• Title/Summary/Keyword: Shock test

Search Result 980, Processing Time 0.022 seconds

Elastic Modulus Measurement of a Large Size Digital TV Display Unit (대형 Digital TV용 Display Unit의 강성 측정)

  • Kim Chang-Hoi;Moon Seong-In;Choi Jae-Boons;Kim Young-Jin;Lee Jeoung-Gwen;Koo Ja-Choon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.115-122
    • /
    • 2005
  • As the digital TV markets rapidly growing, many manufacturers introduce large size flat screen TV units. There are two different display types available to large size models which are plasma and TFT-LCD. Since both are constructed with thin large panels that are mostly fragile to even moderate mechanical shock inputs. Some large size panels are severely resonated by the acoustic sound generated TV which deteriorates video quality. Recognizing the potential problems of large displays, accurate measurement of the panels is to be an essential task for the reliable design. Measurement of mechanical properties of a thin large crystallized panel such as TFT-LCD display with traditional material testing equipments is challenging. Since TFT-LCDs are constructed with combination of brittle glass panels, polymer sheets, and liquid crystal, their properties are not only anisotropic but also usually non-linear. Accurate measurement of the properties often requires very expensive facilities. Especially when the size of the test sample is as large as 40-inch or wider, direct measurement cost is prohibitive. Even worse, machining of the large TFT-LCD to make a smaller size specimen that could be fit into a material tester is not possible because of liquid crystal leakage. A new method fer the measurement of elastic modulus of large TFT-LCD panel is presented in this article. The suggested method provides a simple, economic, and user-friendly way fer measuring the elastic modulus of large panels with considerable level of accuracy.

Study on the Thermal Design of Nuclear Battery for Lunar Mission (한국형 달 탐사용 원자력전지의 열제어 구조 연구)

  • Hong, Jintae;Son, Kwang-Jae;Kim, Jong-Bum;Park, Jong-Han;Ahn, Dong-Gyu;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.4
    • /
    • pp.271-277
    • /
    • 2016
  • For a stable electric power supply in the space, nuclear batteries have been used as the main power source in a spacecraft owing to their long lifetime and high reliability. In accordance with the plan for lunar mission in Korea, nuclear batteries will supply electricity to the rover that needs to be developed. According to the information about the estimated payload, Korea Atomic Energy Research Institute started with the conceptual design based on the previous studies in USA and Russia. Because a nuclear battery converts the decay heat of the radioisotope into electricity, thermal design, radiation shield, and shock protection need to be considered. In this study, two types of nuclear batteries, radial type and axial type, were designed according to the alignment of the thermoelectric module. Heat transfer analyses were performed to compare their thermoelectric efficiency, and test mockups were fabricated to evaluate their performances.

Improvement of Oxidative Resistance for C/C Composite Coated (졸-겔법으로 알루미나를 도포한 탄소/탄소 복합재의 산화 억제효과)

  • Ju, Hyeok-Jong;Choe, Don-Muk;Kim, Yeong-Guk;Gwon, Ho-Gil
    • Korean Journal of Materials Research
    • /
    • v.3 no.4
    • /
    • pp.372-380
    • /
    • 1993
  • In order to improve the oxidative resistance of carbon/carbon composites, aluminium-isopropoxide and aluminium-tri-sec-butoxide sol were coated on the surface of 2D--carbon/carbon composiles and the effects uf coating were investigated. The effects of oxidative resistance were dominant in the case of catalyst/alkoxide mole ratio, 0.07, and $H_2O$/alkoxide mole ratio, 100. Through the dynamic TGA analysis with the heating rate of 20%/min, oxidative initiation tempera~ ture was enhanced about $80^{\circ}C$. The oxidative resistance effects of alkoxide sol were improved according to the times of coating. Also the 20% weight loss time of coated samples by TGA analysis was 20% better than that of un~ coated samples. The thickness of 1^{st} coated layer was about 3${\mu}$m and that of $2^{nd}$ and $3^{nd}$ coated layers was about respectively 4~5${\mu}$m and the weight loss were increased with the increasing of thermal shock test times.

  • PDF

A study on the brazed bonding of alumina ceramic to aluminum in the air atmosphere (알루미나($Al_2O_3$)세라믹과 알루미늄(A1050)과의 대기중 브레이징 접합에 관한 연구)

  • 최영국;박성현;김윤해;김영식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.50-61
    • /
    • 1995
  • In recent years, many ceramic researchers have discoved various methods of joining ceramic to metal. However, most of these joining methods are perfomed under vacuum and pressured circumstances. So, when we join ceramic to metal,the proceedings are very complicated and require a very high cost. The purpose of this study is to develop a new joining method of an alumina ceramic to an aluminum metal in air atmosphere. The joining condition, such as copper metallizing, nickel plating, brazing, etc. was investigated through the shear strength test of the trial joint. The results obtained from the above experimenta are summarized as follows : 1) In the case of the $Al_2O_3$/$Al_2O_3$joint, the shear strength of the joint was affected by the various foctor such as kaolin content, copper metallizing thickness, firing temperature, firing time. 2) The better shear strength of the $Al_2O_3$/Al joint was obtained when Ni plating was conducted under higher current density than existing plating condition. 3) The shear strength of the $Al_2O_3$/Al joint increases with the Ni plating thickness is confined to the range of this paper. 4) The shear strength of the thermal-shocked specimen($Al_2O_3$/Al joint) was far more deteriorated than that of the as-bonded specimen.

  • PDF

Development of Load Cell Using Fiber Brags Grating Sensors and Differential Method for Structural Health Monitoring (구조 건전성 모니터링을 위한 광섬유 브래그 격자 센서와 차동법을 적용한 로드셀 개발)

  • Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.299-307
    • /
    • 2009
  • Emerging fiber optic sensor technologies have shown great potential to overcome the difficulties associated with conventional sensors. Fiber optic sensors are immune to EM noise and electric shock and thus can be used in explosion-prone areas. Several kinds of fiber optic sensors have been developed over the last two decades to take advantage of these merits. There have also been many field applications of fiber optic sensors for structural health monitoring as NDT/HDE. However, very few sensors, particularly a load cell have been successfully commercialized. This Paper Presents a load cell using fiber Bra99 gra1ing (FBG) sensors. The shape of the load cell is a link type, and three FBG sensors are used for measuring strains at three different points. Especially, these strains are processed with a differential method in order to exclude common mode noise such as temperature. Moreover, the sensitivity, the linearity and the resolution of the load cell were successfully verified from the experiment of tension test.

Effects of Banhahubak-Tang Extract (BHTe) on Sociopsychological Stress (반하후박탕(半夏厚朴湯)의 사회·심리적 스트레스에 대한 실험적 연구(實驗的 硏究))

  • Won, Ho-Young;Kim, Ha-Na;Song, Young-Gil;Kim, Kyeong-Ok
    • Journal of Oriental Neuropsychiatry
    • /
    • v.25 no.3
    • /
    • pp.297-310
    • /
    • 2014
  • Objectives: This study is designed to investigate the effects of Banhahubak-Tang Extract (BHTe) on stress. Methos: BHTe was fed to ICR male mice ($20{\pm}2g$) orally with the dose of 100 mg/kg/day for five days. Mice were then exposed to sociopsychological stress by observing foot shock stressed mice for one hour for five days while restrained. Results: 1) The BHTe-administered group showed a tendency of decreasing of serum corticosterone secretion compared with the control group. 2) The BHTe-administered group showed an increase in noradrenalin secretions in the dorsal cortex of the brain, but it was not significant. 3) BHTe administration had no effect on the brain level of lipid peroxidation. 4) BHTe administration decreased the serum level of lipid peroxidation. 5) BHTe administration decreased the Cu,Zn-SOD in the brain. 6) BHTe administration had no effect on catalase activity in the brain. 7) BHTe administration had no effect on the brain level of GSH. 8) BHTe administration increased the serum level of DPPH free radical scavenging activity, but not significantly enough to make a comparison with BHT. 9) The elevated plus-maze test is designed to detect the effect of anxiolytic drugs. The BHTe group showed a significant increase in latency time. Conclusions: These results suggest that BHTe can effectively rid the subject of the effects of sociopsychological stress.

Design of CPR Artifact Removal Algorithm Based on Orthogonal Function using LMS Adaptive Filter (LMS 적응필터를 이용한 직교 함수 기반의CPR 잡음 제거 알고리즘 설계)

  • Lim, Eunho;Nam, Dong-Hoon;Myoung, Hyoun-seok;Kang, Dong-Won;Jeon, Dae-Keun;Yoon, Young-Ro;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.153-160
    • /
    • 2016
  • This study proposes an algorithm for removal of CPR artifact in order that automated external defibrillator (AED) can effectively diagnose ECG rhythm during cardiopulmonary resuscitation (CPR). Current AED required to interrupt chest compression for reliable rhythm analysis to avoid the effect of artifacts produced by CPR. However even temporarily interruption of chest compression during CPR adversely affects the probability of restoration of spontaneous circulation (ROSC) and survival after the delivery of the shock. Therefore, we proposed a method for removal of CPR artifacts using least mean square (LMS) filter. The removal of the CPR artifacts would enable compressions to continue during AED rhythm analysis, thereby increasing the likelihood of resuscitation success. It was tested on 31 segments of shockable and 300 segments of non-shockable ECG signals recorded from three pigs during CPR. In the result, sensitivity (Se) and specificity (Sp) analysis on the test segments showed values of Se = 3.2%, Sp = 66.0% and Se = 96.8%, Sp = 98.7% in the case of unfiltered and filtered signals during CPR. In conclusion, it was shown that the proposed method can be a useful tool to exactly diagnose the ECG rhythm during the CPR.

A New Steady Approach to Predict the Transonic Buffet Onset (천음속 버펫 발단 예측을 위한 새로운 정상 접근 방법)

  • Jeong, In-Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.5
    • /
    • pp.12-18
    • /
    • 2006
  • A new steady approach has been developed to predict the transonic buffet onset of a high speed aircraft. In this paper, the flow is assumed to be steady for the buffet onset. The present study involves the analysis of a distinct change in the variation of various static aerodynamic parameters. These distinct changes indicates the onset of transonic buffet. Among the various aerodynamic parameters considered in this study, the variation in the center of pressure has shown to provide a clearest indicator of transonic buffet onset. This new steady approach can be applied to predict the transonic buffet onset for airfoils with shock induced separation bubble and for large swept wings with small aspect ratios. Good agreements have been obtained compared with unsteady wind tunnel buffet test data. Based on the results obtained the new steady approach, it can be newly suggested that the distinct slope changes of the center of pressure curve can be used as an indicator of buffet onset for the steady experimental method on a full aircraft configuration.

Glutathione Reductase from Oryza sativa Increases Acquired Tolerance to Abiotic Stresses in a Genetically Modified Saccharomyces cerevisiae Strain

  • Kim, Il-Sup;Kim, Young-Saeng;Yoon, Ho-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.11
    • /
    • pp.1557-1567
    • /
    • 2012
  • Glutathione reductase (GR, E.C. 1.6.4.2) is an important enzyme that reduces glutathione disulfide (GSSG) to a sulfydryl form (GSH) in the presence of an NADPH-dependent system. This is a critical antioxidant mechanism. Owing to the significance of GR, this enzyme has been examined in a number of animals, plants, and microbes. We performed a study to evaluate the molecular properties of GR (OsGR) from rice (Oryza sativa). To determine whether heterologous expression of OsGR can reduce the deleterious effects of unfavorable abiotic conditions, we constructed a transgenic Saccharomyces cerevisiae strain expressing the GR gene cloned into the yeast expression vector p426GPD. OsGR expression was confirmed by a semiquantitative reverse transcriptase polymerase chain reaction (semiquantitative RT-PCR) assay, Western-blotting, and a test for enzyme activity. OsGR expression increased the ability of the yeast cells to adapt and recover from $H_2O_2$-induced oxidative stress and various stimuli including heat shock and exposure to menadione, heavy metals (iron, zinc, copper, and cadmium), sodium dodecyl sulfate (SDS), ethanol, and sulfuric acid. However, augmented OsGR expression did not affect the yeast fermentation capacity owing to reduction of OsGR by multiple factors produced during the fermentation process. These results suggest that ectopic OsGR expression conferred acquired tolerance by improving cellular homeostasis and resistance against different stresses in the genetically modified yeast strain, but did not affect fermentation ability.

Hearing Ability of Bambooleaf wrasse Pseudolabrus japonicus caught in the coast of Jeju (제주 연안에서 어획된 황놀래기의 청각 능력)

  • Choi, Chan-Moon;Park, Yong-Seok;Lee, Chang-Heon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.6
    • /
    • pp.1381-1388
    • /
    • 2013
  • In order to improve the availability of underwater sound by the fundamental data on the hearing ability, the auditory thresholds for the bambooleaf wrasse pseudolabrus japonicus were determined at 80Hz, 100Hz, 200Hz, 300Hz, 500Hz and 800Hz by heartbeat conditioning method using pure tones coupled with a delayed electric shock. The audible range of the bambooleaf wrasse extended from 80Hz to 800Hz with the best sensitivity around 100Hz and 200Hz. In addition, the auditory thresholds over 300Hz increased rapidly. The mean auditory thresholds of the bambooleaf wrasse at the test frequencies, 80Hz, 100Hz, 200Hz, 300Hz, 500Hz and 800Hz were 100dB, 95.1dB, 94.8dB, 109dB, 121dB and 125dB, respectively. Auditory critical ratios for the bambooleaf wrasse were measured using masking stimuli with the spectrum level range of about 70, 74, 78dB (0dB re $1{\mu}Pa/\sqrt{Hz}$). According to white noise level, the auditory thresholds increased as compared with thresholds in a quiet background noise. The Auditory masking by the white noise spectrum level was stared over about 60dB within 80~300Hz. Critical ratios to be measured at frequencies from 80Hz to 300Hz were minimum 33dB and maximum 39dB.