• 제목/요약/키워드: Short Columns

검색결과 194건 처리시간 0.022초

Tests on fiber reinforced concrete filled steel tubular columns

  • Gopal, S. Ramana;Devadas Manoharan, P.
    • Steel and Composite Structures
    • /
    • 제4권1호
    • /
    • pp.37-48
    • /
    • 2004
  • This paper deals with the strength and deformation of both short and slender concrete filled steel tubular columns under the combined actions of axial compression and bending moment. Sixteen specimens were tested to investigate the effect of fiber reinforced concrete on the ultimate strength and behavior of the composite column. The primary test parameters were load eccentricity and column slenderness. Companion tests were also undertaken on eight numbers of similar empty steel tubes to highlight the synergistic effects of composite column. The test results demonstrate the influence of fiber reinforced concrete on the strength and behavior of concrete filled steel tubular columns.

Effect of axial loading conditions and confinement type on concrete-steel composite behavior

  • Nematzadeh, Mahdi;Fazli, Saeed
    • Computers and Concrete
    • /
    • 제25권2호
    • /
    • pp.95-109
    • /
    • 2020
  • This paper aims to analytically study the effect of loading conditions and confinement type on the mechanical properties of the concrete-steel composite columns under axial compressive loading. The axial loading is applied to the composite columns in the two ways; only on the concrete core, and on the concrete core and steel tube simultaneously, which are called steel tube-confined concrete (STCC) and concrete-filled steel tube (CFST) columns, respectively. In addition, the confinement is investigated in the three types of passive, short-term active and long-term active confinement. Nonlinear finite element 3D models for analyzing these columns are developed using the ABAQUS program, and then these models are verified with respect to the recent experimental results reported by the authors on the STCC and CFST columns experiencing active and passive confinements. Axial and lateral stress-strain curves as well as the failure mode for qualitative verification, and compressive strength for quantitative verification are considered. It is found that there is a good consistency between the finite element analysis results and the experimental ones. In addition, a parametric study is performed to evaluate the effect of axial loading type, prestressing ratio, concrete compressive strength and steel tube diameter-to-wall thickness ratio on the compressive behavior of the composite columns. Finally, the compressive strength results of CFST specimens obtained via the finite element analysis are compared with the values specified by the international codes and standards including EC4, CSA, ACI-318, and AISC, with the results showing that ACI-318 and AISC underestimate the compressive strength of the composite columns, while EC4 and CSA codes present overestimated values.

고성능 유리섬유로 보강된 해상장대교량 교각의 보강성능평가 (Performance Evaluation of Long Span Bridge Columns Strengthened with High-Performance Glass Fiber)

  • 장준호;장광석;이재욱
    • 해양환경안전학회지
    • /
    • 제16권1호
    • /
    • pp.125-133
    • /
    • 2010
  • 기존의 해상교량 기둥의 외부보강에 따른 연구들은 현재까지 주로 중앙점 재하에 따른 성능을 평가하였다. 하지만, 장대교량의 기둥은 정확한 중심축을 기준으로 축하중을 받는 경우와 편심으로 인한 큰 모멘트가 동시에 작용하는 경우가 많이 발생한다. 이 연구에서는 해상장대교량의 고강도 철근콘크리트 기둥의 하중재하 위치와 2가지의 보강 재료인 탄소섬유 및 고성능 유리섬유를 각각 보강하여 그 효과를 분석하였다. 실험에 사용된 12개의 기둥 실험체는 모두 같은 크기로 제작 및 실험을 하였다. 그 중 6개 실험체의 횡보강 철끈은 띠철근으로 배근하였으며, 그 외 6개의 실험체는 나선철근으로 매끈하였다. 그리고 각각 3겹의 탄소섬유 및 고성능 유리섬유를 적용하여 감싸기 방법으로 보강하였다. 실험변수는 하중재하 위치에 따른 철근의 보강행태 및 보강재료가 고려되었다. 실험결과, 편심축에 따른 하중재하 기둥부재는 중심축 하중재하에 비해 최대 파괴하중이 감소하였지만 고성능 유리섬유를 보강한 기둥부재는 축하중 및 편심하중에서 탄소섬유를 보강한 경우보다 내력과 연성이 우수하였다.

Experimental study and calculation of laterally-prestressed confined concrete columns

  • Nematzadeh, Mahdi;Fazli, Saeed;Hajirasouliha, Iman
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.517-527
    • /
    • 2017
  • In this paper, the effect of active confinement on the compressive behaviour of circular steel tube-confined concrete (STCC) and concrete-filled steel tube (CFST) columns is investigated. In STCC columns the axial load is only applied to the concrete core, while in CFST columns the load is carried by the whole composite section. A new method is introduced to apply confining pressure on fresh concrete by laterally prestressing steel tubes. In order to achieve different prestressing levels, short-term and long-term pressures are applied to the fresh concrete. Three groups of STCC and CFST specimens (passive, S-active and L-active groups) are tested under axial loads. The results including stress-strain relationships of composite column components, secant modulus of elasticity, and volumetric strain are presented and discussed. Based on the elastic-plastic theory, the behaviour of the steel tube is also analyzed during elastic, yielding, and strain hardening stages. The results show that using the proposed prestressing method can considerably improve the compressive behaviour of both STCC and CFST specimens, while increasing the prestressing level has insignificant effects. By applying prestressing, the linear range in the stress-strain curve of STCC specimens increases by almost twice as much, while the improvement is negligible in CFST specimens.

Simplified stress-strain model for circular steel tube confined UHPC and UHPFRC columns

  • Le, An H.;Ekkehard, Fehling;Thai, Duc-Kien;Nguyen, Chau V.
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.125-138
    • /
    • 2018
  • The research on the confinement behavior of ultra high performance concrete without and with the use of steel fibers (UHPC and UHPFRC) has been extremely limited. In previous studies, authors experimentally investigated the axially compressive behavior of circular steel tube confined concrete (STCC) short and intermediate columns with the employment of UHPC and UHPFRC. Under loading on only the concrete core, the confinement effect induced by the steel tube was shown to significantly enhance the utimate stress and its corresponding strain of the concrete core. Therefore, this paper develops a simplified stress - strain model for circular STCC columns using UHPC and UHPFRC with compressive strength ranging between 150 MPa and 200 MPa. Based on the regression analysis of previous test results, formulae for predicting peak confined stress and its corresponding strain are proposed. These proposed formulae are subsequently compared against some previous empirical formulae available in the literature to assess their accuracy. Finally, the simplified stress - strain model is verified by comparison with the test results.

Predicting the axial load capacity of high-strength concrete filled steel tubular columns

  • Aslani, Farhad;Uy, Brian;Tao, Zhong;Mashiri, Fidelis
    • Steel and Composite Structures
    • /
    • 제19권4호
    • /
    • pp.967-993
    • /
    • 2015
  • The aim of this paper is to investigate the appropriateness of current codes of practice for predicting the axial load capacity of high-strength Concrete Filled Steel Tubular Columns (CFSTCs). Australian/New Zealand standards and other international codes of practice for composite bridges and buildings are currently being revised and will allow for the use of high-strength CFSTCs. It is therefore important to assess and modify the suitability of the section and ultimate buckling capacities models. For this purpose, available experimental results on high-strength composite columns have been assessed. The collected experimental results are compared with eight current codes of practice for rectangular CFSTCs and seven current codes of practice for circular CFSTCs. Furthermore, based on the statistical studies carried out, simplified relationships are developed to predict the section and ultimate buckling capacities of normal and high-strength short and slender rectangular and circular CFSTCs subjected to concentric loading.

철근콘크리트 기둥의 좌굴거동에 관한 실험적 연구 (Experiments for the Buckling Behavior of Reinforced Concrete Columns)

  • 조성찬;장정수;김진근;김윤용;김광석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.284-289
    • /
    • 1993
  • To analyze the effects of compressive strength of concrete and longitudinal steel ratio on buckling behavior of columns, 36tied reinforced concrete columns with hinged ends were tested. The 100mm square cross section was used and the amount of eccentricity was 10mm. The compressive strengths of column specimens with slenderness ratios of 15, 30 and 50 were 202, 513 and 752 kg/$\textrm{cm}^2$. The longitudinal steel ratio of columns with bending about a section diagonal and about a principal axis were 2.85%(4-D10). The ratio of ultimate load capacity to that of short column with the same eccentricity was much decreased at high slenderness ratio with increasing the compressive strength of concrete. And the lateral displacement of column at the ultimate load was decreased as the strength was increased. These are due to that at high slenderness ratio, the load capacity and behavior of column are affected by flexural rigidity. And, it was also found that for the same quantity of confining steel and level of axis load, there is little difference between the flexural strength for bending about a section diagonal and for bending about principal axis.

  • PDF

Compressive and flexural behaviour of recycled aggregate concrete filled steel tubes (RACFST) under short-term loadings

  • Yang, You-Fu;Han, Lin-Hai
    • Steel and Composite Structures
    • /
    • 제6권3호
    • /
    • pp.257-284
    • /
    • 2006
  • The behaviour of hollow structural steel (HSS) stub columns and beams filled with normal concrete and recycled aggregate concrete (RAC) under instantaneous loading was investigated experimentally. A total of 40 specimens, including 30 stub columns and 10 beams, were tested. The main parameters varied in the tests were: (1) recycled coarse aggregate (RCA) replacement ratio, from 0 to 50%, (2) sectional type, circular and square. The main objectives of these tests were threefold: first, to describe a series of tests on new composite columns; second, to analyze the influence of RCA replacement ratio on the compressive and flexural behaviour of recycled aggregate concrete filled steel tubes (RACFST), and finally, to compare the accuracy of the predicted ultimate strength, bending moment capacity and flexural stiffness of the composite specimens by using the recommendations of ACI318-99 (1999), AIJ (1997), AISC-LRFD (1999), BS5400 (1979), DBJ13-51-2003 (2003) and EC4 (1994).

강섬유로 보강된 RC 단주의 전단특성 (Shear Characteristics of RC Short Column Strengthened with Steel Fiber)

  • 장극관;이현호;양승호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.157-162
    • /
    • 2001
  • The purpose of this study is to investigate the enhancement of shear capacity according to steel fiber contents in RC short columns. Lateral force resistance test was performed with the parameters of steel fiber contents in concrete volume. From the test results, shear and ductility capacity was improved with steel fiber contents Increased. In addition, an optimal steel fiber content was evaluated as a 1.5 % of concrete volume.

  • PDF

밀양 영남루 연혁 및 건축형식 변천에 관한 연구 (A Study on the Historic Changes of Yungnam-Ru in Historic Periods and Architectural Building Forms)

  • 이호열
    • 건축역사연구
    • /
    • 제9권1호
    • /
    • pp.7-25
    • /
    • 2000
  • The purpose of this study is focused to the historic changes of Yungnam-Ru(嶺南樓), which are based on the site layout, and architectural forms in architectural building history and historic periods analyzed with the historic reference, paintings, and photos. This study is to search the alteration of the types of axis and the formation of spaces in Yungnam-Ru which is the Ru-Gak(樓閣) The conclusion of the architectural changes from the historic period and architectural form which is the belows. The first Yungnam-Ru by name had been used to be called, before it was re-called Yungnam-Ru by Kim Ju in 1365. Therefore, the hypothesis in naming Yungnam-Ru form assumption that the building under the name of Yungnam-Ru was re-named by Kim Ju from the Old Budist Temple called Yungnam-Sa, should re-considered in history. The second, it is considered that Milyang-Sibyi-Kyungdo(密陽十二景圖) as the painting can only be seen the site layout in 1542. It could be compared the differences of the site layouts from in 1542 to the present time. At that time Nyungpadang(凌派堂) was connected the main buildings called Yungnam-Ru Chimrudang(沈流堂),building was seperated with the Yungnam-Ru at that period. In 1542, the main Building(Yungnam-Ru) was consist of 5 spans of columns(from the front) and 2 spans of columns(from the side). Now, the main Building(Yungnam-Ru) has the 5 spans of columns from the front, and two spans of columns short from the side, compared to the present facade. At the past, Chimrudang(building) has the two spans of columns and one span of columns short, compared to the present facade. The third, It supposed that main building, Nyungpadang and Chimrudang in the composite of facade was connected with Wolrang(月廊) and Hunrang(軒廊) after invatioin from japan in 1592. 1844, (Chosun dynasty, Hunjong 10) the Yungnam-Ru was re-builted by maintaining the same concept in site layout of the past, and finally the three buildings was put together with Wolrang and Hunrang. As a result, the plan of the Yungnam-Ru was expanded with many aspects. From 1542 to 1844, the present site-layout gradually completed with three buildings which was spatially connected. The forth, in the middle age of Chosun dynasty, after added Gaeksa(客舍), the building is for the government officer staying temporally from outside province) in the site, the site layout was greatly changed with volume of building. In 1844, the Yungnam-Ru as the Nugak belongs to Miljukwan(密州館) was expanded spacially and formally. After that time, the burned buildings could not have been re-built because of aspects in government ability and economical ability.

  • PDF