• 제목/요약/키워드: Shear connections

검색결과 386건 처리시간 0.032초

Effects of Dissolved Oxygen on Fungal Morphology and Process Rheology During Fed-Batch Processing of Ganoderma lucidum

  • Fazenda, Mariana L.;Harvey, Linda M.;McNeil, Brian
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권4호
    • /
    • pp.844-851
    • /
    • 2010
  • Controlling the dissolved oxygen (DO) in the fed-batch culture of the medicinal mushroom Ganoderma lucidum led to a 2-fold increase of the maximum biomass productivity compared with uncontrolled DO conditions. By contrast, extracellular polysaccharide (EPS) production was two times higher under oxygen limitation (uncontrolled DO) than under increased oxygen availability (controlled DO). Morphologically, dispersed mycelium was predominant under controlled DO conditions, with highly branched hyphae, consistent with the enhanced culture growth noted under these conditions, whereas in the uncontrolled DO process mycelial clumps were the most common morphology throughout the culture. However, in both cultures, clamp connections were found. This is an exciting new finding, which widens the applicability of this basidiomycete in submerged fermentation. In rheological terms, broths demonstrated shear-thinning behavior with a yield stress under both DO conditions. The flow curves were best described by the Herschel-Bulkley model: flow index down to 0.6 and consistency coefficient up to 0.2 and 0.6 Pa $s^n$ in uncontrolled and controlled cultures DO, respectively. The pseudoplastic behavior was entirely due to the fungal biomass, and not to the presence of EPS (rheological analysis of the filtered broth showed Newtonian behavior). It is clear from this study that dissolved oxygen tension is a critical process parameter that distinctly influences G. lucidum morphology and rheology, affecting the overall performance of the process. This study contributes to an improved understanding of the process physiology of submerged fermentation of G. lucidum.

Cyclic behavior of steel I-beams modified by a welded haunch and reinforced with GFRP

  • Egilmez, O. Ozgur;Alkan, Deniz;Ozdemir, Timur
    • Steel and Composite Structures
    • /
    • 제9권5호
    • /
    • pp.419-444
    • /
    • 2009
  • Flange and web local buckling in beam plastic hinge regions of steel moment frames can prevent beam-column connections from achieving adequate plastic rotations under earthquake-induced forces. Reducing the flange-web slenderness ratios (FSR/WSR) of beams is the most effective way in mitigating local member buckling as stipulated in the latest seismic design specifications. However, existing steel moment frame buildings with beams that lack the adequate slenderness ratios set forth for new buildings are vulnerable to local member buckling and thereby system-wise instability prior to reaching the required plastic rotation capacities specified for new buildings. This paper presents results from a research study investigating the cyclic behavior of steel I-beams modified by a welded haunch at the bottom flange and reinforced with glass fiber reinforced polymers at the plastic hinge region. Cantilever I-sections with a triangular haunch at the bottom flange and flange slenderness ratios higher then those stipulated in current design specifications were analyzed under reversed cyclic loading. Beam sections with different depth/width and flange/web slenderness ratios (FSR/WSR) were considered. The effect of GFRP thickness, width, and length on stabilizing plastic local buckling was investigated. The FEA results revealed that the contribution of GFRP strips to mitigation of local buckling increases with increasing depth/width ratio and decreasing FSR and WSR. Provided that the interfacial shear strength of the steel/GFRP bond surface is at least 15 MPa, GFRP reinforcement can enable deep beams with FSR of 8-9 and WSR below 55 to maintain plastic rotations in the order of 0.02 radians without experiencing any local buckling.

Seismic performance of a fiber-reinforced plastic cable-stayed bridge

  • Hodhod, Osama A.;Khalifa, Magdi A.
    • Structural Engineering and Mechanics
    • /
    • 제5권4호
    • /
    • pp.399-414
    • /
    • 1997
  • This paper presents an investigation into the seismic response characteristics of a proposed ligh-weight pedestrian cable-stayed bridge made entirely from Glass Fiber Reinforced Plastics(GFRP). The study employs three dimensional finite element models to study and compare the dynamic characteristics and the seismic response of the GFRP bridge to a conventional Steel-Concrete (SC) cable-stayed bridge alternative. The two bridges were subjected to three synthetic earthquakes that differ in the frequency content characteristics. The performance of the GFRP bridge was compared to that of the SC bridge by normalizing the live load and the seismic internal forces with respect to the dead load internal forces. The normalized seismically induced internal forces were compared to the normalized live load internal forces for each design alternative. The study shows that the design alternatives have different dynamic characteristics. The light GFRP alternative has more flexible deck motion in the lateral direction than the heavier SC alternative. While the SC alternative has more vertical deck modes than the GFRP alternative, it has less lateral deck modes than the GFRP alternative in the studied frequency range. The GFRP towers are more flexible in the lateral direction than the SC towers. The GFRP bridge tower attracted less normalized base shear force than the SC bridge towers. However, earthquakes, with peak acceleration of only 0.1 g, and with a variety of frequency content could induce high enough seismic internal forces at the tower bases of the GFRP cable-stayed bridge to govern the structural design of such bridge. Careful seismic analysis, design, and detailing of the tower connections are required to achieve satisfactory seismic performance of GFRP long span bridges.

공동주택용 프리캐스트 콘크리트 보-기둥 연결부의 거동분석 (Evaluation on the Behaviors of Precast Concrete Beam-Column Connections for Apartments)

  • 송형수;유승룡
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.657-666
    • /
    • 2006
  • 본 연구에서는 공동주택 리모델링에 활용할 수 있는 완전 건식공법에 의한 프리캐스트 콘크리트 보-기둥 연결부를 개발하는데 있다. 독일에서 개발한 DDC 연결부를 국내 실정에 적합하도록 그 개선모델을 제안하기 위하여 총 5개의 건식연결부 시험체를 제작하였다. 아울러, 아파트 외곽보로 활용할 경우를 고려하여, H형 철물을 사용하여 기둥과 보의 폭을 최소화하였다. 실험결과 보-기둥 연결부에 DDC 시스템을 적용하게 되면 역학적 특성의 향상을 기대할 수 있었으나 기둥에 발생한 경사균열에 의하여 주도적으로 파괴 메커니즘이 형성되는 취약성을 초래하였다. 고가의 DDC 시스템의 덕타일 로드를 대신하여 고강도 강봉을 적용한 공법은 DDC 연결부와 역학적 특성은 유사한 거동을 보였으며, 파괴 메커니즘은 더 우수한 것으로 나타났다. 또한 연결부에 연결철근을 쉬스관 안에 그라우팅하여 부착시키게 되면, 비부착 시키는 공법보다 역학적 특성을 향상시킬 수 있을 것으로 판단된다.

CFT 기둥-RC 무량판 슬래브 외부접합부의 횡저항 성능 (Lateral Resisting Capacity for CFT Column to RC Flat Plate Slab Exterior Connections)

  • 송호범;송진규;오상원;김병조
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.61-64
    • /
    • 2008
  • 콘크리트충전 강관기둥(Concrete Filled steel Tube Column)과 RC 무량판 슬래브의 조합은 거푸집을 사용하지 않는다는 것만으로도 초고층 건물의 공기단축에 상당한 영향을 미칠 수 있다. 뿐만 아니라 기둥의 내력 증진으로 인한 기둥 크기의 축소, 그로 인한 공간 활용도의 증가, 층간 소음문제 해결 등 많은 장점이 잠재되어 있다. 하지만 접합부의 성능을 정확히 밝혀내는 것이 우선 이루어져야 하며, 본 논문에서는 기존에 수행된 CFT 기둥-RC 무량판 슬래브의 내부접합부에 대한 중력 실험과 횡하중 실험을 바탕으로 외부접합부에 대한 실물대 실험을 수행하였다. 외부접합부 실험 결과, 내부접합부 실험체에 비하여 동일한 조건에서 설계된 외부접합부 실험체는 최대 모멘트강도가 $50%{\sim}65%$ 감소하였고, 내진밴드가 추가된 CFT-E2 실험체는 BME 실험체에 비하여 20%의 최대모멘트 증진과 탁월한 연성능력, 에너지 흡수능력을 보유한 것으로 나타났다. 또한 CFT-E2는 내진밴드의 사용으로 슬래브의 휨거동 영역이 확장되었으며 모든 실험체가 설계기준에서 요구하는 0.4V$_c$중력하중 하에서 1.5% 횡변 위비를 만족하였다.

  • PDF

기둥-보 뼈대구조를 위한 각부 접합부의 모멘트저항성능 (Moment Resistance Performance of Each Joint for Post-Beam Frame Structure)

  • 박주생;황권환
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권1호
    • /
    • pp.8-14
    • /
    • 2011
  • 한국 전통 목구조양식에서 뼈대구조인 기둥-보 접합부를 이용하여 현대적인 기법을 적용한 목구조 접합을 개발하기 위하여 낙엽송 집성재를 구조부재로 사용하였다. 집성재를 이용한 전통 접합기술과 드리프트핀 접합으로 구성된 접합부의 부재는 공장에서 프리커트에 의해 가공하였다. 뼈대구조의 전체 성능을 파악하고 향상시키기 위한 기초 연구로서 핀접합부의 인발내력 시험과 각 접합부의 모멘트저항 시험을 행하였다. 본 연구에서 사용된 기둥-보 부재는 본 연구에서 사용된 주각부 및 보단부 접합철물로 이루어진 접합부에서 우수한 모멘트저항성능을 발휘하였다. 핀의 세장비에 따라 초기강성은 세장비가 클수록 다소 높게 나타났으며, 모멘트저항성능인 휨모멘트와 최대모멘트는 세장비가 작을수록 우수함을 알 수 있었다.

51 mm 대구경 철근을 사용한 외부 보-기둥 접합부의 정착상세별 구조성능 평가 (Structural Performance of Beam-Column Connections Using 51 mm Diameter with Different Anchorage Details)

  • 김정엽;정형석;천성철;김인호;최창식
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.201-208
    • /
    • 2017
  • 외부 보-기둥 접합부에서는 철근정착을 위해 갈고리철근 사용하고 있으며, 철근과밀배근 해소와 시공작업의 어려움으로 확대머리철근의 사용이 증가하고 있다. SD600 51 mm 확대머리철근을 사용할 경우 ACI318-14 및 KCI2012기준에서 사용을 제한하고 있다. 이번 연구에서는 외부 보-기둥 접합부 내에 고강도 대구경 철근의 확대머리 철근의 사용이 가능하도록 실험 60 MPa, 80 MPa 콘크리트강도로 제작된 실험체의 정착상세별 구조성능을 평가하였다. 모든 실험체에서는 보의 휨항복파괴가 발생하였으며, 실험체의 모멘트-변위 곡선에서 비슷한 양상을 보였다. 다른 실험체보다 갈고리가 한쪽방향으로 배근한 실험체에서는 갈고리철근 배근방향에 의해 전단저항능력이 달라지므로 3.5%변위비 이후에 부착응력 감소가 더 크게 나타났으며, 전단변형능력도 더 크게 나타났다. 실험체의 내진성능을 확인하기 위하여 ACI374.1-05기준과 비교하였으며, 실험결과 충분한 내진성능을 확보하였다. 이를 통하여 외부 보-기둥 접합부에서 SD600, 51 mm 확대머리철근의 사용이 가능한 것으로 판단된다.

반복하중을 받는 프리캐스트 콘크리트 건식 보-기둥 연결부의 거동분석 (Analysis on the Behaviors of Precast Concrete Beam-Column Connections Subject to Cyclic Loading)

  • 송형수;유승룡
    • 콘크리트학회논문집
    • /
    • 제18권4호
    • /
    • pp.497-506
    • /
    • 2006
  • 본 연구에서는 주상복합건물에 적용가능한 건식공법에 의한 프리캐스트 콘크리트 보-기둥 연결부에 대하여 실험을 통하여 분석하였다. 현재 국내에 활용하고 있는 프리캐스트 콘크리트 보-기둥 연결부와 현재 미국에서 사용되고 있는 DDC 연결부, 그리고 DDC 연결부와 개선된 연결부에 포스트텐션을 도입한 시험체를 제작하였고, 실험을 통하여 그 거동을 평가하였다. 실험 결과 보-기둥 연결부에 DDC 시스템을 적용하게 되면 연결부의 강도와 연성능력의 향상을 기대할 수 있었으나 파괴 메커니즘이 보에 에너지를 분산시키지 않고, 연결부에서 사인장 균열에 의하여 에너지를 소산시키게 되어 연결부가 파괴되는 단점이 나타났다. 개량 DDC 연결부는 기둥에 사인장균열이 발생하지 않고 보다 연성적인 파괴거동을 보여주었다. 또한 보-기둥 연결부에 포스트텐션의 도입은 연결부 강도의 증가는 크게 기대할 수 없었으나 자가조정(self-centering) 등을 통하여 연결부의 안정성 및 연성능력에 기여하는 것으로 나타났다.

프리캐스트 콘크리트 벽체 수직접합부의 광폭형 연결방식 개발 (Development of Wide Connection Method for Vertical Joints of Precast Concrete Walls)

  • 최은규;신영수
    • 콘크리트학회논문집
    • /
    • 제21권5호
    • /
    • pp.549-556
    • /
    • 2009
  • 이 연구에서는 프리캐스트 콘크리트 구조시스템에서 기존에 사용되고 있는 벽체의 수직접합부의 시공 및 문제점을 최소화하기 위해 접합부의 폭을 100 mm에서 150 mm로 증가시키고 연결방식을 3가지로 하여 구조적 성능 및 적용성에 대해 분석하였다. 또한, 해석적으로 구조적 성능을 파악하기 위해 비선형 유한 요소 해석법으로 분석하였다. 분석 결과, 광폭형 연결부를 가진 접합부를 적용하였을 때, PC벽체에 가해지는 하중을 더 효율적으로 철근이 분담하여 내력이 증가하고 연성적인 거동을 하는 것으로 나타났다. 또한, 접합부 루프근의 단면적이 커질수록 그리고 철근 개수가 증가할수록 최대내력이 증가하며 광폭형 접합부 형식 중에 용접형-링형-C형의 순서로 내력이 큰 것으로 나타났다. 용접형의 경우 현장조건에 따른 변화가 발생할 수 있으므로 광폭형 연결 부위를 링형 접합부로 하는 것이 안정적인 거동을 하며 현장 용접의 철저한 품질관리가 필요하다.

리브 보강된 SC구조 벽-바닥 접합부의 거동 및 내력 평가 (Behavior and Strength of Rib Stiffened SC Wall-slab Connection)

  • 박정학
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.349-359
    • /
    • 2014
  • 강판콘크리트(SC)구조 벽-바닥접합부는 표면 강판에 의해 콘크리트가 나뉘게 되며 이 때문에 바닥 단부의 응력 전달기구가 RC구조의 것과 다를 것으로 예상된다. 따라서 본 연구에서는 리브가 부착된 SC구조 벽-바닥 실험체의 거동 및 내력평가를 수행하였다. 리브가 부착된 SC벽바닥 접합부의 접합성능을 확인하기위하여 7가지의 접합부 모형을 제작하고 단조 가력실험을 수행하여 구조내력 및 거동특성을 실험결과분석을 통해 고찰하였다. 제안식의 신뢰성을 확보하기위해 유한요소 해석을 수행하였다. 실험체 변수로는 가력지점, 마찰계수이며 이들의 영향에 대해 검토되었다. 실험체 파괴모드 분석을 통해 접합부 내력을 확인하였다. 제안식은 대부분 보수적인 값으로 확인되었다.