• 제목/요약/키워드: Shear Test

검색결과 4,458건 처리시간 0.027초

Direct Shear Test of Retrofit Anchors Using Deformed Reinforcement and Adhesive

  • Choi, Dong-Uk;Kim, Yong-Gon
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.91-99
    • /
    • 2000
  • A new type of retrof=t anchor bolt that uses deformed reinforcing bars and a commercial adhesive was developed and then an experimental study was carried out to determine the behavior of the anchors in direct shear. The steel-to-concl몫ete interface was tested. Plain concrete slabs with about 20-MPa compressive strength were used for 23 direct shear tests performed Test variables were anchor diameters (D16, D22. and D29) and edge effect. Three different shear tests were completed: simple shear, edge shear where anchors were pulled against the concrete core, and edge shear where anchors were pushed against the concrete cover In the simple and the edge shear tests where the anchors were pulled against the core, the theoretical dowel strength determined by (equation omitted) was achieved but with relatively large displacements. The shear resistances increased with the increasing displacements. In the edge shear test where the anchors were pushrd against the cover, the peak shear strengths signif=cantly lower than the theoretical dowel strength were determined due to cracks developed in concrete when the edge distance was 80 mm. The peak strengths were about 50% of the dowel strength for Dl6 bar. and about 25% or less of the dowel strength for D22 and D29 bars. Test results revealed that the edge shear where the anchor was pushed against the cover controled.

  • PDF

Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis

  • Kim, Kun-Soo;Han, Oneil;Gombosuren, Munkhtulga;Kim, Sang-Hyo
    • Steel and Composite Structures
    • /
    • 제31권1호
    • /
    • pp.53-67
    • /
    • 2019
  • This study presents finite element analysis (FEA) on a Y-type perfobond rib shear connection using Abaqus software. The performance of a shear connection is evaluated by conducting a push-out test. However, in practice, it is inefficient to verify the performance by conducting a push-out test with regard to all design variables pertaining to a shear connector. To overcome this problem, FEA is conducted on various shear connectors to accurately estimate the shear strength of the Y-type perfobond rib shear connection. Previous push-out test results for 14 typical push-out test specimens and those obtained through FEA are compared to analyze the shear behavior including consideration of the design variables. The results show that the developed finite element model successfully reflects the effects of changes in the design variables. In addition, using the developed FEA model, the shear resistance of a stubby Y-type perfobond rib shear connector is evaluated based on the concrete strength and transverse rebar size variables. Then, the existing shear resistance formula is upgraded based on the FEA results.

지르코니아와 포세린의 전단결합강도 (Shear Bond Strength Between Zirconia and Porcelain)

  • 김사학
    • 대한치과기공학회지
    • /
    • 제33권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: To examine the shear bond strengths of zirconia and veneering ceramic according to their surface processing. Methods: The test samples were divided into three groups: one without zirconia surface processing, one sandblasted, and one sandblasted then 3% etched. Then veneering ceramic was fired on all test samples, and their shear bond strengths were measured. Results: The test samples of the control group (Z1) showed the lowest shear bond strengths of $21.82{\pm}1.02$ MPa. The shear bond strengths of Z2 and Z3 ($28.25{\pm}0.72$ and $26.23{\pm}0.82$ MPa, respectively) were relatively higher than those of the control group. The fracture surface of the control group showed adhesive fractures while the test groups had relatively large numbers of cohesive fractures. Conclusion: The shear bond strength was high in the test groups with surface processing while the fracture surfaces showed compound fractures of adhesive and cohesive fractures.

줄눈 보강을 통한 면내 방향의 조적조 사인장 전단강도 평가 (Shear Strength Evaluation in Masonry Assemblages by Reinforcing Materials in Joint)

  • 우종훈;신경재;이준섭;한승윤
    • 대한건축학회논문집:구조계
    • /
    • 제35권9호
    • /
    • pp.191-198
    • /
    • 2019
  • All over the Republic of Korea, there are many masonry buildings which have been built since 1970s. When the earthquake at Po-Hang occurred, this is the main cause of huge damage because the masonry buildings have not seismic capacity. When masonry buildings are failed, two type of the failure modes can be shown, which are in-plane mode and out-plane mode. In-plane mode can have seismic capacity in masonry so diagonal shear test is performed in this study. The purpose of this study was to find the best way to reinforce the materials through the diagonal shear test. Through the test, shear stress and shear modulus of elasticity will be calculated, referred to the ASTM E 519-02. The variables in this test are ${\phi}3$ wire, three types of wire meshes, polypropylene strap and different types of brick. Each variable is applied to the same condition of the $1.2m{\times}1.2m$ masonry walls which are made by ASTM E 519-02. Compared to each variable with shear stress and shear modulus of elasticity, the best way of reinforcing method to have seismic capacity will be proved in this study.

직접전단시험과 이산요소법에 기반한 전단 시뮬레이션과의 비교 (A Comparison of the Direct Shear Test and Shear Simulation Based on the Discrete Element Method)

  • 정성헌;손정현
    • 한국기계가공학회지
    • /
    • 제19권3호
    • /
    • pp.86-91
    • /
    • 2020
  • An important factor of rough road modeling is analyzing the shear behavior properties of the rough road. These properties influence the drawbar pull of the tool when interacting with the soil used in agriculture. Furthermore, shear behavior properties are important because sinkage and shear stress are generated when wheels drive on rough roads. In this study, we performed a direct shear test to investigate the shear behavior properties of soils and compare with the direct shear simulation; shear force derived by the coupled analysis of discrete element method; and multi-body dynamics. Soil contact parameters were measured in a wheel and soil contact simulation followed by comparison of the simulated and experimentally measured shear force.

Iosipescu Shear Test를 이용한 고분자 복합재료의 종방향 전단계수 연구 (Effective Longitudinal Shear Modulus of Polymeric Composite Using Iosipescu Shear Test)

  • 정태헌;권용수;이유태;이동주
    • 한국산업융합학회 논문집
    • /
    • 제3권1호
    • /
    • pp.61-67
    • /
    • 2000
  • Effective shear modulus of continuous fiber reinforced polymeric composites is measured using a modified Iosipescu Shear Test(IST) and compared with data obtained by finite element analyses that a concept of unit cell is. It is found that the numerical results of the longitudinal shear modulus give a good agreement with experimental data at lower fiber volume fraction. In this paper, both the distance and stress transfer between the fibers are discussed as the major factors.

  • PDF

폴콘을 이용한 유류 오염 점토지반의 전단강도 예측 (Prediction of the Shear Strength of Oil Contaminated Clay using Fall Cone)

  • 송영우;이한석;박준범
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.107-113
    • /
    • 2010
  • This paper presents the prediction of shear strength of oil contaminated clay using fall cone test used to determine the liquid limit of soil. The penetration depth of fall cone is related to water content of soil. Laboratory vane shear can also be related to water content. To explore the relative correlation between penetration depth of fall cone and laboratory vane shear, both fall cone tests and laboratory vane shear test were carried out with water contents of soil. The developed empirical relationships in this studys showed that the shear strength is reduced to 3.9% with 1% increase of oil content. And, the lesser initial water content of contaminated clay, the more shear strength of contaminated clay is affected by oil content.

플립칩 패키지 BGA의 전단강도 시험법 표준화 (Regulation in Shear Test Method for BGA of Flip-chip Packages)

  • 안지혁;김광석;이영철;김용일;정승부
    • 마이크로전자및패키징학회지
    • /
    • 제17권3호
    • /
    • pp.1-9
    • /
    • 2010
  • 본고에서는 마이크로 접합을 위한 솔더볼 또는 범프의 기계적 신뢰성 평가에 사용되는 전단시험의 표준화 규격에 대해 고찰해 보았다. 전단시험에서 중요한 실험 조건 중 하나인 전단속도는 low speed shear test와 high speed shear test로 구분 된다. 전단속도가 빨라질수록 솔더볼에 가해지는 충격이 커지기 때문에, 소성변형에 대한 저항성이 커지게 되고, 전단강도가 커지게 된다. 그리고 이 결과는 전산모사를 통하여 확인할 수 있다. 또 하나의 중요한 실험 조건으로 전단툴의 높이가 있다. 일반적으로 전단툴의 높이가 높을수록 전단강도 값은 낮아지게 되는데, 여러 국제 규격에서 제시한 솔더볼 높이의 25% 지점을 초과한 높이에서 전단시험을 진행했을 때에는 전단시험이 진행되는 접합 계면의 면적이 줄어들어 실험결과의 신뢰도가 떨어지게 된다. 이와 같이 전단속도와 툴의 높이 등의 실험조건들이 구체적으로 규격화 되어있지 않은 채 진행 되면, 실험 결과의 신뢰도가 떨어지고, 각 계에서 진행된 연구결과를 상호 비교하기가 어렵다. 따라서 효율성을 고려한 간접 시험법 개발 및 최신 패키징기술을 반영된 특성평가 시험법의 규격, 그리고 다양한 시험 표준화는 결국 마이크로 전자패키지의 고 신뢰성으로 나타날 것이라 생각된다.

철도 강화노반재료의 정ㆍ동적 특성 분석 (Analysis of Static and Dynamic Characteristics of Reinforced Roadbed Materials)

  • 황선근;신민호;이성혁;이시한;최찬용
    • 한국철도학회논문집
    • /
    • 제3권1호
    • /
    • pp.34-41
    • /
    • 2000
  • The analysis of static and dynamic characteristics of reinforced roadbed materials was performed through model and laboratory tests. The strength characteristic of reinforced roadbed materials such as HMS-25 and soil were investigated through the unconfined axial compression test, the model soil box test and the combined resonant column and torsional shear test. The unconfined axial compression strength of HMS-25 shows a steady increasement in strength due to the chemical hardening reaction between HMS-25 and water. The result of model soil box test reveals that railroad roadbed of HMS-25 is better than that of soil in several aspects, such as, bearing capacity and settlement. The combined resonant column and torsional shear test result indicates that shear modulus of HMS-25 and soil increase with the power of 0.5 to the confining pressure and linear relationship to normalized shear modulus and damping ratio.

  • PDF

굵은 입자가 포함된 풍화토의 전단강도 평가에 대한 실험연구 (An Experimental Study on the Evaluation of Shear Strength of Weathered Soil Containing Coarse Particles)

  • 김준석
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.169-176
    • /
    • 2024
  • 연구목적: 본 논문에서는 직접전단시험에서 시험시편의 규모 때문에 부득이 굵은 입자가 제외되는 문제 때문에 발생되는 전단강도의 차이를 분석하고자 직접전단시험을 실시하는 실험연구를 수행하였다. 연구방법: 최대직경 50mm의 굵은 골재가 포함된 3개의 풍화토를 대상으로 대형직접전단시험을 실시하였다. 또한 굵은 골재가 제외된 최대직경 5mm 시료를 이용하여 소형직접전단시험을 실시하였다. 연구결과: 소형직접전단시험의 경우 큰입자가 포함된 대형직접전단시험의 결과에 비하여 내부마찰각은 약2.3% 작은 값을 도출하여 비교적 큰 차이가 없었다. 점착력에서는 대형직접전단시험에 비하여 소형 직접전단시험이 약 80.3% 작은 값을 도출하여 비교적 큰 차이를 나타내었다. 결론: 대형직접전단시험에서 굵은 입자가 내부마찰각보다는 점착력에 큰 영향을 준 것으로 분석되었다. 따라서, 굵은 입자를 포함한 화강풍화토는 수직응력에 영향을 받지 않는 점착력과 같은 전단강도를 갖고 있는 것으로 판단된다. 본 연구에서는 일반적으로 사용되고 있는 굵은 입자를 제외한 소형직접전단시험은 굵은 입자의 효과를 제외함으로서 안전측의 결과를 제공하는 것으로 분석되었다.