• 제목/요약/키워드: Shear load

검색결과 2,630건 처리시간 0.024초

집중하중을 받는 철근콘크리트 깊은 보의 전단거동에 대한 실험적 연구 (An Experimental Study on the Shear Behavior of Reinforced Concrete Deep Beams Subject to Concentrated Loads)

  • 송우석;이진섭;양창현;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.273-278
    • /
    • 1994
  • The shear behavior of simply supported reinforced concrete deep beams subject to concentrated loads has been scrutinized experimentally to verify the influence of the structural parameters such as shear span ratio, and the horizontal and vertical web reinforcements. A total of 27 specimens has been tested at the laboratory. In the tests all specimens have failed in shear causing inclined cracks from the load application points to the supports. The load bearing capacities have changed significantly depending on the shear span ratio. The effects of the vertical and horizontal reinforcements on the shear strength and crack initiation and propagation have been carefully checked and analyzed.

  • PDF

탄소섬유시트로 보강된 춤이 큰 철근콘크리트 보의 전단파괴거동(剪斷破壞擧動) (Shear Failure Behaviour of Reinforced Concrete Deep Beam Strengthened by Carbon Fiber Sheets)

  • 조수제;손성현;박성수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권4호
    • /
    • pp.145-153
    • /
    • 1999
  • The major objective of this study is to investigate experimentally the shear strengthening effect of carbon fiber sheets upon reinforced concrete deep beam and shear failure behavior variation of reinforced concrete deep beam strengthened by carbon fiber sheets. Tests are carried out with 6 specimens were shear failure at first loading tests, and with parameters including the types of shear strengthening of carbon fiber sheets (I type, S type, U type), and plies of sheets (2 ply and 1 ply). From the results of test, analyzed load-deflection of midspan, strain variation of main bars and transverse reinforcement, maximum load capacity of strengthened specimens, and compared with the previous test results.

  • PDF

CLT-콘크리트 합성 거동을 위한 전단 연결재 부재 실험과 해석 연구 (Experimental and Analytical Study of Shear Connectors for the CLT-Concrete Composite Floor System)

  • 박아론;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.65-73
    • /
    • 2019
  • This paper assesses the structural performance (force-slip response, slip modulus, and failure modes) of a CLT-concrete composite by conducting fifteen push-out test specimens. In addition, non-linear 3D finite element analysis was also developed to simulate the load-slip behavior of the CLT-concrete specimens under shear load. All 15 test specimens simulating the effect of concrete thickness, connection angle and penetration depth with four different shear connector types were built and tested to evaluate the flexural performance. Experimental results show that the maximum shear capacity for the composite action is obtained when the fixing angle is $90^{\circ}$ and the penetration depth of 95mm for SC normal screw was used to achieve ductile failure compared to other shear connectors.

Seismic performance evaluation of mid-rise shear walls: experiments and analysis

  • Parulekar, Y.M.;Reddy, G.R.;Singh, R.K.;Gopalkrishnan, N.;Ramarao, G.V.
    • Structural Engineering and Mechanics
    • /
    • 제59권2호
    • /
    • pp.291-312
    • /
    • 2016
  • Seismic performance evaluation of shear wall is essential as it is the major lateral load resisting member of a structure. The ultimate load and ultimate drift of the shear wall are the two most important parameters which need to be assessed experimentally and verified analytically. This paper comprises the results of monotonic tests, quasi-static cyclic tests and shake-table tests carried out on a midrise shear wall. The shear wall considered for the study is 1:5 scaled model of the shear wall of the internal structure of a reactor building. The analytical simulation of these tests is carried out using micro and macro modeling of the shear wall. This paper mainly consists of modification in the hysteretic macro model, developed for RC structural walls by Lestuzzi and Badoux in 2003. This modification is made by considering the stiffness degradation effect observed from the tests carried out and this modified model is then used for nonlinear dynamic analysis of the shear wall. The outcome of the paper gives the variation of the capacity, the failure patterns and the performance levels of the shear walls in all three types of tests. The change in the stiffness and the damping of the wall due to increased damage and cracking when subjected to seismic excitation is also highlighted in the paper.

절곡형 전단보강근을 사용한 슬래브-기둥 접합부의 이력 거동 (Hysteretic Behavior of Slab-Column Joint Using Bended Type Shear Reinforcement)

  • 이현호;이도범;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권3호
    • /
    • pp.211-218
    • /
    • 2006
  • 본 연구에서는 거주형 무량판 구조의 뚫림 전단을 방지하기 위한 연속 절곡된 전단 보강근을 개발하였다. 이를 적용한 슬래브-기둥 접합부에 있어 개발 전단 보강근의 뚫림 전단 성능을 평가하기 위하여, 구조 성능 실험을 수행하였다. 실험 변수는 전단보강근이 없는 경우, 개발 전단보강근을 사용한 경우, 헤드 스터드를 사용한 경우이다. 수평하중에 대한 저항성능을 평가하기 위하여 일정축력하에서의 이력 하중 실험을 수행하였다. 실험결과는 전체 변위 및 접합부 강도 등으로 평가되었다. 이러한 결과로부터, 개발된 전단보강근이 층간변위비 거동에 있어 우수한 성능을 보유함을 확인할 수 있었다.

철근콘크리트 전단벽의 접합방식과 대각보강에 따른 내진성능 평가 및 개선 (Improvement and Evaluation for Seismic Resistant Capacity of Reinforced Concrete Shear wall with Connection Types and Diagonal Reinforcement)

  • 신종학;하기주;안준석;주정준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.139-147
    • /
    • 1999
  • Six reinforced concrete shear wall, constructured with fully rigid, slit, and infilled types, were tested under both vertical and cyclic loadings. Experimental programs were carried out to evaluate the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility, under load reversals. All the specimens were modeled in one-third scale size. Based on the test results, the following conclusions can be made. For the diagonal reinforced slit and infilled shear wall specimens, it was found that the failure mode shows very effective crack control and crushing due to slippage prevention of boundary region and reduction of diagonal tension rathar than the brittle shear and diagonal tension failure. The ductility of specimens designed by the diagonal reinforcement for the slit and infilled shear wall was increased 1.72~1.81 times in comparison with the fully rigid shear wall frame. Maximum horizontal load-carrying capacity of specimens designed by the diagonal reinforcement ratio the slit and infilled shear wall was increased respectively by l.14 times and l.49 times in comparison with the standard fully rigid shear wall frame.

  • PDF

Shear behavior of short square tubed steel reinforced concrete columns with high-strength concrete

  • Li, Xiang;Zhou, Xuhong;Liu, Jiepeng;Wang, Xuanding
    • Steel and Composite Structures
    • /
    • 제32권3호
    • /
    • pp.411-422
    • /
    • 2019
  • Six shear-critical square tubed steel reinforced concrete (TSRC) columns using the high-strength concrete ($f_{cu,150}=86.6MPa$) were tested under constant axial and lateral cyclic loads. The height-to-depth ratio of the short column specimens was specified as 2.6, and the axial load ratio and the number of shear studs on the steel shape were considered as two main parameters. The shear failure mode of short square TSRC columns was observed from the test. The steel tube with diagonal stiffener plates provided effective confinement to the concrete core, while welding shear studs on the steel section appeared not significantly enhancing the seismic behavior of short square TRSC columns. Specimens with higher axial load ratio showed higher lateral stiffness and shear strength but worse ductility. A modified ACI design method is proposed to calculate the nominal shear strength, which agrees well with the test database containing ten short square TSRC columns with shear failure mode from this study and other related literature.

Investigating loading rate and fibre densities influence on SRG - concrete bond behaviour

  • Jahangir, Hashem;Esfahani, Mohammad Reza
    • Steel and Composite Structures
    • /
    • 제34권6호
    • /
    • pp.877-889
    • /
    • 2020
  • This work features the outcomes of an empirical investigation into the characteristics of steel reinforced grout (SRG) composite - concrete interfaces. The parameters varied were loading rate, densities of steel fibres and types of load displacement responses or measurements (slip and machine grips). The following observations and results were derived from standard single-lap shear tests. Interfacial debonding of SRG - concrete joints is a function of both fracture of matrix along the bond interface and slippage of fibre. A change in the loading rate results in a variation in peak load (Pmax) and the correlative stress (σmax), slip and machine grips readings at measured peak load. Further analysis of load responses revealed that the behaviour of load responses is shaped by loading rate, fibre density as well as load response measurement variable. Notably, the out-of-plane displacement at peak load increased with increments in load rates and were independent of specimen fibre densities.

전단하중을 받는 알루미늄 하니콤 샌드위치의 체결방식이 체결부의 파손에 미치는 영향 연구 (Effect of joining methods on the failure of aluminum honeycomb sandwich joints under shear loading)

  • 박용빈;권진회;최진호;조현일
    • 한국항공우주학회지
    • /
    • 제39권7호
    • /
    • pp.643-651
    • /
    • 2011
  • 본 논문에서는 전단하중을 받는 다양한 알루미늄 샌드위치 체결부의 파손 특성에 대한 시험 연구를 수행하였다. 3종류의 인서트 형식 체결부와 2종류의 포팅 형식 체결부에 대해 총 60개의 시편을 제작하여 시험을 수행하였다. 시험 결과, 인서트 형식 체결부의 경우 쓰루 클리어런스(through-clearance) 인서트를 사용한 경우의 파손하중이 가장 높게 나타났으며 포팅 형식 체결부의 경우 딤플 와셔(dimple washer)가 있을 때 전단하중이 약10% 향상되는 것을 확인할 수 있었다. 예상대로 면재의 두께가 증가할수록 전단파손하중도 증가하고, 특히 하중치구와 접촉하고 있는 상부 면재의 효과가 지배적인 것을 확인하였다.

토사지반에 설치된 역 T형 옹벽의 저판형상이 활동거동에 미치는 영향 (Effects of Base Shape of Cantilever Retaining Wall in Soil Foundation on the Sliding Behavior)

  • 유남재;이명욱;김영길;이종호
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.135-145
    • /
    • 1999
  • This thesis is to investigate the sliding behavior of cantilever retaining wall by using the commercially available program of FLAC to simulate its behavior numerically. Cantilever retaining walls with flat base, sloped base and base with shear key, uniform surcharges being applied on the surface of backfill, were investigated to figure out appropriate location of shear key beneath the base of wall and, thus, its applicability to field condition was assessed by comparing the analyzed results to each other. On the other hand, previously performed centrifuge model test results (Eum, 1996) were analyzed numerically with FLAC to compare test results with respect to characteristics of load-settlement of surcharges and load-lateral movement of wall. Based on the failure mechanism observed during centrifuge tests, limit equilibrium method of finding the ultimate load inducing the sliding failure of wall was used to compare with values of the ultimate load obtained from conventional method of limit equilibrium method. Therefore, appropriate location of shear key was determined to mobilize the maximum resistance against sliding failure of wall.

  • PDF