• Title/Summary/Keyword: Shift Characteristics

Search Result 1,300, Processing Time 0.038 seconds

A Study on the Characteristics of Lower Extremity Muscle Activation according to the Variable Weight Shift on the Affected Side in Hemiplegic Patients (편마비 환자의 마비측으로의 다양한 중심이동에 따른 하지 근육 활성도 특성에 관한 연구)

  • Kim, Kyung-Hwan;Park, Sung-Hun;Pak, Noh-Wook;Lee, Hye-Jin
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.93-101
    • /
    • 2019
  • Purpose: This study aimed to investigate lower extremity muscle activation to the variable weight shift on the affected side of patients with hemiplegia. Methods: Eighteen patients with chronic hemiplegia volunteered to participate in this study. All participants performed three types of weight shift (sideways, forward, and backward) in limits of stability on the affected side. Muscle activation in a paralyzed leg was measured with electromyography on the gluteus medius, tensor fasciae latae, rectus femoris, and biceps femoris; furthermore, the attached area was recommended by SENIAM projects. Each weight shift was performed three times, and then the mean value of the three measurements was analyzed. The data were analyzed by measuring the symmetrically standing position with the reference voluntary contraction (RVC) and was standardized with the percentage of RVC method. Results: No significant difference in lower extremity muscle activation occurred according to the three types of variable weight shift. However, significant differences in lower extremity muscle activation did occur with each weight shift position. In addition, activation increased at the rectus femoris and decreased at the gluteus medius and tensor fasciae latae. Conclusion: Hip abductor muscle strength training and variable weight shifts on the affected side must increase to improve patients'balance and limits of stability.

Night shift preparation, performance, and perception: are there differences between emergency medicine nurses, residents, and faculty?

  • Richards, John R.;Stayton, Taylor L.;Wells, Jason A.;Parikh, Aman K.;Laurin, Erik G.
    • Clinical and Experimental Emergency Medicine
    • /
    • v.5 no.4
    • /
    • pp.240-248
    • /
    • 2018
  • Objective Determine differences between faculty, residents, and nurses regarding night shift preparation, performance, recovery, and perception of emotional and physical health effects. Methods Survey study performed at an urban university medical center emergency department with an accredited residency program in emergency medicine. Results Forty-seven faculty, 37 residents, and 90 nurses completed the survey. There was no difference in use of physical sleep aids between groups, except nurses utilized blackout curtains more (69%) than residents (60%) and faculty (45%). Bedroom temperature preference was similar. The routine use of pharmacologic sleep aids differed: nurses and residents (both 38%) compared to faculty (13%). Residents routinely used melatonin more (79%) than did faculty (33%) and nurses (38%). Faculty preferred not to eat (45%), whereas residents (24%) preferred a full meal. The majority (>72%) in all groups drank coffee before their night shift and reported feeling tired despite their routine, with 4:00 a.m. as median nadir. Faculty reported a higher rate (41%) of falling asleep while driving compared to residents (14%) and nurses (32%), but the accident rate (3% to 6%) did not differ significantly. All had similar opinions regarding night shift-associated health effects. However, faculty reported lower level of satisfaction working night shifts, whereas nurses agreed less than the other groups regarding increased risk of drug and alcohol dependence. Conclusion Faculty, residents, and nurses shared many characteristics. Faculty tended to not use pharmacologic sleep aids, not eat before their shift, fall asleep at a higher rate while driving home, and enjoy night shift work less.

Effects of Permalloy Multilayered Schemes and CoZrNb Intermediate Layer on Recording Characteristics of CoCr/NiFe Media (Permalloy 다층화와 CoZrNb 중간층이 CoCr/NiFe 매체의 기록특성에 미치는 영향)

  • 장평우;이택동;박관수
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.1
    • /
    • pp.20-24
    • /
    • 1994
  • The read/write characteristics of CoCr/NiFe double layered media are strongly affected by the magnetic properties of NiFe magnetic soft layer as well as those of CoCr recording layer. Modification of the permalloy layer by NiFe/Ge multilayer scheme resulted in the higher recording sensitivity and the higher reproduced voltage of CoCr/NiFe medium and this is attributed to the higher permeability of the back layer and high perpendicular anisotropy of the CoCr recording layer. Although higher permeability of back layer results in higher recording sensitivity, the increment of the reproduced voltage was not remarkable, which can be confirmed in the FEM numerical analysis. On the contrary, peak shift characteristics of the CoCr/NiFe medium with the NiFe multi back layer was deteriorated compared to that of the CoCr/NiFe medium with NiFe single back layer. Insertion of ferromagnetic thin CoZrNb intermediate layer between CoCr and NiFe layer was effective to ensure large reproduced voltage and low peak shift. These recoridng characteristics were also discussed in connection with microstructural characteristics.

  • PDF

Influence of the hydrogen post-annealing on the electrical properties of metal/alumina/silicon-nitride/silicon-oxide/silicon capacitors for flash memories

  • Kim, Hee-Dong;An, Ho-Myoung;Seo, Yu-Jeong;Zhang, Yong-Jie;Kim, Tae-Geun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.122-122
    • /
    • 2008
  • Recently, Metal/Alumina/Silicon-Nitride/Silicon-Oxide/Silicon (MANOS) structures are one of the most attractive candidates to realize vertical scaling of high-density NAND flash memory [1]. However, as ANO layers are miniaturized, negative and positive bias temperature instability (NBTI/PBTI), such as the flat band voltage shift, ${\Delta}V_{FB}$, the interfacial trap density increase, ${\Delta}D_{it}$, the gate leakage current, ${\Delta}I_G$. and the retention characteristics, in MONOS capacitors, becomes an important issue in terms of reliability. It is well known that tunnel oxide degradation is a result of the oxide and interfacial traps generation during FN (Fowler-Nordheim) stress [2]. Because the bias temperature stress causes an increase of both interfacial-traps and fixed oxide charge could be a factor, witch can degrade device reliability during the program and erase operation. However, few studies on NBTI/PBTI have been conducted on improving the reliability of MONOS devices. In this work, we investigate the effect of post-annealing gas on bias temperature instability (BTI), such as the flat band voltage shift, ${\Delta}V_{FB}$, the interfacial trap density shift, ${\Delta}I_G$ retention characteristics, and the gate leakage current characteristics of MANOS capacitors. MANOS samples annealed at $950^{\circ}C$ for 30 s by a rapid thermal process were treated via additional annealing in a furnace, using annealing gases $N_2$ and $N_2-H_2$ (2 % hydrogen and 98 % nitrogen mixture gases) at $450^{\circ}C$ for 30 min. MANOS samples annealed in $N_2-H_2$ ambient had the lowest flat band voltage shift, ${\Delta}V_{FB}$ = 1.09/0.63 V at the program/erase state, and the good retention characteristics, 123/84 mV/decade at the program/erase state more than the sample annealed at $N_2$ ambient.

  • PDF

Association between shift work and serum homocysteine level in female electronic manufacturing services workers

  • Jae Won Lim;Chan Woo Kim;Hyoung Ouk Park;Eui Yup Chung;Changho Chae;JunSeok Son;Young Hoo Shin;Seung Hyun Park;Sang Moon Choi
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.4.1-4.11
    • /
    • 2023
  • Background: Shift work has been shown to increase the risk of cardiovascular disease (CVD) based on several evidences. The classic risk factors of CVD include age, hypertension, smoking, obesity and diabetes. Recently, the serum homocysteine level has been reported to be a valuable indicator of CVD risk. This study aimed to determine the variation in serum homocysteine level as a cardiovascular risk indicator among female workers according to shift work. Methods: The data of regular health examination of workers at an electronic manufacturing services company in Yeongnam region, South Korea in 2019 were examined in this study. The investigation was based on a cross-sectional study conducted on 697 female workers (199 day workers and 498 shift workers). The sociodemographic and biochemical characteristics were compared between day workers and shift workers. Through a logistic regression analysis, the odds ratio (OR) of the increased serum homocysteine level in relation to shift work was determined. Results: Compared to female day workers, female shift workers showed significantly higher level of serum homocysteine (8.85 ± 2.16 vs. 9.42 ± 2.04 μmol/mL; p = 0.001). The OR of day workers against shift workers was 1.81 (95% confidence interval [CI]: 1.25-2.63). With the adjustment of variables that may influence the level of serum homocysteine, the adjusted OR was 1.68 (95% CI: 1.09-2.60). Conclusions: The serum homocysteine level was significantly higher in shift workers than in day workers. It is thus likely to be a useful predictor of CVD in shift workers.

An optical object recognition system using log-polar coordinate transform of power spectrum and NJTC (파워스펙트럼의 Log-polar 좌표변환 및 NJTC를 이용한 광 물체 인식 시스템)

  • 이상이;채호병;이승현;김은수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.178-188
    • /
    • 1996
  • In this paper, we propose a new opto-digital object recognition system which has rotation, scale, and shift invariant characteristics. The fourier power spectrum of the object image is modified to get shift invariance. The log-polar transform is used for rotation and scale invariance. And the decision of similarities is performed by nonlinear joint transform correlator (NJTC) that can control the ratio of phase and amplitude signals. Experimental verification of th eproposed optical object recognition system is presented.

  • PDF

Bond Graph Modeling and Control for an Automatic Transmission (자동변속기의 본드선도 모델링 및 제어)

  • 강민수;강조웅;김종식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.425-430
    • /
    • 2002
  • An automatic transmission model using the bond graph techniques is developed for analyzing shift characteristics of vehicles. Bond graph models can be systemically manipulated to yield state space equations of standard form. Bond graph techniques are applied for modeling overall automatic transmission systems and shift models. A fuzzy controller is synthesized for the verification of a shifting model in the ${1^st} gear to the {2^nd}$ gear. Simulation results show the fitness of models by the bond graph techniques.

  • PDF

Modulation and demodulation circuits of chaos frequency shift keying using coupled synchronization and drive synchronization (결합동기와 구동동기를 이용한 카오스 주파수 천이 변.복조 회로)

  • 정종은;박진수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.7
    • /
    • pp.86-98
    • /
    • 1996
  • Modulation and demodualtion circuits of chaos frequency shift keying have been implemented using chua's circuits. The modulatin circuit, which is designed ot perform the frequency-doubling by coupled synchronization wihtout changing the intrinsic characteristics of its two chaos signals generated, modulates the digital input signals. The demodulation circuit detects the digital input signals form carrier by drive synchronization. these circuits, which are simplest until now and have no restriction to their digital input amplitudes, perform the aimed functions.

  • PDF

Design of Linear Synchronous Motor for Thrust Force Ripple Reduction using Module Phase Set Shift (Module Phase Set Shift를 이용한 선형 동기 전동기의 추력 리플 저감 설계)

  • Ryu, Gwang-Hyeon;Lee, Hyung-Woo;Cho, Su-Yeon;Oh, Se-Young;Ham, Sang-Hwan;Im, Jong-Bin;Ahn, Han-Woong;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.848-849
    • /
    • 2011
  • Rotating machines are using gears to change the rotary motion into the linear motion, on the other hand, linear motors have a accurate position control and excellent dynamic characteristics because of generating a thrust force directly. But the important problem, one of the linear motor is a high thrust force ripple. Thrust force ripple has a bad effect on the position accuracy and the dynamic characteristics, so it is necessary to reduce the thrust force ripple. Cogging is one of the cause that affect thrust force ripple. Cogging has some connection with the GCD between pole pitch and teeth pitch It is proposed method to reduce a thrust ripple of the linear motor that chamfering, skew, and so on. In this paper, the module phase set shift(MPSS) is used to reduce a thrust force ripple that has a similar effect to skew. And propose a method that reduce a thrust force ripple more by use of chamfering.

  • PDF

Influence of in-situ remote plasma treatment on characteristics of amorphous indium gallium zinc oxide thin film-based transistors

  • Gang, Tae-Seong;Gu, Ja-Hyeon;Hong, Jin-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.257-257
    • /
    • 2011
  • The amorphous indium-gallium-zinc-oxide (a-IGZO) materials for use in high performance display research fields are strongly investigated due to its good performance, such as high mobility and better transparency. However, the stability of a-IGZO materials is increasingly becoming one of critical issues due to the sub-gap electron trap sites induced by rough interfaces during deposition processing. It is well-known that the threshold voltage shift is related to interface roughness and oxygen vacancy formed by breaking weak chemical bonds. Here, we report the better properties of transparent oxide transistors by reducing the threshold voltage shift with an external rf plasma supported magnetron sputtering system. Mainly, our sputtering method causes the surface of sample to be sleek, so that it prevents the formation of various defects, such as shallow electron trap sites in the interface. External rf power was applied from 0 to 50W during RF sputtering process to enhance the stability of our oxide transistor without having a large voltage shift. To observe the effects of external rf-plasma source on the properties of our devices, Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), Transmission Electron Microscopy (TEM) are carried out to observe surface roughness and morphology of sputtered thin film. In addition, typical electrical properties, such as I-V characteristics are analyzed.

  • PDF