• Title/Summary/Keyword: Shell-and-Tube

Search Result 227, Processing Time 0.029 seconds

Modeling of Water Transport in Porous Membrane for PEMFC Humidifer (PEMFC 가습기 용 다공성 중공사막의 물전달 모델링)

  • Hwang, Jun Y.;Park, J.Y.;Kang, K.;Kim, J.H.;Kim, K.J.;Lee, M.S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.96.2-96.2
    • /
    • 2011
  • Water transport through the microporous membrane was modeled considering capillary condensation as well as capillary flow in porous media as a function of pore diameter and relative humidity at the surface. The present model was adopted by the numerical simulation of non-isothermal, non-homogenous flow in a shell and tube typed gas to gas membrane humidifier for PEMFC (proton exchange membrane fuel cell) and the result shows good agreement with experimental data.

  • PDF

Effect of elevated air temperature on shell-and-tube Nafion membrane humidifier in PEMFC system (PEMFC시스템의 공기 공급 온도 변화에 따른 중공사형 나피온 막가습기의 성능특성)

  • Yoon, Jae-Eun;Jang, Hyo-sun;Hwang, Jun-Young;Kang, Kyung-Tae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.345-348
    • /
    • 2009
  • Maintaining proper membrane humidity is crucial to ensure optimal operation of a PEMFC system. A gas-to-gas membrane humidifier is popular technology for external humidification of PEMFC reactant gases. Characteristics of heat and water transfer in shell-and-tube Nafion membrane humidifiers has been experimentally investigated for various dry side inlet temperature of membrane humidifier. The results show that heat flux decreases linearly with dry side inlet temperature of membrane humidifier. The water flux through the membrane varies nonlinearly with the temperature elevation.

  • PDF

A Study on Development of a Plugging Margin Evaluation Method Taking Into Account the Fouling of Shell-and-Tube Heat Exchangers

  • Hwang, Kyeong-Mo;Jin, Tae-Eun;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.11
    • /
    • pp.1934-1941
    • /
    • 2006
  • As the operating time of heat exchangers progresses, fouling caused by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of Korean nuclear power plants have been analyzed in terms of heat transfer rate and overall heat transfer coefficient as a means of heat exchanger management. Except for fouling resulting from the operation of heat exchangers, all the tubes of heat exchangers have been replaced when the number of plugged tubes exceeded the plugging criteria based on design performance sheet. This paper describes a plugging margin evaluation method taking into account the fouling of shell-and-tube heat exchangers. The method can evaluate thermal performance, estimate future fouling variation, and consider current fouling level in the calculation of plugging margin. To identify the effectiveness of the developed method, fouling and plugging margin evaluations were performed at a component cooling heat exchanger in a Korean nuclear power plant.

A Study on the Development of Plugging Margin Evaluation Method Reflected the Fouling of a Shell-and-Tube Heat Exchanger (다관원통형 열교환기의 파울링 현상을 고려한 관막음 여유 평가법 개발 연구)

  • Hwang, Kyeong-Mo;Jin,Tae-Eun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1384-1389
    • /
    • 2004
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of domestic nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions as a means of heat exchanger management. Except for the fouling level generated in operation of heat exchangers, also, all of the tubes of heat exchangers have been replaced when the number of plugged tubes exceeds the plugging criteria based on design performance sheet. This paper describes the plugging margin evaluation mettled reflected the fouling of shell-and-tube heat exchangers, which can evaluate the thermal performance for heat exchangers, estimate the future fouling variations, and reflect the current fouling level. To identify the effectiveness of the developed method, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

A Study on Thermal and Modal Characteristics for EGR System with Dimpled Rectangular Tube (딤플 사각 튜브형 배기 가스 재순환 시스템의 열 및 진동 특성에 관한 연구)

  • Seo, Young-Ho;Heo, Sung-Chan;Kwon, Young-Seok;Ku, Tae-Wan;Kim, Jeong;Kang, Beom-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.115-125
    • /
    • 2008
  • Recently, Exhaust Gas Recirculation (EGR) system which re-flow a cooled exhaust gas from vehicles burning diesel as fuel to a combustion chamber of engine has been used to solve the serious air pollution. For the design and mass production of EGR system, it is essential to ensure structural integrity evaluation. The EGR system consisted of ten dimpled oval core rectangular tubes, two fix-plates, two coolant pipes, shell body and two flanges in this study. To confirm the safety of the designed system, finite element modeling about each component such as the dimpled oval core tube with the dimpled shape and others was carried out. The reliability of EGR system against exhaust gas flow with high temperature was investigated by flow and pressure analysis in the system. Also, thermal and strength analysis were verified the safety of EGR system against temperature change in the shell and tubes. Furthermore, modal analysis using ANSYS was also performed. From the results of FE analysis, there were confirmed that EGR system was safe against the flow of exhaust gas, temperature change in EGR system and vibration on operation condition, respectively.

The Study on Performance Characteristics in Freon Refrigeration System using Shell and Disk Type Heat Exchanger (셸앤디스크형 열교환기를 적용한 프레온 냉동장치의 성능특성 연구)

  • Kim, Yang-Hyun;Park, Chan-Soo;Lee, Seong-Jae;Kim, Jin-Hyun;Ha, Ok-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.579-584
    • /
    • 2005
  • Nowadays heat exchangers that have been applied for freon refrigerating systems, a shell and tube type condenser and a flooded evaporator have been used, but because of their large size, large space for installation and amount of refrigerants are needed. In this study, we will find the most suitable operating condition of shell and disk type optimum heat exchanger which can minimize the amount of a refrigerant and allow its minimum leakage. The condensing pressure of refrigeration system is increased from 15.0bar to 16.0bar and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As a result of study, It revealed that shell and disk type heat exchanger was applicable to the freon refrigeration system

  • PDF

Partial Insulation and Heating Tubes Configuration of Shell and Tube Steam Reformer at Medium Temperature (중온형 원통다관형 수증기 개질기의 부분단열 및 반경방향 분배 구조의 영향)

  • PARK, DAIN;YU, SANGSEOK
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.6
    • /
    • pp.618-626
    • /
    • 2017
  • Conventional high temperature reformers are not suitable for hybrid fuel cell systems that use waste heat as a heat source. So, development of a low temperature type reformer is needed. However, the analysis was conducted in two ways to increase the thermal efficiency, because of low reforming rate due to the low heat source. First, it is a way to ger thermal gain from the outside through partial insulation. In the case of one heat source tube and several heat source tubes, we analyzed the effect of partial heat insulation in some cases. Second, we found the most efficient arrangement of the heat source tubes by changing the location of the heat source tubes. The interpretation was carred out using the COMSOL Mutiphysics program.

The Effect of Cooling Efficiency on Fouling by EGR Cooler Internal Shape (EGR Cooler 내부 형상에 따른 Fouling이 냉각 성능에 미치는 영향)

  • Nam, Youn-Woo;Oh, Kwang-Chul;Lee, Chun-Hwan;Lee, Chun-Beom;Lee, Won-Nam
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.1
    • /
    • pp.101-108
    • /
    • 2011
  • Understanding the exhaust gas recirculation (EGR) cooler fouling in diesel engine is important factor in the durability characteristic of a EGR system. We develope a test rig and PM feeder using carbon black to examine the effect of fouling on EGR cooler devices those were consisted of flat and shell & tube type. The EGR cooler fouling process is a complex interaction involving heat exchanger shape, boundary condition, constitutes, chemistry and operating mode. As the soot deposited to EGR cooler, these formed a thin deposit layer that was less heat exchange than the fresh status of tube enclosing the exhaust gas, resulting in lower heat exchange effectiveness in both type coolers. But these deposits caused different results in pressure drop, it is increased in flat type, but decreased in Shell & tube type of EGR cooler. A cause was estimated from a change of the flow structure and a decrease of contact area as the EGR cooler fouling.

Performance Evaluation of Multi Effect Distillation for Solar Thermal Desalination (태양열 해수담수화를 위한 증발식 다중효용 담수기 성능평가)

  • Joo, Hong-Jin;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.74-79
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3/day$ capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3/hour$ sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8m^3/hour$ for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3/day$ of fresh water. And, Performance ratio of Development Multi effect distillation was about 2.0191.

  • PDF