• 제목/요약/키워드: Shield Effect

검색결과 293건 처리시간 0.026초

Field test and numerical study of the effect of shield tail-grouting parameters on surface settlement

  • Shao, Xiaokang;Yang, Zhiyong;Jiang, Yusheng;Yang, Xing;Qi, Weiqiang
    • Geomechanics and Engineering
    • /
    • 제29권5호
    • /
    • pp.509-522
    • /
    • 2022
  • Tail-grouting is an effective measure in shield engineering for filling the gap at the shield tail to reduce ground deformation. However, the gap-filling ratio affects the value of the gap parameters, leading to different surface settlements. It is impossible to adjust the fill ratio indiscriminately to study its effect, because the allowable adjustment range of the grouting quantity is limited to ensure construction site safety. In this study, taking the shield tunnel section between Chaoyanggang Station and Shilihe Station of Beijing Metro Line 17 as an example, the correlation between the tail-grouting parameter and the surface settlement is investigated and the optimal grouting quantity is evaluated. This site is suitable for conducting field tests to reduce the tail-grouting quantity of shield tunneling over a large range. In addition, the shield tunneling under different grouting parameters was simulated. Furthermore, we analyzed the evolution law of the surface settlement under different grouting parameters and obtained the difference in the settlement parameters for each construction stage. The results obtained indicate that the characteristics of the grout affect the development of the surface settlement. Therefore, reducing the setting time or increasing the initial strength of the grout could effectively suppress the development of surface subsidence. As the fill ratio decreases, the loose zone of the soil above the tunnel expands, and the soil deformation is easily transmitted to the surface. Meanwhile, owing to insufficient grout support, the lateral pressure on the tunnel segments is significantly reduced, and the segment moves considerably after being removed from the shield tail.

Field test and research on shield cutting pile penetrating cement soil single pile composite foundation

  • Ma, Shi-ju;Li, Ming-yu;Guo, Yuan-cheng;Safaei, Babak
    • Geomechanics and Engineering
    • /
    • 제23권6호
    • /
    • pp.513-521
    • /
    • 2020
  • In this paper, due to the need for cutting cement-soil group pile composite foundation under the 7-story masonry structure of Zhenghe District and the shield tunnel of Zhengzhou Metro Line 5, a field test was conducted to directly cut cement-soil single pile composite foundation with diameter Ф=500 mm. Research results showed that the load transfer mechanism of composite foundation was not changed before and after shield tunnel cut the pile, and pile body and the soil between piles was still responsible for overburden load. The construction disturbance of shield cutting pile is a complicated mechanical process. The load carried by the original pile body was affected by the disturbance effect of pile cutting construction. Also, the fraction of the load carried by the original pile body was transferred to the soil between the piles and therefore, the bearing capacity of composite foundation was not decreased. Only the fractions of the load carried by pile and the soil between piles were distributed. On-site monitoring results showed that the settlement of pressure-bearing plates produced during shield cutting stage accounted for about 7% of total settlement. After the completion of pile cutting, the settlements of bearing plates generated by shield machine during residual pile composite foundation stage and shield machine tail were far away from residual pile composite foundation stage which accounted for about 15% and 74% of total settlement, respectively. In order to reduce the impact of shield cutting pile construction on the settlement of upper composite foundation, it was recommended to take measures such as optimization of shield construction parameters, radial grouting reinforcement and "clay shock" grouting within the disturbance range of shield cutting pile construction. Before pile cutting, the pile-soil stress ratio n of composite foundation was 2.437. After the shield cut pile is completed, the soil around the lining structure is gradually consolidated and reshaped, and residual pile composite foundation reaches a new state of force balance. This was because the condensation of grouting layer could increase the resistance of remaining pile end and friction resistance of the side of the pile.

연료전지용 쉴드슬롯판의 자중처짐해석 (An analysis for the deflection profile of MCFC shield-slot plate by gravity)

  • 심언태;이경수;우동욱;김지영;김정현;이상욱
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.472-475
    • /
    • 2005
  • In this study, the equivalent physical properties of the shield-slot plate that has a lot of very tiny bridge shape structures on its plane were determined by tensile tests and structural analyses. With those results in hand, numerical analyses for the deflection profile by gravity effect were carried out to compare with experimental results. The two results were shown coincident very well so that the estimated equivalent physical properties were verified enough for further studies such as curvature reduction for the shield-slot plate.

  • PDF

Dynamic Analysis of AP1000 Shield Building Considering Fluid and Structure Interaction Effects

  • Xu, Qiang;Chen, Jianyun;Zhang, Chaobi;Li, Jing;Zhao, Chunfeng
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.246-258
    • /
    • 2016
  • The shield building of AP1000 was designed to protect the steel containment vessel of the nuclear reactor. Therefore, the safety and integrity must be ensured during the plant life in any conditions such as an earthquake. The aim of this paper is to study the effect of water in the water tank on the response of the AP1000 shield building when subjected to three-dimensional seismic ground acceleration. The smoothed particle hydrodynamics method (SPH) and finite element method (FEM) coupling method is used to numerically simulate the fluid and structure interaction (FSI) between water in the water tank and the AP1000 shield building. Then the grid convergence of FEM and SPH for the AP1000 shield building is analyzed. Next the modal analysis of the AP1000 shield building with various water levels (WLs) in the water tank is taken. Meanwhile, the pressure due to sloshing and oscillation of the water in the gravity drain water tank is studied. The influences of the height of water in the water tank on the time history of acceleration of the AP1000 shield building are discussed, as well as the distributions of amplification, acceleration, displacement, and stresses of the AP1000 shield building. Research on the relationship between the WLs in the water tank and the response spectrums of the structure are also taken. The results show that the high WL in the water tank can limit the vibration of the AP1000 shield building and can more efficiently dissipate the kinetic energy of the AP1000 shield building by fluid-structure interaction.

Effect of Shield Line on Noise Margin and Refresh Time of Planar DRAM Cell for Embedded Application

  • Lee, Jung-Hwan;Jeon, Seong-Do;Chang, Sung-Keun
    • ETRI Journal
    • /
    • 제26권6호
    • /
    • pp.583-588
    • /
    • 2004
  • In this paper we investigate the effect of a shield metal line inserted between adjacent bit lines on the refresh time and noise margin in a planar DRAM cell. The DRAM cell consists of an access transistor, which is biased to 2.5V during operation, and an NMOS capacitor having the capacitance of 10fF per unit cell and a cell size of $3.63{\mu}m^2$. We designed a 1Mb DRAM with an open bit-line structure. It appears that the refresh time is increased from 4.5 ms to 12 ms when the shield metal line is inserted. Also, it appears that no failure occurs when $V_{cc}$ is increased from 2.2 V to 3 V during a bump up test, while it fails at 2.8 V without a shield metal line. Raphael simulation reveals that the coupling noise between adjacent bit lines is reduced to 1/24 when a shield metal line is inserted, while total capacitance per bit line is increased only by 10%.

  • PDF

수상함 MIL-SATCOM과 ES간의 전자기 간섭 개선을 위한 EMI 차폐판 최적설계 연구 (A Study on EMI Shield Optimization for Improvement of EMI between MIL-SATCOM and ES on a Surface Ship)

  • 장호성;함영훈;조관준
    • 한국군사과학기술학회지
    • /
    • 제20권1호
    • /
    • pp.63-71
    • /
    • 2017
  • During the sea trial test, we discovered EMI(Electromagnetic Interference) between MIL-SATCOM parabolic antenna and ES(Electronic Warfare Support) omni antenna. Emitted side lobe of CW(Continuous Wave) from MIL-SATCOM raises the threshold level of ES omni antenna. Therefore detection rate of ES is decreased. To solve this problem, the path of side lobe of CW from MIL-SATCOM should be blocked using EMI shield. This paper presents the method how to calculate the size of EMI shield, material, and optimized deployment. The test of the EMI shield effect was performed on a surface ship. After installing EMI shield, EMI has been decreased significantly. This paper will provide a method how to design EMI shield and a way to verify the result.

API강재의 파이버레이저 용접시 유기하는 플라즈마의 방사특성 (III) - 보호가스가 플라즈마 방사 신호에 미치는 영향 - (Characteristics of Plasma Emission Signals in Fiber Laser Welding of API Steel (III) -The Effect on Plasma Emission Signals by Shield Gas-)

  • 이창제;김종도;김유찬
    • Journal of Welding and Joining
    • /
    • 제31권3호
    • /
    • pp.60-65
    • /
    • 2013
  • Ar, $N_2$, and He are the conventional kind of shield gas that are used for laser welding. Many researches on the impact of laser welding shield gas have been done, and it is on going until now. However, there are few studies that analyze the changes and differences of the plasma emission signal. Therefore, in this study, we evaluated the change in the penetration characteristics according to the type of shield gas during fiber laser welding impacts to the plasma signal. As a result, if was checked that the difference in molecular weight of Ar, $N_2$, and He affects to the amount of spatter, and also found that the measured plasma radiation signal changes similar to the order of the molecular weight of the gases. Especially, clear change on the signal intensity per each shield gas was measured through RMS, and found that the shield gas was nothing to do with the FFT analyzed result.

냉동기에 의해 냉각되는 복사열차폐 최적설계 (Design Optimization of Thermal Radiation Shield Cooled by Cryocooler)

  • 최연석;;김동락;양형석;이병섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2171-2174
    • /
    • 2008
  • The design of thermal radiation shield cooled by a cryocooler is presented. This study is motivated mainly by our recent development of prototype superconducting magnet system for the Cyclotron K120. The superconducting magnet system is composed of the magnet cryostat, transfer line and supply cryostat. In order to minimize thermal radiation load, the superconducting coil form in the magnet cryostat is enclosed by the thermal radiation shield which is thermally connected to the first-stage cold head of a two-stage cryocooler in the supply cryostat. Since the supply cryostat is located far from the magnet cryostat large temperature gradient along the thermal shield is unavoidable. In this paper, the thermal radiation shield is optimized to minimize temperature gradient with taking into account the cryogenic load, system structure and electrical load. The effect of heat source from thermal conduction through mechanical supports on the temperature distribution of thermal radiation shield is also discussed.

  • PDF

600MPa급 자동차용 고장렬강판의 $CO_2$ 레이저 용접부의 특성에 미치는 보호가스의 영향 (Effect of shield gas on the characteristics of $CO_2$ laser welded 600MPa grade high strength steel)

  • 한태교;이봉근;강정윤
    • 한국레이저가공학회지
    • /
    • 제7권2호
    • /
    • pp.19-26
    • /
    • 2004
  • The effect of shield gas on the weldability, mechanical properties and formability of CO2 laser weld joint in 600MPa grade high strength steel was investigated. Bead on plate welds were made under various welding speed and shield gas. Tensile test was carried out under the load of perpendicular and parallel direction to the weld line, Formability of the joint was evaluated by Erichsen test. As the welding speed increases, the porosity fraction decreases. The porosity fraction in the joint used Ar-$50\%He$ mixed gas as a shield gas was lower than that of the joint used Ar gas. Hardness at the weld metal of full penetrated joint was nearly equal to that of water quenched raw metal. In a tensile test under a perpendicular load to the weld axis, strength and elongation of joint produced by optimum condition were nearly equal to those of base metal. However, the strength of joint in a tensile test under a parallel load to weld axis was higher than that of raw metal, but the elongation of joint was lower than that of raw metal. Elongation and formability were further increased by the method of using Ar+He mixed gas as a shield gas as compared with Ar gas. Formabilities of joints were recorded ranging from $58\%\;to\;70\%$ of that of base metal with different shield gases.

  • PDF

파이버 레이저를 이용한 순 티타늄 박판의 용접특성 향상을 위한 연구 - 실드가스 노즐변수의 영향 - (The Study for Improving the Weldability of Pure Titanium Sheet by Using Fiber Laser - The Effect of Shielding Gas Nozzle Variable -)

  • 김종도;김지성
    • Journal of Welding and Joining
    • /
    • 제34권5호
    • /
    • pp.6-12
    • /
    • 2016
  • This study was performed bead welding of pure titanium by using fiber laser. Since titanium is very sensitive to oxidation and nitriding during welding, it is important to compose the shielding equipment compared with different material. Thus side and coaxial shield nozzle, rail and chamber type shielding equipment are widely used to protect effectively the weld during welding. Experiments were performed by changing nozzle angle and distance using side and coaxial shield nozzle. The bead colors of gold, brown, blue, purple and yellowish white were obtained by changing variables of shield nozzle, and then its weldability was investigated. As experiment result, sound and not brominated beads were formed when side nozzle angle and distance were respectively $45^{\circ}$ and 10 mm.