는 Morphine의 영향 (Effects of Morphine on the Transmembrane Potential and the Short Circuit Current of Frog Skin)

  • 채수완;조규박
    • 대한약리학회지
    • /
    • 제20권1호
    • /
    • pp.23-32
    • /
    • 1984
  • 정상 또는 morphine을 처리한 개구리(Rana nigromaculate)의 피부에서 Ussing 등의 방법에 의하여 막전위와 단락전류에 미치는 morphine의 작용과 morphine 작용에 미치는 전해질의 영향을 관찰하여 다음과 같은 성적을 얻었다. 1) Morphine $5{\pm}10^{-3}$은 개구리 피부의 막전위와 단락전류를 현저히 감소시켰으며 약물투여후 60분후에 최고의 효과를 나타냈다. 2) Naloxone $10^{-4}$은 morphine의 막전위 및 단란전류 억제작용을 차단치 못하였다. 3) 영양액내 $Na^+$ 농도감소, $K^+$ 농도증가 및 $Ca^{2+}$농도증가는 morphine의 막전위 및 단란전류 억제작용ㅇ르 현저히 강화하였으며, $Mn^{2+}$첨가는 morphine의 막전위 억제효과만을 강화시켰다. 한편 $Ca^{2+}$ 농도의 감소로써 morphine의 단락전류억제 효과는 현저히 약화되었으며 $Ma^{2+}$농도 감소로써 morphine의 단락전류 억제효과로 더불어 막전위 억제효과도 감약되었다. 4) Morphine 처리 표본에서 막전위와 단락전류는 morphine 처리 초기에 일시적인 감소를 일으킨 후 증가하여 morphine 처리 $4{\sim}8$일에는 대조군에 비하여 현저히 상승하였다. 또한 morphine의 막전위 및 단락전류 억제효과에 있어서도 morphine처리 $1{\sim}2$일에는 morphine의 억제효과가 강화되나 morphine의 처리 4 또는 8일에는 현저히 약화되었다. 이상의 실험성적으로 morphine의 약물내성을 포함한 그 약리적작용이 생체막에서의 전해질수송 또는 전해질 투과성에 영향을 미쳐 초래될 수 있음을 시사하는 것으로 추측하였다.

  • PDF

Modeling of Solar Radiation Using Silicon Solar Module

  • Kim, Joon-Yong;Yang, Seung-Hwan;Lee, Chun-Gu;Kim, Young-Joo;Kim, Hak-Jin;Cho, Seong-In;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • 제37권1호
    • /
    • pp.11-18
    • /
    • 2012
  • Purpose: Short-circuit current of a solar module that is widely used as a power source for wireless environmental sensors is proportional to solar radiation although there are a lot of factors affecting the short-circuit current. The objective of this study is to develop a model for estimating solar radiation for using the solar module as a power source and an irradiance sensor. Methods: An experiment system collected data on the short-circuit current and environmental factors (ambient temperature, cloud cover and solar radiation) during 65 days. Based on these data, two linear regression models and a non-linear regression model were developed and evaluated. Results: The best model was a linear regression model with short-circuit current, angle of incidence and cloud cover and its overall RMSE(Root Means Square Error) was 66.671 $W/m^2$. The other linear model (RMSE 69.038 $W/m^2$) was also acceptable when the cloud cover data is not available.