• Title/Summary/Keyword: Shift Rotation

Search Result 164, Processing Time 0.033 seconds

Multi-dimentional Correction of the Scarf Osteotomy for the Treatment of Hallux Valgus (무지 외반증에 시행한 Scarf 절골술의 3차원적 변형 교정력에 관한 연구)

  • Moon, Gi-Hyuk;Ahn, Gil-Yeong;Yun, Ho-Hyun;Lee, Yeong-Hyun;Lee, Jung-Ick;Nam, Il-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.23-27
    • /
    • 2007
  • Purpose: Scarf osteotomy can provide the simultaneous correction of the hallux valgus angle (HVA), 1-2 intermetatarsal angle ($IMA_{1-2}$), DMAA and the plantar displacement of the fragment. The study was conducted to understand the multi-dimensional correction of the hallux valgus. Materials and Methods: Fourty eight patients who had undergone Scarf osteotomy with hallux valgus at more than $30^{\circ}$ of HVA and more than $15^{\circ}$ of $IMA_{1-2}$ were studied. Before an osteotomy, a reference K-wire was inserted to the 1st metatarsal head. After the osteotomy, the plantar fragment was moved laterally and the proximal end of the fragment was forced beyond the distal end which resulted in an internal rotation of the head fragment to correct the DMAA. Results: The HVA improved an average of $33.3^{\circ}$ to $7.7^{\circ}$ with the IMA1-2 respectively from $15.4^{\circ}$ to $6.5^{\circ}$. The DMAA improved an average of $19.5^{\circ}$ ($5.2-30.9^{\circ}$) to $4.5^{\circ}$ ($0.4-13.8^{\circ}$). By checking the angle, which was at an average of $25^{\circ}$ between the plantar surface of the foot and the osteotomy plane, the average distance of 1.9 mm (1.18-3.1 mm) of plantar displacement was measured using the value of sine (sin 25 = 0.422). Conclusions: It is possible to correct the HVA, IMA1-2 and DMAA simultaneously with one osteotomy making the lateral shift, the internal rotation and the plantar displacement of the plantar head fragment as desired. Despite the technicality and difficulty of the Scarf osteotomy, once familiarized through myriad procedures, all disadvantages are outweighed by the success and satisfaction of both patient and surgeon.

  • PDF

Dentofacial changes of non-orthodontically treated female patients with TMJ disk displacement: a longitudinal cephalometric study (교정 치료를 받지 않은 측두하악관절원반변위가 있는 여성 환자의 두부계측방사선사진을 이용한 안모 및 치열 변화 연구)

  • Han, Jung-Woo;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.398-410
    • /
    • 2010
  • Objective: The purpose of this study was to investigate the changes in dentofacial morphology of non-orthodontically treated female patients with TMJ disk displacement. Methods: The sample consisted of 25 Korean female patients with bilateral TMJ disk displacement who visited the Department of Orthodontics, Seoul National University Dental Hospital from 1996 to 2006. Disk displacements were diagnosed using the magnetic resonance imaging (MRI) of both TMJs. Baseline (T1) and follow-up (T2) lateral cephalograms were analyzed. The mean age of samples at T1 was $18.1{\pm}3.5$ years (range 14.2 - 25.8 years) and at T2, $21.1{\pm}3.5$ years (range 16.2 - 28.0 years). The mean observation period was $3.0{\pm}1.9$ years. Descriptive statistics for each variable were calculated at baseline (T1) and follow-up (T2) stages, and during the observation period (T2-T1). Results: Skeletal changes were found in 64% of the non-orthodontically treated female patients with TMJ disk displacement during the observation period. The L1 to Mandibular plane distance (mm) increased significantly by 0.8 mm (p < 0.01). But there were no significant differences in the other dental relationship variables (overjet, overbite, U1 to palatal plane) during the observation period. Most patients with skeletal changes showed a backward rotation of the mandible. The ratio of the rotation was a decrease of SNB by $0.43^{\circ}$ for every $1^{\circ}$ increase of FMA (Spearman rho = -0.660, P < 0.01). A few patients showed a distal shift of the mandible without rotation or significant changes in the vertical dimension. Conclusions: During observation periods without orthodontic treatment, non-growing patients with TMJ disk displacement showed dentoskeletal changes, mainly backward rotation of the mandible.

ANTERIOR CROSSBITE CORRECTION IN PRIMARY DENTITION USING INTRAORAL APPLIANCE AND CLASS III ELASTIC (구강 내 장치와 III급 고무줄을 이용한 유치열기 전치부 반대 교합 치료)

  • Choi, A-Mi;Choi, Byung-Jai;Choi, Hyung-Jun;Song, Je-Seon;Kim, Seong-Oh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.306-313
    • /
    • 2012
  • Class III malocclusion or anterior crossbite is commonly seen in Asian. This problem is easily recognized by dentists and parents. During the primary dentition period, anterior crossbite with functional shift and deep overbite could develop to skeletal protrusive mandible. So, early and proper diagnosis of anterior crossbite which needs prompt treatment is important. These cases showed the early management of crossbite with functional shift in primary dentition using intraoral removable appliance resulting in improvement of intermaxillary relationship. And I analyzed the positional change and the dimensional change during treatment with lateral cephalometric x-ray analysis. Our patients showed vertical dimensional change of lower anterior facial height and clockwise rotation which results crossbite correction in 1 year of treatment period.

Arthroscopic Posterior Capsular Shaft for Traumatic Recurrent Unidirectional Posterior Subluxation of the Shoulder (외상으로 인한 재발성 단방향 견관절 후방 아탈구의 관절경을 이용한 후방낭 이동술)

  • Kim, Seung-Ho;Ha, Kwon-Ick;Yoo, Jae-Chul;Lee, Yong-Seuk;Lee, Hui-Dong
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.55-66
    • /
    • 2003
  • Background: The purpose of this study was to evaluated results of arthroscopic treatment of the traumatic recurrent unidirectional posterior subluxation. Materials and Methods: We treated twenty-seven patients who had traumatic recurrent unidirectional posterior subluxation of the shoulder by arthroscopic labral repair and posterior capsular shift and prospectively evaluated for a mean of thirty-nine months (range,24 to 85 months). Patients who had posteroinferior instability, multidirectional instability, atraumatic onset, or revision cases were excluded. There were twenty-five male and two female patients with the mean age of twenty-one years (range, 14 to 33 years). All patients were involved in sports activity. All had a significant traumatic event prior to the onset of the instability. Stability, motion, three objective measurement (UCLA, ASES, and Rowe scores) and two subjective measurements (pain and function visual analogue scale) were evaluated. Results: The most common finding in magnetic resonance image-arthrogram was separation of the posteroinferior labrum without displacement in 9 patients, In arthroscopic examination, all patients had one or more lesions in the posterior inferior labrum and capsule. The most common finding was incomplete stripping of the posterior inferior labrum (18 patients). The posteroinferior capsule subjectively appeared to be stretched in twenty-two patients. At follow-up, all patients had improved shoulder function and scores(p < 0.01). All patients had stable shoulder by subjectivel and objectivel measurements, except one patient who had recurrent subluxation. All but one patient with postoperative recurrence were able to return to their prior sports activity with little or no limitation. Twenty-four patients were graded as having more than 90% of shoulder function. Their were twenty-one excellent, five good, and one fair UCLA. scores. Pain sore improved from 4.5 to 0.2 point(p : 0.0001). Mean loss internal rotation was one vertebral level. None had operative complications. Conclusion: In conclusion, treatment outcomes of the traumatic unidirectional recurrent posterior subluxation are consistently reliable with respect to the stability, pain relief, and functional restoration by the arthroscopic posterior capsular shift procedure.

Embedded Fingerprint Verification Algorithm Using Various Local Information (인근 특징 정보를 이용한 임베디드용 지문인식 알고리즘)

  • Park Tea geun;Jung Sun kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4C
    • /
    • pp.215-222
    • /
    • 2005
  • In this paper, we propose a fingerprint verification algorithm for the embedded system based on the minutia extracted using the image quality, the minutia structure, and the Sequency and the orientation of ridges. After the pre- and the post-processing, the true minutia are selected, thus it shows high reliability in the fingerprint verification. In matching process, we consider the errors caused by shift, rotation, and pressure when acquiring the fingerprint image and reduce the matching time by applying a local matching instead of a full matching to select the reference pair. The proposed algorithm has been designed and verified in Arm920T environment and various techniques for the realtime process have been applied. Time taken from the fingerprint registration through out the matching is 0.541 second that is relevant for the realtime applications. The FRR (False Reject Rate) and FAR (False Accept Rate) show 0.079 and 0.00005 respectively.

Several systems for 1Giga bit Modem

  • Park, Jin-Sung;Kang, Seong-Ho;Eom, Ki-Whan;Sosuke, Onodera;Yoichi, Sato
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1749-1753
    • /
    • 2003
  • We proposed several systems for 1Giga bit Modem. The first, Binary ASK(Amplitude Shift Keying) system has a high speed shutter transmitter and no IF(Intermediate Frequency) receiver only by symbol synchronization. The advantage of proposed system is that circuitry is very simple without IF process. The disadvantage of proposed system are that line spectrum occurs interference to other channels, and enhancement to 4-level system is impossible due to its large SNR degradation. The second, Binary phase modulation system has a high speed shutter transmitter and IF-VCO(IF-Voltage Controlled Oscillator) control by base-band phase rotation. Polarity of shutter window is changed by the binary data. The window should be narrow same as above ASK. The advantage of proposed system is which error rate performance is superior. The disadvantage of proposed system are that Circuitry is more complex, narrow pull-in range of receiver caused by VCO and spectrum divergence by the non-linear amplifier. The third, 4-QAM(Quadrature Amplitude Modulation)system has a nyquist pulse transmitter and IF-VCO control by symbol clock. The advantage of proposed system are that signal frequency band is a half of 1GHz, reliable pull-in of VCO and possibility of double speed transmission(2Gbps) by keeping 1GHz frequency-band. The disadvantage of proposed system are that circuit complexity of pulse shaping and spectrum divergence by the non-linear amplifier.

  • PDF

The Dose Distribution of Arc therapy for High Energy Electron (고에너지 전자선 진자조사에 의한 선량분포)

  • Chu, S.S.;Kim, G.E.;Suh, C.O.;Park, C.Y.
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 1983
  • The treatment of tumors along curved surfaces with stationary electron beams using cone collimation may lead to non-uniform dose distributions due to a varying air gap between the cone surface and patient. For large tumors, more than one port may have to be used in irradiation of the chest wall, often leading to regions of high or low dose at the junction of the adjacent ports. Electron-beam arc therapy may elimination many of these fixed port problems. When treating breast tumors with electrons, the energy of the internal mammary port is usually higher than that of the chest wall port. Bolus is used to increase the skin dose or limit the range of the electrons. We invertiaged the effect of various arc beam parameters in the isodose distributions, and combined into a single arc port for adjacent fixed ports of different electron beam eneries. The higher fixed port energy would be used as the arc beam energy while the beam penetration in the lower energy region would be controlled by a proper thickness of bolus. We obtained the results of following: 1. It is more uniform dose distribution of electron to use rotation than stationary irradiation. 2. Increasing isocenter depth on arc irradiation, increased depth of maximum dose, reduction in surface dose and an increasing penetration of the linear portion of the curve. 3. The deeper penetration of the depth dose curve and higher X-ray background for the smaller field sized. 4. If the isocenter depth increase, the field effect is small. 5. The decreasing arc beam penetration with decreasing isocenter depth and the isocenter depth effect appears at a greater depth as the energy increases. 6. The addition of bolus produces a shift in the penetration that is the same for all depths leaving the shape of the curves unchanged. 7. Lead strips 5 mm thick were placed at both ends of the arc to produce a rapid dose drop-off.

  • PDF

The Effect of Tai Chi Training on the Center of Pressure Trajectory While Crossing an Obstacle in Healthy Elderly Subjects

  • Kim, Hyeong-Dong
    • Physical Therapy Korea
    • /
    • v.15 no.4
    • /
    • pp.27-33
    • /
    • 2008
  • The purpose of this study was to investigate the changes of the center of pressure (COP) trajectory in healthy elderly subjects while crossing an obstacle before and after participation in Tai Chi training. Forty healthy elderly subjects participated either in a 12-week intervention of Tai Chi training or in a health education program. The participants were divided into two groups (the experimental group and the control group). Subsequently, the participants were pre- and post-tested on crossing over an obstacle from a quiet stance. Participants in the experimental group received Tai Chi training that emphasized the smooth integration of trunk rotation, a shift in weight bearing from bilateral to unilateral support and coordination and a gradual narrowing of the lower-extremity stance three times weekly. The participants in the control group attended a health education program one hour weekly and heard lectures about general information to promote health. Performance was assessed by recording the changes in the displacement of the COP in the anteroposterior (A-P) and mediolateral (M-L) directions using a force platform. Participants in the Tai Chi group significantly increased the A-P and M-L displacement of the COP after Tai Chi training (p<.05). No significant differences in the A-P and the M-L displacement of the COP between pre-testing and post-testing in the control group were found. This study has shown that participation in Tai Chi exercise increased the magnitude of the A-P and M-L displacement of the COP, thereby improving the ability of healthy elderly participation to generate momentum to initiate gait. These findings support the use of Tai Chi training as an effective fall-prevention program for the elderly.

  • PDF

Postpneumonectomy Syndrome after Left Pneumonectomy -one case report- (좌측 전폐절제술후 발생한 Postpneumonectomy Syndrome의 치험 1례)

  • 윤용한;이두연;김부연
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.624-628
    • /
    • 1998
  • Postpneumonectomy syndrome is a rare and delayed complication of left pneumonectomy in most patients with normal mediastinal vascular anatomy. This syndrome is characterized by dyspnea and recurrent pulmonary infection in the remaining right lung that typically occur within the first postoperative year. The condition is believed to be secondary to postsurgical changes that include a marked shift of the mediastinum to the left, clockwise rotation of the heart and great vessels, and herniation of the right lung into the left anterior thorax. These changes lead to compression of the trachea or right main bronchus among the thoracic spine and the right pulmonary artery. We report a case of postpneumonectomy syndrome in 15 year-old girl that followed by left pneumonectomy for bronchiectasis 6 years ago. We have inserted an expandable prosthesis in the left thoracic cavity posterior to the heart. After implantation of an expandable prosthesis, an anatomic reposition of the shifted mediastinum was achieved, which resulted in instantaneous and sustained relief. The post-operative course was uneventful and the patient was followed in OPD from after discharge to now.

  • PDF

Kinetic Analysis of Golf Fat Shot (골프 Fat shot에 대한 운동역학적 분석)

  • Sohn, Jee-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.523-532
    • /
    • 2013
  • When the golf club hits the ground prior to making contact with the golf ball, we define it as 'fat shot'. The aim of this research was to investigate the difference between normal shot and fat shot in golf. Five candidates playing as recreational golfer participated in this research and they were all right-handed people. Time phase between each event, wrist cocking angle, elbow extension-flexion angle, backswing height, pelvis angle, thorax angle, L-GRF, R-GRF, pelvis linear velocity, pelvis angular velocity and COG path were calculated. For statistical analysis the paired T-test was used. An early un-cocking, an early right elbow extension and impact with leaving their weight behind foot were not reasons of fat shot. Backswing height, X-Factor, pelvis angle and thorax rotation angle were not different between normal shot and fat shot. But we could find a pattern of abrupt pelvic movement and weight shift to target direction just before impact in case of fat shot. In addition fat shot showed time-delayed and small value of pelvis linear velocity pattern to upward during downswing phase as against normal shot.