• Title/Summary/Keyword: Shear bond strength to dentin

Search Result 174, Processing Time 0.034 seconds

임시접착 후, 치면세마에 따른 Lithium Disilicate Glass-Ceramic의 레진결합강도에 대한 연구 (Resin Bond Strength of Lithium Disilicate Glass-Ceramic by Surface Cleansing Method after Temporary Cementation)

  • 정승화;이진한;오상천
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.259-268
    • /
    • 2007
  • purpose: This study was to evaluate the shear bond strength of Lithium Disilicate Glass-Ceramic by removable method of temporary cement on the abutment tooth. Material and Method: Sixty molar teeth of human with the occlusal surface up were mounted in acrylic resin blocks. The 45 specimens were prepared to exposure dentin by diamond bur and the eugenol-containing temporary cement($Cavitec^{TM}$ ($KERR^{(R)}$, U.S.A)was applied to the dentin surfaces. After initial removal of the cement with a dental explorer, the specimens were divided into 4 groups of 15 specimens each. The dentin surfaces of the specimens were treated by rotary instrument with as follow pastes: $Zircate^{(R)}$ prophy paste(Dentsply, U.S.A), Radent Prophy Paste(Pascal company,inc. U.S.A), and Dental pumice(Wip mix corporation,U.S.A). An adhesive resin luting agent(Variolink $II^{(R)}$, Ivoclar Vivadent, Leichtenstein) including Monobond-S and $Excite^{(R)}$ was applied to all specimens. The ceramic specimens were made with an A1 ingot of IPS Empress $II^{(R)}$ (Ivoclar Vivadent, Leichtenstein). After the specimens were stored in distilled water for 48hr, the shear bond strength(MPa) was measured by a Universal testing machine(Zwick 145641, Zwick, Germany) at a 1mm/min cross-head speed. The data were statistically analyzed by one-way ANOVA and Duncan's multiple range test. Results: In all group, there were no significant differences in comparison with the control group(p>0.05). The pattern of most failure showed the mixed type of cohesive and adhesive failure. Conclusion: Resin bond strength of IPS Empress $II^{(R)}$ was not affected by removal method of the temporary cement.

아르곤 레이저의 조사시간에 따른 광중합형 글래스 아이오노머 시멘트의 상아질에 대한 전단결합강도에 관한 연구 (A STUDY ON THE SHAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER CEMENTS TO DENTIN ACCORDING TO CURING TIME INDUCED BY ARGON LASER)

  • 조영린;황호길;조영곤;오행진
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.267-277
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of light-cured glass ionomer cements to dentin surface according to curing time induced by argon laser. In this study, 160 extracted human molars with sound crown were used. The dentin surface of these teeth were exposed with high speed diamond bur under water spray and polished with 120, 320, 400, 800, 1200 grits sand paper. 160 extracted human molars were randomly assigned into four groups (control, experimental 1, 2 & 3) with 40 teeth each. Control group used a visible light curing unit, XL 1000(3M Co., U.S.A) and experimental groups used argon laser($SPECTRUM^{TM}$). And then each group subdivided into two groups (A, B) according to filling materials. Subdivided A group used Fuji II LC(GC Co., Japan), B group used Vitremer(3M Co., U.S.A). The curing units and curing time of each group were as follows : Control group : visible light, 40 seconds Experimental group 1 Experimental group 2 Experimental group 3 : argon laser, 10 seconds : argon laser, 20 seconds : argon laser, 30 seconds The glass ionomer cements were bonded to dentin surface of each specimen. The specimens were stored in 100% relative humidity at 37"c for 7days. And then, the shear bond strength were measured by universal testing machine(Shimatzu Co. Japan) at crosshead speed of 5mm/min and 100kg in full scale and analyzed statistically. The following results were obtained : 1. Experimental group 2-A showed the highest shear bond strength with $9.87{\pm}1.24$ kgf and control group B showed the lowest shear bond strength with $4.08{\pm}0.78$ kgf(P<0.01). 2. The Fuji II LC showed higher shear bond strength with $9.49{\pm}1.24$ kgf than that of the Vitremer with $4.23{\pm}1.24$ kgf. There was significant difference between Fuji II LC and Vitremer(p<0.01). 3. There was no significant differences among experimental groups according to curing time induced by argon laser. 4. There was no significant differences between control group and experimental groups according to curing units.

  • PDF

산 표면처리된 상아질 표층의 교원섬유 용해가 레진-상아질간 결합에 미치는 영향 (EFFECT OF COLLAGEN DISSOLUTION IN ACID CONDITIONED DENTIN LAYER ON RESIN-DENTIN ADHESION)

  • 손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.856-868
    • /
    • 1995
  • The effect of collagen dissolution in acid conditioned dentin layer on resin - dentin adhesion was investigated. 160 freshly extracted human molars were divided into 4 groups randomly and dentin surfaces were exposed. 40 exposed dentin surfaces were not acid conditioned and each 10 of them were applied with bonding agents within dentin bonding systems of All Bond 2, Scotchbond Multipurpose, Clearfil Photobond and Superbond D - Liner respectively. Each 10 of another 40 exposed dentin surfaces were acid conditioned by the acid within the above four bonding systems respectively and applied with corresponding bonding systems. After acid conditioning of the other 40 exposed dentin surfaces as above, they were treated with 5% NaOCl for 2 minutes, and each 10 of them were applied with the above four dentin bonding systems respectively. The remaining 40 dentin surfaces were acid conditioned and treated with 10% NaOCl for 2 minutes, and each 10 of them were applied with corresponding bonding agents as the above. After the procedures were finished, composite resin (Z -100, 3M Dent. Prod., USA) were applied on the dentin surfaces and light cured. Shear bond strength values were measured. Surface changes of fractured dentin specimens were observed using SEM (Hitachi S-2350, Japan). The following results were obtained. 1. In all of dentin bonding systems, shear bond strengths of non - conditioned specimens were significantly lower than those of acid conditioned specimens (P<0.05). 2. A statistically significant difference of bond strengths did not exist between acid conditioned specimens and 5% NaGCI retreated specimens applied with All Bond 2, Scotchbond Multipurpose and Clearfil Photobond (P>0.05). However, strength values of 5% NaOCl retreated specimens applied with Superbond D - Liner were lower than those of acid conditioned specimens (P<0.05). 3. In all the applied dentin bonding systems except Clearfil Photobond, bond strengths of 10% NaOCl retreated specimens were lower than those of acid conditioned and 5% NaOCl retreated specimens (P<0.05). 4. The resin - dentin hybrid layer of 4 - $5{\mu}m$ thickness was formed in the acid conditioned specimens applied with All Bond 2, Scotchbond Multipurpose and Superbond D-Liner. 5. The resin - dentin hybrid layer of 3 - $4{\mu}m$ thickness was still formed in the 5% NaOCl retreated specimens applied with All Bond 2 and Scotchbond Multipurpose. In addition, this layer was not completely removed after the retreatment with 10% NaOCl. Above results indicate that the dissolution of collagen in acid conditioned dentin layer by NaOCl solution can not be achieved completely and the collagens contribute to the resin - dentin adhesion considerably.

  • PDF

Comparative evaluation of micro-shear bond strength to different luting procedures of ceramics to dentin

  • Lee, Yoon-Jeong;Park, Sang-Jin;Choi, Kyoung-Kyu
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.569-569
    • /
    • 2003
  • I. Objectives The purpose of this study was to evaluate the effort of a modified luting procedure called "dual bonding technique" by compare micro-shear bond strength to different luting procedures of ceramics to dentin. II. Materials and Methods Eighty-four freshly extracted caries-and restoration-free human third molar were embedded in epoxy resin using acrylic ring. Flat superficial occlusal dentin surfaces were obtained, initially using a Low speed diamond saw and exposed detin surface was group with #600-grit SiC paper.(omitted)

  • PDF

강화형 글라스 아이오노머 합착용 시멘트의 접합강도 및 변연누출에 대한 연구 (COMPARISON OF SHEAR BOND STRENGTH AND MARGINAL LEAKAGE OF RESIN MODIFIED GLASS IONOMER CEMENTS)

  • 박혜양;오남식;이근우;이호용
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.647-661
    • /
    • 1997
  • The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.

  • PDF

The effect of IDS (immediate dentin sealing) on dentin bond strength under various thermocycling periods

  • Lee, sungbok Richard;Lee, Sang-Min;Park, Su-Jung;Lee, Suk-Won;Lee, Do Yun;Im, Byung-Jin;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.224-232
    • /
    • 2015
  • PURPOSE. The purpose of this study was to find out the effect of immediate dentin sealing (IDS) on bond strength of ceramic restoration under various thermocycling periods with DBA (dentin bonding agent system). MATERIALS AND METHODS. Fifty freshly extracted human mandibular third molars were divided into 5 groups (1 control and 4 experimental groups) of 10 teeth. We removed enamel layer of sound teeth and embedded them which will proceed to be IDS, using All Bond II. A thermocycling was applied to experimental groups for 1, 2, 7, 14 days respectively and was not applied to control group. IPS Empress II for ceramic was acid-etched with ceramic etchant (9.5% HF) and silane was applied. Each ceramic disc was bonded to specimens with Duo-link, dual curable resin cement by means of light curing for 100 seconds. After the cementation procedures, shear bond strength measurement and SEM analysis of the fractured surface were done. The data were analyzed with a one-way ANOVA and Tukey multiple comparison test (${\alpha}$=.05). RESULTS. There were no statistically significant differences between 4 experimental groups and control group, however the mean value started to decrease in group 7d, and group 14d showed the lowest mean bond strength in all groups. Also, group 7d and 14d showed distinct exposed dentin and collapsed hybrid layer was observed in SEM analysis. CONCLUSION. In the present study, it can be concluded that ceramic restorations like a laminate veneer restoration should be bonded using resin cement within one week after IDS procedure.

유치에 적용된 All-in-One 상아질 접착 시스템의 전단강도에 관한 비교연구 (COMPARATIVE STUDY ON THE SHEAR BOND STRENGTH OF ALL-IN-ONE DENTIN BONDING SYSTEM APPLIED TO PRIMARY TEETH)

  • 김동철;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.560-568
    • /
    • 2007
  • 유치 60개를 준비하였으며, 사용된 접착 시스템은 AQ Bond $Plus^{TM}$, G $Bond^{TM}$, Single $Bond^{TM}$였다. 유치의 법랑질과 상아질을 노출시킨 후 제조사의 지시에 따라 접착 레진을 적용한 후, 내경 1.7 mm의 폴리에틸렌 튜브를 이용하여 Z-$250^{TM}$ 복합레진을 수복하였다. 100% 습윤 상태에서 24시간동안 보관 후 $5^{\circ}C$$55^{\circ}C$ 조건하에서 500회 열순환을 시행 후 만능시험기로 전단결합강도를 측정하였다. Resin tag 관찰을 위하여 상아질 접착면에 대해 수직으로 절단하고 인산과 질산으로 처리하여 치질을 용해시킨 후 주사 전자 현미경으로 관찰한 결과 다음과 같은 결론을 얻었다. 1. 유치 법랑질에서 측정된 전단 결합 강도는 AQ Bond $Plus^{TM}$에서 $1.04\;{\pm}\;0.13\;MPa$, G $Bond^{TM}$에서 $1.23\;{\pm}\;0.35\;MPa$, Single $Bond^{TM}$에서 $1.28\;{\pm}\;0.50\;MPa$이었으며, 세 군 간의 유의차는 없었다. 2. 유치 상아질에서의 전단 결합 강도는 AQ Bond $Plus^{TM}$$1.15\;{\pm}\;0.37\;MPa$, G $Bond^{TM}$$1.69\;{\pm}\;0.74\;MPa$ 그리고 Single $Bond^{TM}$$0.56\;{\pm}\;0.11\;MPa$로 나타났으며, AQ Bond $Plus^{TM}$와 G $Bond^{TM}$ 간에는 통계학적 유의차가 없었으나(p>0.05), AQ Bond $Plus^{TM}$와 Single $Bond^{TM}$, G $Bond^{TM}$과 Single $Bond^{TM}$ 간에는 통계학적 유의차를 보였다. 3. 주사 전자 현미경 소견에서 AQ Bond $Plus^{TM}$와 G $Bond^{TM}$는 resin tag 형성이 매우 미약하고 짧은 양상을 보인 반면, Single $Bond^{TM}$에서는 길게 형성된 resin tag가 관찰되었으며 resin tag의 표면에 불규칙하게 형성된 측부가지들이 관찰되었다.

  • PDF

불소처리된 치근상아질에 대한 심미수복재의 결합에 관한 연구 (A STUDY ON THE BOND OF AESTHETIC RESTORATIVE MATERIALS TO FLUORIDE TREATED ROOT DENTIN)

  • 탁홍수;박상진;민병순;최호영;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.197-212
    • /
    • 1998
  • The purpose of this study was to evaluate the effects of fluoride application on the aspect of shear bond strength of three aesthetic restorative materials to dentin. One light-cured composite resin(Palfique Esterite) and two light-cured glass ionomer cements(Fuji II LC and Compoglass)were used in this study. 120 permanent molars were used for this study. The teeth were extracted due to the origin of periodontal disease. The crowns of all teeth were removed, and the remaining roots were embedded in epoxy resin. The mesial or distal surfaces of roots were ground flat to expose dentin and polished on wet 320-, 400-, and 600 grit SIC papers for a total of 120 prepared flat root dentin surfaces. The prepared samples were divided into six groups. Group 1, 3, and 5 were control groups and group 2, 4, and 6 were experimental groups. Sixty samples for experimental groups were treated with 2% NaF solution for 5 minutes. Group 1 and 2 were bonded with Plafique Esterite, group 3 and 4 were bonded with Fuji II LC, and group 5 and 6 were bonded with Compoglass. After 24 hours water storage at $37{\pm}1^{\circ}C$, all samples were subjected to a shear to fracture with Instron universal testing machine(No.4467) at 1.0 mm/min displacement rate. Dentin surfaces treated with each conditioners before bonding and interfacial layers between dentin and aesthetic restorative materials were observed under Scanning Electron Microscope(Hitachi S-2300) at 20Kvp. The data were evaluated statistically at the 95% confidence level with ANOVA test. The result were as follows; 1. Among the control groups, group 1 showed strongest bond strength and group 3 showed weakest. 2. Among the experimental groups, group 2 showed strongest bond strength and group 6 showed weakest. 3. Statistical analysis of the data showed that pretreatment of dentin with 2% NaF solution significantly decreased the bond strength of three aesthetic restorative materials to dentin(P<0.05). 4. SEM findings of fluoride treated dentin surfaces (2, 4, 6 group) demonstrated dentin surfaces covered with fluoridated reaction products. 5. Except group 4 and 6, resin tags were formed in all groups.

  • PDF

지혈제의 종류에 따른 레진 강화형 글라스아이오노머 시멘트 결합력의 차이 (Difference in Bonding Strength of RMGIC according to Type of Hemostatic Agent in Primary Tooth)

  • 백설아;이준행;김종빈;한미란;김종수
    • 대한소아치과학회지
    • /
    • 제48권4호
    • /
    • pp.460-466
    • /
    • 2021
  • 이 연구의 목적은 유치의 상아질면에서 염화알루미늄 지혈제와 황화철 지혈제의 적용이 레진강화형 글라스아이오노머(RMGIC)의 결합에 미치는 영향을 전단결합강도를 통하여 평가하는 것이다. 20개의 우식이 없는 유구치가 이용되었으며 상아질이 노출되도록 시편을 제작하여 지혈제의 종류에 따라 3개의 군으로 분류하였다. I군은 치면에 25% polyacrylic acid(PAA)를 10초간 사용한 군, II군은 21.3% 염화알루미늄 지혈제를 1분간 사용한 뒤 PAA를 10초간 적용한 군, III군은 20% 황화철 지혈제를 1분간 사용한 뒤 PAA를 10초간 적용한 군으로 설정하였다. 각 군당 10개의 시편에 RMGIC를 중합하여 전단결합강도를 측정하였다. 결합강도는 I군이 10.07 ± 1.83 MPa, 2군에서 7.62 ± 0.78 MPa, 3군에서 5.23 ± 0.78 MPa였다. 모든 군의 결합강도는 유의한 차이를 보였다. 이 연구를 통해 염화알루미늄 지혈제, 황화철 지혈제 모두 상아질에서 RMGIC의 전단결합강도를 감소시키며 황화철 지혈제가 염화알루미늄 지혈제보다 RMGIC의 전단 결합강도를 더 많이 감소시키는 것을 알 수 있었다.

근관충전용 실러의 물리적 성질에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES OF ROOT CANAL SEALERS)

  • 장영인;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.142-151
    • /
    • 1995
  • The purpose of this study was to compare and estimate the physical properties of five root canal sealers classified Calciobiotic root canals sealer as calcium hydroxide based sealer, Apatite root sealer type II as calcium phosphate based sealer, AH-26 as resin based sealer, Canals and Pulpdent root canals sealer as zinc oxide eugenol based sealer. The author investigated dimensional change and flow rate of canal sealers, diametral tensile strength and shear bond strength of sealers to dentin to evaluate the physical properties on affect of complete obturation of root canal and performed the total 100 specimens of each 25 sealers under the condition of root temperature according to manufacturer's instructions. All specimens were stored at $37{\pm}1^{\circ}C$ in 100 % relative humidity. A microscope for measurement of micro distance is used for the dimensional change test and evacuation methods using vaccum were used for the flow rate test. The result differed by the storage time measured on the tests of diametral tensile strength and shear bond strength to dentin. The following results were obtained ; 1 On the test of dimensional change, Canals and Pulpdent expanded slightly, AH-26 and Apatite showed the severe shrinkage after 48 hours. 2. AH-26 and Apatite were the excellent with each 24.59mm, 31.19mm after 3 minutes in the aspect of flow property. 3. On the diametral tensile strength, Calciobiotic root canals sealer showed the highest strength with 27.13kg/$cm^2$ after 48 hours, Apatite root sealer type II showed highest strength with 84.57kg/$cm^2$ after 120 hours. 4. On the shear bond strength to dentin, AH-26 was most excellent with 55.73kgf/$cm^2$ after 24 hours and with 134.71kgf/$cm^2$ after 120 hours.

  • PDF