• Title/Summary/Keyword: Shielding Calculation

Search Result 135, Processing Time 0.019 seconds

Assessment of a Pre-conceptual Design of a Spent PWR Fuel Disposal Container (가압경수로형 사용후핵연료 처분용기의 예비 개념설계 평가)

  • Choi, Jong-Won;Cho, Dong-Keun;Lee, Yang;Choi, Heui-Joo;Lee, Jong-Youl
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.41-50
    • /
    • 2006
  • In this paper, sets of engineering analyses were conducted to renew the overall dimensions and configurations of a disposal container proposed as a prototype in the previous study. Such efforts and calculation results can provide new design variables such as the inner basket array type and thickness of the outer shell and the lid & bottom of a spent nuclear fuel disposal container. These efforts include radiation shielding and nuclear criticality analyses to check to see whether the dimensions of the container proposed from the mechanical structural analyses can provide a nuclear safety or not. According to the results of the structural analysis of a PWR disposal container by varying the diameter of the container insert, the Maximum Von Mises stress from the 102 cm-container meets the safety factor of 2.0 for both extreme and normal load conditions. This container also satisfies the nuclear criticality and radiation safety limits. This decrease in the diameter results in a weight loss of a container by $\sim20$ tons.

  • PDF

Pre-conceptual Design of a Spent PWR Fuel Disposal Container (가압경수로형 사용후핵연료 처분용기의 예비 개념설계 평가)

  • CHO Dong-Keun;CHOI Jongwon;Lee Yang;CHOI Heui-Joo;LEE Jong-Youl
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.153-162
    • /
    • 2005
  • In this Paper, sets of engineering analyses were conducted to renew the overall dimensions and configurations of a disposal container proposed as a prototype in the previous study. Such efforts and calculation results can provide new design variables such as the inner basket array type and thickness of the outer shell and the lid & bottom of a spent nuclear fuel disposal container. These efforts include radiation shielding and nuclear criticality analyses to check to see whether the dimensions of the container proposed from the mechanical structural analyses can provide a nuclear safety or not. According to the results of the structural analysis of a PWR disposal container by varying the diameter of the container insert, the Maximum Von Mises stress from the 102 cm container meets the safety factor of 2.0 for both extreme and normal load conditions. This container also satisfies the nuclear criticality and radiation safety limits. This decrease in the diameter results in a weight loss of a container by ${\~}$20 tons.

  • PDF

Evaluation of Neutron Flux Distributions of SMART-P IST Region for the Design of Ex-Core Detector (SMART 연구로 노외계측기 설계를 위한 IST 영역의 중성자속 분포 평가)

  • Koo, Bon-Seung;Kim, Kyo-Youn;Lee, Chung-Chan;Zee, Sung-Quun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2005
  • The evaluation of neutron flux distribution was performed for the ex-core detector design of SMART-P. DORT and MCNP code were used for the calculation of energy-dependent neutron flux distribution at 100% full power condition. Two code results show that maximum thermal flux appears at the $1^{st}$ water region in IST region and agree within 10% difference. In addition, another evaluation was performed code with assumptions that cote was composed of fission source and control rod without fuel assemblies. These assumptions make neutron count rate to be minimized. As a results, maximum thermal flux showed $6.99{\times}10^{-2}(n/cm^2-sec)$, when the strength of initial fission source was assumed as $1.0{\times}10^8(n/sec)$. The main reason of these results is due to the thermalization of fast neutrons in the water region and thermal flux is proportional to 80% of total neutron flux. Therefore, optimization of filler material of detector guide tube, position of installation and axial length of detector segments is necessary for the design of ex-core detector to enhance the neutron count rate and above results could be used in ex-core detector design as a fluence requirement.

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

Variation Analysis of Distance and Exposure Dose in Radiation Control Area and Monitoring Area according to the Thickness of Radiation Protection Tool Using the Calculation Model: Non-Destructive Test Field (계산 모델을 활용한 방사선방어용 도구 두께에 따른 방사선관리구역 및 감시구역의 거리 및 피폭선량 변화 분석 : 방사선투과검사 분야 중심으로)

  • Gwon, Da Yeong;Park, Chan-hee;Kim, Hye Jin;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.279-287
    • /
    • 2020
  • Recently, interest in radiation protection is increasing because of the occurrence of accidents related to exposure dose. So, the nuclear safety act provides to install the shields to avoid exceeding the dose limit. In particular, when the worker conducts the non-destructive testing (NDT) without the fixed shielding structure, we should monitor the access to the workplace based on a constant dose rate. However, when we apply for permits for NDT work in these work environments, the consideration factors to the estimation of the distance and exposure dose are not legally specified. Therefore, we developed the excel model that automatically calculates the distance, exposure dose, and cost if we input the factors. We applied the assumption data to this model. As a result of the application, the distance change rate was low when the thickness of the lead blanket and collimator is above 25 mm, 21.5 mm, respectively. However, we didn't consider the scattering and build-up factor. And, we assumed the shape of the lead blanket and collimator. Therefore, if we make up for these limitations and use the actual data, we expect that we can build a database on the distance and exposure dose.