• Title/Summary/Keyword: Shielding effect

Search Result 539, Processing Time 0.025 seconds

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

A Comparative Analysis of Negative Air Ions according to the Planting Structure at School Forests (학교 숲 식재구조에 따른 음이온 발생량 비교 분석)

  • Kim, Jeong-Ho;Oh, Deuk-Kyun;Park, Yong-Gwan;Yoon, Yong-Han
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.55-64
    • /
    • 2015
  • In this study, negative air ions, which can increase comfort and positively influence human health, was set as an evaluative factor for school forests. The characteristics, location and microclimate of school forests were examined to determine an effective school forest model for maximum negative air ion generation. It also aimed to provide basic data for the development of urban green fields. The negative air ion concentrations were different according to the green types. The order from the highest to the lowest was: single-layer structure($934ea/cm^3$) > multi-layer structure($794ea/cm^3$) > grass($553ea/cm^3$) > bare ground($529ea/cm^3$). As for the correlation with microclimate, negative air ion concentration was negatively correlated with temperature. The negative air ion concentration was significantly different according to planting type. The negative air ion concentration was higher at single-layer structure sites than at multi-layer structure sites, which appears to indicate that the temperature is higher when the vegetation structure was single-layer compared to multi-layer. Wind speed was higher at the single-layer planted site than at the multi-layer planted site. The vegetation wind shielding effect was lower at single-layer planted sites than at multi-layer planted sites. The single-layer planted site provided more favorable conditions for the generation and dispersion of negative air ions.

A Preliminary Drop Test of a Type IP-2 Transport Package with a Bolted Lid Type (볼트체결방식의 IP-2형 운반용기의 낙하예비시험)

  • Kim Dong-Hak;Seo Ki-seog;Park Hong Yun;Lee Kyung Ho;Yoon Jeong-Hyoun;Lee Heung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.339-347
    • /
    • 2005
  • A type IP-2 transport package should prevent a loss or dispersal of the radioactive contents and a more than $20\%$ increase in the maximum radiation level at any external surface of the package when it were subjected to the drop test under the normal conditions of transport. If a shielding thickness of IP-2 transport package is thick, a bolted lid type may prevent a loss or dispersal of the radioactive contents than the door type of ISO containers which are generally used as a type IP-2 transport package. In this paper, to evaluate the effect of drop directions on the bolt tension and the coherence of a bolt, the drop tests of preliminary small model are tested and evaluated for seven directions before the drop test of a type IP-2 transport package with a bolted lid type under the normal conditions of transport. Seven drop directions which are a bottom-vertical drop, a lid-vortical drop. a horizontal drop and four corner drops have been carried out. Using a force sensor, the bolt tension during the drop impact is measured. The coherence of bolt is evaluated by the difference between the fastening torque of bolt before a drop test and the unfastening torque of bolt after a drop impact.

  • PDF

Study on Analysis Technique Comparison and Evaluation of High Thermal Conductivity Concrete with Magnetite Aggregates and Steel Powder (자철광 및 철분말을 혼입한 고열전도 콘크리트의 열전도 평가 및 해석기법 비교에 대한 연구)

  • Lee, Hack-Soo;Kim, Min-Kyu;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.315-321
    • /
    • 2014
  • Concrete as a construction material is widely used in nuclear vessel and plant for excellent radiation shielding. However the isolation characteristics in concrete may affect adversely in the case of fire and melt-down in nuclear vessel since temperature cooling down is very difficult from outside. This study is for development of high thermal conductive concrete, and its mechanical and thermal properties are evaluated. Magnetite aggregates with volume ratio of 42.3% (maximum) and steel powder of 1.5% are replaced with normal aggregates and thermal properties are evaluated. Thermal conductivity little increases by 30% addition of magnetite but rapidly increases afterwards. Finally thermal conductivity is magnified to 2.5 times in the case of 42.3% addition of magnetite. Steel powder has a positive effect on high thermal conduction to 106~113%. Several models for thermal conduction like ACI, DEMM, and MEM are compared with test results and they are verified to reasonably predict the thermal conductivity with increasing addition of magnetite aggregates and steel powder.

The Relationship between Particular Matter Reduction and Space Shielding Rate in Urban Neighborhood Park (도시근린공원 미세먼지(PM)저감과 공간차폐율과의 관계 - 대구광역시 수성구 근린공원을 중심으로 -)

  • Koo, Min-Ah
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.6
    • /
    • pp.67-77
    • /
    • 2019
  • The purpose of this study is to analyze how much particulate matter at the center of the urban park is reduced compared to the entrance of the park, where the particulate matter problem is serious. It also endeavored to analyze the relationship between the space closure rate and particulate matter reduction rate in the center of the park through the collection and analysis of experimental data. Seven flat land type urban neighborhood parks in Suseong-gu, Daegu were measured at the same place for three days. The research results are as follows. First, the center of the urban neighborhood park had an average temperature 1.05℃ lower than at the entrance and an average humidity of 2.57% higher. Second, the rate of fine dust reduction was PM1- 17.09%, PM2.5- 17.65%, PM10- 14.99%. As for the reduction rate of particulate matter, the smaller the size of the park, the greater the reduction rate. In addition, the reduction rate at the center of the park was lower on days when particulate matter concentration based on the weather reports was low. The higher the concentration at the park entrance, the higher the reduction rate was. Third, a higher the rate of space closures at the center of the park resulted in a higher effect of particulate matter reduction. Noting this, the relationship between particulate matter reduction and the space closure rate in urban neighborhood parks was clearly shown. We hope to be the basis for more extensive experimental data collection.

A Study on the Treatment of Dyeing Wastewater Using TiO2/UV (TiO2/UV 산화기술을 이용한 염색폐수처리에 관한 연구)

  • Kim, Jong-kyu;Chung, Ho-jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.392-400
    • /
    • 2004
  • This research uses the $TiO_2$/UV process to verify the most suitable condition and possibility to dispose dyeing wastewater that contains pigment and a large amount of pollutants. For this, this research has enforced experiments that compare photo adsorption, photolysis, and photo catalyst oxidation reaction, and also evaluated and analyzed the change of pH and $TiO_2$ dosage, irradiation rates of ultraviolet rays and the dosage change and injection method of $H_2O_2$. According to the results of the dyeing wastewater experiment of storehouse catalyst that uses the new form of $TiO_2$, the photo catalyst oxidation reaction proved to be more effective than photo adsorption and photolysis; 35%, 21% in the case of $TCOD_{cr}$ and 39%, 28% in the case of chromaticity. Taking into consideration the reaction time, amount of photo catalyst reaction and irradiation amount of ultraviolet rays, the decomposition efficiency of pH change proved to be most effective at pH 4. On the whole, the acidity area proved to be effective in dyeing water exclusion than neutral and alkalinity areas. Having evaluated the influence of $TiO_2$ dosage, not only does the decomposition efficiency continuously improve as the $TiO_2$ dosage increases but the shielding effect does not occur also when the $TiO_2$ is at a fixed state. The influence of ultraviolet irradiation amount concluded in the result that as the ultraviolet irradiation amount increases the decomposition efficiency continually increased, but in the case of chromaticity when the irradiation amount was higher than 37.8mW/cm2 the removal efficiency is slowed remarkably. The influence of $H_2O_2$ dosage evaluation reached the results that although the decomposition efficiency increases with the increase of $H_2O_2$ dosage, when above 150mg (total dosage: 1200mg) $H_2O_2$ consumes OH radical itself and reduces the decomposition efficiency. Also in the case of the $H_2O_2$ injection method rather than injecting in the whole amount of $H_2O_2$ (1200mg) needed at the beginning all at once, injecting divided quantities of $H_2O_2$ whenever the electric current density falls below 10mgfl reduces the wases of OH radical due to an excess of $H_2O_2$ and in tum heightens the decomposition efficiency.

Between-hemisphere Separation of Target and Distractor Reduces Response Interference (표적과 방해자극의 반구간 분리가 반응 간섭에 미치는 영향)

  • Kim Min-Shik;Sohn Young-Sook
    • Korean Journal of Cognitive Science
    • /
    • v.17 no.1
    • /
    • pp.29-52
    • /
    • 2006
  • There has been a claim that Interaction between the cerebral hemispheres could reduce the effect interfering information (Weissman & Banich, 1999). We ran three experiments to show that between-hemisphere separation of target and distractor could be more effective for reducing interference than Interaction between the hemispheres. In experiment 1, a colored box and a rotor name were presented to a single or to separate hemispheres. In experiment 2 and 3, a colored circle (distractor) was presented along with a colored box and a color name which was always printed in black. In experiment 3, a peripheral cue was presented either to the target location(66.7%) or to the distractor location(33.3%) Immediately before the presentation of stimuli. In all experiments, the participants were asked to deride whether the moaning of the color matched the rotor of the box, Ignoring the printed rotor of the word(Exp. 1), or the color of the circle(Exp. 2 & 3). There were three renditions of distractor (congruent, incongruent, and neutral) and two conditions of matching (between- and within-hemisphere matching). If interhemispheric interaction were effective for interference reduction, there should be a decrease in the interference in the between-hemisphere compared to the within-hemisphere matching condition. The results showed that there was no difference in the interference between the two matching conditions in Exp 1. In Exp 2 and in the target-cue renditions of Exp. 3, the amount of interference in the between-hemisphere condition was greater than that in the within-hemisphere condition. These findings are consistent with what we have previously reported (Sohn et al., 1996, Sohn & Lee, 2003). However, when the distractor was precued in Exp. 3, the amount of interference did not differ between the two marching conditions. These results suggest that between-hemisphere separation of target and distractor can be more effective for reducing response interference than interhemispheric communication. It implies a possible role of an interhemispheric shielding mechanism (Merola & Liederman, 1985) to prevent the transfer of task-irrelevant, harmful information across the hemispheres.

  • PDF

Characteristics and Stability of the Color of the Cranberry Solution (크랜베리 수용액 색상의 특성 및 안정성)

  • 김진현;이재하;백창규
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.6
    • /
    • pp.806-811
    • /
    • 2003
  • Effects of pH, temperature, light, sugars, organic acids, metal ions, ascorbic acid, thiamine nicotinic acid and pyridoxine on the stability of the color of the cranberry solution were investigated. The pH had marked influences on the color of the cranberry solution: i.e., the color of the cranberry solution was more intense at low pH. It showed characteristic bathochromic shift as the pH of the solution increased. The half-lives of olor value were 34 days at 37$^{\circ}C$, 91 mins at 9$0^{\circ}C$ and 29 mins at 12$0^{\circ}C$. Light gave an adverse effect to the stability of the color. The color degradation can be minimized by shielding the light from the cranberry solution. Among the sugars tested, fructose was the most deleterious followed by sucrose, galactose, maltose and glucose. Fumaric acid was found to be the most effective in stabilizing the color followed by citric acid, malic acid, acetic acid, while tartaric acid was found to be deleterious. Among the metal ions tested N $a^{+}$ and $Mg^{2+}$ were found to be effective in stabilizing the color, while M $n^{2+}$ was found to be the most deleterious followed by F $e^{2+}$, $K^{+}$ and $Ca^{2+}$. Ascorbic acid was found to be deleterious considerably followed by thiamine, while nicotinic acid and pyridoxine were found to be effective in stabilizing the color feebly.or feebly.

Development of GPS Multipath Error Reduction Method Based on Image Processing in Urban Area (디지털 영상을 활용한 도심지 내 GPS 다중경로오차 경감 방법 개발)

  • Yoon, Sung Joo;Kim, Tae Jung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.2
    • /
    • pp.105-112
    • /
    • 2018
  • To determine the position of receiver, the GPS (Global Positioning System) uses position information of satellites and pseudo ranges based on signals. These are reflected by surrounding structures and multipath errors occur. This paper proposes a method for multipath error reduction using digital images to enhance the accuracy. The goal of the study is to calculate the shielding environment of receiver using image processing and apply it to GPS positioning. The proposed method, firstly, performs a preprocessing to reduce the effect of noise on images. Next, it uses hough transform to detect the outline of building roofs and determines mask angles and permissible azimuth range. Then, it classifies the satellites according to the condition using the image processing results. Finally, base on point positioning, it computes the receiver position by applying a weight model that assigns different weights to the classified satellites. We confirmed that the RMSE (Root Mean Square Error) was reduced by 2.29m in the horizontal direction and by 15.62m in the vertical direction. This paper showed the potential for the hybrid of GPS positioning and image processing technology.

An Analysis of Global Solar Radiation using the GWNU Solar Radiation Model and Automated Total Cloud Cover Instrument in Gangneung Region (강릉 지역에서 자동 전운량 장비와 GWNU 태양 복사 모델을 이용한 지표면 일사량 분석)

  • Park, Hye-In;Zo, Il-Sung;Kim, Bu-Yo;Jee, Joon-Bum;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.129-140
    • /
    • 2017
  • Global solar radiation was calculated in this research using ground-base measurement data, meteorological satellite data, and GWNU (Gangneung-Wonju National University) solar radiation model. We also analyzed the accuracy of the GWNU model by comparing the observed solar radiation according to the total cloud cover. Our research was based on the global solar radiation of the GWNU radiation site in 2012, observation data such as temperature and pressure, humidity, aerosol, total ozone amount data from the Ozone Monitoring Instrument (OMI) sensor, and Skyview data used for evaluation of cloud mask and total cloud cover. On a clear day when the total cloud cover was 0 tenth, the calculated global solar radiations using the GWNU model had a high correlation coefficient of 0.98 compared with the observed solar radiation, but root mean square error (RMSE) was relatively high, i.e., $36.62Wm^{-2}$. The Skyview equipment was unable to determine the meteorological condition such as thin clouds, mist, and haze. On a cloudy day, regression equations were used for the radiation model to correct the effect of clouds. The correlation coefficient was 0.92, but the RMSE was high, i.e., $99.50Wm^{-2}$. For more accurate analysis, additional analysis of various elements including shielding of the direct radiation component and cloud optical thickness is required. The results of this study can be useful in the area where the global solar radiation is not observed by calculating the global solar radiation per minute or time.