• Title/Summary/Keyword: Shift Control

검색결과 1,095건 처리시간 0.034초

Friction Coefficient, Torque Estimation, Smooth Shift Control Law for an Automatic Power Transmission

  • Jeong, Heon-Sul;Lee, Kyo-Ill
    • Journal of Mechanical Science and Technology
    • /
    • 제14권5호
    • /
    • pp.508-517
    • /
    • 2000
  • For shift quality improvement, torque sensors are currently too expensive to be used on production vehicles. To achieve smooth acceleration shift, the reference trajectory of the clutch slip speed for accomplishing the shift process within a designated shift completion time and its relationship with the clutch actuating torque were suggested by Jeong and Lee (1999). In order to facilitate the proposed algorithm, nonlinear estimators for necessary information such as the axle shaft torque, clutch friction and turbine torque were designed using only speed sensors. Accounting for the modeling error, a control law for this indirect smooth shift was proposed based on the above mentioned suggestions. Simulation results of the proposed estimators and shift controller were presented and further considerations for practical applications are discussed.

  • PDF

전후진 파워시프트 변속기 유압 제어 시스템 해석 (Analysis of Hydraulic Control System for Shuttle Power-shift Transmission)

  • 김대철
    • 유공압시스템학회논문집
    • /
    • 제6권4호
    • /
    • pp.16-23
    • /
    • 2009
  • The major system of an agricultural shuttle power-shift tractor is the transmission, using power-shift. Because the shifting performance depends on the hydraulic control system, the most important aspect of the optimization is the design of the hydraulic control system. This study was conducted to develop the simulation model of hydraulic control system for the shuttle power-shift transmission by using Easy5 software. Bench test was conducted to verify the simulation. Also, the design parameters which influence the pressure modulation characteristics were investigated.

  • PDF

A Speed Control for the Reduction of the Shift Shocks in Electric Vehicles with a Two-Speed AMT

  • Kim, Young-Ki;Kim, Hag-Wone;Lee, In-Seok;Park, Sung-Min;Mok, Hyung-Soo
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1355-1366
    • /
    • 2016
  • In the present paper, a speed control algorithm with fast response characteristics is proposed to reduce the shift shock of medium/large-sized electric vehicles equipped with a two-speed AMT. Shift shocks, which are closely related with to the vehicles' ride comfort, occur due to the difference between the speed of the motor shaft and the load shaft when the gear is engaged. The proposed speed control method for shift shock reduction can quickly synchronize speeds occurring due to differences in the gear ratios during speed shifts in AMT systems by speed command feed-forward compensation and a state feedback controller. As a result, efficient shift results without any shift shock can be obtained. The proposed speed control method was applied to a 9 m- long medium- sized electric bus to demonstrate the validity through a simulated analysis and experiments.

P-라인을 이용한 압력제어방식 CVT 변속비제어밸브 설계 (Design of Ratio Control Valve for a Pressure Control Type CVT Using P-Line)

  • 류완식;이용준;김현수
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.145-151
    • /
    • 2004
  • In this paper, a pressure control type ratio control valve(RCV) is designed for a metal belt CVT. Steady state and transient characteristics of the pressure control CVT are investigated by simulations and experiments. In addition, P-line is proposed to predict the shift performance. It is found that the bigger the pressure margin, the faster the shift response. It is expected that the P-line can be used in design of the RCV to meet the desired shift performance.

개선된 극점이동 적응제어 알고리즘을 이용한 전력계통 안정화장치의 다기계통 적용 (Application to a Multimachine Power System of Power System Stabilizer using Revised Pole Shift Adaptive Control Algorithm)

  • 이상근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.486-493
    • /
    • 2000
  • This paper presents an application to a multimachine power system of power system stabilizer using revised pole shift adaptive algorithm. Controller parameters are determined by using adaptive control theory in order to maintain optimal operation of generator under the various operating conditions. To determine the optimal parameters of controller and overcome the problem of pole placement algorithm, this paper presents pole shift algorithm revised pole shift factor. Also, the difference between the speed deviation with weighted factor and voltage deviation is used as the input signal of adaptive controller, which provides good damping characteristics. The results tested on a multimachine power system verify that the proposed controller has better dynamic and transient performance than conventional controller.

  • PDF

CVT 변속속도 개선에 의한 엔진최적운전 (Optimal Engine Operation by Shift Speed Improvement for a CVT)

  • 이희라;김현수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.546-551
    • /
    • 2001
  • In this paper, an algorithm to improve the optimal engine operation is suggested by increasing the CVT shift speed. By rearranging the CVT shift dynamic equation, it is found that the CVT shift speed depends on the line pressure as well as the primary pressure. Based on the shift dynamics, an algorithm to accomplish a faster shift speed is presented by increasing the line pressure. In order to apply the algorithm, dynamic models of the line pressure control valve and the ratio control valve are obtained by considering the CVT shift dynamics and model based controllers are designed. It is found from the simulation results that fuel economy can be improved by 2% in spite of the increased hydraulic loss due to the increased line pressure.

  • PDF

빠른 교대근무가 요중 $Na^+,K^+,Cl^-$의 배설에 미치는 영향 (Effect of Rapid Rotating Shift Work on the Urinary $Na^+,K^+,Cl^-$)

  • 민순;문대수;임욱빈
    • 대한간호학회지
    • /
    • 제28권4호
    • /
    • pp.869-880
    • /
    • 1998
  • In order to investigate of the effects of rapid rotating shift work on physiological stress, the activities of urinary Na$^{+}$, $K^{+}$, Cl$^{[-10]}$ were measured in 14 rotational shift nurses, during day shifts(8AM-4PM, n=4), evening shifts(4PM-l2MN, n=5), and night shifts(12MN-8AM, n=5) in hospital twenty students attending nursing college a used as a control group. Urine specimens were collected in 30 minutes before and after work on the second day of shift work. In day shift nurses, Na$^{+}$ activity was 137mM at 8AM and increased to 206mM at 4PM, whereas $K^{+}$ activity was 42mM at 8AM and no significant change at 4PM. Cl$^{[-10]}$ activity was changed from 234mM to 344mM at 4PM at 8AM. In the evening shift, Na$^{+}$ activity was 117mM at 4PM and 140mM at 12MN, $K^{+}$ activity was 22mM and 32mM, respectively. Cl$^{[-10]}$ activity was 169mM and changed to 270mM. During the night shift, Na$^{+}$ activity was 128mM at 12MN and changed to 161mM at 8AM, $K^{+}$ activity was 42mM at 12MN and 8AM, and Cl$^{[-10]}$ activity was from 303mM and changed to 355mM. In general, the urinary ion activities seemed to increase after work, however there were no significant changes in ion activities except the Na$^{+}$ increase in day shift. The mean of the activities of $K^{+}$ and Cl$^{[-10]}$ before and after work during the day and night shift were significantly higher than those in control group (P<0.05). $K^{+}$ activities were also higher than that of evening shift(P<0.05). However, there was no difference in Na$^{+}$ activity among the control group and three shifts. There was a significant relationship among urinary Na$^{+}$, Cl$^{[-10]}$ and $K^{+}$ in the control group and rotating shift nurses except between Na$^{+}$ and $K^{+}$ in shift. The relationship between Na$^{+}$ and Cl$^{[-10]}$ was low in shift work and there was no significant relationship between Na$^{+}$ and $K^{+}$ in shift, suggesting that the active regulation $K^{+}$ and/or Na$^{+}$ in response to stress upon the shift work disruped the ratio of urinary Na$^{+}$ to $K^{+}$ and also lowered the relationship between $K^{+}$ and Cl$^{[-10]}$ . These results suggest that nurses working the day shift were overloaded and under stress, and the night shift interfered with the physiological rhythm of the nurses.red with the physiological rhythm of the nurses.

  • PDF

Establishment of a Tm-shift Method for Detection of Cat-Derived Hookworms

  • Fu, Yeqi;Liu, Yunqiu;Abuzeid, Asmaa M.I.;Huang, Yue;Zhou, Xue;He, Long;Zhao, Qi;Li, Xiu;Liu, Jumei;Ran, Rongkun;Li, Guoqing
    • Parasites, Hosts and Diseases
    • /
    • 제57권1호
    • /
    • pp.9-15
    • /
    • 2019
  • Melting temperature shift ($T_m-shift$) is a new detection method that analyze the melting curve on real-time PCR thermocycler using SYBR Green I fluorescent dye. To establish a $T_m-shift$ method for the detection of Ancylostoma ceylanicum and A. tubaeforme in cats, specific primers, with GC tail of unequal length attached to their 5' end, were designed based on 2 SNP loci (ITS101 and ITS296) of the internal transcribed spacer 1 (ITS1) sequences. The standard curve of $T_m-shift$ was established using the standard plasmids of A. ceylanicum (AceP) and A. tubaeforme (AtuP). The $T_m-shift$ method stability, sensitivity, and accuracy were tested with reference to the standard curve, and clinical fecal samples were also examined. The results demonstrated that the 2 sets of primers based on the 2 SNPs could accurately distinguish between A. ceylanicum and A. tubaeforme. The coefficient of variation (CV) of $T_m$- values of AceP and AtuP was 0.07% and 0.06% in ITS101 and was 0.06% and 0.08% in ITS296, respectively. The minimum detectable DNA concentration was $5.22{\times}10^{-6}$ and $5.28{\times}10^{-6}ng/{\mu}l$ samples of AceP and AtuP, respectively. The accuracy of $T_m-shift$ method reached 100% based on examination of 10 hookworm DNA samples with known species. In the clinical detection of hookworm in 69 stray cat fecal sample, the $T_m-shift$ detection results were consistent with the microscopic examination and successfully differentiated between the 2-hookworm species. In conclusion, the developed method is a rapid, sensitive and accurate technique and can provide a promising tool for clinical detection and epidemiological investigation of cat-derived hookworms.

자동변속기장착 차량의 Shift-By-Wire 시스템 개발 (Development of Shift-By-Wire System for an Automatic Transmission Equipped Vehicle)

  • 김정윤;임충혁;임원식
    • 한국자동차공학회논문집
    • /
    • 제15권4호
    • /
    • pp.41-46
    • /
    • 2007
  • This article deals with the design and prototyping of Shift-By-Wire system for an automatic transmission equipped vehicle. In order to manipulate the shifting action electronically, Shift-By-Wire system consists of an electronic shift lever, an electric shift actuator and position sensors. The shift lever is designed to transform the driver's shifting command into an electric signal; it includes the position sensor using non-contact type hall sensor and an additional shifting switch acting as Tip-tronic. For the design of an electric shifting actuator, we investigated the stroke angles and shifting efforts of the manual control lever in each shifting section. And the position sensor of the shifting actuator is designed by using a potentiometer with an optical encoder. Finally the prototype of Shift-By-Wire system was built in a conventional 2.4L class SUV vehicle, and we performed road tests in order to verify its performance.

Minimize Reactive Power Losses of Dual Active Bridge Converters using Unified Dual Phase Shift Control

  • Wen, Huiqing;Su, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.654-664
    • /
    • 2017
  • This paper proposed an unified dual-phase-shift (UDPS) control for dual active bridge (DAB) converters in order to improve efficiency for a wide output power range. Different operating modes of UDPS are characterized with respect to the reactive current distribution. The proposed UDPS has the same output power capability with conventional phase-shift (CPS) method. Furthermore, its implementation is simple since only the change of the leading phase-shift direction is required for different operating power range. The proposed UDPS control can minimize both the inductor rms current and the circulating reactive current for various voltage conversion ratios and load conditions. The optimal phase-shift pairs for two bridges of DAB converter are derived with respect to the comprehensive reactive power loss model, including the reactive components delivered from the load and back to the source. Simulation and experimental results are illustrated and explained with details. The effectiveness of the proposed method is verified in terms of reactive power losses minimization and efficiency improvement.