Shear capacity equation for channel shear connectors in steel-concrete composite beams

  • Paknahad, Masoud;Shariati, Mahdi;Sedghi, Yadollah;Bazzaz, Mohammad;Khorami, Majid
    • Steel and Composite Structures
    • /
    • v.28 no.4
    • /
    • pp.483-494
    • /
    • 2018
  • In this research the effect of high strength concrete (HSC) on shear capability of the channel shear connectors (CSC) in the steel concrete composite floor system was estimated experimentally and analytically. The push-out test was carried out for assessing the accurateness of the proposed model (nonlinear and finite element model) for the test specimens. A parametric analysis was conducted for predicting the shear capacity of the connectors (CSC) in the HSC. Eight push-out specimens of different sizes with different strength levels were tested under the monotonic loading system. The aim of this study was to evaluate the efficacy of the National Building Code of Canada (NBC) of Canada for analysing the loading abilities of the CSC in the HSC. Using the experimental tests results and verifying the finite element results with them, it was then confirmed by the extended parametric studies that the Canadian Design Code was less efficient for predicting the capacity of the CSC in the HSC. Hence, an alternative equation was formulated for predicting the shear capacity of these connectors during the inclusion of HSC for designing the codes.

Strength and Deformation Characteristics of Steel Fiber Reinforced Columns (강섬유 보강 기둥의 강도 및 변형 특성)

  • 장극관;이현호;양승호
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.49-57
    • /
    • 2002
  • As composite materials, the addition of steel fiber with concrete significant)y improves the engineering properties of structural members, notably shear strength and ductility. Flexural strength, fatigue strength, and the capacity to resist cracking are also enhanced. Especially the strengthening effect of steel fiber in shear is to prevent the brittle shear failure. In this study, shear-strengthening effect of steel fiber in RC short columns were investigated from the literature surveys and 10th specimem's member test results. From the test results, following conclusions can be made; the maximum enhancement of shear-strengthening effect can be achieved at about 1.5 % of steel fiber contents, shear strength and ductility capacity were improved remarkably in comparison to stiffness and energy dissipation capacity in steel fiber reinforced concrete.

Shear behavior and shear capacity prediction of precast concrete-encased steel beams

  • Yu, Yunlong;Yang, Yong;Xue, Yicong;Liu, Yaping
    • Steel and Composite Structures
    • /
    • v.36 no.3
    • /
    • pp.261-272
    • /
    • 2020
  • A novel precast concrete-encased steel composite beam, which can be abbreviated as PCES beam, is introduced in this paper. In order to investigate the shear behavior of this PCES beam, a test of eight full-scale PCES beam specimens was carried out, in which the specimens were subjected to positive bending moment or negative bending moment, respectively. The factors which affected the shear behavior, such as the shear span-to-depth aspect ratio and the existence of concrete flange, were taken into account. During the test, the load-deflection curves of the test specimens were recorded, while the crack propagation patterns together with the failure patterns were observed as well. From the test results, it could be concluded that the tested PCES beams could all exhibit ductile shear behavior, and the innovative shear connectors between the precast concrete and cast-in-place concrete, namely the precast concrete transverse diaphragms, were verified to be effective. Then, based on the shear deformation compatibility, a theoretical model for predicting the shear capacity of the proposed PCES beams was put forward and verified to be valid with the good agreement of the shear capacities calculated using the proposed method and those from the experiments. Finally, in order to facilitate the preliminary design in practical applications, a simplified calculation method for predicting the shear capacity of the proposed PCES beams was also put forward and validated using available test results.

Strain-Based Shear Strength Model for fiber Reinforced Concrete Beams (섬유보강 콘크리트 보를 위한 변형 기반 전단강도모델)

  • Choi Kyoung-Kyu;Park Hong-Gun;Wight James K.
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.911-922
    • /
    • 2005
  • A theoretical study was performed to investigate the behavioral chracteristics and shear strength of fiber reinforced concrete slender beams. In the fiber reinforced concrete beam, the shear force applied to a cross section of the beam was resisted by both compressive zone and tensile zone. The shear capacity of the compressive zone was defined addressing the interaction with the normal stresses developed by the flexural moment in the cross section. The shear capacity of the tensile zone was defined addressing the post-cracking tensile strength of fiber reinforced concrete. Since the magnitude and distribution of the normal stresses vary according to the flexural deformation of the beam, the shear capacity of the beam was defined as a function of the flexural deformation of the beam. The shear strength of the beam and the location of the critical section were determined at the intersection between the shear capacity and shear demand curves. The proposed method was developed as a unified shear design method which is applicable to conventional reinforced concrete as well as fiber reinforced concrete.

Strain-Based Shear Strength Model for Prestressed Concrete Beams (프리스트레스트 콘크리트 보를 위한 변형률 기반 전단강도 모델)

  • Kang, Soon-Pil;Park, Hong-Gun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.197-200
    • /
    • 2008
  • An analytical model for predicting the shear strength of prestressed concrete beams was developed, applying the previously proposed strain-based shear strength model. In flexure-compression member without shear reinforcement, compression zone of intact concrete primarily resist to the shear force rather than tension zone. The shear capacity of concrete at the compression zone was defined based on the material failure criteria. The shear capacity of the compression zone was evaluated along the inclined failure surface considering interaction with the normal stress. Since the distribution of normal stress varies due to the flexural deformation of member, the shear capacity was defined as a function of the flexural deformation. Finally, the shear strength was determined at the intersection of the shear capacity curve and the shear demand curve. As a result of the comparisons to prior test data, the proposed model accurately predicted the shear strength of specimens.

  • PDF

Numerical assessment of post-tensioned slab-edge column connection systems with and without shear cap

  • Janghorban, Farshad;Hoseini, Abdollah
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.71-81
    • /
    • 2018
  • Introduction of prestressed concrete slabs based on post-tensioned (PT) method aids in constructing larger spans, more useful floor height, and reduces the total weight of the building. In the present paper, for the first time, simulation of 32 two-way PT slab-edge column connections is performed and verified by some existing experimental results which show good consistency. Finite element method is used to assess the performance of bonded and unbonded slab-column connections and the impact of different parameters on these connections. Parameters such as strand bonding conditions, presence or absence of a shear cap in the area of slab-column connection and the changes of concrete compressive strength are implied in the modeling. The results indicate that the addition of a shear cap increases the flexural capacity, further increases the shear strength and converts the failure mode of connections from shear rigidity to flexural ductility. Besides, the reduction of concrete compressive strength decreases the flexural capacity, further reduces the shear strength of connections and converts the failure mode of connections from flexural ductility to shear rigidity. Comparing the effect of high concrete compressive strengths versus the addition of a shear cap, shows that the latter increases the shear capacity more significantly.

Hysteretic Behavior of Slab-Column Joint Using Bended Type Shear Reinforcement (절곡형 전단보강근을 사용한 슬래브-기둥 접합부의 이력 거동)

  • Lee, Hyun-Ho;Lee, Do-Bum;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.211-218
    • /
    • 2006
  • From the development of residential flat plate system, continuously bended shear reinforcement is developed for the prevention of punching shear. To know the punching shear capacity of developed shear reinforcement in slab-column joint, structural test is performed. The testing parameters are shear reinforcement types, such as no reinforcement, bended shear reinforcement, and head stud reinforcement. To verify the lateral capacity, cyclic load is applied under the constant vertical load condition. The results of tests are compared to as global displacement, slab-column joint strength. From the test results, the resisting capacity of developed shear reinforcement system has a good performance in the story drift ratio.

Shear Strength Evaluation in Masonry Assemblages by Reinforcing Materials in Joint (줄눈 보강을 통한 면내 방향의 조적조 사인장 전단강도 평가)

  • Woo, Jong-Hun;Shin, Kyung-Jae;Lee, Jun-Seop;Han, Seung-Yun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.191-198
    • /
    • 2019
  • All over the Republic of Korea, there are many masonry buildings which have been built since 1970s. When the earthquake at Po-Hang occurred, this is the main cause of huge damage because the masonry buildings have not seismic capacity. When masonry buildings are failed, two type of the failure modes can be shown, which are in-plane mode and out-plane mode. In-plane mode can have seismic capacity in masonry so diagonal shear test is performed in this study. The purpose of this study was to find the best way to reinforce the materials through the diagonal shear test. Through the test, shear stress and shear modulus of elasticity will be calculated, referred to the ASTM E 519-02. The variables in this test are ${\phi}3$ wire, three types of wire meshes, polypropylene strap and different types of brick. Each variable is applied to the same condition of the $1.2m{\times}1.2m$ masonry walls which are made by ASTM E 519-02. Compared to each variable with shear stress and shear modulus of elasticity, the best way of reinforcing method to have seismic capacity will be proved in this study.

Dynamic Property Evaluation of Lead Rubber Bearing by Shear Loading (적층고무베어링의 동적 특성평가)

  • 이경진;김갑순;강태경;서용표;이종림
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.367-372
    • /
    • 2002
  • In these days, The base isolation system is often used to improve the seismic capacity of the structures instead of conventional techniques of strengthening the structural members. The purpose of this study is to evaluate dynamic properties and mechanical characteristics of the 10tonf-LRB(Lead-Rubber Bearing). Experimental studies were performed to obtain the hysteretic behavior, effective shear stiffness( $K_{eff}$), equivalent damping( $H_{eq}$ ), capacity of energy dissipation( $W_{D}$) of six 10tonf-LRB. Especially, in this study, the response of the LRB for high loading frequency(0.5Hz~3.0Hz) was estimated. The effective shear stiffness of the LRB decreases and the capacity of energy dissipation increases as the shear strain amplitude increases. But the shear behavior of the LRB is not affected sensitively by loading frequency.y.y.

  • PDF

Design of composite plate girders under shear loading

  • Shanmugam, N.E.;Baskar, K.
    • Steel and Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.1-14
    • /
    • 2006
  • Experiments have been carried out on six composite and two plain steel plate girders under shear loading to understand the elastic and inelastic behaviour of such girders. The failure mechanism assumed and used to develop design equations is normally based on the failure patterns observed in the experiments. Therefore, different types of cracks and failure patterns observed in the experiments are reviewed briefly first. Based on the observed failure patterns, a design method to predict the ultimate shear capacity of composite plate girders is proposed in this paper. The values of ultimate shear capacity obtained using the proposed design method are compared with the corresponding experimental values and it is found that the proposed method is able to predict the shear capacity accurately.