지중송전계통에서 절연접속함 위치 및 접지방식 변경의 효용성 평가 (Effectiveness Evaluation According to Change of IJ Joint Box Location and Grounding System in Underground Transmission System)

  • 고광만;이종범
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.247-253
    • /
    • 2015
  • Dielectric breakdown accidents have been mainly occurred in the vicinity of service entrance section in underground power transmission systems. One cause among them is due to the excessive component value of sheath located around service entrance of cable. In this paper, as one of the alternative to prevent these accidents, the change of cross bond grounding system and the location change of IJ(Insulation Joint) are suggested. Also, to evaluate effectiveness of this changing system, circulating current and induced voltage of sheath were analyzed in steady and transient state. By comparison of the analytical results for the several possible changing systems, a grounding system and location of IJ which has the smallest sheath component values is proposed. In this paper, analysis to evaluate the proposed system is carried out by EMTP/ATPDraw. It can be used as a valuable operational material to prevent accident of the service entrance section in underground power transmission system.

시스순환전류 저감장치의 적정 설치위치 검토 (A Study on the Proper Installation Location of a Sheath Circulating Current Reduction Equipment)

  • 홍동석;장태인;강지원;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.638-640
    • /
    • 2005
  • 본 논문에서는 지중 실계통에 저감장치의 설치 위치를 다양하게 변경시켰을 경우 시스 순환전류의 변화를 분석하였으며, 그 결과 보통접속함에 저감장치를 설치하였을 경우가 절연접속함에 설치했을 경우에 비해 적은 저감효과를 보임으로써 저감장치 적용지점 선정에 있어 보통접속함의 저감장치 취부를 가능한 자제할 것으로 권하고 있는 국내 기준(안)의 타당성을 확인하였다.

  • PDF

시스전류 저감장치 적용시 고장전류분류율 검토 및 대책 (A Study of Fault Current Distribution Ratio with a Reduction Equipment of Sheath Circulating Current)

  • 홍동석;장태인;강지원;김재승;윤형희;임헌의
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.503-505
    • /
    • 2003
  • 본 논문에서는 방전갭을 이용한 시스 순환 전류 저감장치 보호유닛을 제안하여 SVL형식의 저감장치 보호유닛과 뇌써지시 과도특성을 비교하였으며, 또한 시스 순환전류 저감장치 보호유닛 적용시의 고장전류분류율을 검토한 결과 모든 경우에 대하여 각 접지선의 고장전류분류율이 현행의 기준을 만족함으로써 시스 순환전류 저감장치 보호유닛을 적용한 저감장치의 현장적용 가능성을 제시하였다.

  • PDF

시스순환전류 저감장치 설치시 거리계전기 응동 특성 평가 (Evaluation of Distance Relay Operation Characteristic with the Reduction Devices Installed in Underground Power Cable Systems)

  • 정채균;이종범;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.494-496
    • /
    • 2003
  • This paper analyses the operation characteristic of distance relay when the single line to ground occurs in underground power cable systems that reduction device of sheath circulating current is installed. To apply that reduction device to actual system, the change of line impedance calculated at relay point is also analysed by the connection type of SVLs and fault location, fault inception angle with the installation of reduction device of reactor or not.

  • PDF

362kV GIS 외함 순환전류에 의한 접지본드 과열현상 및 대책 (Investigation and Countermeasure of Sheath Circulating Current in the 362kV GIS)

  • 이제희;김승규;김순태;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.546-548
    • /
    • 2003
  • 본 논문에서는 362kV GIS 외함 유도 순환전류에 의한 접지본드과열에 대하여 원인을 분석하고 대책을 마련하는 것을 목적으로한다. 원인분석에는 접지본드 과열현상과 과열원인을 GIB 시스전류계산식을 이용하여 계산결과를 도출하였고 전자과도해석 프로그램(EMTP : Electromagnetic Transient Program)에 의한 분석을 통하여 원인을 분석하고 대책을 마련하여 과열현상을 방지하고자 한다.

  • PDF

22.9[kV] CNCV케이블 지중배전계통의 3상 비일괄 동심증성선 다중접지방식에 대한 이론적고찰 (A Consideration on 3-Phase Non-Loop, Multiple-Point Ground Method in 22.9[kV] CNCV Underground Cable Systems)

  • 전명수;송중호
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.85-93
    • /
    • 2008
  • 현재 국내에서 사용되고 있는 22.9[kV]-y 배전 방식은 지중 케이블로 전력을 공급하고 있으며, 선로 운영상 배전 케이블 선로의 동심중성선을 케이블 접속 구간마다 3선 일괄 접지하는 3상 일괄 다중접지방식을 채택하고 있다. 이 방식에서는 동심중성선에 부하 전류의 약 40[%](전력구)${\sim}50$[%](관로)의 동심중성선 순환 전류가 발생하고 있다. 본 논문은 이와 같은 문제점을 해결하기 위하여 새로운 3상 비일괄 동심중성선 다중접지방식을 제안하고 있으며, 케이블의 허용전류계산, 케이블 차폐층의 유기전압 및 선로에서 발생하는 유도장애등의 기술적인 문제들을 종합적으로 해석하고 있다.