• 제목/요약/키워드: Shear Reinforcing Bars

검색결과 126건 처리시간 0.02초

Rapid Repair of Severely Damaged RC Columns with Different Damage Conditions: An Experimental Study

  • He, Ruili;Sneed, Lesley H.;Belarbi, Abdeldjelil
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권1호
    • /
    • pp.35-50
    • /
    • 2013
  • Rapid and effective repair methods are desired to enable quick reopening of damaged bridges after an earthquake occurs, especially for those bridges that are critical for emergency response and other essential functions. This paper presents results of tests conducted as a proof-of-concept in the effectiveness of a proposed method using externally bonded carbon fiber reinforced polymer (CFRP) composites to rapidly repair severely damaged RC columns with different damage conditions. The experimental work included five large-scale severely damaged square RC columns with the same geometry and material properties but with different damage conditions due to different loading combinations of bending, shear, and torsion in the previous tests. Over a three-day period, each column was repaired and retested under the same loading combination as the corresponding original column. Quickset repair mortar was used to replace the removed loose concrete. Without any treatment to damaged reinforcing bars, longitudinal and transverse CFRP sheets were externally bonded to the prepared surface to restore the column strength. Measured data were analyzed to investigate the performance of the repaired columns compared to the corresponding original column responses. It was concluded that the technique can be successful for severely damaged columns with damage to the concrete and transverse reinforcement. For severely damaged columns with damaged longitudinal reinforcement, the technique was found to be successful if the damaged longitudinal reinforcement is able to provide tensile resistance, or if the damage is located at a section where longitudinal CFRP strength can be developed.

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

축소 철근콘크리트 벽체의 내력과 균열진전에 대한 개구부모서리 균열제어 띠의 영향 (Effect of Crack Control Strips at Opening Corners on the Strength and Crack Propagation of Downsized Reinforced Concrete Walls)

  • 왕혜린;양근혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.40-47
    • /
    • 2022
  • 이 연구의 목적은 철근콘크리트 벽체의 내력, 변형 및 균열진전에 대한 개구부 모서리의 사인장 균열 제어를 위한 다양한 보강방법들이 효율성을 평가하는 것이다. 개구부 모서리의 사인장 균열제어 보강방법으로서 이 연구에서 제안한 균열제어 띠, 기존의 경사보강근 배근방법, 그리고 응력분산곡면판을 선택하였다. 균열제어 띠에서는 균열치유 기능성이 부여된 것도 함께 고려하였다. 개구부 주위의 체적변화 및 균열 폭 진전을 평가하기 위하여 개구부 모서리에서 사인장 균열 유도를 위한 축소 벽체 실험을 수행하였다. 실험결과 균열제어 띠는 경사보강근 및 응력분산곡면판에 비해 개구부 주위의 체적변화 감소 및 개구부 모서리 균열 폭 제어에 효율적이었다. 균열 치유 기능이 포함된 균열제어 띠는 사전 실험에서 발생한 균열들을 치유하면서 축소 벽체의 내력 향상 및 균열 폭 감소에 가장 좋은 성능을 보였다.

격자형 CFRP 보강재의 격자간격에 따른 콘크리트 부착거동에 대한 실험적 연구 (An Experimental Study on Concrete Bond Behavior According to Grid Spacing of CFRP Grid Reinforcement)

  • 노치훈;장낙섭;오홍섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.73-81
    • /
    • 2022
  • 최근 구조물의 사용연한이 증가함에 따라 다양한 요인에 의해 철근이 부식되어 구조물의 내하력이 감소하는 문제들이 발생하고 있다. 이를 해결하기 위하여 내식성, 경량성, 고인장강도를 갖는 FRP 보강근의 부착특성에 대한 연구가 활발히 진행중이나, 콘크리트에 매립된 격자형 CFRP 보강재의 부착특성에 관한 연구는 미흡한 실정이다. 따라서 격자형 CFRP 보강재를 철근의 대체재로 사용하고 사용성 측면에서 부착특성을 평가하기 위해, 격자형 CFRP 보강재의 종방향 부착길이와 횡방향 격자길이를 변수로 하여 직접인발시험을 수행하였다. 이를 통해 격자형 CFRP 보강재의 부착하중-슬립 곡선을 도출하였으며, 부착거동을 분석하였다. 총 부착하중 식은 종방향 부착길이의 부착력과 횡방향 격자의 전단력의 합으로 제안하였으며, 부착하중-슬립곡선의 면적을 전체 일로 표현하여 슬립량에 대한 에너지 소산량의 변화를 분석하여 횡방향 격자가 부착력에 미치는 영향에 대하여 검토하였다.

다양한 배근상세를 갖는 짧은 연결보의 주기거동 특성과 에너지소산능력의 평가 (Behavioral Characteristics and Energy Dissipation Capacity of Short Coupling Beams with Various Reinforcement Layouts)

  • 엄태성;박홍근;강수민
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.203-212
    • /
    • 2008
  • 본 연구에서는 다양한 배근상세를 갖는 짧은 연결보 (short coupling beam)의 주기거동특성과 에너지소산 메커니즘을 연구하였다. 주기하중을 받는 연결보의 수치해석을 위하여 비선형트러스모델 (nonlinear truss model)을 사용하였다. 수치해석 결과, 일반적인 수직 수평배근상세를 갖는 연결보는 핀칭이 심한 주기곡선을 보이며 거의 에너지를 소산하지 못하였다. 반면 대각배근상세를 갖는 연결보는 핀칭이 없는 안정적인 주기거동을 보이며 많은 에너지를 소산하였으며, 연결보의 에너지소산은 취성재료인 콘크리트보다 주로 대각 방향으로 배치된 철근에 의하여 발생됐다. 이러한 분석 결과를 토대로 대각철근의 변형률 이력을 사용하여 연결보의 에너지소산량을 예측할 수 있는 간편한 평가식을 개발하였다. 검증을 위하여 제안된 평가식과 실험으로 구한 연결보의 에너지소산량을 실험 결과와 비교하였다. 그 결과, 제안된 평가식은 배근형태, 전단경간비, 비탄성 변형 크기 등 다양한 설계변수의 영향을 고려하여 전단경간비가 1.25이하인 짧은 연결보의 에너지소산량을 비교적 정확히 예측하였다. 제안된 에너지소산량 평가 방법은 철근콘크리트구조물 및 부재의 성능 기초 내진평가/설계에 손쉽게 활용될 수 있다.

RC 및 SFRC 외부 보-기둥 접합부에 대한 고강도 확대머리 철근의 정착강도 (Development Strengths of High Strength Headed Bars of RC and SFRC Exterior Beam-Column Joint)

  • 장덕영;정재원;이강석;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.94-101
    • /
    • 2023
  • 본 연구에서는 철근콘크리트(RC) 및 강섬유보강콘크리트(SFRC) 외부 보-기둥 접합부에서 SD700인 확대머리철근의 정착성능을 실험적으로 평가하였다. 실험체는 총 10개로 제작되었으며 강섬유 보강 유무, 정착길이, 보의 유효춤, 스터럽 배근상세 등을 변수로 계획하였다. 실험결과, 실험체는 실험변수에 따라 측면파열파괴, 콘크리트 브레이크아웃파괴, 전단파괴 등이 나타났다. 정착길이를 변수로 한 RC 계열실험체에서 정착길이가 25~80% 증가함에 따라 정착강도는 26.5~42.2% 증가하여 정착길이에 비례하지 않음을 확인하였다. 보의 유효춤이 2배인 JD 계열 실험체는 콘크리트 브레이크아웃파괴가 나타나 기준 실험체에 비하여 31.5~62% 최대내력이 감소하였다. 확대머리철근 주위의 전단보강근 간격이 기준실험체에 비하여 1/2배인 S 계열 실험체는 8.4~ 9.7% 최대내력이 증가하였다. SFRC 실험체 콘크리트 압축강도가 RC 실험체 콘크리트 압축강도에 비하여 29.3% 작게 평가되었지만, 정착강도는 7.3~12.2% 더 크게 증가하였다. 이에 강섬유 보강에 따른 확대머리 철근의 정착성능이 크게 향상됨을 확인하였다. KDS 기준의 정착길이 92%, 110%로 배근된 실험체의 실험 최대내력이 이론내력에 비하여 92%, 99%인 결과를 고려하면 안전율을 더욱 크게 고려할 필요가 있는 것으로 판단된다. 또한 정착길이 대비 보의 유효춤을 고려한 설계식 제시가 요구된다.