• 제목/요약/키워드: Shear Rate distribution

검색결과 112건 처리시간 0.03초

Effect of Amine Functional Group on Removal Rate Selectivity between Copper and Tantalum-nitride Film in Chemical Mechanical Polishing

  • Cui, Hao;Hwang, Hee-Sub;Park, Jin-Hyung;Paik, Ungyu;Park, Jea-Gun
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.546-546
    • /
    • 2008
  • Copper (Cu) Chemical mechanical polishing (CMP) has been an essential process for Cu wifing of DRAM and NAND flash memory beyond 45nm. Copper has been employed as ideal material for interconnect and metal line due to the low resistivity and high resistant to electro-migration. Damascene process is currently used in conjunction with CMP in the fabrication of multi-level copper interconnects for advanced logic and memory devices. Cu CMP involves removal of material by the combination of chemical and mechanical action. Chemicals in slurry aid in material removal by modifying the surface film while abrasion between the particles, pad, and the modified film facilitates mechanical removal. In our research, we emphasized on the role of chemical effect of slurry on Cu CMP, especially on the effect of amine functional group on removal rate selectivity between Cu and Tantalum-nitride (TaN) film. We investigated the two different kinds of complexing agent both with amine functional group. On the one hand, Polyacrylamide as a polymer affected the stability of abrasive, viscosity of slurry and the corrosion current of copper film especially at high concentration. At higher concentration, the aggregation of abrasive particles was suppressed by the steric effect of PAM, thus showed higher fraction of small particle distribution. It also showed a fluctuation behavior of the viscosity of slurry at high shear rate due to transformation of polymer chain. Also, because of forming thick passivation layer on the surface of Cu film, the diffusion of oxidant to the Cu surface was inhibited; therefore, the corrosion current with 0.7wt% PAM was smaller than that without PAM. the polishing rate of Cu film slightly increased up to 0.3wt%, then decreased with increasing of PAM concentration. On the contrary, the polishing rate of TaN film was strongly suppressed and saturated with increasing of PAM concentration at 0.3wt%. We also studied the electrostatic interaction between abrasive particle and Cu/TaN film with different PAM concentration. On the other hand, amino-methyl-propanol (AMP) as a single molecule does not affect the stability, rheological and corrosion behavior of the slurry as the polymer PAM. The polishing behavior of TaN film and selectivity with AMP appeared the similar trend to the slurry with PAM. The polishing behavior of Cu film with AMP, however, was quite different with that of PAM. We assume this difference was originated from different compactness of surface passivation layer on the Cu film under the same concentration due to the different molecular weight of PAM and AMP.

  • PDF

정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성 (Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow)

  • 이홍철;김철생;박복춘;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • 본 실험연구에서는 정상유동상태에서 새롭게 설계된 자가팽창성 그래프트 스텐트의 수력학적 성능을 평가하고자 하였다. 코팅 재질이 다른 두 개의 그래프트 스텐트와 한 개의 타이티놀 금속스텐트가 실험에 사용되었으며, 유량이 가자 5, 10, 15 1/min에서 스텐트 전후에서의 압력변화 및 속도분포를 측정하였다. 스텐트 삽입에 의한 압력손실은 유량이 증가함에 지수적으로 증가하였다. 특히 15 1/min의 유량에서 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트의 압력손실은 거의 동일하나 PU 그래프트 스텐트는 약 6배 이상의 현저한 증가를 보이고 있다. 스텐트 후류에서의 속도분포는 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트는 유량에 관계없이 유사한 형태를 보여주고 있다. 그러나, PU 그래프트 스텐트에서는 특히 유량이 10 1/min 이상에서 속도분포가 비대칭적이고 관 중심에서의 상대적인 낮은 유속을 보여주고 있으며, 결과적으로 벽면전단응력 및 수직응력의 증가론 초래하고 있다. 이와같이 PU 그래프트 스텐트의 상대적으로 낮은 수력학적 성능은 스텐트가 보다 작은 관에 삽입되었을때 코팅재질의 낮은 유연성으로 인하여 스텐트의 표면에 주름이 발생하여 유동단면이 비대칭적으로 되고 벽면의 조도가 증가하며, 관벽과 스텐트와 틈새가 존재하여 제트류가 형성되기 때문으로 해석된다.

Hemodynamic Interpretation of Various Extraanatomical Bypasses: Clinical & Engineering Views

  • Lee, Byung-Boong;Kim, Young-Wook;Suh, Sang-Ho;Roh, Hyung-Woon;Kim, Dong-Ik;Yoo, Sang-Sin;Cho, Min-Tae;Huh, Sung
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권1호
    • /
    • pp.32-40
    • /
    • 2003
  • Axillo-bifemoral (Ax-Fem) bypass are now well accepted for bilateral iliac artery occlusion as the second best option. This extra-anatomical (unnatural) bypasses, however, have various hemodynamic liabilities affecting the patency. Hemodynamic conditions of each different type of Ax-Fem bypass were assessed with computer simulation model to determine the hemodynamically more sound type. Simulation models of five different types of Ax-Fem bypass were constructed. Our investigation based on the computer simulation models have shown distinct differences between two most popular Lazy-S type and Inverted-C type on the distribution of flow volume, shear stress and recirculation zone, etc., though both types have shown similar clinical results. Lazy-S type has shown better hemodyanmic status than inverted-C type. The theoretical advantage of "Lazy-S" type has never been adequately proved for its superiority clinically over the inverted-C type. Inverted-C type is now in more favor with clinically better results in spite of many hemodynamic liabilities including retrograde flow to the branching graft. The improvement of over-all long-term patency rate of various extra-anatomical bypasses is still warranted through proper correction of the hemodynamic liability. Even though clinical outcome of the extra-anatomical bypass has been equal regardless of the type of crossover femoral graft configuration, there are distinct differences on the hemodynamic characteristics among various types of configuration. Further hemodynamic study in the pulsatile flow status is warranted to correct hemodynamic defects with proper modification of various hemodynamic factors of each model.

  • PDF

5052 알루미늄 합금에서 접합변수에 따른 겹치기 마찰교반접합부의 특성 (Characteristics of Friction Stir Lap Weldment according to Joining Parameter in 5052 Aluminium Alloy)

  • 고영봉;박경채
    • 한국표면공학회지
    • /
    • 제45권5호
    • /
    • pp.181-187
    • /
    • 2012
  • The Friction Stir Welding (FSW) has mainly been used for making butt joints in Al alloys. The development of Friction Stir Lap Welding (FSLW) would expand the number of applications. In this study, microstructures and mechanical properties of FSLW in A5052 alloy were investigated under varying rotating speed and probe length. Investigating the characteristics as FSLWed conditions were as below ; Failure Maximum load by shear fracture was increased proportional to the width of joint area, which was increased by input heat, stirring intensity in the case of 2.3 mm probe length. Tensile fracture occurred, and maximum load was determined due to side worm hole of joint area and softening of microstructure in the case of 3.0 mm probe length. In the case of 3.7 mm probe length, material hook and bottom worm hole were appeared at the end interface of joint area. The most sound FSLW condition with no defects was 3.0 mm probe length and 1500 rpm-100 mm/min. No defects were showed in 1500 rpm-100 mm/min and 1800 rpm-100 mm/min, but Vickers microhardness distribution in TMAZ/HAZ which was fracture zone was lower in 1800 rpm-100 mm/min than in 1500 rpm-100 mm/min. In this condition highest tensile strength, 215 MPa (allowable rate 78% of joint efficient) was obtained.

모형실험을 통한 말뚝의 p-y 곡선에 관한 연구 (A Study on the p-y Curves by Small-Scale Model Tests)

  • 김태식;정상섬;김영호
    • 대한토목학회논문집
    • /
    • 제28권1C호
    • /
    • pp.41-51
    • /
    • 2008
  • 본 논문은 말뚝 및 기초지반의 강성이 수평재하말뚝의 거동에 미치는 영향을 알아보고자 주문진 표준사와 김해점토를 기초지반으로 수평재하말뚝에 대한 실내실험을 실시하였다. 또한 실험 결과를 바탕으로 영향계수를 정량화 할 수 있는 경험식을 산정하였다. 말뚝과 지반의 강성을 고려하기 위하여 길이가 다른 3개의 알루미늄 모형말뚝을 제작하였으며 이를 사질토와 점성토 지반에 설치한 후 기초지반의 상대밀도(사질토 지반) 및 비배수전단강도(점성토 지반)를 변화시켜가며 수평재하 실내실험을 수행하였다. 실험을 통하여 산정된 p-y 곡선의 초기기울기는 사질토와 점성토 지반 모두에서 깊이와 말뚝-지반의 강성에 비례하였으나 점성토 지반의 경우 사질토 지반에 비하여 깊이에 따른 초기기울기의 증가율이 작은 경향을 나타내었다. 또한 극한 지반반력의 경우 모든 지반 조건에서 수평지반반력계수와 유사하게 깊이와 지반강성에 비례하여 증가하였으나 말뚝 강성에 대한 영향은 적게 나타났다. 이와 같은 특성을 고려하여 본 논문에서는 p-y 곡선의 초기기울기 산정 식을 실험결과와 가장 유사한 형태를 지니는 쌍곡선으로 지반 조건에 따라 제시하였으며 제안된 식을 기존의 연구 및 현장재하시험과 비교하여 제안 식의 적용성을 검증하였다.

측방유동을 받는 교대말뚝기초의 거동분석 (I) - 원심모형실험 연구 - (The Behavior of Piled Bridge Abutments Subjected to Lateral Soil Movements - A Study on the Centrifuge Model Tests -)

  • 서정주;서동희;정상섬;김유석
    • 한국지반공학회논문집
    • /
    • 제19권1호
    • /
    • pp.5-19
    • /
    • 2003
  • 본 연구에서는 인접 성토로 인하여 측방유동이 발생하는 연약한 점성토 지반에 시공된 교대말뚝기초를 원심모형실험으로 재현하여 지반조건과 성토지반의 시공속도에 따른 교대말뚝기초의 거동특성을 분석하였다. 이를 위해 지반조건과 성토지반 시공속도를 교대말뚝기초의 측방유동에 가장 중요한 영향을 미치는 변수로 선정하여 총 6 종류의 원심모형실험을 실시하였다. 본 실험에서 지반조건은 점성토 지반의 두께와 지층단면에 따라 세 가지 종류로 구분하였으며 성토하중 재하조건은 한계성토고까지 단계적으로 재하하는 방법(1m/30일, 1m/15일)과 한계성토고에 해당하는 하중을 급속재하 하는 방법으로 나누어 고려하였다. 그 결과 동일한 조건하에서 측방유동을 받는 교대말뚝기초의 비배수 단기거동과 장기거동을 파악하기 위해 성토하중 재하단계와 성토 후 압밀이 약 80% 진행된 단계에서의 지반-말뚝 거동특성을 비교ㆍ 분석하였다. 본 연구 결과, 편차 성토하중으로 인해 연약지반상 교대말뚝기초에 발생하는 측방유동압은 단계별 성토하중 재하시 사다리꼴 분포형태와 유사하였으며 이때 발생하는 최대 측방유동압($P_{max}$)과 편차 성토하중($\gamma$ H)의 비($\alpha$)는 비배수 상태인 단기거동시에는 0.75, 압밀이 약 80% 진행된 장기거동시에는 0.35 정도로 나타남을 알 수 있었다.

고준위폐기물처분장의 완충재 개념 도출: 접근방안 (Establishing the Concept of Buffer for a High-level Radioactive Waste Repository: An Approach)

  • 이재완;이민수;최희주
    • 방사성폐기물학회지
    • /
    • 제13권4호
    • /
    • pp.283-293
    • /
    • 2015
  • 고준위폐기물처분장에서 완충재는 공학적방벽의 주요 구성요소 중 하나이다. 본 연구에서는 국 내외의 완충재 요구사항과 성능기준을 분석하고, 우리나라 고준위폐기물처분장에 적합한 완충재 개념 도출을 위한 접근방안을 제시하였다. 완충재의 주요 성능기준 인자항목으로, 수리전도도, 핵종 저지능, 팽윤압, 열전도도, 역학적 특성치(mechanical properties), 유기물함량(organic carbon content), 일라이트화 속도(illitization rate) 등을 고려하였다. 우리나라 고준위폐기물처분장 완충재 물질로서 국산 벤토나이트(Ca-벤토나이트)와 대안재로 MX-80 벤토나이트(Na-벤토나이트)를 제안하였다. 완충재의 기술사양은 Ca-벤토나이트 경우엔 우리나라의 성능기준을, Na-벤토나이트의 경우는 스웨덴의 성능기준을 보수적으로 만족하는 값으로 설정하였다. 완충재의 두께는 전단거동, 핵종 유출, 열전도의 측면에서 평가하여 결정하였으며, 평가결과 완충재의 두께는 0.25 ~ 0.5 m 사이가 적절하였다. 그러나 최종적인 완충재의 두께는 향후 보다 심도 있는 열-수리-역학적 평가와 경제적, 공학적 측면을 고려하여 결정하여야 할 것이다.

복합지반 굴착 시 기반암의 깊이와 절리경사에 따라 흙막이벽체에 작용하는 토압 (Earth Pressure on the Braced Wall in the Composite Ground Depending on the Depth and the Joint Dips of the Base Rocks under the Soil Strata)

  • 배상수;이상덕
    • 한국지반공학회논문집
    • /
    • 제32권10호
    • /
    • pp.41-53
    • /
    • 2016
  • 토사층 하부에 절리암반층이 존재하는 복합지반을 굴착하고 설치하는 흙막이 구조물의 안정성은 배면에 작용하는 토압에 의해 결정된다. 보통 복합지반에서는 암반층을 토사로 간주하고 암반층의 지반강도 정수를 적용하여 경험적으로 토압을 구하는데, 암반층의 불연속면을 고려하지 않기 때문에 대개 실제 작용 토압보다 작게 산정된다. 본 연구에서는 복합지반에서 토사층과 암반층의 구성비율 및 암반층의 절리경사에 따라 흙막이 벽체에 작용하는 토압의 크기와 분포형태를 규명고자 대형토조(높이 3.0m, 길이 3.0m 폭 0.5m)에서 축척 1/14.5로 2차원 대형 모형실험을 수행하고, 같은 조건으로 수치해석을 수행하였다. 실험지반은 토사층과 암반층의 분포비가 각각 65%:35%와 50%:50%가 되도록 조성하였고, 암반층의 절리는 굴착측으로 $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$ 각도로 구성하였다. 그 결과 흙막이 벽체에 작용하는 토압은 암반층 절리 경사각(J)이 커질수록 증가 하였으며, 암반층비율이 증가함에 따라 암반층에 작용하는 토압도 증가하였다. 암반층에 작용하는 토압은 암반층의 비가 50%(R50)이고, 암반층의 절리 경사각이 $60^{\circ}$일 때 가장 크게 발생하였다. 대형모형실험과 수치해석 결과를 바탕으로 임의 복합지반을 굴착할 때 발생하는 토압을, 최상단 버팀대토압과 최대토압 및 굴착하단을 꼭짓점으로 하는 사각형분포로 이상화하고, 암반층비율과 절리경사각도를 고려하여 토압을 구할 수 있는 토압식을 제안하였다.

다공성재를 통과하는 압축성 유체의 압력강하에 관한 실험적 연구 (Experimental Study of Pressure Drop in Compressible Fluid through Porous Media)

  • 서민교;김도헌;서찬우;이승윤;장석필;구자예
    • 대한기계학회논문집B
    • /
    • 제37권8호
    • /
    • pp.759-765
    • /
    • 2013
  • 동축형 전단 분사기의 액적분포 균일도 및 혼합성능을 개선하기 위해 고안한 액체로켓 엔진용 동축형 다공성 분사기의 개발에 앞서 다공성재를 분사기에 적용하기 위해 다공성재를 통과하는 압축성 유체의 압력강하 특성을 파악하였다. Non-Darcy 유동의 압력강하는 점성력과 관성력으로 인한 손실을 포함하는 Forchheimer 방정식을 이용하여 도출할 수 있으며, 이 때 다공성재의 형상인자인 투과율과 관성력의 영향을 나타내는 Ergun 상수를 이용하여 다공성재를 통과하는 압축성 유체의 압력강하를 예측할 수 있다. 본 연구에서는 다공성재의 압력강하 특성을 나타내는 투과율와 Ergun 상수를 작동유체의 압력강하에 대한 함수로 나타내었으며, 최종적으로 이를 일반화하여 pore의 크기에 따라 압력강하를 예측할 수 있는 관계식을 도출하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF