• Title/Summary/Keyword: Ship structures

Search Result 592, Processing Time 0.02 seconds

A Study of variables Related to Nursing Productivity (간호생산성에 관한 연구: 관련변수의 검증을 중심으로)

  • 박광옥
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.4
    • /
    • pp.584-596
    • /
    • 1994
  • The objective of the study is to explore the relationships between the variables of nursing productivity on the framework of system del in the tertiary university based care hospital in Korea. Productivity is basically defined as the relation-ship between inputs and outputs. Under the proposition that the nursing unit is a system that produces nursing care output using personal and material resources through the nursing intervention and nursing care management. And this major conception of nursing productivity system comproises input, process and output and feed-back. These categorized variables are essential parts to produce desirable and meaningful out-put. While nursing personnel from head nurse to staff nurses cooperate with each other, the head nurse directs her subordinates to achieve the goal of nursing care unit. In this procedure, the head nurse uses the leadership of authority and benevolence. Meantime nursing productivity will be greatly influenced by environment and surrounding organizational structures, and by also the operational objectives, the policy and standards of procedures. For the study of nursing productivity one sample hospital with 15 general nursing care units was selected. Research data were collected for 3 weeks from May 31 to June 20 in 1993. Input variables were measured in terms of both the served and the server. And patient classification scores were measured drily by degree of nursing care needs that indicated patent case-mix. And also nurses' educational period for profession and clinical experience and the score of nurses' personality were measured as producer input variables by the questionnaires. The process varialbes act necessarily on leading input resources and result in desirable nursing outputs. Thus the head nurse's leadership perceived by her followers is defined as process variable. The output variables were defined as length of stay, average nursing care hours per patient a day the score of quality of nursing care, the score of patient satisfaction, the score of nurse's job satis-faction. The nursing unit was the basis of analysis, and various statistical analyses were used : Reliability analysis(Cronbach's alpha) for 5 measurement tools and Pearson-correlation analysis, multiple regression analysis, and canonical correlation analysis for the test of the relationship among the variables. The results were as follows : 1. Significant positive relationship between the score of patient classification and length of stay was found(r=.6095, p.008). 2. Regression coefficient between the score of patient classification and length of stay was significant (β=.6245, p=.0128), and variance explained was 39%. 3. Significant positive relationship between nurses’ educational period and length of stay was found(r=-.4546, p=.044). 5. Regression coefficient between nurses' educational period and the score of quality of nursing care was significant (β=.5600, p=.029), and variance explained was 31.4%. 6. Significant positive relationship between the score of head nurse's leadership of authoritic characteristics and the length of stay was found (r=.5869, p=.011). 7. Significant negative relationship between the score of head nurse's leadership of benevolent characteristics and average nursing care hours was found(r=-.4578, p=.043). 8. Regression coefficient between the score of head nurse's leadership of benevolent characteristics and average nursing care hours was significant(β=-.6912, p=.0043), variance explained was 47.8%. 9. Significant positive relationship between the score of the head nurse's leadership of benevolent characteristics and the score of nurses' job satis-faction was found(r=.4499, p=050). 10. A significant canonical correlation was found between the group of the independent variables consisted of the score of the nurses' personality, the score of the head nurse's leadership of authoritic characteristics and the group of the dependent variables consisted of the length of stay, average nursing care hours(Rc²=.4771, p=.041). Through these results, the assumed relationships between input variables, process variable, output variables were partly supported. In addition it is also considered necessary that-further study on the relationships between nurses' personality and nurses' educational period, between nurses' clinical experience including skill level and output variables in many research samples should be made.

  • PDF

Delineation of a fault zone beneath a riverbed by an electrical resistivity survey using a floating streamer cable (스트리머 전기비저항 탐사에 의한 하저 단층 탐지)

  • Kwon Hyoung-Seok;Kim Jung-Ho;Ahn Hee-Yoon;Yoon Jin-Sung;Kim Ki-Seog;Jung Chi-Kwang;Lee Seung-Bok;Uchida Toshihiro
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.50-58
    • /
    • 2005
  • Recently, the imaging of geological structures beneath water-covered areas has been in great demand because of numerous tunnel and bridge construction projects on river or lake sites. An electrical resistivity survey can be effective in such a situation because it provides a subsurface image of faults or weak zones beneath the water layer. Even though conventional resistivity surveys in water-covered areas, in which electrodes are installed on the water bottom, do give high-resolution subsurface images, much time and effort is required to install electrodes. Therefore, an easier and more convenient method is sought to find the strike direction of the main zones of weakness, especially for reconnaissance surveys. In this paper, we investigate the applicability of the streamer resistivity survey method, which uses electrodes in a streamer cable towed by ship or boat, for delineating a fault zone. We do this through numerical experiments with models of water-covered areas. We demonstrate that the fault zone can be imaged, not only by installing electrodes on the water bottom, but also by using floating electrodes, when the depth of water is less than twice the electrode spacing. In addition, we compare the signal-to-noise ratio and resolving power of four kinds of electrode arrays that can be adapted to the streamer resistivity method. Following this numerical study, we carried out both conventional and streamer resistivity surveys for the planned tunnel construction site located at the Han River in Seoul, Korea. To obtain high-resolution resistivity images we used the conventional method, and installed electrodes on the water bottom along the planned route of the tunnel beneath the river. Applying a two-dimensional inversion scheme to the measured data, we found three distinctive low-resistivity anomalies, which we interpreted as associated with fault zones. To determine the strike direction of these three fault zones, we used the quick and convenient streamer resistivity.