Protection of the MMCs of HVDC Transmission Systems against DC Short-Circuit Faults

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.242-252
    • /
    • 2017
  • This paper deals with the blocking of DC-fault current during DC cable short-circuit conditions in HVDC (High-Voltage DC) transmission systems utilizing Modular Multilevel Converters (MMCs), where a new SubModule (SM) topology circuit for the MMC is proposed. In this SM circuit, an additional Insulated-Gate Bipolar Translator (IGBT) is required to be connected at the output terminal of a conventional SM with a half-bridge structure, hereafter referred to as HBSM, where the anti-parallel diodes of additional IGBTs are used to block current from the grid to the DC-link side. Compared with the existing MMCs based on full-bridge (FB) SMs, the hybrid topologies of HBSM and FBSM, and the clamp-double SMs, the proposed topology offers a lower cost and lower power loss while the fault current blocking capability in the DC short-circuit conditions is still provided. The effectiveness of the proposed topology has been validated by simulation results obtained from a 300-kV 300-MW HVDC transmission system and experimental results from a down-scaled HVDC system in the laboratory.

교류발전기 병렬운전시 과도현상 해석에 관한 연구 (A Study on the Transient Phenomenon Analysis at the instant of Parallel Running for A.C. Generators)

  • 오세진;김현수;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권5호
    • /
    • pp.1065-1075
    • /
    • 2001
  • It is common knowledge amongst electrical and marine engineers that short-circuit in electrical system may cause large mechanical torque on generator and prime mover However, it is not so widely known that the faulty synchronizing of generators may cause even higher torques than that of short-circuit. In this study, the transient phenomena related to the parallel running of synchronous generators are analyzed and the exact computer simulation method is proposed. In result, maximum transient torque and current take place in case of $120^{\circ}$ voltage angle difference between Master and Slave and that may develop higher torque than the short-circuit according to a condition of synchronizing. When synchronizing in power system using only two generators higher torque and current occur Master, but using multimachine system those occur to Slave. The short-circuit of marine generator does not happen frequently but faulty synchronizing sometimes takes place, therefore, it is necessary for designers to consider these phenomena.

  • PDF

GMA용접 시스템의 동적 거동에 대한 해석 (Analysis of Dynamic Behavior in GMAW System)

  • 이재영;최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • 제18권5호
    • /
    • pp.41-48
    • /
    • 2000
  • Dynamic behaviors of the GMAW system are simulated using the short-circuit transfer model and the characteristic equations fir the power supply, wire system and arc. The conventional wire equation, which relates the rate change of the wire extension to the wire feed rate and melting rate, is modified to include effects of the molten drop attached at the wire tip. The modified wire equation describes behaviors of the GMAW system more precisely and provides information about the initial bridge volume for short-circuit transfer. The proposed short-circuit model predicts the variation of parameters such as the current, voltage, short-circuit frequency and time considering the effects of the surface tension and electromagnetic force due to current. The calculated results are in broad agreements with the experimental results under the argon shielding condition.

  • PDF

회전기의 기여에 의한 시변성의 순간전압강하 예측에 관한 연구 (Investigation of the Estimation of Time-Varying Voltage Sags Considering the Short Circuit Contributions of Rotating Machines)

  • 윤상윤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권6호
    • /
    • pp.315-322
    • /
    • 2005
  • In this article, 1 would like to explore the estimation method of time-varying voltage sags in large industrial systems considering the short circuit contributions of rotating machines. For the power distribution system of KEPCO(Korea Electric Power Corporation), the magnitude of initial symmetrical short circuit current is generally not changed. However, in industrial systems which contain a number of rotating machines, the magnitude of voltage sag is generally changed from the initial to the clearing time of a fault due to the decreasing contribution of rotating machines for a fault current. The time-varying characteristics of voltage sags can be calculated using a short circuit analysis that is considered the time-varying fault currents. For this, the prediction formulations of time-varying voltage sags are proposed using a foreign standard. The proposed method contains the consideration of generator and motor effects. For the test of proposed formulations, a simple system of industrial consumer is used for the comparison conventional and proposed estimation method of voltage sag characteristics.

보조전원장치의 단락부하 차단기 개방을 위한 제어방법 (Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply)

  • 황광철;조국춘;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF

단락발전기 용 여자장치의 조작과 기능에 대한 고찰 (The study for function and operation of the excitation equipment for short circuit generator)

  • 김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.735-736
    • /
    • 2008
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, CLR, Back Up Breaker, Making Switch and Excitation Equipment etc. Gradually an allowable tolerance of the short circuit test voltage is become smaller by the standards for short circuit test. The excitation equipment of short circuit generator is very important for test voltage is adjusted by the excitation equipment. Especially the excitation equipment must be possessed character of exactitude, durability and inalterability because some times around 10,000 times opening and closing short circuit test is requested by clint, which must be done within one minute. The purpose of this study for function and operation of the excitation equipment which rated DC voltage is 1,000V, rated DC current is 300A, rated out put is 30kW and type is YNEX 97S-441/609, is to help operation of short circuit generator.

  • PDF

대형의료기기의 회로 단락시 전류흐름에 대한 시뮬레이션 연구 (A study on simulation to current flow by short circuit of medical machine)

  • 최도순
    • 한국정보전자통신기술학회논문지
    • /
    • 제5권4호
    • /
    • pp.211-215
    • /
    • 2012
  • 대형의료기기는 환자 진단과 치료 행위에 있어서 매우 중요한 기기이다. 이런 대형의료기기를 사용하여 환자를 진단 또는 치료할 때 의료기기의 회로 내에서 갑작스런 전류의 변화는 회로의 단락 등 매우 심각한 문제를 일으킨다. 특히 회로 내에서 전류변환기에 큰 부하가 걸리게 한다. 이것으로 인해 변환기는 포화에 이르게 되는데 이것은 철심코일 인턱터의 magnetic curve에 기인한다. 이와 같이 변환기가 saturate에 이르게 되면 1차 측과 2차 측의 변환 비율이 깨지게 되고 회로가 단락되는 문제가 발생하게 된다. 이 논문 에서는 대형의료기기에 사용되는 current 변환기의 입력 측에 갑작스런 큰 전류 변화가 발생 했을 때 일어나는 그에 따른 포화 상태와 그의 2차 측 전류의 변화를 simulation 해본다.

휴대용 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 퓨즈 가용체 설계 (Design of Fuse Elements of Current Sensing Type Protection Device for Portable Secondary Battery Protection System)

  • 강창룡;김은민
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1619-1625
    • /
    • 2018
  • Portable electronic devices secondary batteries can cause fire and explosion due to micro-current change in addition to the situation of short-circuit inrush current, safety can not be secured with a general operation limited current fuse. Therefore, in secondary battery, it is necessary for the protector to satisfy both the limit current type operation in the open-short-circuit inrush current and the current detection operation characteristic in the micro current change situation and for this operation, a fuse for the current detection type secondary battery protection circuit can be applied. The purpose of this study is to design a protection device that operates stably in the hazardous situation of small capacity secondary battery for portable electronic devices through the design of low melting fuse elements alloy of sensing type fuse and secures stability in abnormal current state. As a result of the experiment, I-T and V-T operation characteristics are satisfied in a the design of the alloy of the current sensing type self-contained low melting point fuse and the resistance of the heating resistor. It is confirmed that it can prevent accidents of short circuit over-current and micro current change of secondary battery.

ITO/InP 태양전지 제작에 응용된 sulfur passivation의 효과 (The effects of sulfur passivation on the performance of ITO/InP solar cells)

  • 이영철;한교용
    • 전자공학회논문지D
    • /
    • 제34D권9호
    • /
    • pp.50-55
    • /
    • 1997
  • In order to improve the electrical performance of ITO/InP solar cells, sulfur passivation technique was employed using (N $H_{4}$)$_{2}$ $S_{x}$ solution. Passivation effects were analyzed by measuring the short circuit current density ( $J_{sc}$ ) of solar cells and photoluminescence (PL) of ITO/InP interfaces. This paper firstly reports the sulfur passivation effects by investigating the correlation between the PL intensity and the short circuit current. Generally, PL intensity and the short circuit current of sulfur passivated sampels wer eincreased, and showed the same trend. Especially, samples prepared at 60.deg. C (N $H_{4}$)$_{2}$ $S_{x}$ solution exhibited the highest $J_{sc}$ and PL intensity. These results demonstrated that the short circuit currents was influenced by the ITO/InP interface states.

  • PDF

경년열화에 따른 배선용 차단기류의 고장점 분석 연구 (A Study on Failure Analysis of Low Voltage Breakers with Aging)

  • 조한구;이운용;이유정;이해기;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.501-502
    • /
    • 2006
  • In this paper, new and aging sample of MCCB and ELCB are investigated the main performance test such as short circuit test, mechanical and electrical endurance test, dielectric test and surge current test. The surface conditions of new and aging sample are analyzed by SEM, TGA and DSC. The ELCB occurred badness mainly in short circuit test and surge current test. The badness cause of short circuit test was confirmed due to imperfect contact of contact part.

  • PDF